FCC Registration Number,
under Part 68 rules: CD272Q-17147-KX-N
Ringer Equivalence: 0.0B
Controls (screwdriver-adjustable): Loudspeaker Output Volume,Talkback Volume, Switching Sensitivity,
Switching Delay
Telephone to Loudspeaker
Rated Power Output: 15W
Frequency Response: 200 Hz to 10 kHz
Input Sensitivity: -20 dBm
Input Impedance: 600 ohms, balanced
Distortion (@RPO): Less than 3% (150 mV input signal)
Signal-to-Noise Ratio: -50dB (20 Hz to 20 kHz)
Voice-Activated Switching: Sensitivity -46dBm; Attack Time – Less than 5ms. (3ms., typ.);
Switching Delay Time – adjustable from 50 ms. to greater than 0.5 sec.
Output Impedance: 25V or 70V balanced line
Loudspeaker to Telephone
Frequency Response: 1500 Hz to 20 kHz
Distortion: Less than 2%
Signal-to-Noise Ratio: -40 dB
Output Level: Processed to meet FCC Part 68
Circuit Overload Protection: Push-to-Reset circuit breaker, Safe Operating Area (SOA) and thermal
protection for the output device
Unidirectional Operation: Terminals provided to defeat two-way function
Power Requirements: 120V AC, 60 Hz, 0.7A
Temperature Range: 0 - 50°C (32 - 122°F)
Humidity Range: 0 - 95%, noncondensing
Enclosure: Sheet metal finished in black enamel
Dimensions: 5-1/4" H x 19" W x 2-7/8" D
Weight: 7 lb.
50 Spring Street, Ramsey, NJ 07446, U.S.A.
Tel. 201-934-8500 FAX: 201-934-9832, www.bogen.com
The paging/talkback amplifier shall be a BogenTBA15,
approved under part 68 of FCC rules. The unit shall
provide two-way communication between a
telephone and remote loudspeakers. It shall provide
automatic electronic switching of the direction of
conversation, without the use of relays or other
moving parts.
The amplifier shall have a rated power output of 15
watts. The frequency response shall be shaped for
maximum intelligibility and background noise rejec-
tion. Distortion shall be less than 3% at rated power.
Attack time for the voice-activated circuit shall be
less than 5ms. (3ms., typ.). Switching delay time shall
be adjustable from less than 50ms. to greater than 0.5
sec. Screwdriver-adjustable controls shall be provided
to adjust switching sensitivity, switching delay, and
loudspeaker and handset volume levels.
Terminals shall be provided for connection of a 600-
ohm transformer-coupled telephone input line, and
25V/70V constant-voltage outputs. Mute terminals
shall be provided to defeat the talkback function.
Terminals shall be housed within a panel recess and
protected by a removable cover.
The amplifier shall operate from a 120V AC, 60 Hz
source. Circuit safeguards shall include a press-to-
reset AC circuit breaker, safe operating area (SOA)
and thermal protection. A power lamp shall be pro-
vided on the front panel.
The amplifier enclosure shall be constructed of sheet
metal and finished in black enamel. Overall dimen-
sions shall be 5-1/4" H x 19" W x 2-7/8" D. Keyhole
slots and machine-screw holes shall be provided for
wall- or rack-mounted installation.
Architect and
Engineer
Specifications*
Technical
Specifications
* Architect and Engineer Specifications are available on CD and