-5-
TABLE OF CONTENTS
1
BOILER DESCRIPTION ......................6
1.1 Assembly view.................................6
1.2 Shut-o valves and cocks ......................6
1.3 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 GeneralLCDcharacteristics.....................8
2 USER INSTRUCTIONS .....................11
2.1 Warnings .....................................11
2.2 Ignition.......................................11
2.3 Heating circuit temperature ...................12
2.4 Domestichotwatertemperature ..............13
2.5 3starpreheatingfunction.....................13
2.6 Shut-o ......................................14
3 USEFUL TIPS .............................15
3.1 Filling the heating circuit ......................15
3.2 Heating.......................................15
3.3 Antifreeze protection .........................15
3.4 Periodicmaintenance .........................16
3.5 Externalcleaning .............................16
3.6 Operatinganomalies..........................16
3.7 DisplaysinINFOmode ........................17
3.8 Remoteanomalycode ........................18
3.9 Fluegasprobe ................................19
4 TECHNICAL SPECIFICATIONS .............20
4.1 Assembly view................................20
4.2 Schematic diagram ...........................21
4.3 Wiring diagram ...............................23
4.4 TechnicaldataM160.2025SM/M ..............24
4.5 TechnicaldataM160.3035SM/M ..............27
4.6 Hydrauliccharacteristic .......................30
4.7 Expansion tank ...............................30
5 INSTALLATION ...........................31
5.1 Warnings .....................................31
5.2 Precautionsforinstallation ....................31
5.3 Installingtheboilersupport ...................32
5.4 Dimensions...................................33
5.5 Fittings .......................................33
5.6 Boilerassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.7 Controllingtheuegasexhaustduct ..........34
5.8 Fluegasdischargedimensionsandlengths ....35
5.9 Positioningofthedraftterminals ..............39
5.10 Electricalconnection..........................40
5.11 Connectinganambientthermostatorzone
valves ........................................41
5.12 Installingtheexternaltemperatureprobe .....42
5.13 Electricconnectionbetweentheboilerand
the external probe ............................42
5.14 Electricalconnectionoftheremote(optional) . 43
5.15 Remoteenablingofoperationwiththe
external probe ................................43
5.16 SettingtheKcoecientoftheexternalprobe . 44
5.17 Settingpumppost-circulation.................46
5.18 Selectingreignitionfrequency ................48
5.19 Examplesofhydraulicplantswithhydraulic
separator (optional) ...........................50
6 PREPARATION FOR SERVICE ..............51
6.1 Warnings .....................................51
6.2 Sequenceoftheoperations ...................51
7 CHECKING THE GAS REGULATION.........53
7.1 Warnings .....................................53
7.2 Operationsandgassetting....................53
7.3 Regulationoftheusefulpowerinheating
mode.........................................55
8 GAS CONVERSION........................58
8.1 Warnings .....................................58
8.2 Operationsandgassetting....................58
9 MAINTENANCE...........................60
9.1 Warnings .....................................60
9.2 Programmingthemaintenanceperiod ........60
9.3 Removingthebodypanels ....................61
9.4 Reinstallingthebodypanels ..................62
9.5 Emptyingthed.h.w.circuit ....................62
9.6 Emptyingtheheatingcircuit ..................62
9.7 Cleaningtheprimarycondensateexchanger
and the burner................................63
9.8 Checkthepressureintheheatingexpansion
tank ..........................................64
9.9 Cleaningthedomestichotwaterexchanger ...64
9.10 Controllingtheuegasexhaustduct ..........64
9.11 Checkingboilereciency .....................64
9.12 Checkingthecondensatedischargesiphon....65
9.13 Settingtheboilerchimneysweepfunction ....65
9.14 Settingsforchangingthecontrolcard .........67
Models Boiler certication code
RINNOVACOND25S M160.2025SM/...
RINNOVACOND35S M160.3035SM/...