1
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
PRODUCT FEATURES:
Axs Recessed Celng lumnare s sutable for outdoor soffits and undercanopy nstallatons.
It s a fully gasketed archtectural lumnare for contnuous runs and perfect complement for
outdoor spaces to ensure desgn consstency.
Desgned to last n extremely harsh envronments.
RECOMMENDATIONS FOR THE USER:
1)Before the installation, make sure that there is no voltage.
2)Do not touch the fitting when it is working on / switched on
3)Do not look at the fitting directly or from a short distance.
4)Disconnect / switch off the fitting before changing the lamps
NOTES:
-Technical amendments are reserved.
-CE – Conformity mark
-The manufacturer is then discharged from liability when damage is caused by improper
use or installation.
-Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use
high pressure cleaners.
2
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
1- Axs Recessed Celng Sprng Type Mountng;
64mm
L
123
3
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
- Axs Mono Recessed Celng Electrcal Connecton
IP 68 Termnal
Block
*Page 4
IP 68 Plug
Connector
*Page 5
or or
IP 68 Socket
The ncomng
power lne.
When connectng the
lumnares, make sure that the
same color cables are
matchng. (+) Brown
( ) Yellow - Green
(-) Blue
- Axs Mono Recessed Celng Mult Electrcal Connecton
IP 68 Termnal Block IP 68 Plug Connector IP 68 Socket
RESIN
At the outlet of AC output RESIN
cable end of the final
lumnare, the component s
tghtened as a filled materal or
protected by resn.
220VAC
OUT
220VAC
IN
220VAC
OUT
220VAC
IN
220VAC
OUT
220VAC
IN
The ncomng power lne.
- Axs RGB-RGBW Recessed Celng Electrcal Connecton
Input Electrc
Input Data
220VAC
When connectng the
lumnares, make sure that the
same color cables are
matchng.
*Please contact us for cables f n dfferent colors.
When connectng the
lumnares, make sure that
the same color cables are
matchng.
*Please contact us for cables f n dfferent colors.
DATA
(+) Whte
( ) Green
(-) Brown
- Axs RGB-RGBW Recessed Celng Mult Electrcal Connecton
220VAC
DATA 220VAC
DATA
220VAC
DATA
XX 2 1
220VAC
OUT IN
DATA
OUT IN
220VAC
OUT IN
DATA
OUT IN
220VAC
OUT IN
DATA
OUT IN Input Electrc
Input Data
*Install the lumnares accordng to the order n numbers. The cable from man controller should first be connected to the lumnare number 1.
(+) Brown
( ) Yellow - Green
(-) Blue
DMX Man
Controller
and
Fuse Box
220VAC
OUT
DATA
OUT
4
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
5
5
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
6
Headquarters : Konutkent Mah. 3029 Cad. No:3/91 06810 Çankaya Ankara/TURKEY Phone : +90 312 472 42 50 Fax : +90 312 502 74 75 Email : [email protected]
AXIS RECESSED CEILING INSTALLATION GUIDE
Consderatons
- Do not cut-off or damage the cables of the products suppled as sockets.
Otherwse, water may enter to the lumnare through cable and damage the electronc
parts nsde.
- If you make the electrcal connecton, except for IP.68 Termnal Block - IP.68 Plug
connector - IP.68 socket; the connectons must be under IP protecton. Otherwse,
water may enter to the lumnare through cable and damage the electronc parts nsde.
- The IP68 Connectng kts must be assembled n accordance wth the nstallaton
nstructons. Otherwse, water may enter to the lumnare through cable and damage
the electronc parts nsde.
- The lumnare should not be opened and screws should not be loosened. If you want to
open the lumnare, please contact our company.
- Mountng hole should be dranaged.
Out of Warranty Stuatons
- Openng the product or loosenng the screws.
- Product last output cable s not protected IP67-IP68.
- Faulty electrcal connecton.
- Wrong IP68 socket-termnal block- plug connector connecton.
(Wrong openng of the cable length, fauly tghtenng the screws etc.)
- If the IP68 Connectng kts are under water.
- No dranage n the mountng hole.

Other BSi Outdoor Light manuals

BSi iODIN User manual

BSi

BSi iODIN User manual

BSi iCAVA User manual

BSi

BSi iCAVA User manual

BSi iTRACE User manual

BSi

BSi iTRACE User manual

BSi iFLAT User manual

BSi

BSi iFLAT User manual

BSi iNERRA User manual

BSi

BSi iNERRA User manual

Popular Outdoor Light manuals by other brands

brennenstuhl HL DA 85 M operating instructions

brennenstuhl

brennenstuhl HL DA 85 M operating instructions

LED's light 401713 operating manual

LED's light

LED's light 401713 operating manual

Glasdon SIGNMASTER LED instructions

Glasdon

Glasdon SIGNMASTER LED instructions

Maxim Lighting 41425WGBK manual

Maxim Lighting

Maxim Lighting 41425WGBK manual

SSC-LUXon MIENTO 990070730 operating instructions

SSC-LUXon

SSC-LUXon MIENTO 990070730 operating instructions

RH SAREZZO Assembly/installation instructions

RH

RH SAREZZO Assembly/installation instructions

Energizer 10343-CO-10 Assembly and care instructions

Energizer

Energizer 10343-CO-10 Assembly and care instructions

Kenroy Home SIMPLICITY 30100ORB Use and care guide

Kenroy Home

Kenroy Home SIMPLICITY 30100ORB Use and care guide

Inspire BRONSON 1000LM Assembly, Use, Maintenance Manual

Inspire

Inspire BRONSON 1000LM Assembly, Use, Maintenance Manual

JONATHAN Y JYL9052A manual

JONATHAN Y

JONATHAN Y JYL9052A manual

GTV OS-ESOE2711-80 manual

GTV

GTV OS-ESOE2711-80 manual

Kanlux LART EL manual

Kanlux

Kanlux LART EL manual

RUSTA FINSBURY 3W manual

RUSTA

RUSTA FINSBURY 3W manual

LIGMAN NYB-80113 installation manual

LIGMAN

LIGMAN NYB-80113 installation manual

Patriot Lighting DH8090 quick start guide

Patriot Lighting

Patriot Lighting DH8090 quick start guide

SLV Elektronik TRUST 30 operating manual

SLV Elektronik

SLV Elektronik TRUST 30 operating manual

cocoweb Canberra Nautical installation instructions

cocoweb

cocoweb Canberra Nautical installation instructions

Safavieh TBL4350A instructions

Safavieh

Safavieh TBL4350A instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.