DTD-16 + G2 Installation and Operation Manual
PROGRAMMING
Output Modes
Momentary
If you have selected the momentary function for this output channel, you can pro-
gram two codes up to 5 digits for the first code and 6 digits for the second code that
can be used to activate that output. If your code is shorter than 5 digits enter a “/” at
the end of the first data string. This will cause a new line to be displayed. Enter the
second code you want to momentarily trigger. If the string is less than 6 digits press
the “Enter” key. The codes for that output will now be saved and you can go on to
programming another output. The momentary output closure duration is 1 second.
Momentary Programming Example: To program output 1 for momentary for code
123 and 321 with a time delay of 4.25 seconds before activation:
01
0
425
123/ 321(CR)
Latch
For the Latch function, the first code will be used to latch the output on, and the sec-
ond code to turn latch it off. Program the “ON” code, from 1 to 6 digits. If it is short-
er than 5 digits, terminate with the “/” character. A new line will be displayed. Now
enter the code you want to use to turn OFF that output. It must be from 1 to 6 digits
long. If it is short- er than 6 digits terminate with the “Enter” key. You cannot enter
the same code to latch an output on and turn it off.
Latch Programming Example:
To program output 2 for 456 latch on, 654 latch off with no time delay:
02
1
0.00
456/654(CR)
Exclusive Latch
For the Exclusive Latch function, the first tone/code will be used to latch the output
on, and the second tone/code to turn it OFF, if desired. You do not need to enter an
OFF code. In Exclusive latch mode, when any exclusive latch output is selected, all
other exclusive latch outputs will be reset. Enter the “ON” code, from 1 to 5 digits.
If it is shorter than 6 digits terminate with the “/” character. A new line will be dis-
played. Now enter the code you want to use to turn off that output. It must be from
1 to 6 digits long. If it is shorter than 5 digits terminate with the “Enter” key. You
cannot enter the same code to latch an output on and turn it OFF.
Exclusive Latch Programming Example:
To program output 2 for 789 x-latch on with time delay of .10 second:
02
2
010
789(CR)