- 8 -
bowens.co.uk
- 7 -
bowens.co.uk
DISPLAY INDICATORS
DISPLAY INDICATORS WHEN 2 UNITS ARE PLUGGED IN.
Red LEDs will flash quickly from one side to the
other while both units are charging. Both LEDs will
flicker when the units are charged and ready to fire.
Indicators when units are charging. Red LEDs
flash from side to side while charging.
Indicators when units have charged. Red LEDs
flicker once charged and ready to fire.
OVERHEAT INDICATION.
An over heat charged will be displayed by both
LEDs flashing slowly from one side to the other.
BATTERY CARE
• You should not allow your Travelpak battery to
fully discharge as this will significantly reduce
future operating times, and the life of the
battery.
• To preserve battery life the Travelpak will
automatically disable the fast charge mode at
the low end of the batterys charge.
• It is not recommended to continue using the
Travelpak when 25% charge is showing; it is
recommended to either change the battery for
a fully charged one or stop shooting and
recharge the battery.
• To prolong the life of the Batterypak it is
recommended to recharge the battery as soon
as possible after using it. If the battery is to
remain stored for any length of time without
use, it is recommended to recharge every 3-4
weeks.
The Travelpak also features a built-in thermal cut-
out, the cut-out will only engage in extreme use.
Your Travelpak will safely complete 100 flashes at a
moderate rate without overheating.
The following table should be used as a guide only:
SPARE DUMMY PLUG STORAGE COMPARTMENT
The Travelpak control panel features a unique
storage compartment which is designed to house
two dummy plugs. Spare dummy plugs can be
stored in the compartment located on the bottom of
the control panel when they are not required during
use, or when the
Travelpak has been
stored after use.
Alternatively, they may
be tethered to the
shoulder strap /
dummy plug holders
with the loop strap
provided.
GENERAL QUESTIONS
Q. My Modelling lamp does not work when
powered by my Travelpak?
A. The Travelpak is not intended to run the
modelling lamp. This is to preserve the battery
life.
Q. Can I leave the mains connected to my
Gemini flash head while operating the
Travelpak?
A. No, DO NOT plug a mains lead in at the same
time as a Travelpak.
Q. My old Esprit does not have a 15-pin battery
connector, can I have one?
A. The Gemini range includes new circuitry so it is
not possible to upgrade older units.
Q. Can I change the rechargeable battery inside
the Travelpak myself?
A. No. Due to the high voltage/energy used this
should only be carried out by a Bowens
authorised service centre.
Q. My unit will only do about 50 shots before
cutting out; what is wrong?
A. Your Travelpak has a thermal cut-out built-in to
protect from extreme temperatures.
GENERAL QUESTIONS
Q. I have two Gemini units connected to a
single Travelpak; can I shorten their recycle
times?
A. You can lower their power setting or connect a
separate Travelpak battery to the second Gemini
flash head. Fast charge will not be available at
the low end of battery charge; therefore longer
recycle times.
Q. How can I maximise the number of flashes
obtained?
A. Turn down the flash power; make the time
between flashes longer; use an additional
(separate) Travelpak to power the second
Gemini flash head; also use the ‘slow’ charge
option.
Q. I hear a whistling noise when the unit is
charging. Is my Travelpak developing a fault?
A. No, the harder the Travelpak has to work the
more obvious this will become. This will be more
apparent when the unit is set to fast charge and
the battery has a low power charge remaining.
Q. My unit will only do about 50 shots before
cutting out; what is wrong?
A. Your Travelpak has a thermal cut-out built-in to
protect from extreme temperatures.
GENERAL QUESTIONS
Q. I have an Esprit Gemini and a Travelite III, can
I use them at the same time on one battery?
A. Yes. Even though they require different mains
voltage both can be used at the same time.
Q. I’m not going to use my Travelpak for some
time; is there anything I can do to to ensure
that storing it for long periods will not
damage the battery?
A. You should charge the battery before storage,
and then re-charge every 3 months.
Q. Can I leave the battery charger connected to
a Travelpak while using it?
A. Yes. Although if you have access to mains
power your flash heads should be used directly
with the mains as this will greatly improve the
recycle times. When using the Travelpak while
charging it the charger may not ever indicate a
full charge.
Q. Can I charge my Travelpak in a foreign
country?
A. Yes, the supplied charger has many standard
plug attachments included and will automatically
adjust to the voltage being supplied. Voltage
range from 100V - 240V, 50 or 60Hz.