B+B XR5I V2E User manual

Ethernet Industrial Router
XR5i v2E
USER’S MANUAL
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

USED SYMBOLS
Used symbols
Danger – Information regarding user safety or potential damage to the router.
Attention – Problems that can arise in specific situations.
Information, notice – Useful tips or information of special interest.
GPL licence
Source codes under GPL licence are available free of charge by sending an email to:
Conel s.r.o., Sokolska 71, 562 04 Usti nad Orlici, Czech Republic
Manual Rev. 1 released in CZ, February 2, 2016
i
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

CONTENTS
Contents
1 Safety Instruction 2
2 Product Disposal Instructions 3
3 Router Description 4
4 Contents of Package 5
5 Router Design 6
5.1 Router versions .................................... 6
5.2 Delivery identification ................................ 7
5.3 Order codes ...................................... 7
5.4 Basic dimensions of the router box ......................... 8
5.4.1 Plastic box .................................. 8
5.4.2 Metal box ................................... 8
5.5 Mounting recommendations ............................. 9
5.6 Removing from the DIN rail ............................. 11
5.7 Description of the front panel ............................ 12
5.7.1 Status indication ............................... 12
5.7.2 Power connector PWR ............................ 13
5.7.3 Ethernet Port ETH .............................. 14
5.7.4 Reset ..................................... 15
6 First Use 16
6.1 Connecting the router before first use ....................... 16
6.2 Start .......................................... 17
6.3 Configuration ..................................... 17
6.3.1 Configuration over web browser ....................... 17
6.3.2 Configuration over Telnet .......................... 18
7 Technical Parameters 19
7.1 Basic parameters ................................... 19
7.2 Standards and regulations .............................. 19
7.3 Technical parameters of processor ......................... 20
8 Recommended Literature 21
9 Troubleshooting 22
ii
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

CONTENTS
9.1 FAQ .......................................... 22
10 Customers Support 24
iii
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

LIST OF FIGURES
List of Figures
1 Contents of package ................................. 5
2 Front panel XR5i v2E ................................ 6
3 Front panel XR5i v2E with WiFi ........................... 6
4 Front panel XR5i v2E SL ............................... 6
5 Front panel XR5i v2E SL with WiFi ......................... 6
6 Example of the router label ............................. 7
7 Basic dimensions of plastic box ........................... 8
8 Basic dimensions of metal box ........................... 8
9 Cable routing (plastic) ................................ 9
10 Cable routing (metal) ................................. 9
11 Space in front of connectors (plastic) ........................ 10
12 Space in front of connectors (metal) ........................ 10
13 Default position of DIN holder ............................ 11
14 Removing from the DIN rail ............................. 11
15 Front panel XR5i v2E ................................ 12
16 Power connector ................................... 13
17 Connection of power supply ............................. 13
18 Ethernet connector .................................. 14
19 Connection of ethernet cable ............................ 14
20 Router reset ...................................... 15
21 Router connection .................................. 16
22 Entering the IP address of the router ........................ 17
23 Entering login information .............................. 17
24 Router web interface ................................. 18
iv
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

LIST OF TABLES
List of Tables
1 Router versions .................................... 6
2 Delivery identification ................................ 7
3 Front panel description ................................ 12
4 Status indication ................................... 12
5 Connection of power connector ........................... 13
6 Connection of Ethernet connector .......................... 14
7 Description of reset and restart router ....................... 15
8 Basic parameters ................................... 19
9 Standards and regulations .............................. 19
10 Technical parameters of processor ......................... 20
1
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

1. SAFETY INSTRUCTION
1. Safety Instruction
Please, observe the following instructions:
•The router must be used in compliance with all applicable international and national laws
and in compliance with any special restrictions regulating the utilization of the router in
prescribed applications and environments.
•To prevent possible injury to health and damage to appliances and to ensure that all the
relevant provisions have been complied with, use only the original accessories. Unau-
thorised modifications or utilization of accessories that have not been approved may
result in damage to the router and in a breach of applicable regulations. Unauthorized
modifications or utilization of accessories that have not been approved may result in the
termination of the validity of the guarantee.
•The router can not be opened.
•It must not be exceeded by the maximum voltage 36 V DC power connector on the router.
•Do not expose the router to extreme ambient conditions. Protect the router against dust,
moisture and high temperature.
•The router should not be used at petrol stations of flammable and explosive materials.
We remind the users of the duty to observe the restrictions concerning the utilization of
radio devices at petrol stations, in chemical plants, or in the course of blasting works in
which explosives are used.
•When using the router in the close proximity of personal medical devices, such as cardiac
pacemakers or hearing aids, you must proceed with heightened caution.
•If it is in the proximity of TV sets, radio receivers and personal computers, the telephone
may cause interference.
•It is recommended that you should create an appropriate copy or backup of all the im-
portant settings that are stored in the memory of the device.
2
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

2. PRODUCT DISPOSAL INSTRUCTIONS
2. Product Disposal Instructions
The WEEE (Waste Electrical and Electronic Equipment: 2002/96/EC) directive has been
introduced to ensure that electrical/electronic products are recycled using the best available
recovery techniques to minimize the impact on the environment. This product contains high
quality materials and components which can be recycled. At the end of it’s life this product
MUST NOT be mixed with other commercial waste for disposal. Check the terms and condi-
tions of your supplier for disposal information.
3
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

3. ROUTER DESCRIPTION
3. Router Description
Industrial router XR5i v2E is used to a secure connection between two local area networks
(LANs) via two ETHERNET interfaces 10/100 and secured tunnel (IPSec, OpenVPN or L2TP).
This router is supplied either in a plastic or metal casing, based on the requirements of the
customer.
Configuration is performed via web interface and protected by password. The router sup-
ports creation of VPN tunnels using technologies IPsec, OpenVPN and L2TP to ensure safe
communication. Web interface provides detail statistics about the router activities.
Other diagnostic functions ensuring continuous communication include automatic function-
ality inspection, or hardware Watchdog which monitors the status of the router. With the help
of a special window (start up script window) you may insert Linux scripts for various actions.
For some applications the key option to create several different configurations for one wire-
less router, the so-called profiles (maximum of 4), and the option to switch between them (for
example via binary input status, web interface, etc.) is essential.
The industrial router XR5i v2E has implemented SNMP protocol for remote management.
It is also possible to configure the network in bulk and use any additional software – VPN
SmartCluster configurator to easily configure a VPN or a program for monitoring routers in
the network R-SeeNet. Industrial XR5i v2E router is enhanced by the ability to create custom
functions easy integration of custom software modules.
Examples of possible applications
•security system
•monitoring
•vending and dispatcher machines
4
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

4. CONTENTS OF PACKAGE
4. Contents of Package
Basic delivered set of router includes:
•router,
•power supply,
•two crossover UTP cables,
•up to one external antenna,
•clip for the DIN rail,
•paper start guide.
Figure 1: Contents of package
Temperature range for power supply is reduced to 0 ◦C to +40 ◦C!
5
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5. Router Design
5.1 Router versions
XR5i v2E router is supplied in the following versions (see table below). All versions are
available in plastic or metal box according to customer requirements.
Router versions Router Box
ETH0
ETH1
XR5i v2E Plastic 1 x 1 x
XR5i v2E with WiFi Plastic 1 x 1 x
XR5i v2E SL Metal 1 x 1 x
XR5i v2E SL with WiFi Metal 1 x 1 x
Table 1: Router versions
Figure 2: Front panel XR5i v2E
Figure 3: Front panel XR5i v2E with WiFi
Figure 4: Front panel XR5i v2E SL
Figure 5: Front panel XR5i v2E SL with WiFi
6
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5.2 Delivery identification
Trade name Type name Other
XR5i v2E XR-5i-v2E Version in the plastic box
XR5i v2E with WiFi XR-5i-v2E Version with WiFi in the plastic box
XR5i v2E SL XR-5i-v2E Version in the metal box
XR5i v2E SL with WiFi XR-5i-v2E Version with WiFi in the metal box
Table 2: Delivery identification
Figure 6: Example of the router label
5.3 Order codes
There are all order codes for this product:
•XR5i v2E set
includes 2x Ethernet, supplied in plastic box
•XR5i v2E SL set
includes 2x Ethernet, supplied in metal box
•XR5i v2E WIFI set
includes 2x Ethernet and 1x WIFI, supplied in plastic box
•XR5i v2E WIFI SL set
includes 2x Ethernet and 1x WIFI, supplied in metal box
7
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5.4 Basic dimensions of the router box
5.4.1 Plastic box
Figure 7: Basic dimensions of plastic box
5.4.2 Metal box
Figure 8: Basic dimensions of metal box
8
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5.5 Mounting recommendations
•possibility to be put on a work surface,
•DIN rail EN 60715 with included clip CPD2 (or CKD2 for metal version).
For the most of applications with a built-in router in a switch board it is possible to recognize
two kinds of environments:
•no public and industry environment of low voltage with high interference,
•public environment of low voltage without high interference.
For both of these environments it is possible to mount router to a switch board, the following
there is no need to have examination immunity or issues in connection with EMC according to
EN 60439-1 ed.2:00 + A1:04.
Compliance of EN 60439-1 ed.2:00 + A1:04 specification it is necessary to observe next
assembly of the router to the switch – board:
•For every cables we recommend to bind the bunch, we recommend for this use:
–Length of the bunch (combination of power supply and data cables) can be maxi-
mum 1.5 m. If the length of data cables exceeds 1.5 m or in the event of, the cable
leads towards the switch – board. We recommend installing over – voltage protec-
tors (surge suppressors).
–With data cables they mustn’t carry cables with reticular tension ∼230 V/50 Hz.
Figure 9: Cable routing (plastic) Figure 10: Cable routing (metal)
9
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
•Sufficient space must be left in front of individual connectors for handling of cables,
Figure 11: Space in front of connectors (plastic) Figure 12: Space in front of connectors (metal)
•For correct function of the router we recommend to use in the switch-board earth-bonding
distribution frame for grounding of power supply of router, data cables and antenna.
10
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5.6 Removing from the DIN rail
DIN holder is suitable for DIN rail according to EN 60715 standard only. Default position of
CPD2 holder (or CKD2 for metal version), which is used for mounting the router on a DIN rail,
is shown in the following figure:
Figure 13: Default position of DIN holder
For removing from the DIN rail it is necessary to lightly push upward the router so that the
top part of the CPD2 holder (or CKD2 for metal version) hitched to the DIN rail get out of this
rail and then fold out the top part of the router away from the DIN rail.
Figure 14: Removing from the DIN rail
11
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5.7 Description of the front panel
On the front panel is the following:
Caption Connector Description
PWR 2-pin Connector for the power supply.
ETH0 RJ45 Connector for connection into the local computer network.
ETH1 RJ45 Connector for connection into the local computer network.
WIFI R-SMA Connector for WIFI antenna. Available only when the
router is equipped with WIFI module.
Table 3: Front panel description
Figure 15: Front panel XR5i v2E
5.7.1 Status indication
About router status inform one LED indicator on the front panel. ETH0 and ETH1 ports
have two additional LEDs that provide information about port status.
Caption Color State Description
PWR Green Blinking
On
Fast blinking
Router is ready
Starting of the router
Updating firmware
ETH Green On
Off
Selected 100 Mbit/s
Selected 10 Mbit/s
ETH Yellow On
Blinking
Off
The network cable is connected
Data transmission
The network cable is not connected
Table 4: Status indication
12
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5.7.2 Power connector PWR
Panel socket 2-pin.
Pin number Signal mark Description
1 VCC(+) Positive pole of DC supply voltage (+9 to +36 V DC)
2 GND(-) Negative pole of DC supply voltage
Table 5: Connection of power connector
Figure 16: Power connector
Power supply for router is required between +9 V to +36 V DC supply. Protection against
reversed polarity without signaling is built into the router.
The power consumption during receiving is 1.3 W. The peak power consumption during
data sending is 2.5 W. However, values of consumption can be increased, if some expansion
port is eqquipped. For correct operation it is necessary that the power source is able to supply
a peak current of 0.5 A.
Circuit example:
Figure 17: Connection of power supply
The positive pole VCC is marked by a red socket on the power.
13
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5.7.3 Ethernet Port ETH
Panel socket RJ45.
Pin Signal mark Description Data flow direction
1 TXD+ Transmit Data – positive pole Input/Output
2 TXD- Transmit Data – negative pole Input/Output
3 RXD+ Receive Data – positive pole Input/Output
4 — —
5 — —
6 RXD- Receive Data – negative pole Input/Output
7 — —
8 — —
Table 6: Connection of Ethernet connector
Figure 18: Ethernet connector
ATTENTION! ETH port is not POE (Power Over Ethernet) compatible!
Plug Ethernet cable into the RJ45 connector labeled as ETH (see figure below).
Figure 19: Connection of ethernet cable
14
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de

5. ROUTER DESIGN
5.7.4 Reset
When PWR LED starts flashing on the front panel, it is possible to restore the default con-
figuration of the router by pressing the RST button on the front panel. After pressing this button
the default configuration is restored and then router reboots (green LED will be on).
For pressing the RST button could be used a narrow screwdriver.
Figure 20: Router reset
We recommend backing up configuration of the router (see Configuration manual for v2
routers) because reset of the router sets the configuration to the default state.
It is important to distinguish between reset and reboot the router.
Action Router behavior Invoking events
Reboot Turn off and then turn on router Disconnect and connect the power,
Press the Reboot button in the web
configuration
Reset Restore default configuration and reboot
the router
Press RST button
Table 7: Description of reset and restart router
15
23-05-16
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
www.lucom.de info@lucom.de
Table of contents
Popular Network Router manuals by other brands

Sitecom
Sitecom X4 user manual

ZyXEL Communications
ZyXEL Communications P-2602H-D1A Declaration of conformity

gefran
gefran R-ETH100 Installation and operation manual

Cisco
Cisco Linksys WRT54G3GV2-ST Frequently asked questions

Samsung
Samsung iES4028FP Specifications

ZyXEL Communications
ZyXEL Communications NBG6604 user guide