Specification
•Voltage - 24 VDC/VAC (32 mA)
•Sensing technology - Passive Infared (PIR)
•Light Level Setting - 10 - 1000 lux / 1 - 100 fc
•Environment- IP20 rated, 0°C to +40°C, 32°F to +104°F
•Installation Height - 2.5- 10 m / 8 - 32 ft
•Coverage at 9 ft
360° square mechanically scalable detection zones
presence: max. 7.9 x 7.9 m (62.41 sq.m.)
max. 25.5 x 25.5 ft (650.25 sq. ft.)
radially: max. 7.9 x 7.9 m (62.41 sq. m.)
max. 25.5 x 25.5 ft (650.25 sq. ft.)
tangentially: max. 20 x 20 m (400.0 sq. m.)
max. 65.5 x 65.5 ft (4,290.25 sq. ft.)
•Sensors - 4 Infrared Pyroelectric Detectors
•Lens Design - 13 Detection Levels, 4800 Switching Zones
•Dimensions - 4.72 x 4.72 x 2.83 in, 120 x 120 x 72 mm (LxWxD)
•
Warranty - 5 Years
High Definition IR Motion Sensor | Model: S-HT-C12-DRWH
BubblyNet - 615 Drew St., Clearwater, FL 33755 • Ph 727.316.5319 • Fx 727.683.9720 • The manufacturer reserves the right to change or modify the design, dimensions
and specications at any time without notice. The manufacturer accepts no liability for consequential damage which is occasioned to the user based on the data provided.
*results my vary based on mounting height, temperature, angle,
floor material, and line of sight.
Description
The S-HT-C12-DRWH is a low voltage, high definition, passive
infrared presence detector setting a new standard in lighting
control with minimal movement required for human presence
detection. Features four pyroelectric detectors with a high
performance lens system that creates a new global standard in
detection with 4,800 switching zones.
Features
•Passive Infrared (PIR) Sensor
•Bluetooth Mesh Qualified
•LED Motion Indicator
•Suitable for Indoor Use Only
•Program Occupancy / Vacancy
•360° Coverage Pattern
Certifications
200ft
100ft
70ft
60ft
50ft
Typical maximum distance: Outdoor (line of sight):
Indoor (through building material):
Glass:
Drywall:
Cinderblock:
Brick:
Concrete + rebar 0ft
Devices with external antenna should have the antenna outside
any metal box and away from metal surfaces as metal reduces
connectivity.
For design purposes a 60ft. maximum distance is appropriate for
most installations.
Installation
For best results, the Corridor - One Way Motion Sensor
needs to be installed within 30 feet of the closest device
within the Bluetooth Mesh network. 24VDC power
needs to be supplied to the sensor from others, the
auxiliary DC output of a BubblyNet Controller or one
BubblyNet A-T03-12-17-DS00 3w AC/DC
Transformer, neither included.
Connectivity
Devices are repeaters for other devices and should be installed
within a certain maximum distance from each other.
bubblynet.com • 727.316.5319
11.2.2023
BubblyNet - 615 Drew St., Clearwater, FL 33755 • Ph 727.316.5319 • Fx 727.683.9720 • The manufacturer reserves the right to change or modify the design, dimensions
and specications at any time without notice. The manufacturer accepts no liability for consequential damage which is occasioned to the user based on the data provided.
Settings
1 - Tangential - motion
perpendicular to the sensor
20 x 20 m (65.6 x 65.6 ft)
2 - Radial - motion either
directly toward or away from
the sensor
8 x 8 m (26.25 x 26.25 ft)
3 - Presence - minor motion
as described by NEMA
WD7 with the additional
requirement of both radial
and tangential detection
8 x 8 m (26.25 x 26.25 ft)
Mechanical Scalability
12
34
NOT USED NOT USED
Coverage
Shown at 9 ft mounting height. Coverage will vary depending on
mounting height. See pages 4 & 5 of the instruction manual for coverage
at heights from 8 to 26 ft. Maximum mounting height up to 32 ft.
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
150°
160°
170°
180°
-170°
-160°
-100°
-110°
-120°
-130°
-140°
-150°
-90°
-80°
-70°
-60°
-50°
-40°
-30°
-20° -10°
6 m (20 ft)
8 m (26 ft)
10 m (33 ft)
12 m (39 ft)
4 m (13 ft)
2 m (7 ft)
2 m (7 ft)
4 m (13 ft)
6 m (20 ft)
8 m (26 ft)
10 m (33 ft)
(39 ft)12 m
14 m (46 ft)
0 m (0 ft)
14 m (46 ft)
J-Box Mounted
IR Quattro HD
Load module
Sensor Module
120
120
41
be box, 4Mounts to a 4“ Square box,e
box or Round 3.0 Mud-Ring
DIP 1 - Normal mode / Test mode (NORM / TEST)
DIP 2 - Manual ON mode (MAN) / Automatic mode (AUTO)
DIP 3 - Momentary / Maintained switch option
DIP 4 - ‘ON’only / ‘ON’& ‘OFF’manual switching
DIP 5 - Not Used
1 - Light level setting
2 - Occupancy time delay setting
3 - Reach setting
4 - Sensor DIP switch settings
ØMin. 68 mm (2 11/16 in)
Max. 76 mm (3 in)
Mounts directly to ceiling
with quick mount spring tabs
One Gridline = 1 m / 3 ft
1
2,3
Ceiling
61 61
120
120
120
120
26
6
bubblynet.com • 727.316.5319
11.2.2023
Spring Mounted
J Box
Controller
Transformer
Load Module
Sensor Module
J Box
Controller
Load Module
Sensor Module
Line Voltage
Low Voltage

Popular Security Sensor manuals by other brands

Wiseup WBD100 user guide

Wiseup

Wiseup WBD100 user guide

RKI Instruments 35-3010RK-03 manual

RKI Instruments

RKI Instruments 35-3010RK-03 manual

Bosch Security TriTech DS835i Series installation instructions

Bosch Security

Bosch Security TriTech DS835i Series installation instructions

Honeywell RAEGuard 2 PID user guide

Honeywell

Honeywell RAEGuard 2 PID user guide

Gemtor FLW Series owner's manual

Gemtor

Gemtor FLW Series owner's manual

Macurco 6 Series Application guide

Macurco

Macurco 6 Series Application guide

ISC D2 User instruction manual

ISC

ISC D2 User instruction manual

Micro Detectors FC4 installation manual

Micro Detectors

Micro Detectors FC4 installation manual

jablotron GS-133 quick start guide

jablotron

jablotron GS-133 quick start guide

JFL Alarmes IRA-360 user manual

JFL Alarmes

JFL Alarmes IRA-360 user manual

LEGRAND Celiane 670 92 manual

LEGRAND

LEGRAND Celiane 670 92 manual

iMSENS iMSL Plafon Urano quick start guide

iMSENS

iMSENS iMSL Plafon Urano quick start guide

Rosslare SA-17 installation instructions

Rosslare

Rosslare SA-17 installation instructions

NA-DE 10100 manual

NA-DE

NA-DE 10100 manual

Ezviz CST1C manual

Ezviz

Ezviz CST1C manual

Locatechs LocaSafe VA10 Base Station Installation and operating manual

Locatechs

Locatechs LocaSafe VA10 Base Station Installation and operating manual

American Dynamics DuoTect-C AD1562 Installation and operating instructions

American Dynamics

American Dynamics DuoTect-C AD1562 Installation and operating instructions

Megger Detex 514242 Series instruction manual

Megger

Megger Detex 514242 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.