Bluesky BSC6000 User manual

BSC6000
Wireless Serial Device Servers
Company Website:
www.bluskyelectronics.com
Product Website:
www.convertermodem.net
QUICK
INSTALLATION
GUIDE

Console
Back View
Top View Side View
Front View
RJ45
Reset
Power
RS-232
Antenna
Panel Layout
BSC6121
2

Console
Back View
Top View Side View
Front View
RJ45
Reset
Power
RS-422/485
DIP Switch
Antenna
Panel Layout
BSC6122
3

Console
Back View
Top View Side View
Front View
RJ45
Reset
Power
RS-232/422/485
Antenna
Panel Layout
BSC6123
4

Overview
The BSC6000 series wireless device servers lets you connect RS-232 (BSC6121),
RS-422/485(BSC6122) or RS-232/422/485 (BSC6123) serial devices (such as
energy meter, card reader, PLC, CNC) to IP-based Wireless and Wired Ethernet
networks quickly and easily. You can access your serial device at any place over
network with BSC6000 series devices. Highly compatible with user’s existing
web application program, BSC6000 series devices also provides TCP Server, TCP
Client, UDP, Virtual Com and some other operation modes. Under the Virtual
Com mode, users can manage their serial port devices on the network with their
current serial port monitoring software perfectly.
NOTE:
‘i’ on the end of device model indicates an isolated model.
Packing List
1. BSC6000 series wireless device server x 1
2. 3dB gain external antenna
3. CBL-F9F9: Female DB9 to female DB9 serial cable x 1 (optional)
4. 12V power supply x 1
5. CD with software utilities and documentations in PDF format x 1
6. Quick installation guide x 1
7. DIN rail mounting kit (35mm) x 2
8. Metric screw (M3 x 6) x 4
9. CBL-P: Power Jack to TB Power supply connector x 1
Connectors’ Description
Ethernet Interface
The 10/100M Ethernet port is used to connect the device server to the network
in your application. There are two status LEDs to indicate the connection status.
Left LED (speed) Right LED (Link&Act)
Color Meaning Color Meaning
Off 10 Mbps Off No Link
Green 100 Mbps Amber Link&Activity
The Ethernet Port uses RJ45 connector
Pin Signal
1 TX+
2 TX-
3 RX+
6 RX-
Contact 1
Left LED
Contact 8
Right LED
5

RS-232 Ports of BSC6121
DB9M Pin # RS-232
1 DCD (Modem Control Input)
2 RXD (Data In)
3 TXD (Data Out)
4 DTR (Modem Control Output)
5 GND
6 DSR (Modem Control Input)
7 RTS (HW Flow Control Output)
8 CTS (HW Flow Control Input)
9 NA
RS-422/485 Ports of BSC6122 (Screw Terminal Block)
BSC5122 Connection Serial Device
RS-422 or 4-wire RS-485 Mode
TX+ RX+
TX- RX-
RX+ TX+
RX- TX-
GND GND
2-wire RS-485 Mode
D+ D+
D- D-
GND GND
RS-232/422/485 Ports of BSC6123
DB9M
Pin #
RS-232
(Port 1)
RS-232
(Port 2) RS-422 RS-422
1 DCD – T– –
2 RXD RXD T+ –
3 TXD TXD R– D–
4 DTR – R+ D+
5 GND GND – –
6 DSR – – –
7 RTS RTS – –
8 CTS CTS – –
9 – – – –
1 3
7
2
6
4
8
5
9
GND
R+/D+
R–/D–
T–
T+
1 3
7
2
6
4
8
5
9
6

DIP Switch Settings (Only for BSC6122 type)
DIP Switch State Description
1 ON Port 1 terminated
2 ON Port 2 terminated
Console Port
You can access the Linux shell and Bootloader page through the Console port.
Mini USB Pin Signal
1 3.3V
2 DRXD
3 DTXD
4 –
5 GND
Power Supply
It connects the 9-36VDC power line to the BSC6000 series device. If the power is
properly supplied, the LED “Power” will show a solid red color.
Device Connection 9-36VDC
V+ +
V– –
EGround
Reset Button
Use a pointed object, such as a straightened paper clip or toothpick, to press the
reset button. Push reset button to reset the device. Push reset button about 5
seconds to reset the device into Factory Default.
Operation Indication LEDs
There are four LEDs (Power, Link, Port1, Port2) providing indications of power
is on, device is connected to wireless or wired network and port receive and
transmit activities in each port.
LED indicators Status /LED indication
Power Power is on: Red
Link Wi-Fi Link: Red
Ethernet Link: Blue
Port 1 Data transmitted: Red
Data received : Blue
Port 2 Data transmitted: Red
Data received : Blue
O
1
N
2
1 32 4 5
7

Connection of BSC6000 series device to the Network
To get started, you must connect the BSC6000 series device to your wired
network. The nal setup should look like the shown diagram:
NOTE:
If powered up correctly, the BSC6000 series device power
LED indicator lights red and remains on. And when the Link
indicator lights red, you can start to congure the device.
AC-DC ADAPTOR
Network
Switch
PC
Software
Install BLUSKY Device Manager
1. Open BLUSKY Device Manager on the CD-ROM.
If the CD does not launch automatically:
a. Click the
Start
button on the Task Bar and select
My PC,
double click the
CD drive icon.
b. Enter your CD drive disc, and Double click
BLUSKY Device Manager Setup,
start the install process.
2. Follow the installation wizard prompts.
8

Assign IP
You have several options for assigning an IP to the BSC6000 series device. We
recommend that you connect it to the network and assign the IP address using
BLUSKY Device Manager Software. For information on other methods, see the
BSC5000 and BSC6000 Series User Guide.
NOTE:
The BSC6000 series device is automatically assigned an
IP address on DHCP-enabled networks, as it is DHCP-enabled
by default. If there is no DHCP server in the network, BSC6000
series device will assign the following IP address automatically:
192.168.127.127.
1. Click
Start Programs BLUSKY Device Manager BLUSKY Device
Manager.
If your PC has more than one network adapter, a message displays.
Select an adapter and click
OK
. Then click the Search Devices icon and select
the device from the list of device servers on the local network.
2. Click the
Assign IP Address
icon .
3. If prompted, enter the hardware address (specied on the product label)
in the format 00-23-00-XX-XX-XX, where the XXs are unique numbers/letters
assigned to the product.
4. Select
Static address
and enter the IP address you want to assign.
5. Click the OK and a conrm window displays. Click OK.
9

NOTE:
You can click the Search
Devices icon and nd the device
manually on the local network. If you
cannot reach it, make sure the device
is properly attached to the network
and that the IP address assigned
is valid for the particular network
segment you are working with.
Conguration
In this Quick Installation Guide, we briey describe how to congure the
BSC6000 series device using Web-Manager, a browser-based conguration tool.
For detailed information on Web-Manager conguration and other methods,
please see the BSC5000 and BSC6000 Series User Guide.
1. Select the device and click the
Web Conguration
icon . The Web-Manager
window displays in your browser. Follow the prompts to enter the user name,
password. The default account is: user name: root password: root.
NOTE:
Alternatively, to open Web-Manager, open your favorite
web browser and enter the IP address of the unit.
2. Use the menu (buttons) on the left to navigate to sub pages where you can
congure the BSC6000 series device.
3. When you nish the new conguration, click the
Apply
button to upload the
settings into the device.
10
Table of contents