Brantz BR6 Manual

Set Up Instructions for Brantz International 2 Pro Range of Tripmeters (BR6)
Wiring (Not Applica le of you are using your meter in conjunction with a BR57 & BR45/BR47):
•Power:
•Connect up to the vehicles 12 volt power supply as directed by the label
on the BLACK POWER CABLE co ing out of the base of the trip eter or
Plug Kit (BR43). This is BROWN to the POSITIVE Ter inal and
GREEN/YELLOW to the NEGATIVE Ter inal.
•Connect straight to the vehicles battery posts via a 2 Amp fuse (Not
Provided - Available fro Brantz) on the live wire, usually the BROWN
on +12V cars, however on Positive Earth vehicles it is custo ary to fit
the fuse to the live GREEN/YELLOW wire.
•Sensor:
•The Sensor is connected to the GREY CABLE co ing out of the base of
the trip eter as directed by the separate sensor instruction sheet
showing how to wire the exact type of sensor you have chosen.
Cali ration:
•The Trip eter is calibrated to be accurate on any vehicle fitted with any type of Brantz Sensor and using any wheel size or
gearing by eans of the three push-wheel switches arked 'CALIBRATION'.
•If the Trip eter is to easure in hundredths of a Kilo etre/Mile the push-wheel switch needs first to be set to 100.
•At the start of an accurately easured Kilo etre/Mile, press the Zero button to ensure the counter reads 00.00.
•Drive the easured distance and stop accurately at the end of the distance – Note the figure that co es up on the readout.
(This is the Cali ration Figure for this particular vehicle)
•Enter this figure into the calibration push-wheel switches on the front of the trip eter. e.g. If the readout is 05.67 set the
push-wheel switches to 567. N.B. If the readout is greater than 09.99 a Pre-Scaling Interface (BR5)/Dividing Pre-Scaler (BR5-
2A) is required – please contact us on 0044 (0) 1625 669366 or E ail: sales@brantz.co.uk
•The accuracy can be confir ed by re-running the easured distance fro zero, the eter should read exactly 01.00
•If several wheel sizes and gearings are available for the vehicle; repeat the calibration procedure for each co bination and
note down the different calibration figures.
•If you are using a Dual Sensor Switch (BR49) ake a note of the calibration figures for both sensors A and B.
Operating Instructions for Brantz International 2 Pro Tripmeters (BR6)
Use/Controls:
•The trip eter is switched on by use of the switch on the base of the trip eter.
•When the switch is oved fro position '0' to the 'I' position the eters digits will light up. N.B. A battery charger is not a
suitable power source to test the trip eter.
•The RED button on re ote reset box, when pressed will Zero the INTERMEDIATE DISTANCE readout.
•The upper toggle switch on the front of the trip eter arked 'Freeze Total'/'Zero Total' has 3 positions and will nor ally be
in the iddle position.
•If the switch is pushed UP the TOTAL DISTANCE readout will be FROZEN, when the switch is returned back to the
iddle position the readout out will continue fro the Frozen value. (This facility is useful if the competitor wishes
to correct (Pre-Set) the Total Distance readout to a value that he knows should be displayed at a certain point on the
road. The readout can be unfrozen at this point on the road so that the correct value is displayed from this point on.
This facility is also useful if the Total Distance readout is too hi h; the readout can be frozen and then the vehicle
driven without the displayed value increasin ).
•If the switch is o entarily switched DOWN this will Zero the TOTAL Readout.
•The lower toggle switch on the front of the trip eter arked 'Count +'/'Count –' allows the trip eter to count upwards or
downwards.
•The STEP control kno is to edit the TOTAL DISTANCE readout value. Turning the knob clockwise a click will be felt and the
TOTAL DISTANCE readout will start to count either up or down depending on the position of the Count +/Count – toggle
switch. (This facility is useful to ali n the Total readout value to any iven value , say, by the or anisers handbook at a certain
point).
•The STEP control can be used with the FREEZE switched ON.
•The STEP control should nor ally be in the off position that is turned fully anti-clockwise until a click is felt.
•For Long Distance events the deci al place on the TOTAL Display can be shifted fro 00.00 to 000.0, by:
•With the trip eter OFF; hold down the Zero Total toggle switch and switch the trip eter ON.
•The trip eter will return to it's default 00.00 when the unit is switched Off and On again.

Official Measured Distances and Cali ration
If the rally organiser has laid out an 'official distance' or you wish to make your tripmeter read the same as the rally organisers
distances then the following instructions apply for cali ration:
•Enter 100 (C) into the push-wheel calibration digits (N.B. If the official easured distance is greater than 20 iles you would
need to enter a uch higher figure for C e.g. between 399-999).
•With the Total and Inter ediate Displays showing Zero drive the total official easured distance i.e. 4.8 (D) iles and note
down the readings i.e. 21.98 (T) (this should be identical on both Inter ediate and Total Displays)
•Now use the following for ula:
(T/D) x C
e.g.
(21.98/4.8) x 100
=>4.579 x 100
=>457.91
So enter 458 into your calibration push-wheel switches.
To confirm the figure, re-drive the measured distance and your displays should show the official distance e.g. 4.8 miles.
International 2 Pro (BR6) Extras Availa le:
ESSENTIAL EXTRAS:
•BRANTZ Sensor
•In-Line Fuse Kit (BRFUSE)
OPTIONAL EXTRAS:
•International Driver Display (BR61) – International 2-DD Pro (BR6-DD)
Upgrade Required
•Plug Kit (BR43)
•Dual Sensor Switch (BR49)
•Average Speedtable (BR19)
•Pulse Doubler (BR52) – For Cali ration figures less than 499
•Sensor Extension Cable (BR2X)
•Rally Ti er PLUS (BR32+)
•Sun Screen/Night Filter (BRSS7)
•Power Conditioner (BR21) – Essential for 6V Vehicles
Other Items in the International Range:
•International 1 Pro (BR13) – Single Display Trip eter
•International 2-DD Pro (BR6-DD) + Driver Display (BR61) – Dual Display Trip eter with Driver Display Unit
•International 3 Pro (BR8) – Triple Display showing Total Distance, Inter ediate Distance & Speed
•International 3-DD Pro (BR8-DD) + Driver Display Unit (BR81) – Triple Display Trip eter with Driver Display Unit
•International 2S Pro (BR7) – Triple Display showing Total Distance, Inter ediate Distance, Speed and Average Speed
•International 2S-DD Pro (BR7-DD) + Driver Display Unit (BR71) – Triple Display Trip eter with Driver Display Unit
Trou le-Shooting:
If you are having proble s please see our Trouble-Shooting guide (available at www.brantz.co.uk), contact your local supplier or
Contact us via E ail: [email protected] or Phone: 0044 (0) 1625 669366
V1.1
This manual suits for next models
1
Table of contents
Other Brantz Other manuals
Popular Other manuals by other brands

Cissell
Cissell AOLAUKMAN592 manual

Salter
Salter 9106 instruction manual

Eliet
Eliet Minor 4S manual

Siemens
Siemens SIMATIC RF310M operating instructions

Custom Dynamics
Custom Dynamics GEN200-KIT-1157 Installation instructions manual

ASO Safety Solutions
ASO Safety Solutions INDUS classic 74-312 operating manual