Bond Signature Series User manual

STONE FIRE FOUNTAIN
ITEM# Y95849
LOWE’S# 2566885
MODEL# BFF3001-1
INSTALLER: Leave this manual
with the appliance.
CONSUMER: Retain this manual
for future reference.
DANGER
WARNING
WARNING:For outdoor use only.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to the owner's information manual provided with this appliance.
For assistance or additional information consult a qualified installer, services agency or
the gas supplier.
FIRE OR EXPLOSION HAZARD
If you smell gas:
Shut off gas to the appliance.
Extinguish any open flame.
If odor continues, leave the area immediately.
After leaving the area, call your gas supplier
or fire department.
Failure to follow these instructions could
result in fire or explosion, which could cause
property damage, personal injury, or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance. An LP-cylinder not connected
for use shall not be stored in the vicinity of
this or any other appliance.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
•
•
•
•
Installation and service must be performed
by a qualified installer, service agency,
or the gas supplier.
DANGER CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or
home.
SERIES

SAFETY INFORMATION
Before you assemble or operate this unit, please carefully read this entire manual. Failure to do so
may r
Bond Manufacturing Co., Inc. | Page 2
WARNING
•
•THIS UNIT IS INTENDED FOR OUTDOOR USE ONLY! This product shall be used outdoors, in a
ventilated space and shall not be used in any enclosed area.
•This unit is to be used with propane gas only! (sold separately)
•Do not attach a remote gas supply to this unit.
•Only use propane gas for this unit.
•Solid fuels shall not be burned in this appliance.
•
•LP GAS WARNING: Do not use any more than 1/4in depth lava rocks/pumice stones/LavaGlass®
above the bur
•If the propane gas tank is leaking gas, you may hear, see, or smell a hiss. Do the following:
e department for help.
•Applying too much propane may result in gas pooling and will not burn. Allow fresh air into the unit
so that the remaining gas may escape.
•
•Manifold pressure: 11 inch w.c. (2.74kPa).
•
•You must use a propane tank that has a collar to protect the gas valve.
•
•The tank system must be set up for vapor withdrawal.
•Discontinue use if any part of the propane tank is damaged. Rust and dents may be hazardous and
should be inspected by a gas supplier.
•
•
rocks/pumice stones/LavaGlass®could pop out and cause injury. Should any rocks pop out, discard
them.
•Always ensure that lava rocks/pumice stones/LavaGlass®are completely dry before use. Failure to
do so will cause them to crack or pop.
•Do not operate unit until all parts are fully assembled.
•Do not paint or color any part of this heating unit.
•Unit may be hot while in use, do not attempt to move it while in use.
•Never leave this heating unit unattended while in use.
•This unit is not intended for cooking.
•
•Keep a safe distance to avoid burning skin or clothing.
•Do not sit or rest hands or feet on this heating unit.
•
•Keep all electrical cords and fuel supply hose away from heated surfaces.
Use LP propane tanks with the following dimensions: diameter 12 in, height 18 in - capacity 20 lbs.
The installation of this unit must adhere to local codes or Propane Storage and Handling Code,
CSA B149.2.
pit.
•Cover must be removed when burner is in operation.

1-866-771-2663 | Page 3
• Combustible material should not be within 48 inches of the top of the unit, or within 48 inches
around the entire unit.
• Keep the appliance area clear and free fr
vapors and liquids.
•
•Do not add water into the unit.
•Do not operate unit if any part has been under water. Immediately call a
technician to inspect the appliance and replace any part of the control system and any gas
control that has been under water.
•Do not disconnect any part while unit is in use.
•Do not store a spare propane tank on or near this unit.
•If the heating unit is indoors, detach the propane tank and leave outdoors.
•Always remove protective cover before operating (if applicable).
•Do not set the protective cover over the unit until it is turned off and completely cooled down.
•Check for leaks after not using the unit for long periods of time.
•Children should never operate this unit. Children must be supervised while near this unit.
•Keep gas tank at least 5 feet away from unit when lit. (if external tank)
•Maximum gas supply: 250 psi; Min. gas supply: 10 psi.
inspected annually and cleaned regularly.
•Inspect all elements of this heating unit before each use. If there is damage, the burner must be
replaced.
•Keep the hose out from any pathways to eliminate any accidental damage. (if external tank)
•Be aware of the hazards of high temperatures and stay away from the unit to avoid any burns or
injury.
of the U.S. Department of Transportation or the National Standard of Canada CAN/CSA-B339, LP gas
tanks, spheres and tubes for Transportation of Dangerous Goods; and Commission.
gas tank connection.
cks.
•Children and adults should be alerted to the hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
•Young children should be carefully supervised when they are in the area of the appliance.
near the appliance.
•Any guard or other protective device removed for servicing the appliance shall be replaced
prior to operating the appliance.
may be required as necessary. It is imperative that the control compartment, burners and
circulating airways of the appliance are kept clean.
(CGA791) LP
The appliance when installed, must be electrically grounded in accordance with local codes, or in
the absence of local codes, with the National Electrical Code, ANSI/NFPA 70; or the Canadian
Electrical Code, CSA C22.1, if applicable.
•

SAFETY INFORMATION
Only use the regulator and hose assembly provided with this unit. Replacement parts must be supplied
directly by Bond Manufacturing Co., Inc.
NOTE: You must follow all steps to properly assemble this heating item. Make sure the gas
valve is turned ‘OFF’ before assembling. Do NOT attempt to assemble without proper tools.
Bond Manufacturing Co., Inc. | Page 4
Inspect the burner before use of this unit. If the burner shows any kind of damage, do not operate
the appliance. For assistance with repair or replacement of the burner or any other parts, calls Bond
Manufacturing Co., Inc. 1.866.771.2663.
Min. Clearance
48 in (121.9 cm)
Min. Clearance
48 in (121.9 cm)
Min. Clearance
48 in (121.9 cm)
Combustible materials should not be within 48
inches of the top of the unit, or within 48 inches
around the entire unit.
IF APPLICABLE:
• Allow heating item to cool completely before placing on lid.
• DO NOT use heating item while lid is installed. Always remove the lid while heating item is in use.
• DO NOT use heating item while lid is installed. Always remove the lid while heating item is in use.
Before beginning assembly of this product be sure all parts are present. Compare parts with
package contents list and hardware contents list. If any part appears to be missing or damaged do
not begin assembly of this product and call customer service immediately.
Estimated assembly time: 15 minutes
Tools required for assembly (not included): Phillips Screwdriver

1-866-771-2663 | Page 5
WARNING
•Save these warnings and instructions for reference. Read all instructions before use.
•Failure to follow warnings and instructions may result in injury or property damage.
•California Prop. 65 Warning: This product can expose you to the chemicals including Lead
and Lead Compounds, which are know to the state of California to cause cancer and birth
defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
•Excessive weight or pressure on any of the fountain sections may cause it to fall. Keep pets,
children, or anyone from sitting, leaning, or climbing on any of the fountain components.
•While fountain is designed to operate as splash free as possible, some water splashing out of
the fountain is inevitable. Place the fountain in a location where any splashing will not cause
damage.
•The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the
branch circuit supplying fountain pump and other pond equipment. Seek your electrical supplies
dealer for this device.
•$OZD\VNHHSWKHIRXQWDLQZRUNLQJZLWKVXI¿FLHQWZDWHUDQGFOHDQRIGHEULVDQGGLUWWRHQVXUH
proper functioning of the pump.
•If necessary, clean the fountain with a soft cloth and change the water frequently. Due to water
evaporation, you may see a buildup of white residue on the fountain surface from mineral con-
tent in the water supply. To prevent such buildup, regularly clean the fountain with soap and
ZDWHU.DRQRWXVHDQ\DEUDVLYHZKLFKPD\GDPDJHWKHDSSOLHG¿QLVK
•8VHRIZDWHUFODUL¿HU RUDOJDHFLGHRIDQ\NLQGZLOOGDPDJHWKHSDLQWRQWKHIRXQWDLQDQGZLOOQRW
be covered under the manufacturer’s warranty.
•See the pump instructions for pump safety, maintenance, and warranty information.
•The pump on your fountain has no user-serviceable parts. Only an authorized service
representative should service the pump.
1. Install the fountain pump correctly before operating it.
2DO NOT allow the pump to run dry.
3. For fountains with multiple sections or attached decorations: If any of the fountain’s attached sec-
tions with electrical lights or components fall into the water located in fountain base, unplug the
fountain and turn off circuit breaker before trying to put the fountain pieces back in place.
4. If any leakage occurs around the pump housing, turn off the circuit breaker immediately and have
the pump serviced by aregistered technician.
5.Do not operate the fountain if the pump has been dropped or has adamaged power cord or plug.
6.If the plug or your wall receptacle gets wet due to water dripping down the power cord or for any
other reason, do not remove the plug from the wall outlet until the circuit breaker is turned off.
NOTE: Allow the pump power cord to hang at alower level than
the wall outlet to form a “drip loop”. This will help prevent water
from dripping down the power cord and getting into the wall outlet.
7.
Always unplug the fountain pump and any other independent electrical
GFCI DRIP LOOP
accessories (e.g. lights) from the outlet when not in use and before cleaning or replacing parts.
8. Disconnect the power cord from the outlet by holding the plug, not by pulling on the power cord.
9. Do not expose the pump to direct sunlight or to low temperatures for any period of time.
10. Keep the power cord away from high temperatures or heat sources.
11. This fountain pump is not intended for commercial use.
CAUTION
•This fountain is intended for outdoor use only.

Item Description Qty
A1
Body
1
C 1
D
Power plug (connected with water pump)
1
E
Door
F
Lava Rocks
G
H
I
1
J
CONTENTS
K
Battery (AAA)
Protective cover
1
1
1
Electronic igniter (preassembled)
Guard (preassembled)
Control knob (preassembled)
1
Fire bowl (preassembled)
Burner (preassembled)
1
1 bag
LRegulator (preassembled)
M
Water pump (preassembled)
N
Decorative ring
1
1
Waterfall ring
1
O
B
Fountain bowl (preassembled)
P
Bond Manufacturing Co., Inc. | Page 6
Drain hose 1
Q
Adjustable feet (preassembled) 4
R
1
1
F
E
B
N
O
P
I
K
L
H
M
J
G
Q
A
C
D
R

ASSEMBLY INSTRUCTIONS
1. Check that the control knob (K) for the gas
supply system is turned to the ‘OFF’position
before starting any assembly.
2. Remove door (F) from body (D), insert and
pull out the power plug (E) of the water pump
through the hole on the bottom back side of
the body (D).
3. Place propane gas tank (not included) into the
metal stand inside of the body (D).
OFF
K
D
F
E
D
1-866-771-2663 | Page 7

CYLINDER VALVE
PRESSURE
RELIEF VALVE
BLEED-OFF
VALVE
BLACK COUPLING NUT
REGULATOR
turn clockwise to connect
turn clockwise
to reseal
connections by hand only.
Make sure it is fastened securely and tighten
close the propane tank. Attach the regulator (M)
to the cylinder valve by turning the regulator
coupling nut clockwise.
Turn the cylinder valve on the tank clockwise to
4.
5. Once the tank is attached to the regulator,
make sure the propane gas tank sits on the
metal stand inside body (D) completely. Turn the
preassembled wing screw on the outer part of
metal stand clockwise to secure the propane gas
tank tightly.
6. Replace door (F) onto the body (D).
D
F
Bond Manufacturing Co., Inc. | Page 8

7. Remove the rubber cap on the electronic igniter
(L) by unscrewing and slide battery (P) into the
battery slot. Make sure the positive side of the
battery faces outwards. Screw the electronic
igniter cap (L) over the battery tightly.
L
P
9. Attach decorative ring (A) to the fixing plates
on the fountain bowl (I).
8. Remove the protective styrofoam for the water
pump (J).
A
I
CAUTION J
Protective
styrofoam
1-866-771-2663 | Page 9
Do not remove the mesh bag on the pump.

10. Pour the lava rocks (N) into the fire bowl (G).
G
N
11. Level the unit with the adjustable feet (R)
under the body (D).Pour clean water into the
reservoir on the body (D), 26~30 liters (6.9~7.9
gallons) water is suitable.
To ensure proper function, the guard (H) on this
burner (B) should be free of lava rocks (N) at all
times.
WARNING
H
Keep away from the unit and allow the unit
to burn 20 minutes for the first time use.
Always ensure that lava rocks/pumice stones/
LavaGlass®are completely dry before use. Failure
to do so will cause them to crack or pop.
CAUTION
Ensure the unit is level before using. This is
critical for the water to flow evenly around the
spill edge.
Add water frequently, make sure the water level
is between the 'MIN' and 'MAX' lines on the
decorative ring (A).
B
D
R
Bond Manufacturing Co., Inc. | Page10

To Light
To Extinguish
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the ‘OFF’
position. Brush a soap and water mixture on all connections. Turn the gas supply on. If bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
1. Turn control knob (K) clockwise to the ‘LOW’ position; let the knob pop up and continue turning
the control knob (K) to the ‘OFF’ position.
2. Close the cylinder valve on the propane gas tank if you don’t intend to use it for a long time.
OPERATION
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable). Pumice stones/lava rocks/LavaGlass®could pop up and
strike somebody’s face during the process of lighting this unit. To prevent this,stand away from the
unit for the first 20 minutes after igniting. Flame should be a yellow/blue color between 2 - 10 inches
in height.
HEATING PORTION
Wait 50 minutes after extinguishing flame prior to place a lid (if applicable) or protective cover on
heating item.
FOUNTAIN PORTION
While fountain is designed to operate as splash free as possible, some water splashing out of the
fountain is inevitable. Place the fountain in a location where any splashing will not cause damage.
$OZD\VNHHSWKHIRXQWDLQZRUNLQJZLWKVXI¿FLHQWZDWHUDQGFOHDQRIGHEULVDQGGLUWWRHQVXUHSURSHU
functioning of the pump.
ALWAYS MAKE SURE THE PUMP IS FULLY SUBMERGED UNDER THE WATERLINE PRIOR TO
TURNING PUMP ON.
1. Make sure the control knob (K) is in the ‘OFF’ position.
2. Remove door (F) and slowly open the valve on the propane gas tank by turning the knob
counterclockwise.
3. Replace the door (F) on the body (D).
4. Push and hold in the electronic igniter (L) to create sparks within the electrode, continue to hold.
5. Push in the control knob (K) and turn to the ‘LOW’ position. Keep holding down the control knob
(K) to allow gas to flow for 15 seconds.
6. If ignition doesn’t occur within a few seconds, release the control knob (K) and rotate to the ‘OFF’
position. Wait for 5 minutes for gas to clear and then repeat the above lighting instructions.
7. Once the fire product is lit, the flame intensity may be controlled by turning the control knob (K)
between the ‘LOW’ and ‘HIGH’ positions.
1-866-771-2663 | Page 11

TURN ON
Plug in the power plug to turn on the power; this will start the fountain’s water pump.
TURN OFF
Unplug the power plug or turn off the power, the pump will turn off and stop work.
NOTE:
1. Drain the water if you don’t plan to use the fountain for a long time to prevent mosquito
breeding and water odor.
2. Be sure to drain all water during winter months or cold seasons to prevent reservoir from
cracking or breaking.
3. See the instructions below for draining the water in reservoir.
Risk of electric shock. Install only to a
covered class A GFCI receptacle that has
an enclosure that is weatherproof with the
attachment plug cap inserted or removed.
Risk of electric shock. Mount the unit at a
height greater than 0.3 m from the ground
surface.
WARNING
WARNING: Please check and
ensure the power cord is not dam-
aged before using this appliance.
1. Unplug the power plug, remove the
decorative ring (A) .
2. Submerge the drain hose (Q) completely in
the reservoir, fullyfill the hose with water and
seal the two endswith two thumbs or fingers.
Then put one end of the hose into the reservoir
and the other end outside the body, make sure
the outside end is lower than bottom of the
reservoir. Remove the two sealing thumbsor
fingers at the same time, the water will flow out
through the drain hose.
A
Q
1. Unplug the power plug, remove the
decorative ring (A) .
Bond Manufacturing Co., Inc. | Page 12

MAINTENANCE
•Before performing any maintenance always disconnect propane gas tank.
•Keep the heating item free and clear from combustible materials.
•Visually inspect burner for obstructions and keep tank enclosure free and clear from debris.
•Use a soft brush to get rid of the mild stains, loose dirt and soil after the burner and pumice stones/
lava rocks/LavaGlass®are completely cooled down. Wipe down with a soft cloth.
•Harsh weather conditions may cause stubborn stains, discoloration and possibly rust pitting.
•Permanent damage may occur if powder or solvent comes in contact with painted or plastic
components on this heating unit.
•Keep the heating unit stored away from direct sunlight.
•If storing this unit inside, disconnect the propane gas tank from the gas valve.
•Not using manufacturer approved or supplied parts/accessories may result in a defective condition
and void the warranty of this heating unit.
•Always place lid (if applicable) or protective cover on heating item when not in use.
Store your product indoors during winter months. Avoiding extreme cold temperatures will
prevent from exposure damage.
•
• If necessary, clean the fountain with a soft cloth and change the water frequently. Due to water
evaporation, you may see a buildup of white residue on the fountain surface from mineral content in
the water supply. To prevent such buildup, regularly clean the fountain with soap and water. Do not
XVHDQ\DEUDVLYHZKLFKPD\GDPDJHWKHDSSOLHG¿QLVK
•8VHRIZDWHUFODUL¿HURUDOJDHFLGHRIDQ\NLQGZLOOGDPDJHWKHSDLQWRQWKHIRXQWDLQDQGZLOOQRWEH
covered under the manufacturer’s warranty.
•Check regularly that the water reservoir has sufficient water to cover the pump at all times. It will be
necessary to check more frequently in warm or windy weather.
• Disconnect the power and empty the reservoir if the fountain will not be used for an extended time.
•If installed outdoors and in afreeze-prone area of the country, ensure all water is removed and
the unit is completely dry before temperatures drop too low. This product is NOT to be operated
below 41°F or freeze damage may occur.
Remove and clean the mesh bag on the pump
frequently, at least once a week if necessary.
1-866-771-2663 | Page 13
CAUTION

TROUBLESHOOTING
Problem Cause Solution
Igniter pin and burner are wet Dry off with a soft cloth
Igniter battery is incorrectly inserted Check which direction the battery is
inserted
Igniter pin is broken Contact Bond Manufacturing Co., Inc. for
a replacement part
Electrode wire is loose or disconnected Reconnect wire to the igniter box located
inside the unit behind the igniter box
Electrode wire is shorting between valve
and igniter pin
Contact Bond Manufacturing Co., Inc. for
a replacement part
No gas flow Check that the gas tank isn’t empty
Regulator isn’t connected securely to the
tank
Tighten regulator connection to the gas
tank
Gas flow is obstructed Check all hoses for kinks and bends
Burner ports are clogged Turn all gas flow connections off. Insert
an opened paperclip (or similar item) into
each of the burner ports to clear them
out.
Flame is obstructed at burner ports Check that all burner ports are free of any
small lava rocks/pumice stones/Lava-
Glass®pieces
Regulator hose is kinked Straighten hose of all bends or kinks
No gas flow Check that the gas tank isn’t empty
Excess flow safety valve has been
activated
Turn the control knob to the ‘OFF’
position. Close the tank valve and
disconnect propane gas tank. Turn the
control knob to ‘HIGH’; wait 1 minute.
Turn the control knob back to the ‘OFF’
position. Reconnect propane gas tank.
Light the fire unit as indicated in the ‘To
Light’ section of this manual.
High or gusting winds Increase flame to ‘HIGH’
No gas flow Check that the gas tank isn’t empty
Excess flow safety valve has been
activated
See ‘sudden drop in gas flow’ above
Heating unit won’t light
Burner won’t light
while using a match
Heating unit emits a lot
of black smoke
Sudden drop in gas
flow
Flame blows out easily
--- --- TTTUUURRRNNN OOOFFFFFF TTTHHHEEE PPPOOOWWWEEERRR BBBEEEFFFOOORRREEE YYYOOOUUU CCCHHHEEECCCKKK TTTHHHEEE FFFOOOLLLLLLOOOWWWIIINNNGGG --- ---
Problem Solution
If pump does not run
Check the circuit breaker or try another outlet.
Check the water level in the fountain. Running the pump without
VXI¿FLHQWZDWHUFDQGDPDJHWKHSXPS
Check the pump discharge and intake for dirt and debris.
If hose is blocked
The pump might be “air locked.” Plug and unplug the pump several
times to release the air inside the pump.
Check and reconnect the cord and try again.
Bond Manufacturing Co., Inc. | Page 14

SUBMERSIBLE PUMP
INTRODUCTION
The pumps are carefully inspected and tested to ensure both safety and operating performance;
however, failure to follow the instructions and warnings in this manual may result in pump damage
and/or serious injury. Be sure to read and save this manual for future reference.
PUMP INSTRUCTIONS
WWWA
AARRRNNNIIINNNGGG
zEnsure that the electrical cord loops below the electrical outlet to form a ‘Drip Loop’. This will
prevent water from running down the cord into the electrical outlet.
zRisk of electric shock- This pump is supplied with grounding conductor and grounding-type
attachment plug. To reduce the risk of electric shock, be certain that it is connected only
to properly grounding-type receptacle.
zDo not remove the grounding pin from the plug.
zDo not connect to any voltage other than that shown on the pump.
zDo not pump flammable liquids.
zThe National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the
branch circuit supplying fountain pumps and other pond equipment. See your electrical sup-
plies dealer for this device.
zDo not use with water above 50℃(122°F).
Model# Description Volt. Power
BEO-5000A
water
pump120V
FrequencyFlow Height Flow Volume
60Hz 3m3500 L/ hour
NOTE: The pump data in this manual is from
lab tests. The actual pump may be different
due to the method of production or technical
improvements. This data can be used as a
reference when purchasing asimilar pump.
Filter Gland Rotor
Outlet
Pump housing Cover
Suction cap
85W
1-866-771-2663 | Page 15

C
CCAAAUUUTTTIIIOOONNN
zAlways disconnect from electrical outlet before handling the pump.
z
zDo not lift the pump by the power cord.
zFor liquids having a temperature not exceeding 50
zOperate in freshwater only.
zOperate pump completely submerged for proper cooling.
zNot for swimming pool.
zThis pump has been evaluated for use with water only.
PPPEEERRRFFFOOORRRMMMAAANNNCCCEEE
A clogged or dirty intake screen will greatly reduce performance.
Do not let the pump run when not submerged in water. Doing so may damage the pump. Always
submerge the pump in the water before plugging in the electrical outlet. It is common for air to be
in the pump and tube when first plugged in. Continue to unplug the electrical cord and then plug
it back in until water begins to flow.
MMMAAAIIINNNTTTEEENNNAAANNNCCCEEE
NOTE: Always disconnect from electrical outlet before handling the pump.
To clean the pump, remove the back cover and the impeller.
Use a small brush or stream of water to remove any debris
IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:
zCheck the circuit breaker and try another outlet to ensure the pump is getting electrical
power.
zCheck the pump discharge and tubing for kinks and obstructions. Algae build up can be
flushed out with a garden hose.
zCheck the inlet to ensure it is not clogged with debris.
zRemove the pump inlet to access the impeller area. Turn the rotor to ensure it is not
broken or jammed.
zMonthly maintenance will add to your pump’s life.
Don't operate without water.
NOTE: Ensure that the electrical cord loops below the electrical outlet to form a ‘Drip Loop’.
This will prevent water from running down the cord into the electrical outlet.
℃(122°F).
Bond Manufacturing Co., Inc. | Page 16

WARRANTY
If you have any questions or concerns, please contact Bond Manufacturing Co., Inc. at the below
resources:
CONTACT
This product has a one-year warranty against manufacturing defects in workmanship or materials.
The manufacturer warranty will be voided by, and manufacturer disclaims any responsibility for, the
following actions:
•Modication of the unit and/or components including the gas valve assembly.
•Use of any component part not manufactured or approved by Bond Manufacturing Co., Inc.
•Use and installation other than what is listed in this manual.
Please contact the manufacturer for replacement parts.
elp available in English and Spanish Monday - Friday,|
Toll Free Phone 111---866-771-BOND(2663)
8:00am - 4:30pm PST
Email customer[email protected]
Online www.bondmfg.com
H
1-866-771-2663 | Page 17

Bond Manufacturing Co., Inc. | Page 18

FUENTE DE FUEGO DE PIEDRA
NODE ARTÍCULO Y95849
NO LOWE’S 2566885
NO DE MODELOBFF3001-1
SERIES
Manual del Usuario
PELIGRO
PELIGRO DE MONÓXIDO DE CARBONO
Este electrodoméstico puede producir
monóxido de carbono, el cual no produce
olor. Su uso en espacios cerrados puede ser
fatal. Nunca use este electrodoméstico en un
espacio cerrado, como dentro de remolques,
carpas, automóviles o casas.
INSTALADOR: Deje este manual
con el aparato.
CONSUMIDOR: Conserve este
manual para futura referencia.
Una instalación, ajuste, alteración, servicio o mantenimiento indebido puede causar daño
corporal o de propiedad. Lea atentamente el manual del usuario antes de instalar o hacerle
cualquier tipo de mantenimiento a este equipo. Si no se sigue la información de este manual
exactamente al pie de la letra, un incendio o una explosión puede resultar causando daño de
propiedad, daño corporal o muerte.
PELIGRO
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
RIESGO DE FUEGO O EXPLOSIÓN
Si huele gas:
•
Apague el gas al aparato.
•
Apague cualquier flama abierta.
•
Si el olor continúa, deje el área de inmediato.
•
Después de salir del área, llame a su proveedor
de gas o departamento de bomberos.
La falla en seguir estas instrucciones podría
resultar en incendio o explosión, lo que podría
causar daño a la.
No almacene, ni use gasolina ni otros vapores o
líquidos inflamables cerca de este ni de ningún
otro electrodoméstico. No deben almacenarse
cilindros de gas propano líquido que no estén
conectados para utilizarse cerca de este ni de
ningún otro electrodoméstico.
: Solo para uso en exteriores.
ADVERTENCIA
Si no se sigue con exactitud la información de
este manual, puede resultar en un incendio o
explosión que cause daño a la propiedad, le-
siones personales, o pérdida de la vida.
La instalación y servicio deben ser realizados
por un instalador calificado, una agencia de
servicio, o el proveedor de gas.

•
•¡ESTE APARATO ESTÁ DISEÑADO ÚNICAMENTE PARA EL USO EN EXTERIORES! Este producto
debe utilizarse al aire libre, en un espacio ventilado, y no debe utilizarse en cualquier área cerrada.
•¡Se debe utilizar este aparato únicamente con el gas propano! (en venta por separado)
•No conecte un suministro de gas remoto a este aparato.
•Utilice únicamente el gas propano con este aparato.
•Los combustibles sólidos no deben quemarse en esta unidad.
•Durante el encendido de este aparato, aléjese del quemador, porque la llama se encenderá y puede
provocar lesiones.
•ADVERTENCIA DEL GAS LP: No supere una profundidad de 6.3 mm (1/4 pulg.) de rocas de lava/
piedras pómez/Lava Glass®
•Si una fuga en el tanque de gas propano está presente, es posible que escuche, vea o huela
un silbido. Haga lo siguiente: 1. Desconecte el tanque de gas propano. 2. No intente solucionar el
problema usted mismo. 3. Póngase en contacto con su proveedor de gas o el departamento de
bomberos para obtener ayuda.
•Aplicar demasiado propano puede provocar una accumulación de gas, lo cual no quemará. Permita
la entrada de aire fresco en el aparato para que el gas restante pueda ecaparse.
•Presión d’admisón: 11 pulg. CE. (2.74 kPa)
•Utilice tanques de propano LP con las dimensiones siguientes: diámetro de 30.5 cm (12 pulg.),
altura de 45.7 cm (18 pulg.) - capacidad de 20 libras.
•Hay que utilizar un tanque de propano con un cuello para proteger la válvula del tanque.
•NO llene el tanque a un nivel más de 80%.
•El sistema de suministro del tanque debe estar diseñado para la extracción de vapor.
•Descontinúe el uso si una parte del tanque de propano está dañada. La corrosión y las abolladuras
pueden ser peligrosas y se deben revisar por un proveedor de gas.
•No queme otra cosa que los materiales proporcionados para esta mesa con chimenea.
•Aléjese del aparato durante los 20 primeros minutos después del encendido por primera vez, porque
las rocas de lava/ piedras pómez/Lava Glass®podrían saltar y provocar lesiones. Si algunas piedras
saltan afuera, deséchelos.
•Siempre asegúrese de que las r
ocas de lava/ piedras pómez/Lava Glass
®estén completamente
secas antes del uso. El no hacerlo puede rajarlas o hacer que salten.
•No utilice el aparato hasta que todas las piezas estén completamente montadas.
•No pinte ni coloree ninguna parte de este aparato de calefacción.
•El aparato puede estar caliente al usarlo; no intente moverlo mientras esté en uso.
•Nunca deje este aparato de calefacción sin vigilancia durante el uso.
•Este aparato no está diseñado para cocinar.
ADVERTENCIA
Antes de montar o de utilizar este aparato, lea todo este manual detenidamente. El no hacerlo puede
causar un incendio, una explosión, una herida o la muerte.
INFORMACIÓN DE SEGURIDAD
La instalación de este aparato debe cumplir con los códigos locales o con el Código de
almacenamiento y manejo de propano, CSA B149.2.
•Manténgase a una distancia segura para evitar la quema de la piel o de la ropa.
•No se siente ni descanse las manos o los pies en este aparato de calefacción.
•Nunca ponga las manos o los dedos en la parte superior de este aparato durante el uso.
Bond Manufacturing Co., Inc. |
222Página
Other manuals for Signature Series
1
This manual suits for next models
3
Table of contents
Languages:
Other Bond Outdoor Fountain manuals
Popular Outdoor Fountain manuals by other brands

Beckett
Beckett Pond Cherub CPK302 Specifications

Bradley
Bradley WF2605 installation instructions

Sunnydaze Decor
Sunnydaze Decor SSS-741 manual

Kelkay
Kelkay 45065L instructions

Campania International
Campania International FT-103 Assembly instructions

Campania International
Campania International Andra FT-216 Assembly instructions