DESCRIPTION
The Bogen Model WMK1is a flush in-wall mounting cabinet
designed to accommodate Models C10/C10MOH,
C20/C20MOH, CAM, and CAM2.The cabinet fits between stan-
dard 2 x 4’s on 16" center wall studs, with the front panel act-
ing as a plaster ring. Controls are accessible via a tilt-open door
that may be locked in either the closed or open position. The
cabinet is finished in black and is made from sturdy 16-gauge
steel. It is supplied with a backbox which includes an easily
mounted AC power receptacle.
DIMENSIONS & WEIGHT
Wall Box 14"W x 13-1/2"H x 3-1/2"D
Face Plate 16"W x 14-1/2"H
Tilt-Open Door 11-5/8"W x 8-3/8"H
Minimum, Opening Required 14-1/8"W x 13-5/8"H
Shipping Weight 13 lbs.
INSTALLATION
ACCESSIBILITY: The backbox must be placed so that the
controls are at an appropriate height for operation.Typically, the
bottom of the backbox should be three feet above the floor.
MOUNTING: The flush-mounting backbox must be secured
to support surfaces inside the wall or, in new construction, must
be built into the wall.The WMK1is shipped with the front panel
and door assembly temporarily secured to the backbox. Remove
the assembly from the backbox and mount the box with four
screws through the slotted holes (see mounting diagram on the
back of this sheet). Use these slotted holes to position the box
so that it is flush with the surface of the finished wall.When this
is accomplished, add four more screws through the holes just
forward of the slotted holes. Securely tighten all eight screws to
prevent any further movement of the backbox.The AC recepta-
cle must be located at the top of the backbox.The wall cutout
for the backbox should be 14-1/8" wide and 13-5/8" high.
WIRING: The backbox has a ½" conduit entry above the
receptacle box which must be used forAC line connection. (This
is the knockout between two small screw holes.) Where possi-
ble, locate the backbox near a suitable #14 AWG, 3-wire single-
phase, 120V AC line. Use wire nuts to connect the receptacle.
The box must be convenient for connection of microphone
input cables and speaker lines.All wires enter the box inside the
wall.
CAUTION
Do not locate box or connecting wires near steam lines or other heat
sources.
INSTALLATION OF THE AMPLIFIER: The amplifier is
secured to the door of the WMK1by four screws.A separately
mounted flange on the door provides a stop for the door and,
when removed, allows the amplifier to be dropped down for
connections. Audio cables may be brought into the backbox
through any knockout other than that used for the AC line.
• Tilt-open door
• Can be locked in closed or open position
• Used with models C10/C10MOH, C20/C20MOH, 10- and
20-watt amplifiers, and CAM or CAM2 mixer amplifiers
MODEL WMK1
WALL MOUNT CABINET
© 2000 Bogen Communications, Inc.
Printed in U.S.A. All rights reserved. 54-5634-07R2 0011
Refer to the mounting diagram and proceed as follow:
1. With the wall box mounted, use wire nuts to connect AC
wiring. Install the AC receptacle in the top of the box using
two #8 x ½" sheet metal screws.
2. Bring all wiring into the wall box, including the speaker and
microphone wires, through knockouts in the backbox.
3. Before installing the front panel on the wall box, install the
lock.When doing so, make sure that the locking cam is
down when in the locked position.
4. Mount the front panel and door assembly to the wall box
with #8 x 1- ¼" sheet metal screws through the Tinnerman
clips on the box.
5. Remove the feet from the amplifier.
6. Install the amplifier mounting screws in the door, using the
feet to hold the screws in place.
7. Mount the amplifier to the front door.
8. Connect speaker and input wiring to the amplifier.
9. Plug the amplifier into the AC receptacle.
10. Check operation of amplifier.
11. Raise the door to a level which allows the door stop to be
installed with two #6 by ¼" sheet metal screws.
12. Assure that the door lock operates correctly.
50 Spring Street, Ramsey, NJ 07446
Tel: 201-934-8500 Fax: 201-934-9832
E-mail: [email protected];Web: www.bogen.com
(4 REQUIRED)
WITH AMPLIFIER
ORIGINALLY SUPPLIED
FOOT WITH SCREW
DOOR STOP MOUNTED BEHIND FRONT PANEL
WITH FELT PAD ON FRONT SURFACE
NO. 6x1/4 SCREW USED
TO MOUNT DOOR STOP
(2 REQUIRED)
NO. 8x1-1/4 SCREWS
MOUNT FRONT
PANEL TO WALL BOX
(4 REQUIRED)
TINNERMAN CLIPS
MOUNTED ON SIDES
OF WALL BOX
(4 REQUIRED)
NO. 8x1-1/4 (8) SCREWS
MOUNT WALL BOX
DOWN IN LOCKED
POSITION
LOCK
RECEPTACLE BOX
MOUNTED WITH 2
NO.8x1/2 SCREWS
A.C. RECEPTACLE
BOX
CONDUIT ENTRY ENCLOSED
BY RECEPTACLE BOX
WIRE NUT
CONNECTIONS
KNOCKOUTS
AMPLIFIER (SOLD SEPARATELY) 11
11
1
2
3
3
41
9
4
567
8

Other Bogen Enclosure manuals

Bogen S86T725PG8WBR User manual

Bogen

Bogen S86T725PG8WBR User manual

Bogen PVMC User manual

Bogen

Bogen PVMC User manual

Bogen RE84 Guide

Bogen

Bogen RE84 Guide

Popular Enclosure manuals by other brands

iseg MMS-Crate Series Technical documentation

iseg

iseg MMS-Crate Series Technical documentation

ABB UniSec DY800 Installation, service and maintenance instructions

ABB

ABB UniSec DY800 Installation, service and maintenance instructions

Stardom SOHORAID ST8-TB3 user manual

Stardom

Stardom SOHORAID ST8-TB3 user manual

EMC CLARiiON DAE2 Setup and Cabling Guide

EMC

EMC CLARiiON DAE2 Setup and Cabling Guide

Lenovo ThinkSystem DW612S Neptune DWC System configuration guide

Lenovo

Lenovo ThinkSystem DW612S Neptune DWC System configuration guide

Octagon MOBL-D2 Technical manual

Octagon

Octagon MOBL-D2 Technical manual

CRU DataPort 22 quick guide

CRU

CRU DataPort 22 quick guide

inXtron Hydra eSATA user manual

inXtron

inXtron Hydra eSATA user manual

XtendLan XL-RAID-SATA2-USB user manual

XtendLan

XtendLan XL-RAID-SATA2-USB user manual

Sharkoon Shark Zone C10 manual

Sharkoon

Sharkoon Shark Zone C10 manual

Dell PowerVault MD3000i Upgrade guide

Dell

Dell PowerVault MD3000i Upgrade guide

Hartke PRO 2200 user guide

Hartke

Hartke PRO 2200 user guide

Icy Box IB-246FP-C3 manual

Icy Box

Icy Box IB-246FP-C3 manual

Origen ae S8 user guide

Origen ae

Origen ae S8 user guide

Caselabs Merlin Pedestal Series Assembly guide

Caselabs

Caselabs Merlin Pedestal Series Assembly guide

CalDigit VR Getting started

CalDigit

CalDigit VR Getting started

Stahl 8150/2 Series operating instructions

Stahl

Stahl 8150/2 Series operating instructions

Vantec NexStar TX installation guide

Vantec

Vantec NexStar TX installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.