manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BubblyNet
  6. •
  7. Security Sensor
  8. •
  9. BubblyNet steinel S-HT-C12-DRWH User manual

BubblyNet steinel S-HT-C12-DRWH User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Specification
•Voltage - 24 VDC/VAC (32 mA)
•Sensing technology - Passive Infared (PIR)
•Light Level Setting - 10 - 1000 lux / 1 - 100 fc
•Environment- IP20 rated, 0°C to +40°C, 32°F to +104°F
•Installation Height - 2.5- 10 m / 8 - 32 ft
•Coverage at 9 ft
360° square mechanically scalable detection zones
presence: max. 7.9 x 7.9 m (62.41 sq.m.)
max. 25.5 x 25.5 ft (650.25 sq. ft.)
radially: max. 7.9 x 7.9 m (62.41 sq. m.)
max. 25.5 x 25.5 ft (650.25 sq. ft.)
tangentially: max. 20 x 20 m (400.0 sq. m.)
max. 65.5 x 65.5 ft (4,290.25 sq. ft.)
•Sensors - 4 Infrared Pyroelectric Detectors
•Lens Design - 13 Detection Levels, 4800 Switching Zones
•Dimensions - 4.72 x 4.72 x 2.83 in, 120 x 120 x 72 mm (LxWxD)
•
Warranty - 5 Years
High Definition IR Motion Sensor | Model: S-HT-C12-DRWH
BubblyNet - 615 Drew St., Clearwater, FL 33755 • Ph 727.316.5319 • Fx 727.683.9720 • The manufacturer reserves the right to change or modify the design, dimensions
and specications at any time without notice. The manufacturer accepts no liability for consequential damage which is occasioned to the user based on the data provided.
*results my vary based on mounting height, temperature, angle,
floor material, and line of sight.
Description
The S-HT-C12-DRWH is a low voltage, high definition, passive
infrared presence detector setting a new standard in lighting
control with minimal movement required for human presence
detection. Features four pyroelectric detectors with a high
performance lens system that creates a new global standard in
detection with 4,800 switching zones.
Features
•Passive Infrared (PIR) Sensor
•Bluetooth Mesh Qualified
•LED Motion Indicator
•Suitable for Indoor Use Only
•Program Occupancy / Vacancy
•360° Coverage Pattern
Certifications
200ft
100ft
70ft
60ft
50ft
Typical maximum distance: Outdoor (line of sight):
Indoor (through building material):
Glass:
Drywall:
Cinderblock:
Brick:
Concrete + rebar 0ft
Devices with external antenna should have the antenna outside
any metal box and away from metal surfaces as metal reduces
connectivity.
For design purposes a 60ft. maximum distance is appropriate for
most installations.
Installation
For best results, the Corridor - One Way Motion Sensor
needs to be installed within 30 feet of the closest device
within the Bluetooth Mesh network. 24VDC power
needs to be supplied to the sensor from others, the
auxiliary DC output of a BubblyNet Controller or one
BubblyNet A-T03-12-17-DS00 3w AC/DC
Transformer, neither included.
Connectivity
Devices are repeaters for other devices and should be installed
within a certain maximum distance from each other.
bubblynet.com • 727.316.5319
11.2.2023
BubblyNet - 615 Drew St., Clearwater, FL 33755 • Ph 727.316.5319 • Fx 727.683.9720 • The manufacturer reserves the right to change or modify the design, dimensions
and specications at any time without notice. The manufacturer accepts no liability for consequential damage which is occasioned to the user based on the data provided.
Settings
1 - Tangential - motion
perpendicular to the sensor
20 x 20 m (65.6 x 65.6 ft)
2 - Radial - motion either
directly toward or away from
the sensor
8 x 8 m (26.25 x 26.25 ft)
3 - Presence - minor motion
as described by NEMA
WD7 with the additional
requirement of both radial
and tangential detection
8 x 8 m (26.25 x 26.25 ft)
Mechanical Scalability
12
34
NOT USED NOT USED
Coverage
Shown at 9 ft mounting height. Coverage will vary depending on
mounting height. See pages 4 & 5 of the instruction manual for coverage
at heights from 8 to 26 ft. Maximum mounting height up to 32 ft.
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
150°
160°
170°
180°
-170°
-160°
-100°
-110°
-120°
-130°
-140°
-150°
-90°
-80°
-70°
-60°
-50°
-40°
-30°
-20° -10°
6 m (20 ft)
8 m (26 ft)
10 m (33 ft)
12 m (39 ft)
4 m (13 ft)
2 m (7 ft)
2 m (7 ft)
4 m (13 ft)
6 m (20 ft)
8 m (26 ft)
10 m (33 ft)
(39 ft)12 m
14 m (46 ft)
0 m (0 ft)
14 m (46 ft)
J-Box Mounted
IR Quattro HD
Load module
Sensor Module
120
120
41
be box, 4Mounts to a 4“ Square box,e
box or Round 3.0 Mud-Ring
DIP 1 - Normal mode / Test mode (NORM / TEST)
DIP 2 - Manual ON mode (MAN) / Automatic mode (AUTO)
DIP 3 - Momentary / Maintained switch option
DIP 4 - ‘ON’only / ‘ON’& ‘OFF’manual switching
DIP 5 - Not Used
1 - Light level setting
2 - Occupancy time delay setting
3 - Reach setting
4 - Sensor DIP switch settings
ØMin. 68 mm (2 11/16 in)
Max. 76 mm (3 in)
Mounts directly to ceiling
with quick mount spring tabs
One Gridline = 1 m / 3 ft
1
2,3
Ceiling
61 61
120
120
120
120
26
6
bubblynet.com • 727.316.5319
11.2.2023
Spring Mounted
J Box
Controller
Transformer
Load Module
Sensor Module
J Box
Controller
Load Module
Sensor Module
Line Voltage
Low Voltage