manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cablematic
  6. •
  7. Adapter
  8. •
  9. Cablematic BLE-485C User manual

Cablematic BLE-485C User manual

BLE RS-485 Serial Adapter User Manual V1.3
Bluetooth V4.2 BLE RS-422/485 Serial Adapter
Model: BLE-485C
1. Package co te t:
BLE RS-422/485 adapter
White Box Dimension: x 6 x 5
(cm)
Total Package Weight: 05 g
Package Contents:
BLE 422/485 adapter x
A4 User manual x
Mini USB Cable x
2. Profile:
2.1 Top view:
LED Status Descriptio
Data LED flash Data transmission
Data LED solid on No data transmission
Link LED solid on BLE Link
1
TX-,TX+,RX-,RX+
Mini USB (Power)
▲+ (5~27 VDC)
▼ GND
Reset to Default
LED:
Link: Blue
PWR/Data: Red
Radio Frequency
area: Don’t cover
any metal material
or painting.
BLE RS-485 Serial Adapter User Manual V1.3
Link LED flash No Link
Data & Link LED solid on OTA Mode
2. Rear view:
Setup Modbus Stop
Bit
Parity Role Baud Rate
DIP9 DIP8 DIP7 DIP6 DIP5 DIP4 DIP3 DIP2 DIP
0: Switch
:
Command
0: Normal
: Add CRC
RS485 only
0: 1
: 2
00: No e
0 : Odd
0: Odd
: Even
0:Slave 0:2400
:4800
000:9600
00 : 9200
0 0:38400
0 :57600
00: 5200
0 :230400
Remark:
. 000000000 by default, in red bold character
2. The GATT service and AT command will support more settings than the DIP switch,
please check the page 4 section 5 and page 5 section 6.
3. Power supply:
3. Voltage: 5~27 VDC, Do ’t exceed the limit.
3.2 There’re 3 ways to power the adapter: Mini USB, Terminal Block and pin9 of DB9,
please choose one. Do ’t power the adapter by more tha two sources.
3.3 The mini USB cable is inside the standard package.
4. Specificatio s:
4. Default value: (BLE Peripheral)
Baud rate: 9,600 bps
Data bit: 8
2
DIP Switch
▲ RS-485
▼ RS-422
Terminal Block
BLE RS-485 Serial Adapter User Manual V1.3
Parity: none
Stop bit:
Flow control: none
Device Name: BLE 485
4.2 COM port:
Baud Rate: .2/2.4/4.8/9.6/ 9.2/38.4/57.6/ 5.2/230.4/460.8/92 .6 Kbps
Parity: none/even/odd
Stop bit: / .5/2
Data bit: 7/8
Remark: The GATT service and AT command will support all the functions, please
check the page 4 section 5 and page 5 section 6.
4.3 Range: max. 50 m in open space
4.4 TX Power: Max. 3 dBm
4.5 RX Sensitivity: -89 dBm typical
4.6 TX current consumption of 5.6 mA (radio only, 0 dbm)
4.7 Operation Temperature: –40 °C to +70 °C
4.8 Dimensions: 8 .6 mm (L) x 3 .75 mm (W) x 7 mm (H)
4.9 Antenna Gain: max. 2 dB
Remark: All contents are subject to change without notice.
5. GATT Service:
5. Architecture:
3
Device Informaon
Firmware Revision S ring
NOTIFY
RxDa a
BLE_CONF
MacID
DeviceName
DeviceName
PinID_Se+ng
Serial BLE Service
Se Charac eriscNo-caon(Char)
Se Charac eriscNo-caon (Char)
Se Charac eriscNo-caon(Char)
wri eCharac erisc(Char)
wri eCharac erisc(Char)
wri eCharac erisc(Char)
wri eCharac erisc(Char)
wri eCharac erisc(Char)
wri eCharac erisc(Char)
Mobile APP
SERIAL
BLE RS-485 Serial Adapter User Manual V1.3
5.2 Programming Interfaces:
GATT UUID
UUID_Device Information 0000 80A-0000- 000-8000-00805F9B34FB
UUID_Firmware Revision String 00002A26-0000- 000-8000-00805F9B34FB
UUID_NOTIFY (~20 bytes) 0003 234-0000- 000-8000-00805F9B0 30
UUID_RxData (~20 bytes) 0003 234-0000- 000-8000-00805F9B0 3
UUID_MacID (6 bytes) 0003 234-0000- 000-8000-00805F9B0 33
UUID_DeviceName ( 5 bytes) 0003 234-0000- 000-8000-00805F9B0 34
UUID_Reboot ( bytes) 0003 234-0000- 000-8000-00805F9B0 35
UUID_PinID_Setting (6 bytes) 0003 234-0000- 000-8000-00805F9B0 36
UUID_BLE_CONF (7 bytes) 0003 234-0000- 000-8000-00805F9B0 32
Byte0 Byte Byte2 Byte3
Data bit RS-485 CRC Stop Bit Parity Bit
7,8 0x0 :on
0x00:off
2:
3: .5
0x02 : No Parity
0x0 : Odd Parity
4
BLE RS-485 Serial Adapter User Manual V1.3
4:2 0x00 : Even Parity
Byte4 Byte5 Byte6
Baud Rate Device Mode Reset To Default
00:9600
0 : 9200
02:38400
03:57600
04: 5200
05:230400
06:2400
07:4800
08: 200
09:460800
0:92 600
0x00: Peripheral 0x0 : Reset
6. Comma d set via COM port:
Comma d Value Descriptio
AT Check the connection status between control terminal and the RS-232
adapter. Response: “OK” when the connection is ok. Response:
“ERROR” when the connection is not ok.
AT Test the RS-232 status when first connect the adapter with the
controller.
(Default) N The command will disable the auto link function.
? Inquire the current setting.
BAUD= This command is used to specify the baud rate of COM port.
The command will need 200 ms delay.
200 200 bps
2400 2400 bps
4800 4800 bps
9600 9600 bps
(Default) 9200 9200 bps
38400 38400 bps
57600 57600 bps
5200 5200 bps
230400 230400 bps
460800 460800 bps
92 600 92 600 bps
? Inquire the current baud rate.
BIT=
7 7 data bit
8 8 data bit
? Inquire the current data bit
5
BLE RS-485 Serial Adapter User Manual V1.3
DEFAULT= This command is used to restore the default settings and originate a
warm start.
Y Restore the default settings (e.g. 9200 bps).
The command will re-start the system for second.
DFU= Device Firmware Upgrade via PC software. OTA (Over the air) is
available to upgrade the firmware by APP
Y
ECHO= This command is used to specify whether the adaptor echoes
characters received from the UART back to the DTE/DCE.
N Command characters received from the UART are not echoed back to
the DTE/DCE.
(Default) Y Command characters received from the UART are echoed back to the
DTE/DCE.
? Inquire the current setting.
FLOW= This command enable or disable flow control signals (CTS/RTS) of the
UART port. Note, the setting is not affected by DEFAULT.
The command will need second delay.
(Default) N Disable flow control.
Y Enable flow control.
? Inquire the current setting
NAME= This command is used to specify a device name for the adaptor.
You can specify a friendly name using 0 to 9, A to Z, a to z, space and
–, which are all valid characters. Note that “first space or -, last space or
– isn’t permitted”. The default name is “Serial Adaptor”.
(Default) BLE232 Default device name
xx….xx “xx….xx” is a character string with the length from 2 to 30.
R Restore the default settings name=“BLE Serial”.
? Inquire the name of the local adaptor.
PARITY= This command is used to specify parity bit setting of COM port.
The command will need 200 ms delay.
(Default) N None parity bit
O Odd parity
E Even parity
? Inquire the current setting.
PIN= This command is used to specify a PIN code. The default PIN is
“ 23456”. Paired adaptors should have a same PIN. This command is
used to specify a PIN.
(Default) 23456
xx….xx “xx….xx” is a 6 number 0~9
? Inquire the current PIN.
PROMPT= The command is used to decide whether result messages are prompted
when Setup commands are executed. The result messages are:
OK/ERROR for command execution.
(Default) Y Prompt result messages.
N Not prompt result messages.
? Inquire the current setting.
STOP= This command is used to specify one or two stop bits of COM port.
6
BLE RS-485 Serial Adapter User Manual V1.3
The command will need 200ms delay.
(Default) One stop bit.
2 Two stop bits.
? Inquire the current setting.
VERSION= This command is used to inquiry the firmware version.
? Inquire the version codes.
7. RS-485 Wire co ectio
8. APP Dow load:
Android: iOS:
APP Sample code: Please contact the supplier for the test sample code.
The APP is used for the configuration and the data transmission test.
7
Scan BLE Setup mode
BLE RS-485 Serial Adapter User Manual V1.3
Scan and select one. Connect and configure Data transmission test.
8
Disconnect
TX area
RX area
Data mode
Clear data
and log
Device list
Select one Enable
Central
Setup
Reset
Default
Serial Port setting: Baud rate, Data
bit, Stop bit, Parity, flow control.

Other Cablematic Adapter manuals

Cablematic RW13 User manual

Cablematic

Cablematic RW13 User manual

Cablematic USB 3.0 DISPLAY ADAPTER User manual

Cablematic

Cablematic USB 3.0 DISPLAY ADAPTER User manual

Cablematic BLE RS-232 Series User manual

Cablematic

Cablematic BLE RS-232 Series User manual

Popular Adapter manuals by other brands

IOGear Cardbus Card GPU202  GPU202 GPU202 Manual de usuario

IOGear

IOGear Cardbus Card GPU202 GPU202 GPU202 Manual de usuario

network WOC-2-50-50 user manual

network

network WOC-2-50-50 user manual

Mobility Sound BTD-2N4 user manual

Mobility Sound

Mobility Sound BTD-2N4 user manual

Sygonix 1765333 operating instructions

Sygonix

Sygonix 1765333 operating instructions

Dension Gateway Five General installation guide

Dension

Dension Gateway Five General installation guide

NETGEAR XAV1101 installation guide

NETGEAR

NETGEAR XAV1101 installation guide

HBC HD-uDTA Setup Instruction

HBC

HBC HD-uDTA Setup Instruction

SMC Networks WCB-G2 FICHE user guide

SMC Networks

SMC Networks WCB-G2 FICHE user guide

Logitech HD 200a Getting started guide

Logitech

Logitech HD 200a Getting started guide

Technoton DUT-E AF Operation manual

Technoton

Technoton DUT-E AF Operation manual

Jabra LINK 220 quick start guide

Jabra

Jabra LINK 220 quick start guide

Westinghouse JS-A002 instruction manual

Westinghouse

Westinghouse JS-A002 instruction manual

StarTech.com DKT31CHVL quick start guide

StarTech.com

StarTech.com DKT31CHVL quick start guide

Rayson Technology BTD-434 user manual

Rayson Technology

Rayson Technology BTD-434 user manual

Terra UD104 instructions

Terra

Terra UD104 instructions

D-Link DWA-135A1 user manual

D-Link

D-Link DWA-135A1 user manual

Funkwerk bintec WI-Client manual

Funkwerk

Funkwerk bintec WI-Client manual

RIDGID 44823 instructions

RIDGID

RIDGID 44823 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.