Biontech BTM-303D User manual

* There is a protection lm on the control panel of this product.
* Please read each section thoroughly for proper unit usage.
* Keep the manual in a safe place and refer to it whenever needed.
* The manufacture and distribution company will not be held responsible for any
malfunction or accidents resulting from incorrect installation or improper handling.
BIONTECH Co., Ltd.
OPERATION MANUAL
Model : BTM-303D
BTM-303D (영).indd 1 2016-08-31 오후 1:26:05

Table of contents
Please have the Ionizer installed according to the directions in this manual.
It is advisable that a competent plumber perform the installation.
Installation and operation should be carried out in conformance with building and construction
codes, running water regulations and city ordinances.
During the nal inspection, be sure to check for leakage, ow rate and full operation of all functions.
After completing the installation, read the manual and take a pH measurement with supplied pH test
reagent drop (See Page 19).
Depending on local water quality, pH of the water may vary, particularly in areas where well water is
supplied as tap water.
2
1. Parts ............................................................................................................................................................
2. Name and description of each part ........................................................................................................
3. Safety preparations ...................................................................................................................................
4. Installing Your Ionizer ...............................................................................................................................
•Precautions for Installation..........................................................................................................................
•lnstallation Directions..................................................................................................................................
5. Prior to Use ............................................................................................................................................
•Precautions for using the product .............................................................................................................
•Using the product appropriately for each purpose .....................................................................................
•Directions for Storage and Maintenance After Use ...................................................................................
6. Producing Ionized Water ........................................................................................................................
•Selecting Alkaline Ionized Water ..............................................................................................................
•Selecting Acidic Ionized Water .................................................................................................................
•Selecting Puried Water ..........................................................................................................................
•Self Cleaning ...........................................................................................................................................
•pH(Ion Concentration) Measurement ......................................................................................................
7. Filter Replacement ....................................................................................................................................
•Filter Replacement Period .....................................................................................................................
•Filter Replacement Procedure ................................................................................................................
8. Using the Cleaning Filter ....................................................................................................................
9. Using Ionized Water..................................................................................................................................
10. Support ....................................................................................................................................................
•Questions and Answers (Q&A) .................................................................................................................
•About after service (A/S)...........................................................................................................................
11. Product Specications ............................................................................................................................
Table of contents
3
4
6
8
8
9
13
14
15
16
17
17
17
18
18
19
19
19
20
21
22
24
24
26
30
BTM-303D (영).indd 2 2016-08-31 오후 1:26:05

Parts
● The following components need to be checked before installation.
● The illustration shows basic components, their shapes may appear different
from the actual components
3
Diverter Valve(Optional) Adaptor(Small)
Flexible Alkaline Faucet
Wall-mountion Nails and Fuse
Hose
Hose Band Sagety Clip
Installation Drawing pH Comparison Sheet
Owner’s Manual
For Mounted Wall For Water Outlet
(Optional Item)
Acidic
Water
Outlet
pH Test Solution
Water Supply Valve Cover
X1 X1
X1
X2 X1
X1
2 Nails 2 Wall Plug
2 Screws 1 Fuse
Ø 7x9 PVC hose: 1m
1/4” standard hose: 2m (PE Reinforced hose)
X1
X1
X1
X1
Water outlet
x1
X1
X1
X2
● The supplied standard parts should be used, Installing parts that are not covered
in the warranty may be physically harmful and/or cause property damage.
* There is a protection lm on the control panel of this product.
* Please read each section thoroughly for proper unit usage.
* Keep the manual in a safe place and refer to it whenever needed.
* The manufacture and distribution company will not be held responsible for any
malfunction or accidents resulting from incorrect installation or improper handling.
BIONTECH Co., Ltd.
OPERATIONMANUAL
Model : BTM-303D
BTM-303D (영).indd 1 2016-08-26 오후 4:55:45
BTM-303D (영).indd 3 2016-08-31 오후 1:26:06

Front View
Bottom View
Rear View
4
Name and description
of each part
Acidic Water Outlet
Hose
Safety pin
Safety pin
For One-Touch
Fitting(1/4” X M10)
Tap Water
Hose
Safety pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Back Panel
Control Panel
Ionized Water Outlet
Fornt Panel
Filter Cover
Bottom Panel
Acidic Water Outlet
Water Inlet
Fuse Holder
Audio Speaker
Audio Volume Control
Water Supply Control Valve
Electric Cord
Wall-mounting Groove
Cover for circuit board and internal ionizer parts.
Function controls and display.
Outlet for either alkaline or acidic water (user-selected.)
Circuit apparatus and devices.
Filter protection cover.
Transformer,electric cord,and devices for xing parts.
Outow of acidic water(control of acidic water quantity).
Tap water supply.
For wall mounting using nails.
Fuse.
Voice and Melody.
Loudness control.
Ionizer operation and water ow adjustment(On/Off).
Electric cord for connecting with the electric wall socket.
.
Number Name Function
BTM-303D (영).indd 4 2016-08-31 오후 1:26:07

5
Control Panel
Alkaline Water
Indication Lamp
- Lights up when alkaline
water is selected.
Acidic Water
Indication Lamp
- Lights up when Acidic
water is selected.
Filtered Water
Indication Lamp
- Lights up when ltered
water is selected.
Cleaning
Indication Lamp
- Lights up while cleaning and
cuts off automatically when
nished.
Drain
Indication Lamp
- Lights up after cleaning
when water is draining.
[Puried Water]
Selection Button
- Selecting Puried
Water only.
[Acidic Water]
Selection Buttons
-Selecting Acidic water:
[ Acidic ]
Phone No.
to order lters
- service center
information
[Alkaline Water]
Selection Buttons
-Selecting Alkaline
Water
(Alkaline 1,2,3,4)
Error Indication
- Electrolyzer overheat
- Failure of cleaning
- Overow indication
Indication light for
ow volume.
High indication light.
Indicating when the ow
volume is higher than the
appropriate level
Standard indication light
Indicating when the ow
volume is normal, and the
indication level is varies
depending on the ow
volume
Low Indication Lamp
Indicating when the ow
volume is lower than the
appropriate level
Filter Life Indication
IMPORTANT:
When seeing 3.5 on the display and the melody is playing please do Not drink the water until the melody
stops playing or you select a different setting.
BTM-303D (영).indd 5 2016-08-31 오후 1:26:07

6
Safety Preparations
Description of the symbol marks
The following describes the precautionary items that can prevent the potential damage to the
body or the property. The cases of misapplication and resultant risks are divided into Warning
and Caution items. You are required to read thoroughly and comply with the descriptions
considering they are related to your safety.
-Caution - You should read the documents marked with the following symbols.
- Prohibition
- Instruction
Marks
Marks
Classication
Classication
Description
Description
●Indicates that deadly effect can be caused to the body if you use the product wrongly because of
your disregard for the items.
●Indicates the general items to be prohibited.
●Indicates the possibility of the product or components catching res due
to external sources of re.
●Indicates the possibility of the product causing electric shocks due to electric
leakage if it is submerged.
●Indicates the possibility of the product causing electric shocks if it is
disassembled
●Items related to the general behaviors of users.
●The plug needs to be disconnected from the wall socket if
there is a possibility of malfunctioning or lightening.
●Indicates that injury to the body or damage to the property can be caused. if you use the product
wrongly because of your disregard for the items.
Warning
Caution
General items to
be prohibited
Fire sources to be
prohibited
Showering to be
prohibited
Disassembly to
be prohibited
General
Disconnecting the plug
from the wall socket.
BTM-303D (영).indd 6 2016-08-31 오후 1:26:08

7
WEEE Directive
● Do not apply any different power voltage other than the indicated power voltage.
If not followed, res or electric shocks can be caused.
● Do not use any other fuse with different capacity.
● Stop using the product immediately when any malfunctioning is found.
● Do not handle the electric plug or operate the power button with wet hands.
If not followed, electrical shocks can be caused.
● Should hold the electric plug when inserting it into the wall socket or removing it from the socket.
● Damage to the electric cord, res or electrical shocks can be caused when if the cord is pulled.
● Clean the wall socket after removing the electric plug.
-When there are lots of dusts settled on it, re can be caused.
● Do not connect multiple cords to one single wall socket.
When a wall socket is shared, abnormal heat can be generated, possibly causing a re.
●
Electrical shocks, short-circuiting, ignition of res can be caused if a damaged electric cord or plug is used.
● Do not damage, process or forcibly wind or pull the electric cord.
-The cord can be damaged, possible leading to res or electric shocks.
● Do not x the electric cord by using a stapler.
-The cord can be damaged, possible leading to res or electric shocks.
● Electric shocks can be caused if the product is dropped into water by mistake.
The following measures need to be taken.
Remove the electric plug from the wall socket.
Recover the product from the water.
Contact the sales shop or the main ofce for advice.
● Should not arbitrarily modify, disassemble or repair the product.
If not followed, res and electric shocks can be caused.
The company will not be held responsible for any accidents generated from such activities.
- Warning - Should be followed for your safety.
BTM-303D (영).indd 7 2016-08-31 오후 1:26:08

8
Installing Your lonizer
Caution - Malfunction or accidents can be occured
● Do not place any other objects on the product.
● Do not install the product in the areas described as the following.
●If the product is dropped, electric shocks can be caused due to the internal malfunction following the
impact from the dropping. The product needs to be taken to the sales shop or the main ofce in order
for you to request an inspection.
●The purication lter can be broken due to freezing if the product is used in a place where it is freezing
cold, requiring the product, if not used, to be stored in a place where the breaking due to freezing can be
prevented, but after the purication lter is removed rst.
■ Installation Precautions
Caution
Reguiring you to check the rated voltage
before connecting the electric cord.
Should connect the product to the cool
water pipe (If connected to the warm
water pipe, the purication lter and the
electrolytic bath can be damaged)
Avoid any place where heat of re can be
directly contacted Do not modify the product arbitrarily.
Should hold the bottom plate of the
main case
Do not use the product in a place full
of moisture or dusts
■If not followed, the case can be
transformed, possibly leading to water
leakage
■If not followed, damage to the product or
risk to your safety can be caused.
■If not followed, the life span of the lter
will be shortened.
■It will be safe to move the product by
holding the product at the bottom plate.
■If not followed, damage to the product or
risk to your safety can be caused.
Do not install the product in a place where
the sunlight comes in directly or the
temperature goes below zero.
Precautions for connecting the acidic water
hose.
■If not followed, the case can be
transformed or broken due to freezing.
■Install the acidic water hose lower than the
main case.
■If the hose is longer than necessary or higher
than the main case, the ion generation can be
affected, possibly leading to a change in
the taste of water.
No warm water
BTM-303D (영).indd 8 2016-08-31 오후 1:26:08

9
●If the product is dropped, electric shocks can be caused due to the internal malfunction following the
impact from the dropping. The product needs to be taken to the sales shop or the main ofce in order
for you to request an inspection.
●The purication lter can be broken due to freezing if the product is used in a place where it is freezing
cold, requiring the product, if not used, to be stored in a place where the breaking due to freezing can be
prevented, but after the purication lter is removed rst.
■If not followed, damage to the product or
risk to your safety can be caused.
■Install the acidic water hose lower than the
main case.
■If the hose is longer than necessary or higher
than the main case, the ion generation can be
affected, possibly leading to a change in
the taste of water.
1. Disconnect the water tap from the water pipe.
2. Rotating the angle stop adaptor into the water pipe. (Single-water tap)
3. Assemble the water tap back into the adaptor. (Single-water tap)
4. Install the standard compliant adaptor between the water pipe and the water branch pipe.
Then install the which needs to be connected to the water ionizer to the cold water pipe, while
connecting the balancing adaptor to the warm water pipe. (Water taps for cold and warm water)
5. Place the rubber gaskets between the water pipes, water tap, and adaptor, and should
apply the Teon tape to the connection parts to assemble them.
6. Insert the inlet hose into the one-touch tting installed to the adaptor and then fasten the safety pin.
7. Adjust the water pressure control screw of the adaptor to a appropriate level
(Alkaline water ow standard: 1.5 ± 0.5 ℓ/min)
Should use the standard inlet hose (1/4”) and x the valve cover in the direction of the hose to
prevent the hose from being bent or the fastening nut from being loosened.
■ How to install
Caution
● Check whether the components to be installed at the water tap are appropriate.
● Should use the standard hose (1/4”), supplied by the company for the connection.
Use the one- touch adapter to fasten the hose before xing the safety pin as illustrated in Page 3.
- If the standard hose is not used, damage due to water pressure can be caused, possibly leading
to water leakage
● Do not connect the product to a warm water pipe.
- Degradation of purication capacity and malfunctioning can be caused.
Balance maintenance
water pressure control screw
water pressure control screw
Hot water
side
Cold
water
side
1. Wall mounted water tap
reducer tting
safety pins
safety pins
BTM-303D (영).indd 9 2016-08-31 오후 1:26:08

10
[Drawing 1]
[Drawing 2]
Place of hole drilled
6.
Connect the standard connection hose (1/4”) to the adapter
installed with one touch tting of union. (Drawing 3~4)
Insert the inlet hose into the one touch tting and insert
the safety pin as in drawing.
( Pls check if the hose has been securely tted to the end of one
thouch tting. if not, it causes water leakage for water pressure )
7.
After the connection, adjust the
water pressure control
screw
of the adaptor
to an appropriate level.
(Alkaline water ow standard : 1.5±0.5ℓ/min )
8. Check any possible water leakage at the connection parts
after the installation
Groover
Cold water
1. Prepare the tools for installation as drawing : Electric drill,
Hole cutter, Pipe wrench or spanner, General screwdriver,
Teon tape 1pc (Drawing 1.)
2. Turn off the water valves before installation under the
sinkdeck.
3. Disconnet the water tap from the cold water pipe.
4. Drill a hole for the 1/4” hose appropriate place
somewhere in sinkdeck and make the connection to the
inlet of the product
5. Find the cold water pipe inside the sink deck and connect
the adapter to the cold water pipe (Drawing 2.) ■Should use the standard inlet hose (1/4”) and x the
valve cover in the direction of the hose to prevent the
hose from being bent or fastening nut from being loosened.
[Drawing 4]
■ The following tools ate necessary for installation work
Pipe wrench
or spanner
General
screwdriver
Teon tape
Electric drill
Hole cutter
Size:
Diameter1/4”
2. Deck type sink mounted water tap
Hot water
Water valve of Cold water
Ring nut
Water pipe
Steel Hose
[Optional]
Acidic Water Outlet
Water pressure control
screw (Spindle)
Running water line
connection Adaptor(small)
[Drawing 3]
BTM-303D (영).indd 10 2016-08-31 오후 1:26:09

11
6.
Connect the standard connection hose (1/4”) to the adapter
installed with one touch tting of union. (Drawing 3~4)
Insert the inlet hose into the one touch tting and insert
the safety pin as in drawing.
( Pls check if the hose has been securely tted to the end of one
thouch tting. if not, it causes water leakage for water pressure )
7.
After the connection, adjust the
water pressure control
screw
of the adaptor
to an appropriate level.
(Alkaline water ow standard : 1.5±0.5ℓ/min )
8. Check any possible water leakage at the connection parts
after the installation
3. Diverter Valve
4. Hose Connected Method
How to assemble the valve to the faucet
After nishing of connection, cover the water supply valve cover part with screws again.
valve cover
Tap water Hose
Safety pin
Hose
Diverter
valve
Nut
Assembly method of valve
for Deck-sink water taps
▲Take the little screen out
▲Tighten the screws with screw
driver, after inserting the rubber seal
* Water ows into ionizer when the lever is turned to side
* Water ows down ward when the lever is turned to down
Cold water inlet Nut
Cold water inlet Nut Cold water inlet Nut
Screw
The Adapter Screw
The Adapter
▲
▲
▲Tighten the screws with
screw driver, after inserting
the rubber seal
▲Tighten the screws with
screw driver, after inserting
the rubber seal
BTM-303D (영).indd 11 2016-08-31 오후 1:26:10

12
Caution
● Do not install the product in the following areas:
- If not followed, malfunctioning can be caused.
•If vibration and impact can be fel
•If horizontality can not be acquired
•If direct sunlight comes in •If bathroom is installed or winds and rains can affect
•If there are lots of moisture or dust
•If there is a risk of breaking due to freezing
•lf heat of re can be felt
•lf damage can be caused to the product
● You are required to contact the sales shop or the specialized installer for queries when
you attach the product to the wall.
● Improper mounting may result in the product falling of, accident or mal-function.
Should use the standard inlet hose (1/4”) and x the valve cover in the direction of the hose to prevent the hose
from being bent or the fastening nut from being loosened. The safety pin needs to be inserted before using the
water.
●The product can be used conveniently by placing it on any place by applying the wall mounting or stand type
(Turn table) depending on the place of installation.
●After installation, connect the product to the power line.
●When the water ows through the product, the power will be turned on automatically. Then, select Puried
Water menu to enable the water branch pipe to open and close repeatedly to allow the water to ow for 2~3
minutes freely. Then push the pH button to set the desired concentration and compare it with pH comparison
sheet. The black water that will come out is the lter dusts owing with water, not dangerous to the body.
(Refer to How to measure the pH value in Page 18)
● First of all, assembling the flexible pipe to the half-moon shaped alkaline water outlet at the
upper part by turning it clockwise.
1. Measure the distance between the place for installation and the adapter installed to the water tap and then
cut the hose with an extra length.
2.Cut the PVC hose for the acidic water into the length of 50~70cm and place it lower than the product.
A) When installing the product onto the wall
● Apply water to the installation drawing and place it onto the wall
while keeping the horizontality
● Of those nailing positions at the width (1~3) or the height (2 ~4),
choose the convenient ones for driving 2 nails
● Place the hanging holes of the product onto the nails
:Positions of nails
1. Using Flat-head driver, adjust the loundness.
2. Screwing yellow nail to left, volume will be up.
Screwing it to opposite, Volume will be down.
B) When placing the product on the sink deck and its supports.
-Place the main case of the product on an appropriate position.
● When the above steps are nished, use the hose to connect the
valve cock of the adapter to the inlet pipe at the bottom of the
main case of the water ionizer
5. Steps for assembling the component before installing them
6. How to install in different places
7. Audio volume control
BTM-303D (영).indd 12 2016-08-31 오후 1:26:10

13
Important safeguards
Danger - To reduce the risk of electrocutions
Warning - To reduce the risk of burns, electrocution, re, or injury to persons
1.
the appliance is not to be used by children or persons with reduced with reduced physical, sensory or mental
capabilities,or lack of experience and knowledge, unless they have been given superviision or instruction
2. children being supervised not to play with the appliance
■ In case of power failures.
• Turn off the water branch pipe in case of power failures.
(When letting water ow through, puried water will come out)
• Use the product normally when the power is recovered.
■ In case of suspension of water supply.
• Do not use the product.
• Stop the water from owing through when the water supply is suspended in the middle of using the product
Prior to Use
8. In case of power failures or suspension of water supply
When the water supplied is resumed, let the water ow sufciently for direct water supply or showering in
order to help the inside air and other materials come out. Without going through such steps, the water still
can be used normally, but with the risk of drastic decrease of the life span of the lter when allowing air or
other materials ow through the main body.
Precautions for use
When using electrical products, especially when children are present, basic safety precautions
should always be followed, including the followung:
READ ALL INSTRUCTIONS BEFORE USING
1. Always unplug this product immendiately after using.
2. Do not use while bathing.
3. Do not place or store product where it can fall or be pulled into a tub or sink.
4. Do not place in or drop into water or other liquid.
5. Do not reach for a product that has fallen into water. Unplug immediately.
1. A product should never be left unattended when plugged in.
2. Close supervision is necessary when this product is used by, on, or near children or invalids.
3. Use this product only for its intended use as described in this manual. Do not use attachments
not recommended by the manufacturer.
4. Never operate this product if it has a damaged cord or plug, if it is not working properly,
if it has been dropped or damaged, or dropped into water.
Return the product to a service center for examination and repair
5. Keep the cord away from heated surfaces.
6. Never block the air openings of the product or place ot on a soft surface, such as a bed or couch,
where the air openings may be blocked. keep the air openings free of lint, hair, and the like.
BTM-303D (영).indd 13 2016-08-31 오후 1:26:10

14
•Do not hold up the main case while holding the outlet exible pipe. (Cause for breakage)
•Do not operate the strong alkaline ionized water (level 5) continuously for a long period of time.
If you use the product in such manner, the system protective circuit (Temperature sensor) may be started,
depending on the quality of water, and the electrolysis can be suspended.
When using the product in a place where the water hardness is high.
•Before using the water initially daily, push the acidic water button to allow the acidic water to ow
through for about 1 minute.
•In case of tap water, in places where the water is used a lot. You need to push the acidic water button one time
daily to allow the water to ow through for the manual rinsing. (By selecting the acidic water button).
In places where the water hardness is high or compounds of calcium are abundant, there can be white
sedimentation inside the case, requiring additional purifying system to be used depending the level of the
sedimentation.
Caution
Caution
Do not use the following water, as problems may arise:
- Turbid and contaminated water
- Water with high concentration of red rust
Do not use any substance other than the designated glycerate calcium (electrolysis-stimulating)
calcium) or calcium sulte (chlorine-neutralized) in the calcium container unless obtained from
ionizers.
Turn off the water supply valve when replenishing the calcium otherwise, water leakage
may result.
Check for secure connetion of the calcium container cap, to avoid water leakage.
●Use tap water only.
- This machine is manufactured for drinking water based on standard tap water.
●Do not use the following water, as problems may arise:
•Turbid and contaminated water •Water with high hardness
•Very salty water •Water with high concentration of red rust
●Do not ll the calcium container with no other substances than the designated.
- Glycerin acid calcium (Electrolysis facilitating calcium) or calcium sulte
(Removal of chloride.)
●Should turn off the water pipe when ling the calcium.
- If not followed, water leakage can be caused.
●Check where the calcium container cap is surely fastened.
- If not fastened surely, water leaksge can be caused when the water ows through.
Precautions for using the product
7. Never use while sleeping or drowsy
8. Never drop or insert any object into any opening or hose.
9. Do not use outdoors or operate where aerosol (spray) products are being used
or where oxygen is being administered.
BTM-303D (영).indd 14 2016-08-31 오후 1:26:10

15
•Do not hold up the main case while holding the outlet exible pipe. (Cause for breakage)
•Do not operate the strong alkaline ionized water (level 5) continuously for a long period of time.
If you use the product in such manner, the system protective circuit (Temperature sensor) may be started,
depending on the quality of water, and the electrolysis can be suspended.
When using the product in a place where the water hardness is high.
•Before using the water initially daily, push the acidic water button to allow the acidic water to ow
through for about 1 minute.
•In case of tap water, in places where the water is used a lot. You need to push the acidic water button one time
daily to allow the water to ow through for the manual rinsing. (By selecting the acidic water button).
In places where the water hardness is high or compounds of calcium are abundant, there can be white
sedimentation inside the case, requiring additional purifying system to be used depending the level of the
sedimentation.
●Use tap water only.
- This machine is manufactured for drinking water based on standard tap water.
●Do not use the following water, as problems may arise:
•Turbid and contaminated water •Water with high hardness
•Very salty water •Water with high concentration of red rust
●Do not ll the calcium container with no other substances than the designated.
- Glycerin acid calcium (Electrolysis facilitating calcium) or calcium sulte
(Removal of chloride.)
●Should turn off the water pipe when ling the calcium.
- If not followed, water leakage can be caused.
●Check where the calcium container cap is surely fastened.
- If not fastened surely, water leaksge can be caused when the water ows through.
Use the product appropriately for each purpose
pH level selection Indicated
pH value instructed
10.0 ±0.5
Alkaline 4
Alkaline 3
Alkaline 2
Alkaline 1
Puried
Acidic
•When infusing vegetables to remove their bitter taste
•When washing vegetables
•Use it for drinking after consulting the doctor
•Recommendable for medical and culinary usage
•Recommendable for drinking and cooking
•Recommendable for daily drinking
•Recommendable for initial drinking or dissolving
powdered milk
•For washing dishes
•Strong acidic sanitary or rinsing water can come
out when the water volume is adjusted
•Rinsing with Acidic water to eliminating Viruses Bacilli
The pH value instructed is acquired by taking into consideration the source water based on Seoul, Korea
(Concentration of pH 7.0 ± 0.5, the water ow standard of 1.5ℓ/m (±0.5ℓ).
The pH values of the alkaline and acidic ionized water may not fall into the range of the pH value
instructed of the table above depending on the water quality and water ow volume.
9.5 ±1.0
9.0±1.0
8.5±1.0
3.5+1.0
▲
High
|
|
Alkalinity
|
|
Low
|
|
Acidity
|
|
High
▼
Caution - Usage of the product
● Do not use ammable materials like benzene or sprays for the product.
- Malfunctioning can be caused.
● Sufcient attention needs to be paid when a child of young age uses the product.
● Run tap water for 10 to 15 seconds prior to initial ionizer use each day.
● If ionizer is not used for several days, run water for at least 30 seconds prior to use.
● Contact the sales shop or the main ofce for advice when the generated water smells.
● Do not drop the product or apply strong impact to it.
- Dropping or impact can cause malfunctioning.
● Do not block the water outlet. If blocked, water leakage or malfunctioning can be caused.
● Should place the outlet hose (Acidic water outlet) below the main case.
● Do not use the water which is above 30°C (86°F) If not followed, malfunctioning can be
caused.
BTM-303D (영).indd 15 2016-08-31 오후 1:26:10

Should keep the water ow volume at an appropriate level in
order to prevent the alkaline ionized water from being
generated with difference in the pH value compared with
the set pH value due to the difference in the water ow volume.
Do not use the product in a place, like a bathroom, where
temperature or humidity is high.
Use the product in a place where there is no slope.
16
Directions for Storage and Maintenance After Use
Turn off the power before moving the product
Do not let water come inside the main body.
Do not block the outlet nozzle or the drainage hose arbitrarily. Do not bend or twist the hose arbitrarily.
Turn off the source water supply valve when the system will not be used for a long period of time.
Disconnect the electric cord from the wall socket when the system will not be used for a long period of time.
Clean the surface of the main body with soft cloth soaked with soap water.
1. How to store and manage the product after using it.
2. Precautions for using it.
(1) Precautions to be taken when using the ionizer.
(2) Pay attention to the following items regarding the
use environment and conditions.
Cap
Non-woven fabric
UF Membrane Filter
General activated
carbon
Water Outlet
General activated carbon
Calcium sulte
Remarks
Place of origin
Korea
Classication
UF Membrane Filter Special Fiber Pad
Non-woven fabric
●Pay attention to the following items when drinking the alkaline ionized water generated through the electrolysis.
Consult a doctor before drinking the strong alkaline water of level 5.
Those people with achlorhydria need to take the advice from a doctor for drinking the treated water
Do not use any type of water that can not meet the water quality requirements for the drinking water
The product is designed exclusively for the water of normal temperature, so warm water should not be used.
Do not drink the alkaline ionized water together with medicine.
Those people who just started using the water need to begin with small amount of nearly pH neutral water. They need
to consult a doctor for drinking the strong alkaline water.
Stop drinking the water and consult a doctor if you feel abnormality after drinking the water, or if there is no alleviation
of symptoms felt in the stomach even after continuously drinking the water.
Those people who currently go through medical treatment need to consult a doctor before drinking the water.
Those people with problems with the kidney, such as renal failure, calcium excretion failure, should not drink the water.
Those people who drink the alkaline ionized water need to check, once a month since after the initial drinking, whether the
pH value is still within the range for drinking, through utilizing a glass electrode type pH device or colorimetry before
they continue to drink the water.
Drink after the initial alkaline water ows through.
Avoid any metal container if possible and drink the water within a day while keeping it cold.
BTM-303D (영).indd 16 2016-08-31 오후 1:26:10

17
Operation indication panel Alkaline Level Buttons
Alkaline Level Buttons
Indication of operation
in progress
Indication of operation
in progress
Selecting Alkaline lonized Water
Selecting Acidic Ionized Water
1. Open the water supply control valve to let the water
ow in.
2. Use the pH button to select a stage.
- The value of selected pH stage is indicated.
- In case of"alkaline", any value between stage 1~4
will be indicated.
- When normally started, the system provides the
alkaine ionized water with previously set alkaline
value.
3.The product is ready to used.
Voice guidance:"Alkaline lonized Water on Process."
■ When the water supply control valve is turned off after
selecting and using "Strong""alkaline",the setting
will return to the previously set value of "Alkaline".
■ Do not use the product in the "Strong alkaline" state
for a long period of time.
The power can be turned off due to the operation of
the system protective circuit depending on the
quality of water.
■ Indication light for water inow.
When the tap water ows in, the water inow indication light indicates 'L' when the water
pressure is low and 'H' when it is high.You are required to adjust and keep the water pressure
to make the indication light stay at the center of "NORMAL".
When the indication light stays at the standard level, about 1.5l+ 0.5l/min.
of water will ow through.
_
When the acidity pH selection button for the operation is pushed, the acidic
ionized water will ow through the alkaline ionized water outlet.
1. Open the water supply control valve to let the water ow in.
2. Use the acidity pH selection button for selecting
(Melody comes out while the product is being used)
Voice guidance: "Acidic lonized Water on process."
3. When the water supply control valve is turned off in the middle of the
water being used, the setting will return to the previously set
value of 'Alkaline'. In order to stop the operation in the middle of the use,
other selection buttons need to be pushed to select other functions.
Producing lonized Water
BTM-303D (영).indd 17 2016-08-31 오후 1:26:11

18
Caution
● Acidic ionized water is not for drinking, so do not drink it.
● Use the water after letting the water ow through for about 5 seconds right after the generation
is initiated.
● Use the water initially daily after letting the water ow through for 10 ~ 15 seconds by opening
the water tap completely
● Use the water after letting the water ow through for more than 30 seconds when using the
product after not using it for a few days.
● Should not remove the purication lter when letting the water ow through the main case.
● Do not drink the acidic water.
Puried water indicating button
Indication of operation in progress
Indication of operation
in progress
1. Open the water supply control valve to let the water ow in to generate
the alkaline ionized water of the set value.
2. Push the puried water indicating button.
- Indication light for puried water selection
Voice guidanc "Crystal clear water on precess"
3. Use the puried water.
4.When the water supply control valve is turned off in the middle of
the water being used, the selection of the puried water is called
off and the setting will return to the previously set value of Alkaline .
In order to stop the operation in the middle of the use, other
selection buttons need to be pushed to select other functions.
■ When the indication light for the puried water is turned off.
When there is a change in the water pressure leading to the lowering
of the water level, the indication light will be turned off and the setting
will be returns to the previously set value of ‘Alkaline’. Use the
product by setting the value again after adjusting the water pressure.
Automatic Self-Cleaning inside the main body will be performed in the following cases in order for the cleaning of the
electrolysis bath and sustaining of water generation function.
■Do not let the water ow through while the rinsing is progressed .
(Err 7 will be indicated if the water is allowed to ow through)
■ When the rinsing is in progress, the indication light will be blinking
and the melody will be heard.
The rinsing process will be repeated until the Self-Cleaning is
completed if the water is allowed to ow through while the rinsing
is progressed.
■ Even when there is more than 10ℓ of water owing through, the automatic
rinsing will not be performed if an operation is in progress. The automatic
rinsing will be performed when the water stops owing through.
Please take note
- There can be ‘water dripping’ from the outlet pipe in the middle of the rinsing process,
which is not an abnormal situation.
- The operation will stop automatically when the indication light for the rinsing is turned off after the rinsing is nished.
Voice guidance:“ Self Cleaning.”
Selecting Puried Water
Self Cleaning
When the water ow volume of the
alkaline or acidic ionized water
reaches about 10ℓ.
Rinsing will be performed for about
30 seconds after the water supply
control valve is turned off.
When the water supply control valve is
opened after the rinsing, about 0.2ℓ of
water will be drained.
BTM-303D (영).indd 18 2016-08-31 오후 1:26:12

The pH values (Ion concentration) of the generated alkaline or acidic ionized water can be measured.
■ Check the generated water after adjusting the water pressure to meet the standard water ow volume (1.5
l
+ 0.5
l
/Min.)
according to the ionized water generation method.
(The pH values can vary depending on the quality of water and the ow volume)
■ Materials to be prepared: The pH Reagent - parts
■ How to measure
1. Let the generated water (Alkaline or Acidic ionized water) ow through for about 10 seconds.
2. After lling a transparent glass with 1/3 of the water, put 2~3 drops of the pH reagent into the water and shake it.
3. Compare it with the pH colorimetry.
Please take note
■ The color of the test solution will change as time goes by. (Compare the color of the test solution with the pH colorimetry
before too much time passes by after dropping the test solution into the water)
■ When disposing of the undiluted test solution, you need mix it with water to make it light before letting it ow out.
■ When the pH concentration is measured, the color of the test solution can come out differently compared with the pH
colorimetry due to the effect of various substances dissolved in the water such as carbonic acid gas.
■ The pH color of the alkaline or acidic ionized varies depending on the pH level.
19
Caution
Caution
● Do not let the pH regent contact the eyes and do not drink it.
- In case of drinking it by mistake, you need to drink lots of water. In case of the test solution contacting
the eyes, you need to clean your eyes with sufcient water and then consult a doctor.
● Do not place it near any heat of re. If not followed, re can be caused.
● Do not store the regent in a place where it can be reached easily be children. Avoid any place where
the temperature or moisture level is high
pH (ion concentration) Measurement
Indication light for water draining
Filter Replacement Period
Indication for lter replacement
The pH test solution is an expendable item. It can be purchased at the sales shop or the main ofce.
Indication of operation
in progress
Indication of operation in progress
1. Open the water supply control valve to let the water ow in to generate
the alkaline ionized water of the set value.
2. Push the puried water indicating button.
- Indication light for puried water selection
Voice guidanc "Crystal clear water on precess"
3. Use the puried water.
4.When the water supply control valve is turned off in the middle of
the water being used, the selection of the puried water is called
off and the setting will return to the previously set value of Alkaline .
In order to stop the operation in the middle of the use, other
selection buttons need to be pushed to select other functions.
■ When the indication light for the puried water is turned off.
When there is a change in the water pressure leading to the lowering
of the water level, the indication light will be turned off and the setting
will be returns to the previously set value of ‘Alkaline’. Use the
product by setting the value again after adjusting the water pressure.
When the water supply is opened after the rinsing is nished, the indication light
for water draining will blink automatically together with a voice guidance. After
about 0.2ℓ of water is drained the indication light will be turned off, and the
setting will return to the previously set value of ‘Alkaline’ for the
operation. (Do not drink the drained water )
Voice guidance :“ Drain out, wait for a moment please.”And when the draining is
nished, there will be a voice guidance will say“ Alkaline Ionized Water on process.”
■ In the following cases, the replacement period can be shortened drastically:
● When there is rusty water due to aged pipes
● Lots of impurities in the water for a short period of time
● If the product is used in a place where the water pressure is low.
■ When the water tastes changes or the water ow volume decreases dramatically,
you need to check whether the life span is overdue.
■ When the lter usage status indicating number becomes "999" , it will blink.
It is recommended to replace the lter even before the end of life span is
reached, if the water smells or the water ow volume decreases, considering the
life span can be different depending on the quality of water in individual areas
Service Call : 82-1644-3853
When the water supply control valve is
opened after the rinsing, about 0.2ℓ of
water will be drained.
Filter Replacement
BTM-303D (영).indd 19 2016-08-31 오후 1:26:12

20
(Picutre 1)
(Picutre 4)
(Picutre 2)
(Picutre 5)
(Picutre 3)
(Picutre 6)
The lter without our company logo is not a genuine product. When a genuine lter is not used, the quality cannot
be guaranteed and the normal after sales service(A/S) will not be available.
How to replace the lter
■ Do not disconnect the electric plug.
(When the plug is disconnected, the system can be restored when the lter connector is inserted)
1.Open the cover and remove the lter. (Picutre1~3)
■ Be careful of the possible water coming out of the lter. (It is not leakage)
2.Replace with a new lter. (Picture 4)
■ Remove the sealing sticker of the lter.
■ Check whether the O-ring is attached well at the bottom of the new lter rst. Then, place the lter into the hole securely
and turn it clockwise to insert it into the connection part. If a unbranded lter is installed, there will be a voice
guidance saying “Filter rejected, mount correct one.”, and the power will be turned off after 20 seconds.
3.Let the water ow through after selecting the puried water function.
■ Let the water ow through for about 2~3 minutes.
(Dusts of activated carbon which is the ltering medium may ow with water during the initial ow after the
lter is replaced.)
■ Check whether there is any water leakage at the installation section of the lter.
4.Insert the lter connector into the corresponding port (Picture 5)
■ Check whether the lter usage status indicating number becomes [000].
5.Close the cover. (Picture 6)
Please take note
■When you get the alkaline ionized water in a cup after the lter is replaced, there can be white bubbles.
which are not abnormal.
■The ion concentration (pH value) can become slightly higher after the lter is replaced (For about 1 week).
That is not abnormal.
Follow the steps mentioned above even when replacing the lter earlier than the time for the replacement.
BTM-303D (영).indd 20 2016-08-31 오후 1:26:13
Table of contents
Popular Other manuals by other brands

Oase
Oase AquaOxy 500 operating instructions

Vetus
Vetus SMTO2S Operation manual

Kaiser Baas
Kaiser Baas VR-X quick start guide

Giesemann
Giesemann TESZLA operating manual

Reelcraft Industries, Inc.
Reelcraft Industries, Inc. 3900 SERIES Operation manual

Securitytronix
Securitytronix ST-PTZMINI-10XTA installation manual