STEP 1 - What’s Included
• ICD114A, ICD115A, ICD116A Industrial Opto-Isolated
Serial to Fiber Converter
• Specifications Manual
• Control Wiring Diagram
• This Quick Start Guide
USER-SUPPLIED COMPONENTS
• 10 to 48 VDC power supply; this converter draws a
maximum of 2.3 Watts. Black Box recommends a
120 VAC/12 VDC Wallmount Power Supply with Bare
Leads (PS1003).
STEP 2 - UL
®
Class 1 / Division 2 Information
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND
D HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS
ONLY.
CONVENANT À L’EMPLOI DANS LES SITES DANGEREUX DE
CLASSE I, DIVISION 2, GROUPES A, B, C ET D, OU DANS LES SITES
NON HASARDEUX SEULEMENT.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY
COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
ATTENTION - DANGER D’EXPLOSION - LA SUBSTITUTION DE
COMPOSANTS PEUT ENTRAÎNER UNE ADÉQUATION À LA
CLASSE I, DIVISION 2.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA
IS KNOW TO BE FREE OF IGNITABLE CONCENTRATIONS.
ATTENTION - DANGER D’EXPLOSION - LA SUBSTITUTION DE
COMPOSANTS PEUT ENTRAÎNER UNE ADÉQUATION À LA
CLASSE I, DIVISION 2.
FIELD WIRING CONNECTIONS MUST BE MADE USING 105 °C
MINIMUM COPPER SUPPLY WIRES.
LES CONNEXIONS DE CÂBLAGE SUR SITE DOIVENT ÊTRE
RÉALISÉES EN UTILISANT DES CÂBLES D’ALIMENTATION EN
CUIVRE DE 105 °C MINIMUM.
TO BE INSTALLED IN ACCORDANCE WITH CONTROL
DRAWING 8510R001.
POUR ÊTRE INSTALLÉ CONFORMÉMENT AU DESSIN DE
CONTRÔLE 8510R001.
UL CLASS 1 / DIVISION 2 WARNING INFORMATION
POWER, INPUT/OUTPUT (I/O) WIRING FOR THE
END-USE ENCLOSURE MUST BE IN ACCORDANCE
WITH CLASS 1 DIVISION 2 WIRING METHODS
(ARTICLE 501.10(B) OF THE NATIONAL ELECTRIC
CODE, NFPA 70) AND IN ACCORDANCE WITH LOCAL
AUTHORITIES.
LE CÂBLAGE D’ALIMENTATION, D’ENTRÉE / SORTIE
(E / S) DE L’ENVELOPPE D’UTILISATION FINALE DOIT
ÊTRE CONFORME AUX MÉTHODES DE CÂBLAGE DE
CLASSE 1, DIVISION 2 (ARTICLE 501.10 (B) DU CODE
NATIONAL DE L’ÉLECTRICITÉ, NFPA 70) ET AUX
AUTORITÉS LOCALES.
THE MAXIMUM AMBIENT AIR TEMPERATURE IS 185°
F (85° C).
LA TEMPÉRATURE MAXIMALE DE L’AIR AMBIANT
EST DE 185 °F (85 °C).
THESE DEVICES MUST BE INSTALLED IN AN END-
USE ENCLOSURE SUITABLE FOR THE LOCATION.
CES DISPOSITIFS DOIVENT ÊTRE INSTALLÉS DANS
UNE ENCEINTE D’UTILISATION FINALE ADAPTÉE À
L’EMPLACEMENT.