manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BIANCO PUMPZ
  6. •
  7. Water Pump
  8. •
  9. BIANCO PUMPZ 2 Series User manual

BIANCO PUMPZ 2 Series User manual

Submersible Grinder Pumps
BIA-B120GS2 (802770)
(Auto Version)
BIA-B120GMS2 (803150)
(Manual Version)
BIA-B120TMS2 (806084)
(Manual Version)
B
I
A
N
C
O
2
2
Y
E
A
R
P
U
M
P
W
A
R
R
A
N
T
Y
2 |B120GS2, B120GMS2 & B120TMS2 Manual 2019 Disclaimer: Every eort has been made to publish the correct details in this brochure.
No responsibility will be taken for errors, omissions or changes in product specications.
Installation & Operating Instructions
The Bianco B120 submersible grinder pump is suitable for small to medium wastewater applications in industry, agriculture.
It is supplied with a primary cutter and secondary grinder which make it unique in the market and capable of dealing with a
multitude of dierent items in a waste water application including soft string-like materials. Not suitable for sand or gravel in
order to prevent abrasion on the cutter and grinder.
VOLTAGE OPTIONS:
• 240V, 50Hz, Single Phase
• 415V, 50Hz, Three Phase
Pumps should never be used to pump ammable, combustable or corrosive liquids.
GENERAL SAFETY
This appliance is not intended to be held in the hand during normal use.
Do not handle the pump when in operation and do not touch the liquid in which it is submerged.
Before performing any procedure (handling, inspection, installation, etc.) the power supply must be disconnected. The pump
surface needs to be cooled to ambient temperature (wait at least 30 minutes)
Do not place your hands or objects near and/or insert them in the pump’s intake or outlet
Always handle the electric pump while wearing individual protection devices in conformity with the law.
Do not allow the free end of the electric cable to come into contact with liquids of any kind.
This pump must not be used by children or inrm persons to prevent potential injury. The electricity supply must always
be switched o prior to handling the pump as the cutting/grinding device is exposed and could cause injury if not handled
properly.
If the supply cord is damaged, the pump should be returned to White International or one of its Authorized Service Agents
(list available on request) for repair in order to avoid potential injury / electrical shock.
INSTALLATION
The BIANCO B Series Grinder pumps are submersible up to 10m and can be installed on a level surface in a stationary position
connected to xed pipe work.
Never remove or lift a pump by its power cable. A rope or lifting chain must be attached to the handle of the pump at the time
of installation. Automatic pumps with a oat switch should be installed and a sump or pit of suitable size for the oat switches
to operate correctly. The oat switch if tted must be installed so the ON and OFF operating points can be easily reached i.e.
the oat switch head must not be too close to the latching holder. The oat switch must also not touch the base of the sump
or pit which could prevent the pump from switching o and causing it to run dry. Pumps should never be run dry.
The BIANCO B Series Grinder pumps rely on water for cooling of the motor. The pumps can operate partially submerged for up
to 10 minutes. Operating these pumps at very low ow i.e. high head or restricted pipework may cause the motor to overheat
and could cause catastrophic failure.
All electrical works connected to the mains must be performed by qualied personnel, in compliance with the
local regulations.
The electrical connection of the models without plug must be performed by connecting rst the yellow-green to the ground,
then the other wires.
To ensure safety the pump is to be supplied through a residual current device (RCD) having a rated residual operating current
not exceeding 30 mA.
Appliances without plug are intended to be permanently connected to xed wiring; a switch that ensure the all-pole
disconnection incorporated in the xed wiring is to be provided. The switch shall be directly connected to the supply
terminals and shall have a contact separation in all poles, providing full disconnection under overvoltage category III (4000V).
The pump motor must be protected from overload by installing in the main control circuit or power line of pump an overload
protection (motor protection breaker). The protection must be adequately dimensioned according to the rated pump data.
The starting current in direct-on-line start can be up to six times higher than the rated current.
Disclaimer: Every eort has been made to publish the correct details in this brochure.
No responsibility will be taken for errors, omissions or changes in product specications.
B120GS2, B120GMS2 & B120TMS2 Manual 2019 |3
Trouble Shooting
Fault Cause Remedy
Pump does not start
No mains supply Check that power is available at the
power socket and that it is switched on
Blown fuse or tripped breaker Replace fuse or reset breaker
Impeller jammed Disconnect power and clean impeller
area
Thermal overload has been
activated Allow the switch to reset itself
Float switch is in the down/
o position
Free the oat switch and change the
position of the pump to prevent this in
future
Insucient water level Float switch must be in the up/on
position (45° above horizontal)
No or low ow
Strainer or impeller blocked
by debris
Disconnest from power and clean
impeller area
Damage caused by abrasive
media
Pump may need to be serviced to
replace worn parts
Excessive friction loss or high
delivery head
Reassess if the pipe size and pump is
suitable for the application
Pump does not stop
Float switch is in the up/on
position
Free the oat switch and change the
position of the pump to prevent this in
future
Possible faulty oat switch Pump may need to be serviced to
replace faulty part
Pump switches o after
short period
Thermal overload has been
activated
Disconnect power and make sure
impeller is not clogged
Ensure water temperature is below
40°C
Check the length of the power supply
cable/extension. Possible voltage drop
over long distance
Ensure the pump is not operating at a
very low ow or very high head
CHECKING THE IMPELLER ROTATION DIRECTION
(three-phase models only)
Before making the three-phase electrical connection, make sure the rotation direction is correct.
To check the rotation direction, proceed as follows:
1. Take the precautions detailed in the“General Safety” above;
2. Lay the pump horizontal on one side and leave it free
3. Temporarily connect the yellow-green wire to ground and then connect the power supply wires to the contactor;
4. Make sure there are no people or objects within a radius of at least 1 metre of the pump;
5. Turn on the start switch for a few moments;
6. Watch the impeller as it stops through the intake port and check that it turns anticlockwise.
If the pump is rotating in the wrong direction, invert two of the power supply wires in the contactor and try again. Once the
correct rotation direction has been obtained, MARK the power supply wire connection positions, REMOVE the temporary
electrical connections and install the pump in the planned position.
4 |B120GS2, B120GMS2 & B120TMS2 Manual 2019 Disclaimer: Every eort has been made to publish the correct details in this brochure.
No responsibility will be taken for errors, omissions or changes in product specications.
P_AU/NZ_BIANCO_MANUAL_B120GS2 & B120GMS2
2 YEAR WARRANTY
White International Pty Ltd
Limited Product Warranties
TERMS & CONDITIONS
This warranty is given in addition to the consumer guarantees found within the Australian Competition and Consumer Act 2010
(Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand:
1) White International Pty Ltd / White International NZ Ltd (White International) warrant that all products distributed are free from
defects in workmanship and materials, for their provided warranty period as indicated on the top or opposite side of this
document. Subject to the conditions of the warranty, White International will repair any defective products free of charge at the
premises of our authorised service agents throughout Australia and New Zealand if a defect in the product appears during the
warranty period. If you believe that you have purchased a defective product and wish to make a claim under this warranty, contact
us on our Sales Hotline on 1300 783 601, or send your claim to our postal address or fax line below and we will advise you as to
how next to proceed. You will be required to supply a copy of your proof of purchase to make a claim under this warranty.
2) This warranty excludes transportation costs to and from White International or its appointed service agents and excludes defects
due to non-compliance with installation instructions, neglect or misuse, inadequate protection against the elements, low voltage
or use or operation for purposes other than those for which they were designed. For further information regarding the suitability
of your intended application contact us on our Sales Hotline on 1300 783 601. If you make an invalid claim under this warranty, the
original product will be sent back to you unrepaired.
3) This warranty refers only to products sold after the 1st January 2012, and is not transferable to another product type and only
applies to the original owner, purchaser or end user, and is in addition to the consumer guarantees found within the Competition
and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased
in New Zealand.
4) Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to
have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
5) To the fullest extent permitted by law, White International excludes its liability for all other conditions or warranties which would
or might otherwise be implied at law. To the fullest extent permitted by law, White International’s liability under this warranty and
any other conditions, guarantees or warranties at law that cannot be excluded, including those in the Competition and Consumer
Act 2010 (Cth), is expressly limited to:
(a) in the case of products, the replacement of the product or the supply of equivalent product, the payment of the cost
of replacing the product or of acquiring an equivalent product or the repair of the product or payment of the cost of
having the product repaired, is at the discretion of White International or a 3rd party tribunal elected under the
Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ
for goods purchased in New Zealand; and
6) To the fullest extent permitted by law, this warranty supersedes all other warranties attached to the product or its packaging.
7) In the case of services, supplying the services again or the payment of the cost of having the services supplied again, is at the
discretion of White International or a 3rd party tribunal elected under the Competition and Consumer At 2010 (Cth) for goods
purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand.
8) Our warranty commences from the date of purchase of the above mentioned pumps. Proof of purchase is required before
consideration under warranty is given. Record your date of purchase in the space below and retain this copy for your records.
B
I
A
N
C
O
2
2
Y
E
A
R
P
U
M
P
W
A
R
R
A
N
T
Y
Date of Purchase ....................................................................... Model Purchased .................................................................
WHITE INTERNATIONAL NZ LTD
15G Kerwyn Avenue
East Tamaki, Auckland 2013, New Zealand
Phone 09 579 9777 Fax 09 579 7775
Customer Service 0800 509 506
Customer Service Fax 0800 804 344
Email Sales: [email protected].nz
www.whiteint.co.nz
WHITE INTERNATIONAL PTY LTD
60 Ashford Ave Milperra NSW 2214
PO Box 304 Milperra NSW 2214
Phone 02 9783 6000 Fax 02 9783 6001
Customer Service 1300 783 601
Email Sales: [email protected]
www.whiteint.com.au

This manual suits for next models

6

Other BIANCO PUMPZ Water Pump manuals

BIANCO PUMPZ 2 Series Manual

BIANCO PUMPZ

BIANCO PUMPZ 2 Series Manual

BIANCO PUMPZ MULTI User manual

BIANCO PUMPZ

BIANCO PUMPZ MULTI User manual

BIANCO PUMPZ HS Series User manual

BIANCO PUMPZ

BIANCO PUMPZ HS Series User manual

BIANCO PUMPZ BIA - AUTOSUB User manual

BIANCO PUMPZ

BIANCO PUMPZ BIA - AUTOSUB User manual

BIANCO PUMPZ SUB450 User manual

BIANCO PUMPZ

BIANCO PUMPZ SUB450 User manual

BIANCO PUMPZ Q550B User manual

BIANCO PUMPZ

BIANCO PUMPZ Q550B User manual

BIANCO PUMPZ BIA-B10A Manual

BIANCO PUMPZ

BIANCO PUMPZ BIA-B10A Manual

BIANCO PUMPZ PTFINOX45S2NXT User manual

BIANCO PUMPZ

BIANCO PUMPZ PTFINOX45S2NXT User manual

BIANCO PUMPZ LSC530 User manual

BIANCO PUMPZ

BIANCO PUMPZ LSC530 User manual

Popular Water Pump manuals by other brands

Fristam Pumps FKL Series Original instructions

Fristam Pumps

Fristam Pumps FKL Series Original instructions

K2 Pumps UTA02502K owner's manual

K2 Pumps

K2 Pumps UTA02502K owner's manual

Salamander Pumps CT FORCE 15TU Installation and warranty guide

Salamander Pumps

Salamander Pumps CT FORCE 15TU Installation and warranty guide

dosatron D3 Series user manual

dosatron

dosatron D3 Series user manual

fluid-o-tech TP30 Series instruction manual

fluid-o-tech

fluid-o-tech TP30 Series instruction manual

ITT ST31 Installation, operation and maintenance instructions

ITT

ITT ST31 Installation, operation and maintenance instructions

AMICOCIRC AMICO 20-4-130 Handbook

AMICOCIRC

AMICOCIRC AMICO 20-4-130 Handbook

Liberty Pumps Builder S30 Series installation manual

Liberty Pumps

Liberty Pumps Builder S30 Series installation manual

swiftech MCP600 user guide

swiftech

swiftech MCP600 user guide

mbp BUD 23BS Instructions and parts list

mbp

mbp BUD 23BS Instructions and parts list

SunSun MAX-ECO CPP-5000F Operation manual

SunSun

SunSun MAX-ECO CPP-5000F Operation manual

Jessberger JP-05 operating instructions

Jessberger

Jessberger JP-05 operating instructions

Oase AquaMax Eco Premium 6000 operating instructions

Oase

Oase AquaMax Eco Premium 6000 operating instructions

Pfeiffer Vacuum HILOBE 1004 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum HILOBE 1004 operating instructions

CAT Pumps 7CP6110CS Service manual

CAT Pumps

CAT Pumps 7CP6110CS Service manual

NovaTec SVP-3 instruction manual

NovaTec

NovaTec SVP-3 instruction manual

Pentair Jung Pumpen DRENA-LINE Compli 310 E instruction manual

Pentair Jung Pumpen

Pentair Jung Pumpen DRENA-LINE Compli 310 E instruction manual

Grizzly GP 3032 Inox Translation of the original instructions for use

Grizzly

Grizzly GP 3032 Inox Translation of the original instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions