Intab SMS alarm User manual

www.intab.se • [email protected] • +46 302-24 600
Gjutarevägen 1 • 443 61 Stenkullen
SMS alarm
L-52
2014-06-12

1. Description
A1400 is a simple & easy to use GSM Temperature Detector which sends SMS you in case of alarm events. Alarm
event occurs in case of Low or High Temperature threshold values are exceeded and restored. Also occurs with
the Cable Fault. Up to 3 users can be registered.
Only a local GSM SIM card is required to operate the device.
A1400 operates with both batteries and power adaptor.
A1400 also operates as Power Failure Detector. Sends you POWER FAIL message in case of power adaptor fails
and sends you POWER OK message in case of power restored.
Once battery is low, device sends you LOW BATTERY message and sends you weekly KEEP ALIVE messages.

2. Getting started
2.1. Insert SIM Card
A local SIM card is required to operate the system. Before inserting the SIM card, try it with a mobile phone and:
• Disable PIN code protection
• Send an SMS to a mobile number for testing
After above steps; please open the screws on the back of the item and please insert SIM card into your device.
2.2. Connect Digital Temperature Probe
Connect RED wire of temperature probe to the terminal block 3.
Connect WHITE wire of temperature probe to the terminal block 4.
Please pay attention to the wires connection to avoid device damages.
2.3. Connect Power
(GND).
Please note power adaptor current should be at least 1500 mA.
-
ries only).
2.4. Register Admin Number
The LED will blink a few times until it is connected to an available network. Please wait for LED becomes solid ON.
Once LED is ON; that means device is connected to a GSM network and ready to work.
Now please call the device’s number with your phone. Once you hear the ringing volume, your number is registe-
red to devices memory as ADMIN NUMBER.
Then the LED will blink and device will send you an SMS including “ADMIN OK” message. After you receive this
message; please wait for LED becomes solid ON again. If done; you ready for next step.

THE LIST OF COMMANDS (table 1)
DESCRIPTION COMMAND DEFAULT
Change password NEWP:XXXX 1111
Add / change user 1 TEL1:+XXXXXXXXXX
Delete user 1 DEL1
High temp. value (°C)
DIGITS)
+30
Low temp. value (°C)
DIGITS)
+00
Enable Keep Alive ENABLE Enable (weekly)
Disable Keep Alive DISABLE Enable (weekly)
Reset device RESET
2.5. Send Configuration Commands
There should be a space character between independent commands e.g.: 1111<space>NEWP:1234<space>DEL1<spa
ce>DISABLE
LED will become OFF.

EXAMPLES:
1) QUICK CONFIGURATION:
1111
the device; it will reply you with an SMS including “CONFIG OK <XX>, TEMPL <LL> TEMPH <HH>” text (where XX
Now LED will turn off and your device is ready to operate.
2) EXTENDED CONFIGURATION:
Above example means:
future. Please note it carefully.
•
•
• High temperature is changed to +60 0C.
• Low temperature value is factory default: +00 0C.
Once you sent this SMS to your device, it will reply you with an SMS including “CONFIG OK <XX>” text (where
operate.
<XX> BETYDELSE RÅD
Between 19-31 Excellent signal
Between 14-18 Good signal
Between 9-13 Workable signal Try changing location
Between 1-8 Weak signal Check antenna / change device
location
99
SIGNALSTYRKA - GSM (tabell 2)

Now your device will continuously check for:
•
• Temperature Restorations
• Temperature Probe Cable Fault
• Power failure and restorations
• Low battery
• And keep alive message periods
In case of any temperature alarms you and other users (if registered) will receive SMS including “TEMPH=XXX C”
or “TEMPL=XXX C” texts.
Once cable connection is lost / broken, you and others users will receive SMS including “CABLE FAULT!” text.
In case of power failure, power restoration, keep alive period exceeds and low battery case; you and other users
will only receive SMS including “POWER FAIL”, “POWER OK”, “STILL ALIVE” and “LOW BATTERY” texts.
3.1. Re-configure Your Device
-
mands”.
3.2. Check GSM Signal Strength
Please follow article 3.1 and then only send your last password with SMS. You will receive “CONFIG OK <XX>,
TEMPL <LL> TEMPH <HH>” text (where XX is GSM signal strength, LL is the low alarm limit and HH is the high
3.3. Reset Your Device
solid ON. Then send an SMS to the device including “RESET” command. LED will blink a few times and become so-
Admin Number”.
3. Normal operation and alarms

Intab SMS-alarm
Power supply •
•
Inputs • Digital temperature sensor input
• Power adaptor input
Outputs • Not available
GSM module • GSM 900/1800 MHz Dual Band (A1400)
• GSM 850/900/1800/1900 MHz Quad Band (A1400-
Quad)
Event alerts
• SMS in case of Low or High Temperature
• SMS in case of Temperature Restorations
• SMS in case of Cable Fault
• SMS for Power Failure
• SMS for Power Restored
• SMS for Low Battery
• SMS for Keep Alive Messages
•
• Change security password
•
• Set low and high temperature threshold values (bet-
ween -55 0C to
• +99 0C)
• Enable & disable weekly keep alive messages
• Reset device
Operating temperature • -10°C to +50°C (non-condensing)
• -55°C to +100°C (temperature probe)
Dimensions • 109x54x30 mm
Package content • 1 x A1400 GSM Temperature Detector
•
• 1 x Digital Temperature Sensor
• 1 x User Manual
• 4 x Fixing Screws & Insertion Pies
Technical specification

www.intab.se • [email protected] • +46 302-24 600
Gjutarevägen 1 • 443 61 Stenkullen
My data:
Admin telephone number:
Password:
Telephone number SIM:
Table of contents