Busch-Welcome H8131 P-03 Series User manual

2TMD042200D0021 │22.06.2022
Product manual
Busch-Welcome®IP
H8131.P.-.-03 Mini video outdoor station
H8136.P.-.-03 Mini video outdoor station

Table of contents
Product manual
2TMD042200D0021
│
2
Table of c ontents
1Notes on the instruction manual............................................................................................................4
2Safety..................................................................................................................................................4
3Intended use........................................................................................................................................4
4Environment.........................................................................................................................................5
4.1 Busch-Jaeger devices................................................................................................................5
5Product description...............................................................................................................................6
5.1 Device type ...............................................................................................................................6
5.2 Control elements........................................................................................................................7
5.3 Terminal description...................................................................................................................8
5.4 Lock type and connection...........................................................................................................9
6Technical data....................................................................................................................................10
7Mounting/Installation...........................................................................................................................11
7.1 Requirement for the electrician.................................................................................................11
7.2 Mounting.................................................................................................................................12
7.2.1 Preparation .......................................................................................................................... 12
7.2.2 Installation height.................................................................................................................. 12
7.2.3 Installation situation.............................................................................................................. 13
7.2.4 Surface-mounted installation................................................................................................. 14
7.2.5 Flush-mounted installation .................................................................................................... 16
7.2.6 Cavity wall installation........................................................................................................... 17
7.2.7 Replacing the nameplate ...................................................................................................... 18
8Commissioning...................................................................................................................................19
8.1 Configure the settings on indoor station....................................................................................19
8.1.1 Outdoor station enters engineering mode .............................................................................. 19
8.1.2 Indoor station enters engineering settings.............................................................................. 20
8.1.3 Local device settings ............................................................................................................ 21
8.1.4 Lock management................................................................................................................ 23
8.1.5 Door status detection............................................................................................................ 24
8.1.6 Sound setting....................................................................................................................... 25
8.1.7 Anti-flicker setting................................................................................................................. 26
8.1.8 Set the function of pushbutton............................................................................................... 27
8.1.9 Time sync setting.................................................................................................................. 28
8.1.10 Compatible mode setting ...................................................................................................... 29
8.1.11 Updating the firmware........................................................................................................... 30
8.1.12 Viewing the version............................................................................................................... 31
8.1.13 Serial number....................................................................................................................... 32
8.1.14 Signature............................................................................................................................. 33
8.2 Configure the settings on SmartAP...........................................................................................34
8.2.1 Adding mini outdoor station................................................................................................... 34
8.2.2 Configure the settings........................................................................................................... 35
8.3 Card management...................................................................................................................42
8.4 Restoring to factory default.......................................................................................................44

Table of contents
Product manual
2TMD042200D0021
│
3
9Cyber security....................................................................................................................................45
9.1 Disclaimer ...............................................................................................................................45
9.2 Performance and service .........................................................................................................45
9.3 Deployment guideline...............................................................................................................46
9.4 Upgrading................................................................................................................................46
9.5 Backup/Restore.......................................................................................................................46
9.6 Malware prevention solution.....................................................................................................46
10 Notice................................................................................................................................................47

Notes on the instruction manual
Product manual
2TMD042200D0021
│
4
1Notes on the instruction manual
Please read through this manual carefully and observe the information it contains. This will
assist you in preventing injuries and damage to property and ensure both reliable operation and
a long service life for the device.
Please keep this manual in a safe place. If you pass the device on, also pass on this manual
along with it. Busch-Jaeger accepts no liability for any failure to observe the instructions in this
manual.
2Safety
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect
contact with live components.
This can result in electric shock, burns or even death.
– Disconnect the mains power supply prior to installation and/or disassembly!
– Permit work on the 100-240 V supply system to be performed only by
specialist staff!
3Intended use
As part of the Busch-Welcome®IP system, this device can only be used with accessories from
that system.

Environment
Product manual
2TMD042200D0021
│
5
4Environment
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with household
waste.
– The device contains valuable raw materials that can be recycled. Therefore,
dispose of the device at the appropriate collecting facility.
4.1 Busch-Jaeger devices
All packaging materials and devices from Busch-Jaeger bear the markings and test seals for
proper disposal. Always dispose of the packing materials and electric devices and their
components via an authorized collection facility or disposal company.
Busch-Jaeger products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2012/19/EU WEEE and 2011/65/EU RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)

Product description
Product manual
2TMD042200D0021
│
6
5Product description
5.1 Device type
Article
number Product ID Product name Colour Size (HxWxD)
Unit: mm
H81313P1-
A-03 2TMA130010A0003 Mini video outdoor station,
1 button, ID, SM Aluminum
alloy 99 x 168 x 26
H81313P2-
A-03 2TMA130010A0006 Mini video outdoor station,
2 buttons, ID, SM Aluminum
alloy 99 x 168 x 26
H81363P1-
A-03 2TMA130010A0009 Mini video outdoor station,
1 button, ID,FM Aluminum
alloy 105 x 180 x 43
H81363P2-
A-03 2TMA130010A0012 Mini video outdoor station,
2 buttons, ID, FM Aluminum
alloy 105 x 180 x 43
H81364P1-
A-03 2TMA130010A0015 Mini video outdoor station,
1 button, FM Aluminum
alloy 105 x 180 x 43

Product description
Product manual
2TMD042200D0021
│
7
5.2 Control elements
No. Description
1Indicator flashes slowly: ringing
Indicator flashes quickly: busy line
2Call indicator
3Unlock indicator
4 Speaker and microphone integration
5Round pushbutton
4
5
1
2
3

Product description
Product manual
2TMD042200D0021
│
8
5.3 Terminal description
No. Description
1 Connector for the sensor used for door status detection
2Connector for exit button
3Plug-in clamps (LOCK...AGND) for door opener
4Plug-in clamps (COM...NC...NO) for floating output
5 Plug-in clamps (DC+...GND) for standalone power supply
6 LAN (PoE)
7N/A
DS
NC COM NO GND DC+
LAN
1
23
4 5
6
7
LOCKAGNDEXIT

Product description
Product manual
2TMD042200D0021
│
9
5.4 Lock type and connection
Lock type Pic Operation type Voltage Wiring type
Electrical strike
lock, 12V Power on to open 12 V
⎓
/~ Type A/B
Electrical strike
lock, 24V Power on to open 24 V
⎓
/~ Type B
Electrical rim
lock, 12 V Power on to open 12 V
⎓
Type A/B
Electrical
mortise lock Power off toopen 12 V
⎓
Type C
Magnetic lock Power off toopen 12/24 V
⎓
Type C
AGND
GND
NO
DC+
NC
DS
LOCK
COM
EXIT
AGND
GND
NO
DC+
NC
DS
LOCK
COM
EXIT
AGND
GND
NO
DC+
NC
DS
LOCK
COM
EXIT
+
+
+
-
--
PS
PS
TypeA
Type B
Type C

Technical data
Product manual
2TMD042200D0021
│
10
6Technical data
Designation Value
Rating voltage 24 V
⎓
Operating voltage range 20-27 V
⎓
Rating current 27 V
⎓
, 310 mA
24 V
⎓
, 350 mA
Operating temperature -40 °C…+55 °C
Product dimensions 99 mm x 168 mm × 26 mm (H8131.P.-.)
105 mm x 180 mm × 43 mm (H8136.P.-.)
Camera type CMOS
Camera viewing angle 104°
Power supply for door opener 15 V
⎓
, 4A impulse, max. 250 mA holding
Floating output for door opener 30 V
⎓
, 3 A
IP level IP 54
IK level IK 07
Network connection standard IEEE802.3, 10/100 Mbps, autoMDI/MDI-X

Mounting/Installation
Product manual
2TMD042200D0021
│
11
7Mounting/Installation
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect
contact with live components.
This can result in electric shock, burns or even death.
– Disconnect the mains power supply prior to installation and/or disassembly!
– Permit work on the 100-240 V supply system to be performed only by
specialist staff!
7.1 Requirement for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
– Incorrect installation endangers your life and that of the user of the electrical
system.
– Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation
are as follows:
– Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect
2. Secure against being re-connected
3. Ensure there is no voltage
4. Connect to earth and short-circuit
5. Cover or barricade adjacent live parts.
– Use suitable personal protective clothing.
– Use only suitable tools and measuring devices.
– Check the type of supply network (TN system, IT system, TT system) to
secure the following power supply conditions (classic connection to ground,
protective grounding, necessary additional measures, etc.).

Mounting/Installation
Product manual
2TMD042200D0021
│
12
7.2 Mounting
7.2.1 Preparation
Use gloves to protect yourself against cuts.
7.2.2 Installation height
1.5 m
5 feet

Mounting/Installation
Product manual
2TMD042200D0021
│
13
7.2.3 Installation situation
Note
The following installation situations must be avoided without fail to ensure
picture quality:
■Direct light
■Direct sunlight
■Extremely bright picture background
■Highly reflective walls on the opposite side of the door station

Mount
ing/Installation
Product manual
2TMD042200D0021
│
14
7.2.4 Surface-mounted installation
Product dimension
Surface-mounted on the wall
99 mm 26.5 mm
78 mm
62 mm
62 mm
83 mm
60 mm
168 mm
147 mm
3
2
1
Screwshaft: 4⌀
Screw length: 25mm≥
Mountingscrew x 4

Mounting/Installation
Product manual
2TMD042200D0021
│
15
Surface-mounted on the box (e.g. VDE box)
3
2
1
Screw shaft: 4⌀
Screw length: 25 mm≥
Mountingscrew x4

Mounting/Installation
Product manual
2TMD042200D0021
│
16
7.2.5 Flush-mounted installation
Product dimension
Flush-mounted with pre-installation box
105 mm
180 mm
53 mm
174 mm
99 mm 45 mm99 mm
174 mm
3
2
1
Screw shaft: 4⌀
Screw length: 25 mm≥
Mountingscrewx4

Mounting/Installation
Product manual
2TMD042200D0021
│
17
7.2.6 Cavity wall installation
Product dimension
Mounting
105 mm
180 mm
43 mm 90 mm
168mm
92 mm
97 mm
120mm
170mm
Screw shaft: 4⌀
Screw length: 25 mm≥
Mountingscrewx4
1
2
3
4
5

Mounting/Installation
Product manual
2TMD042200D0021
│
18
7.2.7 Replacing the nameplate
3
4
6
5
122

Commissioning
Product manual
2TMD042200D0021
│
19
8Commissioning
8.1 Configure the settings on indoor station
8.1.1 Outdoor station enters engineering mode
Note
The mini outdoor station must be on the same network as the indoor station.
Please follow the steps below,
■Power up the mini outdoor station, the three indicators light up green.
■After a period of time, the three indicators go out.
■Hold the first pushbutton for 5 s.
■When the pushbutton module and the three indicators are flashing green at the same time,
the mini outdoor station enters engineering mode.
Pushbutton module
First pushbutton
Unlock indicator

Commissioning
Product manual
2TMD042200D0021
│
20
8.1.2 Indoor station enters engineering settings
On the extra screen of indoor station, click "System" to access the corresponding screen.
On the "System settings" screen, click "Engineering settings", enter the engineering password
and then click "Outdoor station settings" to access the corresponding screen.
This manual suits for next models
11
Table of contents
Other Busch-Welcome Intercom System manuals