Cadac 346 User manual

503-0386 LEV21
USER INSTRUCTIONS
NOTE! PRODUCT MAY VARY FROM ILLUSTRATIONS
Model: 346-10-QR
DUAL POWER PAK
MODEL No: 346, 346-10-QR
EN DE NL FR NO DK ES IT PL SE FI TR
503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 1503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 1 2022/10/05 14:04:422022/10/05 14:04:42

EN
Recycling packaging material. Place the packaging material in the appropriate recycling waste bins
wherever possible.
Explanation of Symbols
503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 2503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 2 2022/10/05 14:04:422022/10/05 14:04:42

11
CAUTION
Provide ample ventilation. Do not use this appliance in an unventilated space to avoid endangering your life. If still more gas
appliances and/or occupants using gas are added to the space, additional ventilation must be provided.
IMPORTANT
Read these instructions carefully so as to familiarise yourself with the appliance before fiting the appliance to a gas catridge.
Retain these instructions for future reference.
1. Safety Information
• The purpose of this appliance is to be a light weight, compact power source for
CADAC | DOMETIC BBQ products when the user does not want to use a large LPG
cylinder. The user simply connects two gas cartridges to the Dual Power Pak and then
to a suitable CADAC | DOMETIC BBQ appliance, or another compatible unit.
• This regulator complies with EN16129:2013
• Appliance category: I3B(28-30mbar) All EU, NO, IS, CH, TR, DE, AT and LU
• Appliance category: I3B(50mbar) DE, AT and LU
• Only to be used with EN417 type disposable cartridges (CADAC CA445,CA500).
• The gas cartridge is to be used only in the upright position.
• Gas BBQ appliances require ventilation for efficient performance and to ensure the
safety of users and other persons in close proximity.
• The Power Pak is fitted with a regulator with a maximum supply rate of 1.0kg/hour.
• Never place the Power Pak on a stove, and always keep it at least 1 meter away
from any source of heat, and ensure it is not placed in an environment where the
temperature will exceed 50°C.
• Always store, transport or use the Power Pak in an upright position.
• When not in use, keep the valve closed, even if it is empty.
• Check that the seals (Fig. 1) are in place and in good condition before connecting the
gas cartridge to the appliance. Do not use the appliance if it has a damaged or worn
seal. If in doubt, replace the seal before use.
• The appliance should only be used in a well-ventilated location (minimum ventilation
requirement 5m3/h) in order to satisfy official ventilation standards for the supply of
sufficient combustion air and to avoid the dangerous building up of unburned gases.
• Gas cartridges must be fitted or changed in a well-ventilated location, preferably
outside and away from any sources of ignition, such as naked flames, pilots, electric
fires and away from other people.
• Never leave the appliance unattended when in use.
• Do not modify the appliance. Do not use it for anything for which it has not been
designed.
• Do not move the Dual Power Pak during operation.
• Do not use the Dual Power Pak in small enclosed spaces without ventilation.
• The Power Pak is guaranteed for 2 years against factory defects. Normal wear and tear, valve components and plastic parts are excluded.
The same applies to damage caused by improper handling, misuse or repairs by an unauthorized low-pressure gas dealer. Liability is limited
to the replacement of products.
• In normal conditions of use, in order to ensure the correct operation of the Power Pak, it is recommended that this regulator is changed
within 10 years of the date of manufacture.
Leaks
• Do not use an appliance which is leaking, damaged or which does not operate properly (malfunctioning).
• If you suspect a gas leak, soapy water must be applied to the joints (the appliance must not be fully immersed in soapy water as this may result
in an unsafe operation of the appliance).
• To check the gas cartridge for leaks, apply soapy water to the connection area of the gas cartridge and see if any bubbles are visible. Any
leakage will be seen as bubbles coming from the leakage point. If you cannot remedy any leakage, return the cartridge to your stockist.
Fig. 1
G1/4” LH
Seal 7/16”
1m
1m
1m
1m
EN
Country Name and Abbreviations
AE = United Arab Emirates AL = Albania AT = Austria BE = Belgium CH = Switzerland
CZ = Czech Republic DE = Germany DK = Denmark ES = Spain FI = Finland
FR = France GB = United Kingdom GR = Greece HR = Croatia IT = Italy
JP = Japan KR = Korea NL = Netherlands NO = Norway PL = Poland
PT = Portugal RO = Romania RU = Russia RS = Serbia SI = Slovenia
SK = Slovakia SE = Sweden TR = Turkey ZA = South Africa
503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 1503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 1 2022/10/05 14:04:432022/10/05 14:04:43

22
2. Assembly
• Before operating the appliance, ensure all seals are in good condition. If you are
unsure, replace the seals.
• Ensure that the hose is connected securely to the valve outlet of the Dual Power Pak.
• Connect the other end of the hose securely to the BBQ appliance you wish to operate.
• First ensure the control knob on the BBQ appliance you are going to operate is in the
“off” position.
• Insert the two gas cartridges into the unit by screwing them in place (Fig. 2).
346
1: Hand wheel (17mm Hex) and hose component
2: Move the handle wheel to the end of the hose sliding it over the brass nut.
3: Connect brass nut to the inlet of the BBQ appliance, turn the hand wheel to tighten.
4: Test the connection for leaks before use.
Fig. 2
3. Operating the Dual Power Pak
• Turn the control knob on the Dual Power Pak anti-clockwise to increase the gas flow (Fig. 3).
• Then turn on the BBQ appliance you wish to operate, and light the BBQ appliance.
• Adjust the Dual Power Pak control knob, to reach the desired level of gas flow to the BBQ appliance.
• Heat control to be done using the BBQ appliance control knob.
• The supply rate of the Dual Power Pak unit may be adjusted by turning the control valve on the Dual Power Pak from fully closed to fully
open.
To disassemble the unit
• Close the control knob.
• Remove the cartridge by unscrewing it.
• Disconnect the hose from the appliance and pack the unit away for storage.
Brass nut Hand Wheel
1. 2. 3.
Fig. 3 Fig. 4
(Low pressured gas)
High pressured gas
346-QR
1: Remove QR male.
2: Connect QR male to the inlet of your BBQ appliance and turn to tighten.
3: Connect QR female to QR male by pushing the QR female onto the QR male.
4: Test the connection for leaks before use.
QR Male
1. 2. 3.
QR Female
EN
503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 2503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 2 2022/10/05 14:04:452022/10/05 14:04:45

33
6. Warranty
CADAC Europe BV hereby warrants to the ORIGINAL PURCHASER of this product, that it will be free of defects in material and workmanship
from the date of purchase for 2 years.
This warranty will only apply if the unit is assembled and operated in accordance with the printed instructions.
CADAC Europe BV may require reasonable proof of your date of purchase. THEREFORE, YOU SHOULD RETAIN YOUR SALES SLIP OR
INVOICE.
This Limited Warranty shall be limited to the repair or replacement of parts that prove defective under normal use and service and which on
examination shall indicate, to CADAC Europe BV’s satisfaction, they are defective. Before returning any parts, contact the customer service
representative in your region using the contact information provided with your manual. If CADAC Europe BV confirms the defect and
approves the claim, CADAC Europe BV will elect to replace such parts without charge. CADAC Europe BV will return parts to the purchaser,
freight or postage prepaid.
This Limited Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication,
vandalism, improper installation or improper maintenance or service, or failure to perform normal and routine maintenance, including but
not limited to damage caused by insects within the burner tubes, as set out in this owner’s manual.
Deterioration or damage due to severe weather conditions such as hail, hurricanes, earthquakes or tornadoes, discoloration due to
exposure to chemicals either directly or in the atmosphere, is not cover by this Limited Warranty.
There are no other express warrants except as set forth herein and any applicable implied warranties of merchantability and fitness are
limited in duration to the period of coverage of this express written Limited Warranty. Some regions do not allow limitation on how long an
implied warranty lasts, so this limitation may not apply to you.
CADAC Europe BV is not liable for any special, indirect or consequential damages. Some regions do not allow the exclusion or limitation of
incidental or consequential damages, to this limitation or exclusion may not apply to you.
CADAC Europe BV does not authorize any person or company to assume for it any obligation or liability in connection with the sale,
installation, use, removal, return, or replacement of its equipment; and no such representations are binding on CADAC Europe BV.
This Warranty applies only to products sold at retail.
4. Cleaning
• It is recommended to clean the device aer each use. This extends the life of your device.
• To clean the body of the device, simply wipe it with a damp cloth and, if necessary, a little washing-up liquid.
• DO NOT IMMERSE IN WATER as this may cause damage to the unit
• Do not use scouring agents as they can damage the surfaces.
5. Storage
• Disconnect the hose from the appliance and pack the unit away for storage.
• Cartridges should always be stored in a cool, dry, well-ventilated area, away from sources of heat or flame
EN
503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 3503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 3 2022/10/05 14:04:452022/10/05 14:04:45

4848
CADAC SOUTH AFRICA
P.O. Box 43196,
Industria, 2042 South Africa
Tel: +27 11 470 6600
Email: [email protected].za
www.cadacsa.co.za
CADAC EUROPE
Ratio 26, 6921 RW Duiven
The Netherlands
Tel: +31 26 319 7740
Email: info@cadaceurope.com
www.cadacinternational.com
CADAC GERMANY
Ratio 26, 6921 RW Duiven
The Netherlands
Tel: +31 26 319 7740
Email: info@cadaceurope.com
www.cadacinternational.com
CADAC FRANCE
Le Viallon, 42520 Veranne
France
Tel: +33 4 74 78 13 65
Email : info@cadaceurope.com
www.cadacinternational.com
CADAC SOUTH EAST EUROPE
Bulevar oslobodjenja 285
Tel: +381 11 339 2700
Email: [email protected]
www.cadac.rs
CADAC SCANDINAVIA
Millarco International A/S
Rokhøj 26
8520 Lystrup, Denmark
Phone: +45 87 43 42 00
millarco@millarco.dk
www.millarco.com
CADAC ITALY
Brunner SRL/GMBH
via Buozzi, 8
39100 Bolzano (Italy)
Tel: +39 0471 542900
Email: info@brunner.it
www.brunnerinternational.com
CADAC CHINA
Room 807, Huayue International
Building, No.255 Tiangao Road,
South
Yinzhou business district,
Ningbo, China
Tel:+86 574 87723937
Email: [email protected].cn
CADAC DENMARK
Camper Fritid
Industrivej 11
6640 Lunderskov, Denmark
Tel.: +45 7558 5255
Email: info@camper.dk
www.camper.dk
CADAC FINLAND
OY KAMA FRITID AB
Koivuhaantie 2-4 B
01510 VANTAA
00358 20 792 0310
info@kamafritid.fi
CADAC IRAN
Robin Bazarganan Carin Co.
Unit D, 6th Floor, Negin Zafar
Building, No.1327,
Shariati Street, Tehran, Iran
Tel: +98 21 276 00 781
Mail: [email protected]
CADAC MOZAMBIQUE
Exclusive Brands Africa
492 Avenida Namaacha
Maputo, Mozambique
Tel: +258 21 406254
www.cadac.co.mz
CADAC NEW ZEALAND
Riverlea Group (Pty) Ltd
2A Maui Street, Pukete,
Hamilton 3200, New Zealand
Tel: +64 7 847 0204
Email: sales@riverleagroup.co.nz
www.riverleagroup.co.nz
CADAC SWEDEN & NORWAY
KAMA FRITID AB
0046 36 353700
CADAC U.A.E.
Supreme Impex General Trading
LLC Office No. 1801-7 Latifa
Tower Sheikh Zayed Road
Dubai, UAE
CADAC ZAMBIA
Exclusive Brands Africa Limited
7225A Kachidza Road
Light Industrial Area
Lusaka, Zambia
Tel: +260 211 842015
Tel: +260977 345034
Email: [email protected]
CADAC ZIMBABWE
Exclusive Brands Africa
Unit 8 Birkenhead Park
43 Josiah Chinamano Street
Belmont, Bulawayo
Tel: +263 971 740 (Bul)
Tel: +263 479 2564 (Har)
www.cadac.co.zw
CADAC POLAND
Kamai
Wola Batorska 461
32-007 Wola Batorska Poland
Tel: +48 12 635 1373
Email: [email protected]
www.kamai.pl
CADAC Czech Rep.
RÖSLER Praha spol. s r.o.
K Horkám 19/21
102 00 Praha 10 Česká republika
Tel: +420 267 188 011
Email: info@rosler.cz
www.rosler.cz
CADAC UK
14 Deanfield Court,
Link59 Business Park,
Clitheroe, Lancashire,
BB7 1QS
United Kingdom.
Tel: +44 (0) 333 2000363
E:mail: [email protected]
www.cadacinternational.com
CADAC MONTENEGRO
City kvart Z1L6
81000 Podgorica, Montenegro
Tel 38220671446, 38269020063
E-mail: [email protected]
503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 48503-0386 LEV21 (346, 346-10-QR) Dual Power Pak - User Manual (EU).indd 48 2022/10/05 14:05:172022/10/05 14:05:17
Other manuals for 346