READ AND SAVE THESE INSTRUCTIONS
Retain this installation guide for maintenance and troubleshooting.
WARNING: Do not strike, throw, or subject the battery to severe
physical shock.
WARNING: Do not attempt to disassemble or modify the battery in
any way.
WARNING: Do not place the battery in a microwave or pressurized
container.
CAUTION: Risk of fire and burns. Do not open, crush, heat above
140° F (60° C), or incinerate.
CAUTION: Do not use or store the battery near sources of heat
such as a fire or heater.
CAUTION: Do not use any chargers other than those
recommended.
CAUTION: Do not directly connect the battery to wall outlets or
car cigarette-lighter sockets.
CAUTION: Dispose of battery packs in compliance with local
regulations. Do not dispose as household waste.
CAUTION: Replace battery with BAS 006679 only.
QUESTIONS?
Customers in the United States
For questions about your product, contact a customer service representative
at 877-244-3267 or visit www.bigasslight.com/service
Customers outside the United States
For questions about your product, contact your local Big Ass Light
representative or fill out a contact form at www.bigasslight.com/service

WWW.BIGASSLIGHT.COM © 2017 DELTA T CORP. ALL RIGHTS RESERVED. 1
TECHNICAL SPECIFICATIONS
Light Bar
Model BAS-LTB1-0505
Weight (with battery) 4 lb 11 oz (2.13 kg)
Dimensions 23.6 × 2 in. (600 × 51 mm)
IP rating IP67
Battery and Charger
Nominal Voltage Average 14.4 VDC
Charging Voltage 16.4 VDC
Capacity 4,400 mAh
Standard Charge 2,200 mA at 32° to 113°F (0° to 45°C)
Discharge End Voltage 12 VDC
Power Supply 100–125 VAC, 50/60 Hz
Power Supply Cord Length 5 ft (1.5 m)
COMPONENTS
The battery must be installed and charged before using Light Bar.
A. Battery Test Button D. Minus Button
B. Diuser Lens E. Locking ring
C. Plus Button F. 1/4”-20 Threaded Opening
AB
C
EF
D

WWW.BIGASSLIGHT.COM © 2017 DELTA T CORP. ALL RIGHTS RESERVED.
2
Light Bar
Battery
Locked
INSTALLING THE BATTERY
To install the battery, insert the battery into the base of Light Bar, and then
rotate the locking ring until the indicator mark is above the “locked” icon.
Test operation by pressing the button
To remove the battery, rotate the locking ring to the “unlocked” icon, and
pull out the battery.

WWW.BIGASSLIGHT.COM © 2017 DELTA T CORP. ALL RIGHTS RESERVED. 3
USING THE LIGHT BAR
Plus button
Press once to turn on.
Press to increase brightness.
Press and hold to quickly bring the light to full brightness.
Minus button
Press and hold to turn o.
Press to decrease brightness.
Brightness levels
Level Brightness (lumens)*
180 lm
2 500 lm
3 850 lm
4 1500 lm
5 2800 lm
6 5000 lm
*All values approximate
Locking Ring
Turn clockwise to lock battery in place.
Turn counter-clockwise to unlock and remove battery.
1/4"-20 Threaded Opening
Attach eye hook for hanging or mount Light Bar to standard tripod.

WWW.BIGASSLIGHT.COM © 2017 DELTA T CORP. ALL RIGHTS RESERVED.
4
CHARGING
Charge the battery
To charge the battery, plug the charging station into AC power. Insert the
battery into the charging station so that it is tightly seated. The indicator
LEDs will flash to indicate the battery is charging.
• If the indicators do not flash, remove and test the battery. If all four
LEDs light up, the battery is fully charged.
• If three or fewer LEDs light up, make sure the battery is tightly seated
and the charging station is connected to AC power.
• If the LEDs still do not flash, contact Customer Service.
Charging
Station
Indicators Charge
One flashing 0–24%
One solid, one flashing 25–49%
Two solid, one flashing 50–74%
Three solid, one flashing 75–99%
Four solid* 100%
*If battery is fully charged, LEDs will illuminate only when test button is pressed.
Battery
Indicators Charge
Four solid 75–100%
Three solid 50–74%
Two solid 25–49%
One solid 10–24%
One flashing < 10%
Test Charge
Check charge level
Check the charge level by pressing the Test button.

WWW.BIGASSLIGHT.COM © 2017 DELTA T CORP. ALL RIGHTS RESERVED. 5
PREVENTIVE MAINTENANCE
CAUTION: Do not clean the fixture, especially the lens, with scouring
pads. Overexposure to certain chemicals such as toluene, acetone,
ethyl acetate, or ethylene dicholoride could cause damage.
Clean the light bar periodically with a damp cloth. Methanol, ammonia, and
n-hexane-based cleaners can be used on the lens without risk of damage.
TROUBLESHOOTING
If the ambient temperature is 113°F (45°C) or above, Light Bar may not
operate due to its electronics safety protection.
If Light Bar is not working, make sure:
• Battery is fully engaged with Light Bar and the locking ring locked.
• Light Bar is within its normal operational temperature range of -4°Fto
113°F (-20°C to 45°C).
• Light Bar buttons are operational (you should feel a slight recoil after
pressing).
If the battery is not charging when placed in the charging station, make
sure:
• The outlet is receiving power.
• The battery is fully inserted into the charging station.
• The charger is operational (check with another battery if possible).
• The battery and charger are not in a location where the temperature is
below 32°F (0°C) or above 113°F (45°C), or the battery will not charge.
In case of damage to a lens, contact 1-877-244-3267 for a replacement.
!

BAL-INST-162-MUL-01
REV. A
1 (877) BIG-FANS | WWW.BIGASSLIGHT.COM