DUAL SH DBC
FRESHNESS AUDIBLE
ALERT KIT INSTRUCTIONS
INSTRUCTIONS
WARNING: Disconnect the brewer from the power source before the removal of any panel or replacement of
any component.
1. Remove the Top Cover, Front Access Panel and the Server Platform
Cover from the Brewer.
2. Remove the Keps Nut securing the Transformer Holddown Strap, Fig 1.
3. From the Kit, position Relay/Mounting Bracket Assembly over stud and
secure with the Keps Nut.
4. Disconnect the white wire of the Main Harness, from the Refill Valve.
5. Connect the piggy back terminal on the short white wire of the Relay/
Bracket Assembly to the Refill Valve and the white wire of the Main
FIG 1
GENERAL
The purpose of these instructions is to serve as a guide when installing one of the following kits and to pro-
vide a list of service replacement parts.
43147.0000 AUDIBLE ALERT KIT:
02618.0000 Relay, 120V SPDT
07441.0000 Bracket, Solenoid/Relay Mounting
02328.0000 Screw, Pan Head #6-32 X .375”
01510.0000 Lockwasher, Ext. Tooth #6
43142.0000 Wiring Harness
43147.0001 AUDIBLE ALERT KIT:
02618.0000 Relay, 120V SPDT
07441.0000 Bracket, Solenoid/Relay Mounting
02328.0000 Screw, Pan Head #6-32 X .375”
01510.0000 Lockwasher, Ext. Tooth #6
43142.0000 Wiring Harness
29969.1040 Circuit Board Assy, Dual SH DBC
(continued)
Harness to the piggy back terminal.
6. Loosen the clamp on the power cable connector and push
the 2 violet wires thru connector so they extend out the
bottom of the brewer, tighten the clamp.
7. Route the long white wire of the Relay/Bracket Assembly
up to the Main Control Board located in the hood.
8. Refer to Fig 3, disconnect the Main Harness from J11
connector of the Main Control Board. Refer to Fig 4, locate
the open port (J11-1) of the Main Harness Connector and
insert the terminal of the long white wire from the Relay/
Bracket Assembly.
Note: The Terminal must lock into the Connector. When
inserting terminal into connector, the slpit side of the ter-
minal must be facing the locking side of the connector as
shown, for the terminal to lock in place.
9. If a new Main Control Board is included in the Kit, proceed
to step 11. If the Kit does not include a new Main Control
Board, reconnect Main Harness to Main Control Board and
continue to step 10.
10. Connect USB Flash Programmer #40413.1009 to connec-
tor J1 on the Main Control Board to flash new software
into the Control Board, then proceed to step 16.
11. Refer to Fig 5, disconnect the funnel sensor(s) from con-
nector J9, the ribbon cable from connector J4, and the level
probe harness and server detect harness from connector J2
on the circuit board.
12. Remove the two mounting nuts securing the top of the circuit
board to the hood.
13. Tilt the circuit board inward to clear the display section and
lift out of the circuit board mount.
14. Place the bottom edge of new control board in the control
board mount (as shown), tilt the board forward, and secure
top of control board with the two mounting nuts.
15. Refer to Fig 5, connect all wires to the circuit board.
16. Install all Panels and Covers on the Brewer. Audible Alarm
may now be connected to the 2 violet wires extending out
the bottom of the Brewer.
Left Funnel Sensor
(Violet/White Violet)
Right Funnel Sensor
(Yellow/White Yellow)
Connector locking side
Split side of Terminal
J11-1
FIG 3
FIG 4
FIG 2
43148 050410
FIG 5
Violet wires from termi-
nals 5 & 7 of the relay to
be routed out the bottom
of brewer thru the power
cable connector
WHITE wires from termi-
nals A & B of the relay to
refill valve and J11-1 on
main circuit board

Other manuals for DUAL SH DBC

13

Other Bunn Kitchen Appliance Accessories manuals

Bunn 1.5 User manual

Bunn

Bunn 1.5 User manual

Bunn ThermoFresh SERVER Quick reference guide

Bunn

Bunn ThermoFresh SERVER Quick reference guide

Popular Kitchen Appliance Accessories manuals by other brands

contoure RV-9808 installation instructions

contoure

contoure RV-9808 installation instructions

Carrier 320720---751 THRU ---761 installation instructions

Carrier

Carrier 320720---751 THRU ---761 installation instructions

Weber Oven user manual

Weber

Weber Oven user manual

Diamond SA/60E Instructions for use and installation

Diamond

Diamond SA/60E Instructions for use and installation

Smeg KIT1A3-6 Instructions for the installer

Smeg

Smeg KIT1A3-6 Instructions for the installer

KitchenAid 5KSMFGA Use & care manual

KitchenAid

KitchenAid 5KSMFGA Use & care manual

Braun Multiquick Minipimer MR 10 manual

Braun

Braun Multiquick Minipimer MR 10 manual

West Elm Marble + Brass 2743412 instructions

West Elm

West Elm Marble + Brass 2743412 instructions

Smeg GP64ES quick start guide

Smeg

Smeg GP64ES quick start guide

Secura SPO-17GS user manual

Secura

Secura SPO-17GS user manual

Kenwood AX500 instructions

Kenwood

Kenwood AX500 instructions

Maytag 4396701T installation instructions

Maytag

Maytag 4396701T installation instructions

Bosch MUZ9HA1 instruction manual

Bosch

Bosch MUZ9HA1 instruction manual

Bosch MUZ5VL1 operating instructions

Bosch

Bosch MUZ5VL1 operating instructions

TurboChef CON-3002 Replacement guide

TurboChef

TurboChef CON-3002 Replacement guide

ML Accessories BATSCWM4 Installation & maintenance manual

ML Accessories

ML Accessories BATSCWM4 Installation & maintenance manual

Miele professional A 502 operating instructions

Miele professional

Miele professional A 502 operating instructions

Russell Hobbs 155372 instructions

Russell Hobbs

Russell Hobbs 155372 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.