B+B SmartWorx Wzzard BB-WSD2C31010 User manual

Recommended Accessories
# BB-ZXTMT
Cable Gland/Conduit Kit
# BB-WCD-TM2M
Thermistor Cable
# BB-WSCAM12-6
M12 Cable Wiring Harness Cable
Document Number: 2009WSD200_r2_BB-WSD2x_WzzardInd_4718qsg
1 (888) 948-2248 | Europe: +353 91 792444
www.advantech-bb.com
707 Dayton Road | PO Box 1040 | Ottawa, IL 61350
Phone: (815) 433-5100 | Fax: (815) 433-5109
www.advantech-bb.com | E-mail: support@advantech-bb.com
Before you begin, be
sure you have the following:
Fast and easy on the web:
www.advantech-bb.com
+ Wzzard Intelligent Edge Node
+ Wire Harness
+ (2) Lithium Thionyl Chloride AA Batteries
+ External Antenna
+ Anti-skid Disk
QUICK START
GUIDE
As nodes join the network, they will be added to the device
tree under the gateway MAC address.
When all nodes’ MAC addresses show in the tree, click the
checkbox next to each node.
Click the “Claim Nodes” button to prevent the nodes from
joining another open network.
Congure the Node
Mount the Node
5
6
Refer to the IWzzard Mesh Wireless Sensor user manual for
detailed conguration instructions.
Flange Mounting - Wzzard nodes may be mounted via
their mounting ears. (M5, #10)
Magnetic Mounting* - Wzzard nodes contain a powerful,
internal mounting magnet in the base of the node – pull
force 2.13 kg (4.7 lb) – convenient for temporary position-
ing and conguration of nodes.
Apply the anti-skid disk to the bottom of unit for extra grip.
* Note: UL Class1/Division2 rating does not apply (voided) when using magnetic mounting.
Putting the Node in Deep Sleep
7
When not using the node for some time, the node should be
put into deep sleep.
Press the Status/Sleep/Reset conguration button for 5
seconds until the Status LED turns off.
The node will retain all settings, including the associated
network if the node has been claimed. It will not reset the
device back to factory settings.
Restoring Node to Factory Default
8
To reset the node to factory defaults, press and hold the
Status/Sleep/Reset conguration button for 10 seconds until
the Status LED ashes quickly. This will:
1) Clear the sensor type information.
2) Clear the associated network information if the node has
been claimed.
3) Allow the node to search for a new network.
Models BB-WSD2C31010, BB-WSD2M31010,
BB-WSD2C21150, BB-WSD2C06010,
BB-WSD2M06010
for Industrial Applications
Intelligent Edge Node with SmartMesh IP
Wzzard™Mesh Wireless Sensor
Review Network & Claim Nodes
4
Follow the SmartSwarm quck start guide to claim and
congure the gateway. With the gateway connected to
the internet, click on the “Wzzard Mesh” button.

(continued)
IP67
Enclosure
Product
Overview
Connect Your Sensor
Wake Up The Node
1
2
Check LEDs
3
After you wake the node, the Status LED will begin
to blink. This indicates that the node is attempting to
establish a network connection. The Status LED will come
on solid when a connection is made.
Note: The Status LED goes off after 10 seconds to conserve battery life. To
check status, use a short press of the Status/Sleep/Reset conguration button.
Status LED
Data
Slow Blink
(1 per sec.)
Attempting to establish connection
with SmartMesh IP network.
Fast Blink
(10 per sec.) Firmware update in progress.
ON (solid) Unit is connected to wireless network.
MODEL 1
Brown
2
Red
3
Pink
4
Yellow
5
Green
6
Blue
7
White
8
Gray
WSD2C31010 10-30VDC AIN1 AIN2 AIN3 DIN1 GND GND GND
WSD2C21150 10-30VDC AIN1 AIN2 DO1 DIN1 GND GND GND
WSD2C06010 10-30VDC DIN1 DIN2 DIN3 DIN4 DIN5 DIN6 GND
MODEL 1
White
2
Brown
3
Green
4
Yellow
5
Gray
6
Pink
7
Blue
8
Red
WSD2M31010 10-30VDC AIN1 AIN2 AIN3 DIN1 GND GND GND
WSD2M06010 10-30VDC DIN1 DIN2 DIN3 DIN4 DIN5 DIN6 GND
Wiring for Conduit Connector Nodes
– with Attached Wiring Harness
Wiring for M12 Connector Nodes*
– with M12 Accessory Cable (from B+B SmartWorx)
Wiring Chart Abbreviations:
10-30V = 10-30V DC Power Input
AINx = Analog Input #x
DINx = Digital Input #x
GND = Ground Input
Wiring Chart Abbreviations:
10-30V = 10-30V DC Power Input
AINx = Analog Input #x
DINx = Digital Input #x
DOx = Digital Output #x
GND = Ground Input
* Note: UL Class1/Division2 rating is voided when using M12 model outdoors.
Status
LED
Antenna
Conduit or M12
Conguration
Button
Mounting Flanges
Case
Screws
Internal Magnet
(in the base)
Press and hold Status/Sleep/Reset conguration button
for 5 seconds until the Status LED comes on and begins
blinking.
Remove the four (4) black screws that hold the top of the
node in place. Connect your sensor.
Tip: It is a best practice that wiring is done prior to installing batteries or powering
up the device.
Note: UL C1/D2 rating is voided when using non UL-specied batteries.
Thread the included wire
harness through the conduit and
into the node. Plug it into the
circuit board inside the node.
Conduit Models: Analog & Digital
M12 Models*: Analog & Digital
– with Accessory Cable
You can use your own M12 cable or
order B+B SmartWorx accessory
cable #BB-WSCAM12-6.
1 White
2 Brown
3 Green
4 Yellow
5 Gray
6 Pink
7 Blue
8 Red
Terminal Block Connections
– Thermocouple & Thermistor
Thread the thermocouple and thermistor wires through the
conduit and attach them to the terminal block.
1 Brown
2 Red
3 Pink
4 Yellow
5 Green
6 Blue
7 White
8 Gray
Connect your sensor to the wires running from the node’s
conduit. Consult the following chart for wiring instructions.
Consult the following chart for wiring instructions.
M12 Accessory Cable Detail
– #BB-WSCAM12-6 (from B+B SmartWorx)

UL Class 1, Division 2
Notications and Warnings
Conduit Models Only
Model Numbers BB-WSD2C31010,
BB-WSD2C21150, BB-WSD2C06010:
10
Radio Equipment Directive
(RED) Statement
9
Hereby, B+B SmartWorx, Inc. declares that the
radio equipment type “Wzzard Wireless Mesh” is
in compliance with Directive 2014/53/EU.
The complete CE Declaration of Conformity is
available at:
https://support.advantech-bb.com/
Keywords, enter [model number]
Material Type, select Reference
Click Search
SUITABLE FOR USE IN CLASS I, DIVISION
2, GROUPS A, B, C AND D HAZARDOUS
LOCATIONS, OR NONHAZARDOUS LOCATIONS
ONLY.
CONVENANT À L’EMPLOI DANS LES SITES
DANGEREUX DE CLASSE I, DIVISION 2,
GROUPES A, B, C ET D, OU DANS LES SITES
NON HASARDEUX SEULEMENT
WARNING - EXPLOSION HAZARD - DO NOT
DISCONNECT EQUIPMENT WHILE THE CIRCUIT
IS LIVE OR UNLESS THE AREA IS KNOW TO BE
FREE OF IGNITABLE CONCENTRATIONS.
ATTENTION - RISQUE D’EXPLOSION - NE PAS
DÉCONNECTER L’ÉQUIPEMENT PENDANT
QUE LE CIRCUIT EST VIVANT OU À MOINS
QUE LA ZONE NE SAIT ÊTRE EXEMPTE DE
CONCENTRATIONS IGNIFIABLES.
For M12 Model Numbers
BB-WSD2M31010, BB-WSD2M06010:
THIS EQUIPMENT IS TO BE INSTALLED IN AN
ENCLOSURE SUITABLE FOR THE ENVIRONMENT
THAT IS ONLY ACCESSIBLE WITH THE USE OF A
TOOL.
CET ÉQUIPEMENT DOIT ÊTRE INSTALLÉ DANS
UNE ENCEINTE ADAPTÉE À L’ENVIRONNEMENT
QUI N’EST ACCESSIBLE QUE POUR L’UTILISATION
D’UN OUTIL.
The unit is to be connected to a Class 2 power source
via the terminal block.
L’unité doit être connectée à une source d’alimentation
de classe 2 via le bornier.
These products must use only the following batteries:
either Model XL-060F manufactured by XENO Energy
co LTD. Or Model ER14505 manufactured by EVE.
Please be advised of the following warning statement
regarding battery replacement.
Ces produits utilisent les batteries suivantes: soit le
modèle XL-060F fabriqué par XENO Energy co LTD.
Ou Modèle ER14505 fabriqué par EVE. Veuillez
prendre connaissance de l’avertissement suivant
concernant le remplacement de la batterie.
WARNING: Risk of Fire and Burns. Do Not Recharge,
Open, Crush, Heat Above 100˚C, Or Incinerate the
batteries. Batteries are not user replaceable, only
a qualied technician should replace the batteries.
Do not mix battery types, Do not mix old and new
batteries” or similar shall be included on the device or
accompanying documentation.
ATTENTION: Risque d’incendie et de brûlures. Ne
pas recharger, ouvrir, écraser, chauffer au-dessus de
100 °C, ou incinérer les batteries. Les piles ne sont
pas remplaçables par l’utilisateur, seul un technicien
qualié doit remplacer les piles. Ne pas mélanger
les types de piles. Ne pas mélanger les anciennes et
les nouvelles piles “ou similaires sur l’appareil ou la
documentation qui l’accompagne.
Torque value of 5 to 8 lb-in for screws used to secure
the cover to main housing must be included in
accompanying documentation.
Une valeur de couple de 5 à 8 lb-in pour les vis utilisées
pour xer le couvercle au boîtier principal doit être
incluse dans la documentation d’accompagnement.
WSD2C devices are suitable for use in a Type 3
(outdoor) environment. WSD2M devices (with M12
connector) are suitable or use in a Type 1 environment
and must be used in a suitable enclosure.
Les appareils WSD2C peuvent être utilisés dans un
environnement de type 3 (extérieur). Les appareils
WSD2M (avec connecteur M12) conviennent ou sont
utilisés dans un environnement de type 1 et doivent être
utilisés dans un boîtier approprié.
Operating temperature code for these products is T5.
Le code de température de fonctionnement pour ces
produits est T5.
See User Manual for information that is provided
separately.
Voir le manuel de l’utilisateur pour des informations
fournies séparément.
UL Class1/Division2 Applications
B+B SmartWorx Product Exceptions Summary
UL C1/D2 rating is voided when using M12 model
outdoors.
UL C1/D2 rating is voided if magnetic mounting is used
for permanent installation.
UL C1/D2 rating is voided when using non UL-specied
batteries. Do not mix old and new batteries.
This manual suits for next models
4
Table of contents
Other B+B SmartWorx Accessories manuals
Popular Accessories manuals by other brands

turck
turck Li-Q25LxE Series operating instructions

IFM Electronic
IFM Electronic Efector 250 Series Brief instructions

Coolingstyle Technology
Coolingstyle Technology CS-MRC-Q420AC01 user manual

Baumer
Baumer PF55S Operation manual

Dini Argeo
Dini Argeo 3590EKR Series user manual

ORIGO
ORIGO AD-39 quick start guide