Blonder tongue NXG SYSTEM KIT User manual

BLONDER TONGUE LABORATORIES, INC. |ISO 9001:2015 CERTIFIED |WWW.BLONDERTONGUE.COM
QUICK GUIDE
NXG PLATFORM
Rev: 120722 P/N: 651247000A
All Rights Reserved. Specifications subject to change without notice.
All trademarks are property of their respective owners.
NXG SYSTEM KIT
QUICK SETUP AND CONFIGURATION
MODULAR IP DIGITAL VIDEO PLATFORM
STOCK # MODEL NAME DESCRIPTION
6780 NXG-MFR Mainframe - 5RU Chassis; 12 Module Slots; 60 Gb Capacity Backplane with
Fans & Air Filter
6781 NXG-CNTRL Master Controller Module - Controls Entire Platform
6782 NXG-PS Power Supply - (2) Required for Redundancy

2NXG SYSTEM
Quick Guide
© BLONDER TONGUE LABORATORIES, INC. ALL RIGHTS RESERVED ISO 9001:2015 CERTIFIED | WWW.BLONDERTONGUE.COM | 800-523-6049
PRODUCT INTRODUCTION
The NXG System Kit is a powerful, two-way, future-proof platform that is ideal for delivering next generation
video services to enterprise locations including hospitality, educational, multifamily residential, healthcare,
business parks, or stadiums.
NXG Platform Base - Master Controller Module, Mainframe, and Power Supplies provides:
▶IP routing and trac management
▶System conguration and management via a powerful Linux-based monitoring and control system
▶Module interconnection via a 30 Gb high-speed backplane
▶Distributes DC power to the various sections and modules via (2) fully-redundant, hot-swappable power
supplies
The NXG is designed to be installed in a standard 19" rack. Up to 12 Modules, along with the required
Master Controller and Power Supply Modules, can be installed into a single NXG Platform Mainframe.
Adequate ventilation is very important in NXG Chassis installations. The chassis airflow is from front to
back. Some air movement is advisable in enclosed rack cabinets as excessive heat will shorten the life
of components and individual module(s). Power supply performance will also be degraded without proper
ventilation.
Mount the 5 RU NXG Chassis into the 19 inch rack using rack screws (not provided).
Install the Air Filter in the bottom of the chassis, if not installed already, and tighten the screws.
1
2
BEFORE YOU BEGIN: UNPACKING THE PLATFORM
STEP 1: SETTING UP THE MAINFRAME
Included with the Chassis:
▶Anti-static wrist strap (QTY=1)
A NOTE OF CAUTION! PLEASE READ
Modules are user-installed with circuit boards that have exposed parts and contacts. In order to prevent possible
damage, first install the chassis into a grounded equipment rack, attaching the provided wrist strap to the chassis
and your wrist. Once grounding is complete, you can safely remove the modules from their anti-static bags.
A NOTE OF CAUTION! PLEASE READ
Blank panels MUST be installed in all the unused slots in the chassis to ensure proper cooling and airflow.
▶NXG Chassis (QTY=1) ▶10 blank panels (QTY=2 bags of 5 each)

3NXG SYSTEM
Quick Guide
© BLONDER TONGUE LABORATORIES, INC. ALL RIGHTS RESERVED ISO 9001:2015 CERTIFIED | WWW.BLONDERTONGUE.COM | 800-523-6049
2
1
5
10
3
8
6
11
4
9
7
12
AIR FILTER
MODULE SLOTS
MC
PS 2
PS 1
MAINFRAME CHASSIS
MASTER CONTROLLER
POWER SUPPLIES
Tab LEDs
STEP 2: CONTROLLER & POWER SUPPLY INSTALLATION
Locate the Power Supplies (sold separately) and face each power supply module in the correct position
to be inserted into in the PS 1 and PS 2 slots (shown above).
To properly install, the LEDs and green tab MUST be positioned towards the bottom (shown above). Slowly
push the module into place until you hear a click. Once done, proceed with the second power module
the same way.
Connect the AC power cord to each power supply and to an appropriate 120-240V, 50/60Hz AC power
source.
1
A NOTE OF CAUTION! PLEASE READ
When inserting the power modules into the chassis, the green tab MUST be located on the bottom left side
(shown above). Slowly push the module into place until you hear a click. If installed upside down and pushed
in forcefully, the modular unit(s) MAY become damaged.
Install the Master Controller (sold separately) by sliding the module into the card slot on the far left
within the chassis.
2
IMPORTANT
The Master Controller (MC) module MUST be installed in the empty slot as directed in #2.
The system will not work if the MC module is installed into any other slot.
STEP 1: SETTING UP THE MAINFRAME (CONTINUED)

4NXG SYSTEM
Quick Guide
© BLONDER TONGUE LABORATORIES, INC. ALL RIGHTS RESERVED ISO 9001:2015 CERTIFIED | WWW.BLONDERTONGUE.COM | 800-523-6049
STEP 2: CONTROLLER & POWER SUPPLY INSTALLATION (CONTINUED)
3Install the appropriate input and output modules for your NXG application in any of the 12 slots. When
possible space the input and output modules apart to maximize airflow.
REMINDER
Before NXG-CCQD-24 module installation, don’t forget to insert the CableCARDs into the module. Please see
the NXG-CCQD-24 user manual for more information on installation.
STEP 3: CONNECTING TO A PC/LAPTOP
Plug one end of the Ethernet cable into Port 1 on the NXG Master Controller front-panel interface. Plug
the other end of the Ethernet cable to your computer.
The factory default IP address of the NXG Master Controller management port is 172.16.70.1. To be able
to communicate with the NXG Master Controller management port, you must first change your computer's
IP address.
1
2
The following steps explain how to do this for a computer with Windows 7, 8.x, 10, or 11 operating
software:
(a) On your computer, navigate to the “Network and Sharing Center”.
(Note: Can be found using the search box in the Start Menu or for Windows 8.x, the Start Screen)
(b) Once open, click on “Change Adapter Settings” on left hand side of the window.
(c) Right-click on the “Local Area Connection”, and then click on the “Properties”.
(d) A dialog box entitled “Local Area Connection Properties” will appear. In this box, double-click on the
“Internet Protocol Version 4 (TCP/IPv4)”.
(e) A dialog box entitled ”Internet Protocol Version 4 (TCP/IPv4) Properties” will appear. Select the “Use
the following IP address” option and enter the following addresses:
▶IP address: 172.16.70.2
▶Subnet mask: 255.255.255.0
▶No need to enter a value for the Default Gateway.
Click OK to close the dialog box. Your computer is now ready to communicate with the unit.
ETHERNET ACCESS:
Local or remote communication with the unit is only possible through a GUI-based menu via any standard
web browser. Before you can communicate with the unit, you must configure your computer's IP address
to be in the same subnet as the units default IP address. To do so, follow these steps:

5NXG SYSTEM
Quick Guide
© BLONDER TONGUE LABORATORIES, INC. ALL RIGHTS RESERVED ISO 9001:2015 CERTIFIED | WWW.BLONDERTONGUE.COM | 800-523-6049
STEP 4: LOGIN TO THE CONTROLLER
STEP 5: BASIC CONFIGURATION
An ethernet cable should be connected between your PC and “Port 1” on the Master Controller. Open a
Web browser (Chrome or Firefox recommended) and type in http://172.16.70.1 to your web browser.
You can now view and configure your NXG platform. Enter the default username and password and click
[LOG IN]. The factory default values for the unit login are:
Once logged into the NXG, you will be presented with the “System Status” page (“Status” tab):
▶IP Address: 172.16.70.1
▶Subnet Mask: 255.255.255.0
▶Username: Admin (case-sensitive)
▶Password: pass (case-sensitive)
PLEASE NOTE
Additional information about the unit IP and login credentials setup can be found in the user manual.

6NXG SYSTEM
Quick Guide
© BLONDER TONGUE LABORATORIES, INC. ALL RIGHTS RESERVED ISO 9001:2015 CERTIFIED | WWW.BLONDERTONGUE.COM | 800-523-6049
STEP 5: BASIC CONFIGURATION (CONTINUED)
Go to the “System” tab to change the System Settings. Some settings that can be configured here are
Command/Control Ethernet Settings, User Interface IP Access Restriction List, SSL Key/Certificate, and
IP I/O settings for the Master Controller front-panel ports.
Click “Apply” in order to save the new settings.
REMINDER
If the IP Address is changed, the procedure in Step 4 must be repeated using the new IP address in place of
the default IP address in order to reaccess the control panel.
STEP 6: MODULE CONFIGURATION
After the hardware installation of any additional modules, go through the control panel and set up each
module slot to configure your NXG application. Please refer to the user manuals of each module for in-
depth configuration.
MODULE SLOT TABS
ACCESSED HERE

7NXG SYSTEM
Quick Guide
© BLONDER TONGUE LABORATORIES, INC. ALL RIGHTS RESERVED ISO 9001:2015 CERTIFIED | WWW.BLONDERTONGUE.COM | 800-523-6049
TROUBLESHOOTING
For any additional technical support issues, please send more information to us about your issue via our
website at www.blondertongue.com/support/ or call us toll-free at 1-800-523-6049 between the hours of
8:00 AM and 5:00 PM (EST, UTC -5).Please refer to the operation manuals of each module for additional
information.
RETURNING PRODUCT FOR REPAIR (OR CREDIT)
A Return Material Authorization (RMA) Number is required on all products returned to Blonder Tongue,
regardless if the product is being returned for repair or credit. Before returning product, please review our
return policies or contact our service department for further information.
CROSS-REFERENCE & HYPERLINKING USAGE
This guide makes use of hyperlinks for the Table of Contents, some cross-reference linking between
sections, and external hyperlinking to web addresses. This has been done to assist the reader in finding
the information they are seeking in a much quicker way. In addition to hyperlinking, the Table of Contents
also makes use of the bookmarking feature present in the Adobe Reader application.
PRODUCT AND DOCUMENTATION UPDATES
The latest user documentation (PDF) and Firmware Updates can be obtained by visiting our website.
Navigate to the product page by entering the full Model Name in the search field. Firmware Updates can
also be directly accessed under the “Support” section of the website. If you cannot find your product
model on the website, please reach out to Tech Support through our support request form.
FILTER MAINTENANCE
The polyester element of the filter may be washed in warm soapy water, vacuumed, gently blown out
or replaced. Use a mild detergent like Dawn liquid soap. The element should be completely dry before
reinstallation. The element should be replaced after a maximum of three cleanings.
IMPORTANT
The air filter in the chassis MUST be cleaned or replaced every six months to prevent particulate build-up that
will reduce the cooling capability of the unit. If a unit is installed in an environment that has increased levels
of dust or other airborne particles, air filter maintenance should be performed more frequently.