Installer Menu
Install the Module
1. Use the provided anchors and screws to mount the codepad base on the wall.
2. Pull the necessary wiring through the mounting plate
Wire to the control panel
Wire the codepad to the control panel using the control panel terminals labeled R, Y, G, B (PWR, A, B,
COM). Connect them to the codepad terminals labeled R,Y, G,B. Connect codepads to the SDI2 data
bus by parallel wire run from the control panel to each codepad, wire from codepad to codepad, or a
combination of the two. Use a maximum of 7500 ft (2286m) of 22 AWG (0.8mm) wire for all devices
connected to the SDI2 bus combined.
Callout- Description
1 - Control panel
2 - Terminal wiring
3 - Codepad’s wiring terminal block
Use the menu tree to program the control panel for the IUI-SOL-TEXT codepad. To program the control
panel from the IUI-SOL-ICON, use the programming address indicated in brackets ( ) next to each com-
mand as shown in the Menu Tree.
Example:
To program Exit Time using the IUI-SOL-TEXT
Method 1: By Text Menu
1. Enter by Installer Code, followed by (-) or (#] key (for examples, [1234#])
2. The press key (3), (1), (3) to enter (exit time) and program the exit time.
Method 2: By addressing programming
1. Enter by Installer Code, followed by [-] or [#] key (for examples, [1234#])
2. Press (8) (1) to enter address programming.
To program Exit Time using the IUI-SOL-ICON
Enter the installer Code followed by [#] key, then press [470#] to enter Exit Time address to program.