Buffalo GENTRi9K User manual

GENTRi9K
9000 SURGE WATTS / 8000 RUNNING WATTS
TRI FUEL LPG, NATURAL GAS & GASOLINE
PORTABLE GENERATOR
INSTRUCTION MANUAL
READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.
This manual provides important information on proper operation & maintenance. Every effort has been
made to ensure the accuracy of this manual. These instructions are not meant to cover every possible
condition and situation that may occur. We reserve the right to change this product at any time without
prior notice.
IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE,
DO NOT OPERATE THIS PRODUCT!
DO NOT RETURN THIS GENERATOR TO THE RETAILER!
If you experience a problem, have questions or need parts for this product, call Customer Service at
1-866-460-9436, Monday-Friday, 8 AM - 4 PM Central Time. A copy of the sales receipt is required.
FOR CONSUMER USE ONLY – NOT FOR PROFESSIONAL USE.
KEEP THIS MANUAL, SALES RECEIPT & APPLICABLE WARRANTY FOR FUTURE
REFERENCE.
SEEK THE ADVISE OF A LICENSED ELECTRICIAN FOR 120V / 240V WIRING
Visit our website for Frequently Asked Questions http://sportsmanseriesbrand.com
SF

GENTRi9K 9000 Surge Watt / 8000 Running Watt Portable Tri Fuel Liquid Propane Gas & Gasoline & Natural Gas Electric Start Generator Manual
2
Model GENTRi9K 9000 Surge Watts / 8000 Running Watts
FEATURES:
• 120/240 Volt Operation
• 15 HP Engine, 4 Stroke OHV
• Displacement (CC): 420cc
• AVR Automatic Voltage Regulation
• Low Oil Shut Off
• UL Listed Electrical Components
• Engine Shut Off Switch
• Circuit Breaker & Power Outlets
• Spark Plug Model F6TC
• 1-12V DC Outlet
• 4-120V GFCI AC Outlets
• 1-120/240V Twist Lock
• 1-120V Twist Lock RV
• 7.4 Gallons Max Capacity Gasoline Fuel Tank
• Decibel Rating < 80 db
• Mobility Kit: Included
• CARB & EPA – approved
• Run time = 10 hrs @ 50% load
• Run time = 5 Hours @ 50% Load (LP)*
on 20 lbs of LPG Fuel
• Battery Not Included
(Use a 12 Volt motorcycle battery no larger than 6" L x 3.8" H x 3.8" W (151 mm x 99 mm x 98 mm).
CCA (Cold Cranking Amps): 130 Min CCA. Comparable brands/models are: 12V 12 Ah Sealed Lead Acid
Model # XTAZ10S
• Fuel type - Liquid Propane Gas (also commonly referred to as LP, LPG and Propane) Or Unleaded Gasoline, or Natural Gas
• If you are using a generator above sea level, the generator may not function properly because of air flow getting through the mixer.
• High Altitude Use: This generator is not recommended for high altitude use above 3,000 feet.
• Propane Tank Not Included
• If you want to use a propane tank larger than 20 lbs, call Customer Service for details at 866-460-9436.
•* SURGE WATTS / RUNNING WATTS MAY BE REDUCED BY 10% WHEN USING PROPANE FUEL VS USING GASOLINE.
•* SURGE WATTS / RUNNING WATTS MAY BE REDUCED BY 20% WHEN USING NATURAL GAS VS USING GASOLINE.
2 YEAR LIMITED EMISSION-RELATED WARRANTY
THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 .The emission-related limited warranty is valid for two (2) years. Keep the
purchase receipt and mail in the product registration card for proof of purchase. Buffalo Corp limits emission-related warranty repairs to authorized service centers for
owners located within 100 miles of an authorized service center. For owners located more than 100 miles from an authorized service center, Buffalo Corp will, in its
sole discretion, either pay for shipping costs to and from an authorized service center, provide for a service technician to come to the owner to make the warranty
repair, or pay for the repair to be made at a local non-authorized service center. The provisions of this paragraph apply only for the contiguous states, excluding the
states with high-altitude areas identified in 40 CFR part 1068, Appendix III.
To exercise this warranty, DO NOT RETURN TO RETAILER. Instead, call Customer Service toll free at 1-866-460-9436 (email address info@buffalotools.com) and
you will be instructed on where to take the engine for warranty service. Take the generator and proof of purchase (your receipt) to the repair facility recommended by
the Customer Service Representative. The warranty does not extend to generators damaged or affected by fuel contamination, accidents, neglect, misuse,
unauthorized alterations, use in an application for which the product was not designed and any other modifications or abuse.
1 YEAR LIMITED WARRANTY (30 Day Limited Warranty for Commercial and Rental Purpose)
Generators are warranted to be free from defects in materials and workmanship for a period of 1 YEAR from date of original purchase. Buffalo Corp. is not liable for
any indirect, incidental or consequential damages from the sale or use of this product. Any implied warranties are limited to 1 YEAR as stated, or as otherwise stated,
in this written limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages. Some states do not allow limitation on the
length of an implied warranty. Buffalo Corp will repair or replace, at its discretion, any part that is proven to be defective in materials or workmanship under normal
use during the 1 YEAR warranty period. Warranty repairs or replacements will be made without charge for parts or labor. Parts replaced during warranty repairs will
be considered as part of the original product and will have the same warranty period as the original product. This warranty gives you specific legal rights, and you
may have other rights that vary state to state.

GENTRi9K 9000 Surge Watt / 8000 Running Watt Portable Tri Fuel Liquid Propane Gas & Gasoline & Natural Gas Electric Start Generator Manual
3
TABLE OF CONTENTS
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS.............................................................................................. 4
PACKAGE CONTENTS
PACKAGE CONTENTS .......................................................................................................................................... 9
COMPONENTS..................................................................................................................................................... 10
PREPARING THE GENERATOR FOR USE ................................................................................................................... 11
Using This Generator For The First Time.............................................................................................................. 11
Step 1 – Add Oil............................................................................................................................................ 11
Step 2 – Connect Fuel.................................................................................................................................. 11
Step 3 – Ground The Generator................................................................................................................... 13
Subsequent Use Of This Generator ...................................................................................................................... 13
Step 1 – Verify Oil Level ............................................................................................................................... 13
Step 3 – Ground The Generator................................................................................................................... 14
STARTING THE GENERATOR ....................................................................................................................................... 14
USING THE GENERATOR .............................................................................................................................................. 15
AC Usage .............................................................................................................................................................. 15
DC Usage.............................................................................................................................................................. 17
STOPPING THE GENERATOR....................................................................................................................................... 17
MAINTENANCE/CARE .................................................................................................................................................... 18
Recommended Maintenance Schedule ................................................................................................................ 18
Cleaning The Generator........................................................................................................................................ 18
Checking The Oil Level ......................................................................................................................................... 18
Changing/Adding Oil ............................................................................................................................................. 19
Changing Fuel Line ............................................................................................................................................. 19
Air Filter Maintenance ........................................................................................................................................... 20
Spark Plug Maintenance ....................................................................................................................................... 20
STORAGE/TRANSPORT PROCEDURES ...................................................................................................................... 20
TROUBLESHOOTING ..................................................................................................................................................... 21
SPECIFICATIONS ........................................................................................................................................................... 22
PARTS DIAGRAM ........................................................................................................................................................... 23
WIRE DIAGRAM .............................................................................................................................................................. 33
PORTABILITY KIT INSTALLATION................................................................................................................................. 34
POWERING GENERATOR WITH NATURAL GAS ......................................................................................................... 35
EMISSION CONTROL SYSTEM WARRANTY................................................................................................................ 36

GENTRi9K 9000 Surge Watt / 8000 Running Watt Portable Tri Fuel Liquid Propane Gas & Gasoline & Natural Gas Electric Start Generator Manual
4
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS
What You Need to Know About Safety Instructions
Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and
situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and
equipment.
Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a
potentially hazardous situation which, if not avoided, may
result in property damage.
Legal Requirements:
Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended
use of this generator. Consult a qualified electrician, electrical inspector, and/or the local agency having jurisdiction. Some areas require generators
to be registered with local utility companies. Additional regulations may apply if this generator will be used at a construction site.
SEEK THE ADVISE OF A LICENSED ELECTRICIAN FOR 120V / 240V WIRING
High Altitude Use:
This generator is not recommended for high altitude
use above 3,000 feet.

GENTRi9K 9000 Surge Watt / 8000 Running Watt Portable Tri Fuel Liquid Propane Gas & Gasoline & Natural Gas Electric Start Generator Manual
5
IMPORTANT SAFETY INSTRUCTIONS
STOP!
Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on
this generator, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.
Carbon Monoxide Gas: When in operation, the exhaust from this generator contains poisonous carbon monoxide gas. Carbon
monoxide gas is both odorless and colorless AND may be present even if you do not see or smell gas. Breathing this poison gas can
lead to headaches, dizziness, drowsiness, loss of consciousness and eventually death.
• Use this generator ONLY outdoors in non-confined areas.
• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator.
Chemicals: According to the State of California, the exhaust from this generator contains chemicals known to cause cancer, birth
defects, or other reproductive harm.
Propane (LPG): This generator may emit highly flammable and explosive vapors, which can cause severe burns or even death. A
nearby open flame can lead to an explosion even if not directly in contact the fuel.
• Do not operate this generator near open flame.
• Always operate this generator on a firm, level surface.
This fuel is highly flammable and explosive. Handling fuel can result in serious injury or burns.
• Before starting the generator, inspect your LPG tank valve for damage or leaks, attach only approved tanks that have been properly filled by
an approved station. DO NOT light or smoke cigarettes.
Replace the hose at the first sign of a leak or if age-cracking becomes apparent.
• Always handle propane fuel and generator outdoors.
• Before transporting, turn the fuel valve to the "off" position and disconnect the spark plug.
Powerful Voltage: This generator produces powerful voltage, which can result in electrocution.
• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual).
• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical
system to this generator without a qualified electrician. Doing so voids your warranty. Such connections must isolate generator power from
utility power and comply with local electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution
hazard, which may result in serious injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create
fires when utility power is restored.
• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this generator dry and operate it
with dry hands.
• Do not touch bare wires or outlets (receptacles).
• Do not allow children or non-qualified persons to operate this generator.
High Temperatures: This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees
Fahrenheit (65 Degrees Celsius).
• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces.
• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and
before storing indoors.
• Hot exhaust may ignite some materials. Keep flammable materials away from this generator.
• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure.
Usage: Avoid the use of extension cords if possible. If you choose to use them, be sure they are sized adequately to handle the flow of
electricity. An undersized cord can overheat, short out and cause a fire.
Table of contents
Other Buffalo Portable Generator manuals

Buffalo
Buffalo SPORTSMAN GEN154 User manual

Buffalo
Buffalo GEN4065 Instruction Manual

Buffalo
Buffalo GEN1850 User manual

Buffalo
Buffalo GEN1850 Installation guide

Buffalo
Buffalo Sportsman GEN10K User manual

Buffalo
Buffalo GEN7000LP User manual

Buffalo
Buffalo Sportsman GEN7000 User manual

Buffalo
Buffalo GEN7500TRI User manual