manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BSi
  6. •
  7. Outdoor Light
  8. •
  9. BSi iAXIS User manual

BSi iAXIS User manual

Other BSi Outdoor Light manuals

BSi iCAVA User manual

BSi

BSi iCAVA User manual

BSi iNERRA User manual

BSi

BSi iNERRA User manual

BSi iODIN User manual

BSi

BSi iODIN User manual

BSi iTRACE User manual

BSi

BSi iTRACE User manual

BSi iFLAT User manual

BSi

BSi iFLAT User manual

Popular Outdoor Light manuals by other brands

Kichler Lighting HELEN 37536 instructions

Kichler Lighting

Kichler Lighting HELEN 37536 instructions

Thorn OXANE L installation instructions

Thorn

Thorn OXANE L installation instructions

esotec Solar Globe Light multicolor 20 operating instructions

esotec

esotec Solar Globe Light multicolor 20 operating instructions

mitzi HL200201 ELLIS Assembly and mounting instructions

mitzi

mitzi HL200201 ELLIS Assembly and mounting instructions

HEPER TILA S AFX 3 Module Installation & maintenance instructions

HEPER

HEPER TILA S AFX 3 Module Installation & maintenance instructions

Designplan TRON 180 installation instructions

Designplan

Designplan TRON 180 installation instructions

Sealey LED37 instructions

Sealey

Sealey LED37 instructions

nordlux VEJERS Mounting instruction

nordlux

nordlux VEJERS Mounting instruction

SImx ELITE LED LHTC637 installation instructions

SImx

SImx ELITE LED LHTC637 installation instructions

GEV CAROLINE 10833 manual

GEV

GEV CAROLINE 10833 manual

WE-EF PFL540 LED Installation and maintenance instructions

WE-EF

WE-EF PFL540 LED Installation and maintenance instructions

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

HEPER

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

BEGA 84 253 Installation and technical information

BEGA

BEGA 84 253 Installation and technical information

HEPER LW8034.003-US Installation & maintenance instructions

HEPER

HEPER LW8034.003-US Installation & maintenance instructions

HEPER MINIMO Installation & maintenance instructions

HEPER

HEPER MINIMO Installation & maintenance instructions

LIGMAN BAMBOO 3 installation manual

LIGMAN

LIGMAN BAMBOO 3 installation manual

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maretti

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maxim Lighting Carriage House VX 40428WGOB installation instructions

Maxim Lighting

Maxim Lighting Carriage House VX 40428WGOB installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
PRODUCT FEATURES:
Axs Recessed Celng lumnare s sutable for outdoor soffits and undercanopy nstallatons.
It s a fully gasketed archtectural lumnare for contnuous runs and perfect complement for
outdoor spaces to ensure desgn consstency.
Desgned to last n extremely harsh envronments.
RECOMMENDATIONS FOR THE USER:
1)Before the installation, make sure that there is no voltage.
2)Do not touch the fitting when it is working on / switched on
3)Do not look at the fitting directly or from a short distance.
4)Disconnect / switch off the fitting before changing the lamps
NOTES:
-Technical amendments are reserved.
-CE – Conformity mark
-The manufacturer is then discharged from liability when damage is caused by improper
use or installation.
-Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use
high pressure cleaners.
2
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
1- Axs Recessed Celng Sprng Type Mountng;
64mm
L
123
3
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
- Axs Mono Recessed Celng Electrcal Connecton
IP 68 Termnal
Block
*Page 4
IP 68 Plug
Connector
*Page 5
or or
IP 68 Socket
The ncomng
power lne.
When connectng the
lumnares, make sure that the
same color cables are
matchng. (+) Brown
( ) Yellow - Green
(-) Blue
- Axs Mono Recessed Celng Mult Electrcal Connecton
IP 68 Termnal Block IP 68 Plug Connector IP 68 Socket
RESIN
At the outlet of AC output RESIN
cable end of the final
lumnare, the component s
tghtened as a filled materal or
protected by resn.
220VAC
OUT
220VAC
IN
220VAC
OUT
220VAC
IN
220VAC
OUT
220VAC
IN
The ncomng power lne.
- Axs RGB-RGBW Recessed Celng Electrcal Connecton
Input Electrc
Input Data
220VAC
When connectng the
lumnares, make sure that the
same color cables are
matchng.
*Please contact us for cables f n dfferent colors.
When connectng the
lumnares, make sure that
the same color cables are
matchng.
*Please contact us for cables f n dfferent colors.
DATA
(+) Whte
( ) Green
(-) Brown
- Axs RGB-RGBW Recessed Celng Mult Electrcal Connecton
220VAC
DATA 220VAC
DATA
220VAC
DATA
XX 2 1
220VAC
OUT IN
DATA
OUT IN
220VAC
OUT IN
DATA
OUT IN
220VAC
OUT IN
DATA
OUT IN Input Electrc
Input Data
*Install the lumnares accordng to the order n numbers. The cable from man controller should first be connected to the lumnare number 1.
(+) Brown
( ) Yellow - Green
(-) Blue
DMX Man
Controller
and
Fuse Box
220VAC
OUT
DATA
OUT
4
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
5
5
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
6
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
Consderatons
- Do not cut-off or damage the cables of the products suppled as sockets.
Otherwse, water may enter to the lumnare through cable and damage the electronc
parts nsde.
- If you make the electrcal connecton, except for IP.68 Termnal Block - IP.68 Plug
connector - IP.68 socket; the connectons must be under IP protecton. Otherwse,
water may enter to the lumnare through cable and damage the electronc parts nsde.
- The IP68 Connectng kts must be assembled n accordance wth the nstallaton
nstructons. Otherwse, water may enter to the lumnare through cable and damage
the electronc parts nsde.
- The lumnare should not be opened and screws should not be loosened. If you want to
open the lumnare, please contact our company.
- Mountng hole should be dranaged.
Out of Warranty Stuatons
- Openng the product or loosenng the screws.
- Product last output cable s not protected IP67-IP68.
- Faulty electrcal connecton.
- Wrong IP68 socket-termnal block- plug connector connecton.
(Wrong openng of the cable length, fauly tghtenng the screws etc.)
- If the IP68 Connectng kts are under water.
- No dranage n the mountng hole.