Description
Aircompressorunitsareintended
toprovidecompressedairtopower
pneumatictools,operatesprayguns
andsupplyairforpneumaticvalvesand
actuators.Thepumpssuppliedwith
theseunitshaveoillubricatedbearings.
Asmallamountofoilcarryoveris
presentinthecompressedairstream.
Applicationsrequiringairfreeofoil
vaporshouldhavetheappropriate
filterinstalled.Theaircompressorunits
aretobemountedpertheinstructions
providedonasolidfloor.Anyotheruse
oftheseunitswillvoidthewarranty
andthemanufacturerwillnotbe
responsibleforproblemsordamages
resultingfromsuchmisuse.Refertothe
enclosedReplacementPartsManualto
identifycompressorassinglestageor
two-stage.
SafetyGuidelines
Thismanualcontainsinformation
thatisveryimportantto now
andunderstand.Thisinformation
isprovidedforSAFETYandto
PREVENTEQUIPMENTPROBLEMS.
Tohelprecognizethisinformation,
observethefollowingsymbols.
 Dangerindicates
 animminently
hazardoussituationwhich,ifnot
avoided,WILLresultindeathor
seriousinjury.
 Warningindicates
 apotentially
hazardoussituationwhich,ifnot
avoided,CO LDresultindeathor
seriousinjury.
 Cautionindicates
 apotentially
hazardoussituationwhich,ifnot
avoided,MAYresultinminoror
moderateinjury.
 Noticeindicates
 important
information,thatifnotfollowed,
maycausedamagetoequipment.
AirCompressors
RecordtheModelNo.,SerialNo.and
dateofpurchaseinthespacebelow.
ModelNo. ______________________
SerialNo. ______________________
Dateofpurchase _________________
Retainthesenumbersfor
futurereference.
Pleasereadandsavetheseinstructions.Readcarefullybeforeattemptingtoassemble,install,operateormaintainthe
productdescribed.Protectyourselfandothersbyobservingallsafetyinformation.Failuretocomplywithinstructions
couldresultinpersonalinjuryand/orpropertydamage!Retaininstructionsforfuturereference.
SeeWarrantyonpage10forimportantinformationaboutcommercialuseofthisproduct.
OperatingInstructions F2101, F2111, Q3010, Q3011, X2101, X2118
REMINDER:Keepyourdatedproofofpurchaseforwarrantypurposes!
Attachittothismanualorfileitforsafekeeping.
Unpacking
Whenunpac ingunit,inspectcarefully
foranydamagethatmayhaveoccurred
duringtransit.Ma esureanyloose
fittings,bolts,etc.,aretightenedbefore
puttingunitintoservice.Incaseof
questions,damagedormissingparts,
pleasecall1-800-543-6400forcustomer
assistance.Havetheserialnumber,
modelnumber,andpartslist(with
missingpartscircled)beforecalling.
DONO RE URN
HEPRODUC  O
HERE AILER!
 Donotoperate
 unitifdamaged
duringshipping,handlingoruse.
Damagemayresultinburstingand
causeinjuryorpropertydamage.
READ&FOLLOWALLINS RUC IONS
SAVE HESEINS RUC IONS
DONO DISCARD
GeneralSafety
CALIFORNIAPROPOSI ION65
 Thisproductorits
 powercordmay
containchemicals,includinglead,
knowntotheStateofCalifornia
tocausecancerandbirthdefects
orotherreproductiveharm.Wash
handsafterhandling.
 Youcan
 create
dustwhenyoucut,sand,
drillorgrindmaterials
suchaswood,paint,
metal,concrete,cement,orother
masonry.Thisdustoftencontains
chemicalsknowntocausecancer,
birthdefects,orotherreproductive
harm.Wearprotectivegear.
STOP�
IN255005AV2/12©2012
REGISTERYOURPRODUCTONLINENOW!http://www.chpower.net/reg
BreathableAirWarning
hiscompressor/pumpisNO 
equippedandshouldNO be
used“asis”tosupplybreathing
qualityair.Foranyapplicationof
airforhumanconsumption,you
mustfittheaircompressor/pump
withsuitablein-linesafetyand
alarmequipment. hisadditional
equipmentisnecessaryto
properlyfilterandpurifytheair
tomeetminimalspecifications
forGradeDbreathingas
describedinCompressed
GasAssociationCommodity
SpecificationG7.1,OSHA29
CFR1910.134,and/orCanadian
StandardsAssociations(CSA).
DISCLAIMEROFWARRAN IES
Intheeventthecompressoris
usedforthepurposeofbreathing
airapplicationandproperin-line
safetyandalarmequipment
isnotsimultaneouslyused,
existingwarrantiesarevoid,and
themanufacturerdisclaimsany
liabilitywhatsoeverforanyloss,
personalinjuryordamage.
All manuals and user guides at all-guides.com
2
OperatingInstructions
GeneralSafety
(Continued)
Sincetheaircompressorandother
components(materialpump,spray
guns,filters,lubricators,hoses,
etc.)usedma eupahighpressure
pumpingsystem,thefollowingsafety
precautionsmustbeobservedatall
times:
1. Readallmanuals
includedwiththis
productcarefully.Be
thoroughlyfamiliar
withthecontrolsand
theproperuseoftheequipment.
2. Followalllocalelectricalandsafety
codesaswellastheUnitedStates
NationalElectricalCodes(NEC)and
OccupationalSafetyandHealthAct
(OSHA).
3. Onlypersonswellacquaintedwith
theserulesofsafeoperationshould
beallowedtousethecompressor.
4. KeepvisitorsawayandNEVERallow
childreninthewor area.
5. Wearsafetyglassesandusehearing
protectionwhenoperatingtheunit.
6. Donotstandonorusetheunitasa
handhold.
7. Beforeeachuse,inspect
compressedairsystemandelectrical
componentsforsignsofdamage,
deterioration,wea nessorlea age.
Repairorreplacedefectiveitems
beforeusing.
8. Chec allfastenersatfrequent
intervalsforpropertightness.

 
Motors,electrical
equipmentandcontrols
cancauseelectricalarcs
thatwilligniteaflammablegasor
vapor.Neveroperateorrepairinor
nearaflammablegasorvapor.Never
storeflammableliquidsorgasesin
thevicinityofthecompressor.
 Never
 operate
compressorwithout
abeltguard.Thisunit
canstartautomatically
withoutwarning.Personalinjury
orpropertydamagecouldoccur
fromcontactwithmovingparts.
9. Donotwearlooseclothingor
jewelrythatwillgetcaughtinthe
movingpartsoftheunit.

 
Compressorpartsmay
behoteveniftheunitis
stopped.
10.Keepfingersawayfromarunning
compressor;fastmovingandhot
partswillcauseinjuryand/orburns.
11.Iftheequipmentshouldstart
tovibrateabnormally,STOP
theengine/motorandchec 
immediatelyforthecause.Vibration
isgenerallyanindicationoftrouble.
12.Toreducefirehazard, eepengine/
motorexteriorfreeofoil,solvent,
orexcessivegrease.
 AnASMEcode
 safetyreliefvalve
withasettingnohigherthan
200psifortwo-stagecompressors
or150psiforsinglestage
compressorsM STbeinstalled
intheairlinesorinthetankfor
thiscompressor.TheASMEsafety
valvemusthavesufficientflow
andpressureratingstoprotect
thepressurizedcomponentsfrom
bursting.Theflowratingcanbe
foundinthepartsmanual.The
maximumsafepressureratingfor
thepumpis200psi(two-stage)or
150psi(singlestage).Thesafety
valveintheintercoolerdoesnot
providesystemprotection.
 Maximum
 operating
pressureis175psifortwo-stage
compressorsand135psiforsingle
stagecompressors.Donotoperate
withpressureswitchorpilot
valvessethigherthan175psi
(two-stage)or135psi(single
stage).
13.NeverattempttoadjustASME
safetyvalve.Keepsafetyvalve
freefrompaintandother
accumulations.

 Never
attempttorepairor
modifyatank!Welding,
drillingoranyother
modificationwillweakenthetank
resultingindamagefromrupture
orexplosion.Alwaysreplaceworn,
crackedordamagedtanks.
14.Tan srustfrommoisturebuild-up,
whichwea ensthetan .Ma e
suretodraintan regularlyand
inspectperiodicallyforunsafe
conditionssuchasrustformation
andcorrosion.
 Drainliquidfrom
 tankdaily.
15.Fastmovingairwillstirupdust
anddebriswhichmaybeharmful.
Releaseairslowlywhendraining
moistureordepressurizingthe
compressorsystem.
SPRAYINGPRECAU IONS
 Donot
 spray
flammablematerialsin
vicinityofopenflameornear
ignitionsourcesincludingthe
compressorunit.
16.Donotsmo ewhensprayingpaint,
insecticides,orotherflammable
substances.
17.Useafacemas /
respiratorwhen
sprayingandsprayina
wellventilatedareato
preventhealthandfire
hazards.
18.Donotdirectpaintorothersprayed
materialatthecompressor.Locate
compressorasfarawayfrom
thesprayingareaaspossibleto
minimizeoversprayaccumulationon
thecompressor.
19.Whensprayingorcleaningwith
solventsortoxicchemicals,follow
theinstructionsprovidedbythe
chemicalmanufacturer.
Installation

 
Disconnect,tagandlock
outpowersourcethen
releaseallpressurefrom
thesystembeforeattemptingto
install,service,relocateorperform
anymaintenance.
 Donotliftor
 moveunitwithout
appropriatelyratedequipment.Be
suretheunitissecurelyattachedto
liftingdeviceused.Donotliftunit
byholdingontotubesorcoolers.Do
notuseunittoliftotherattached
equipment.
 Neverusethe
 woodshipping
skidsformountingthecompressor.
Installandoperateunitatleast
24inchesfromanyobstructionsin
aclean,wellventilatedarea.The
surroundingairtemperatureshould
notexceed100°F.Thiswillensure
anunobstructedflowofairtocool
compressorandallowadequatespace
formaintenance.
M�NU�L
All manuals and user guides at all-guides.com
3
F2101, F2111, Q3010, Q3011, X2101, X2118
Installation(Continued)
 Donotlocatethe
 compressorair
inletnearsteam,paintspray,
sandblastareasoranyothersource
ofcontamination.
NO E:Ifcompressoroperatesinahot,
moistenvironment,supplycompressor
pumpwithclean,dryoutsideair.Supply
airshouldbepipedinfromexternal
sources.Fortwo-stagecompressors
only,useadapter it(TF060502AV)
toconnectpipingtocompressor.Two
adapter itsareneededfortwo-stage
10and15HPunits.
ANKMOUN ING
Thetan shouldbeboltedintoaflat,
even,concretefloororonaseparate
concretefoundation.Vibrationisolators
shouldbeusedbetweenthetan leg
andthefloor.ModelMP367700AJ
isolatorpadsarerecommendedfor
horizontalunits.ModelMP345700AJ
isolatorpadsarerecommendedfor
verticalunits.Whenusingisolator
pads,donotdrawboltstight.Allow
thepadstoabsorbvibrations.When
isolatorsareused,aflexiblehoseor
couplingshouldbeinstalledbetween
thetan andservicepiping.

 Failure
toproperlyinstallthe
tankcanleadtocracks
attheweldedjointsand
possiblebursting.
PIPING
 Neveruseplastic
 (PVC)pipefor
compressedair.Seriousinjuryor
deathcouldresult.
Anytube,pipeorhoseconnectedto
theunitmustbeabletowithstandthe
temperaturegeneratedandretainthe
pressure.Allpressurizedcomponents
oftheairsystemmusthaveapressure
ratinghigherthanorequaltothe
200psifortwo-stagecompressorsor
150psiforsinglestagecompressors
ASMEsafetyvalvesetting.
Incorrectselectionandinstallationof
anytube,pipeorhosecouldresultin
burstingandinjury.Connectpiping
systemtotan usingthesamesize
fittingasthedischargeport.
INS ALLINGASHU -OFFVALVE
Ashut-offvalveshouldbeinstalled
onthedischargeportofthetan to
controltheairflowoutofthetan .
Thevalveshouldbelocatedbetween
thetan andthepipingsystem.
 Neverinstalla
 shut-offvalve
betweenthecompressorpump
andthetank.Personalinjuryand/
orequipmentdamagemayoccur.
Neverusereducersindischarge
piping.
Whencreatingapermanentlyinstalled
systemtodistributecompressedair,
findthetotallengthofthesystemand
selectpipesizefromthechart.Bury
undergroundlinesbelowthefrostline
andavoidpoc etswherecondensation
cangatherandfreeze.
Applyairpressuretothepiping
installationandma esurealljointsare
freefromlea sBEFOREunderground
linesarecovered.Beforeputtingthe
compressorintoservice,findandrepair
alllea sinthepiping,fittingsand
connections.
Chart1:MinimumPipeSizefor
CompressedAirLine(ininches)
LengthOfPiping
System(infeet)
CFM 25 50 100 250
10 1/2 1/2 3/4 3/4
20 3/4 3/4 3/4 1
40 3/4 1 1 1
60 3/4 1 1 1
100 1 1 1 1-1/4
DrainValve
IsolationPad
(availableseparately)
Tan
Discharge
Port
Tan Shut-OffValve
(availableseparately)
Discharge
Port
Tan Shut-OffValve
(availableseparately)
Pressure
Gauge
Pressure
Gauge
FactoryMounted
MagneticStarter
(notonallunits)
Pressure
Switch Pressure
Switch
Safety
Valve
Motor
Motor
Pump
Pump
Chec 
Valve
Discharge
Tube
Discharge
Tube
SafetyValve
Access
Figure1-VerticalUnitIdentification
All manuals and user guides at all-guides.com
Installation(Continued)
WIRING
 Allwiring
 andelectrical
connectionsmustbeperformedby
aqualifiedelectrician.Installations
mustbeinaccordancewithlocal
andnationalcodes.
 Overheating,short
 circuitingandfire
damagewillresultfrominadequate
wiring.
Wiringmustbeinstalledinaccordance
withNationalElectricalCodeandlocal
codesandstandardsthathavebeenset
upcoveringelectricalapparatusand
wiring.Theseshouldbeconsultedand
localordinancesobserved.Becertain
thatadequatewiresizesareused,and
that:
1. Serviceisofadequateampere
rating.
2. Thesupplylinehasthesame
electricalcharacteristics(voltage,
cyclesandphase)asthemotor.
3. Thelinewireisthepropersize
andthatnootherequipmentis
operatedfromthesameline.The
chartgivesminimumrecommended
wiresizesforcompressor
installations.
Recommendedwiresizesmaybelarger
thantheminimumsetupbylocal
ordinances.Ifso,thelargersizewire
shouldbeusedtopreventexcessive
linevoltagedrop.Theadditionalwire
costisverysmallcomparedwiththe
costofrepairingorreplacingamotor
electrically“starved”bytheuseof
supplywireswhicharetoosmall.
GROUNDING


Improperlygrounded
electricalcomponents
areshockhazards.
Makesureallthecomponents
areproperlygroundedtoprevent
deathorseriousinjury.
Thisproductmustbegrounded.
Groundingreducestheris ofelectrical
shoc byprovidinganescapewire
fortheelectriccurrentifshortcircuit
occurs.Thisproductmustbeinstalled
andoperatedwithapowercordor
cablethathasagroundingwire.
MO ORHOOKUPANDS AR ER
INS ALLA ION
Branchcircuitprotectionmustbe
providedasspecifiedintheUnited
StatesNationalElectricalCode,Chapter
2,“WiringDesignandProtection.”
Article210,usingtheapplicablearticle
“ForMotorsandMotorControllers,”
(Article430,Table430-152).
IMPOR AN :Overloadprotection
isrequiredforallmotors.Certain
motorshavethisprotectionbuilt-in.
Todetermineifamotorhasbuilt-in
overloadprotection,refertotheframe
sizeonthemotornameplate.
MotorswithframesizeR56HZ,Y56Y
orL143Tincludebuilt-inoverload
protection.Noadditionalprotectionis
required.UseFigure3wiringdiagram.
Motorswithframesizes184T,215T,
254Tor284Tdonothavebuilt-in
overloadprotection.Amagnetic
starterisrequired.UseFigure4wiring
diagram.
Tochangetothealternatevoltage
onthreephasemotorswith230/460
ratings:
1. Rewiremotorperdataplateon
motororinstructionsheet.
2. Chec electricratingofmagnetic
starterandreplacethermal
overloadelementsormagnetic
starterasrequired.Thevoltageand
amperageratingsarelistedonthe
motornameplate.
DIREC IONOFRO A ION
NO E:Improperrotationwillresultin
reducedunitlife.
Thedirectionofrotationmustbe
countercloc wise(asshownbythe
arrowontheflywheel)whilefacing
theflywheelsideofthepump.The
motornameplatewillshowwiring
informationforcountercloc wise
rotation.
Theproperdirectionisvery
important.Thedirectionofrotation
of3phasemotorscanbereversed
byinterchanginganytwomotor-line
leads.Forsinglephasemotors,referto
themotornameplate.
OperatingInstructions
4
Chart2:MinimumWireSize
Use75°CCopperWire
Single
Phase
Three
Phase

HP

Amps

230V
208 
230V
460 
575V
SPL
Upto22.0
10
AWG
5.0 8
AWG
12
AWG
14
AWG
7.5 8
AWG
10
AWG
12
AWG
10.0 8
AWG
12
AWG
15.0 6
AWG
10
AWG
25.0 3
AWG
8
AWG
IsolationPad
(availableseparately)
Tan
Tan Shut-OffValve
(availableseparately)
FactoryMounted
MagneticStarter
(notonallunits)
Pump
Discharge
Tube
Motor
SafetyValve
Access
Figure2-HorizontalUnitIdentification
DrainValve
DischargePort
PressureSwitch
Pressure
Gauge
Chec 
Valve
All manuals and user guides at all-guides.com
Operation
IMPOR AN :Chec motorrotation
beforeoperatingthecompressor.
Alllubricatedcompressorpumps
dischargesomecondensedwater
andoilwiththecompressedair.
Installappropriatewater/oilremoval
equipmentandcontrolsasnecessaryfor
theintendedapplication.
 Failuretoinstall
 appropriatewater/
oilremovalequipmentmayresultin
damagetomachineryorworkpiece.
GUARDING
 The
 belt
guardprovidedmust
beinstalledbefore
operatingtheunit.
Allmovingpartsmustbeguarded.
Allelectricalcoversmustbeinstalled
beforeturningonthepower.
LUBRICA ION
 THIS NIT
 CONTAINSNOOIL.
Beforeoperatingcompressor,fill
crankcasewithcompressoroil
accordingtotheoilcapacitychart.
Someresidualoilmaystillbeinthe
pumpleavingathincoatonthesight
glass,however;thereisnotenough
oiltooperatetheunit.Fillpumpwith
single-viscosity,ISO100,non-detergent,
compressoroil.
UsepartnumberST126700AV,
compressoroilorMobil1®5W30or
10W30syntheticoilmayalsobeused.
Addoilonlythroughtheoilfillplug.
Pouringoilintoanyotherorificewill
causeoiltolea andsprayoutduring
operation.
F2101, F2111, Q3010, Q3011, X2101, X2118
5
L1 L2
T2T1
X2
T2
X2
L1 L2 L3
T3
T1
Filltothecenterofthesightgaugeor
maximummar ondipstic (see
Figure5).
 singanyother
 typeofoilmay
shortenpumplifeanddamage
valves.
Low
Max
Figure3-ForMotorFrameSizes
R56HZ,Y56YorL143 .
RefertoMotorNameplate
Motor
Ground
L3(for3phasewiringonly)
L2
L1
SinglePhase/ThreePhase
WiringDiagram
Figure4-ForMotorFrameSizes184 ,215 ,254 or284 .
RefertoMotorNameplate
SinglePhase
WiringDiagram
Motor
Circuit
Brea er
orFused
Disconnect
ThreePhase
WiringDiagram
Motor
Coil Coil
Circuit
Brea er
orFused
Disconnect
Over
Load
Over
Load
Thermal
Unit
Thermal
Units(3)
Figure5-OilFillDiagrams
Full
Low
SightGauge
OilFill
Plug
Breather
Cap Breather
Cap
OilFill
Plug
Oil
Drain
Plug
Fill
Line
OilDrain
Plug
Drainon
side
Dipstic and
OilFill
Drain
Dipstic and
OilFill
Pressure
Switch
Pressure
Switch
All manuals and user guides at all-guides.com
Operation(Continued)
RECOMMENDEDBREAK-INPERIOD
Thecompressorshouldberun
continuouslyforonehourtoallow
properseatingofthepistonrings.
1. Opendrainvalvecompletelyand
runthecompressorfor60minutes
(SeeFigure6).
2. Turnoffthecompressorandclose
drainvalve.Thecompressorisnow
readyforuse.
Ifthecompressorisrununderhumid
conditionsforshortperiodsoftime,the
humiditywillcondenseinthecran case
andcausetheoiltoloo creamy.Oil
contaminatedbycondensedwaterwill
notprovideadequatelubricationand
mustbechangedimmediately.Using
contaminatedoilwilldamagebearings,
pistons,cylindersandringsandisnot
coveredunderwarranty.Toavoidwater
condensationintheoil,periodically
runthecompressorwithtan pressure
near150psifortwo-stagecompressors
or120psiforsinglestagecompressors
byopeningthedrainvalveoranair
valveconnectedtothetan orhose.
Runthepumpforanhouratatimeat
leastonceawee ormoreoftenifthe
condensationreoccurs.
IMPOR AN :Changeoilafterfirst50
hoursofoperation.
PRESSURESWI CH,S AR -S OP
NO E:Thiscompressorhasamaximum
operatingpressureof175PSIfor
two-stagecompressorsor135PSI
forsinglestagecompressors.Donot
alterpressuresettingsoncontrol
componentsabovethislimit.
Thecompressorunitstartsandstops
basedonpresetpressureswitch
settings.Thepressureswitchcontains
anunloaderwhichisasmallvalvethat
ventsairtoallowthemotortostart
easily(SeeFigure7).
CON INUOUSRUNOPERA ION
Toconverttocontinuousrunoperation
aseparateunloadingdevicemustbe
installedbytheuserbetweenthepump
andthetan .Theexistingchec valve
mustberemoved.
CRANKCASEBREA HER
Duringsevereoperatingconditionsor
initialstart-up,someoilmayaccumulate
atthecran casebreatheropening.This
isnormalandwilldiminishasthepump
accumulatesruntimeandthepiston
ringsbecomefullyseated.
OperatingInstructions
6
Maintenance

 
Disconnect,tagandlock
outpowersourcethen
releaseallpressurefrom
thesystembeforeattemptingto
install,service,relocateorperform
anymaintenance.
Inordertomaintainefficientoperation
ofthecompressorsystem,chec the
airfilterandoillevelbeforeeachuse.
TheASMEsafetyvalveshouldalso
bechec eddaily(SeeFigure8).Pull
ringonsafetyvalveandallowthe
ringtosnapbac tonormalposition.
Thisvalveautomaticallyreleasesairif
thetan pressureexceedsthepreset
maximum.Ifairlea saftertheringhas
beenreleased,orthevalveisstuc and
cannotbeactuatedbythering,the
ASMEsafetyvalvemustbereplaced.
 Donotattemptto
 tamperwiththe
ASMEsafetyvalve.
ANK
 
 Never
attempttorepairor
modifyatank!Welding,
drillingoranyother
modificationwill
weakenthetankresultingin
damagefromruptureorexplosion.
Alwaysreplaceworn,crackedor
damagedtanks.
 Drainliquidfrom
 tankdaily.
Thetan shouldbecarefullyinspected
ataminimumofonceayear.Loo 
forcrac sformingnearthewelds.If
acrac isdetected,removepressure
fromtan immediatelyandreplace.
COMPRESSORLUBRICA ION
SeeOperation.Addoilasrequired.
Theoilshouldbechangedeverythree
monthsorafterevery500hoursof
operation;whichevercomesfirst.Only
pressurelubricatedpumpshaveanoil
filter.
Figure6-OpeningDrainValve
Figure7-PressureSwitch
Totan pressure
Unloader
Figure8
MOIS UREINCOMPRESSEDAIR
Moistureincompressedairwillform
intodropletsasitcomesfromanair
compressorpump.Whenhumidity
ishighorwhenacompressorisin
continuoususeforanextendedperiod
oftime,thismoisturewillcollectin
thetan .Whenusingapaintspray
orsandblastgun,thiswaterwillbe
carriedfromthetan throughthe
hose,andoutofthegunasdroplets
mixedwiththespraymaterial.
IMPOR AN :Thiscondensation
willcausewaterspotsinapaintjob,
especiallywhensprayingotherthan
waterbasedpaints.Ifsandblasting,it
willcausethesandtoca eandclog
thegun,renderingitineffective.A
filterintheairline,locatedasnearto
thegunaspossible,willhelpeliminate
thismoisture.
All manuals and user guides at all-guides.com
F2101, F2111, Q3010, Q3011, X2101, X2118
7
Maintenance(Continued)
AIRFIL ER
Neverrunthecompressorpump
withoutaninta eairfilternor
withacloggedinta eairfilter.Use
compressedairtoblowthefilterclean.
Donotwashoroiltheelement.Ifit
cannotbeblownclean,thefiltermust
bereplaced.Operatingcompressor
withadirtyfiltercancausehigh
oilconsumptionandincreaseoil
contaminationinthedischargeair.
IN ERCOOLER( WO-S AGE
COMPRESSORSONLY)
 Intercoolerfins
 aresharp,always
wearglovesandusecarewhenyou
cleanorworkneartheintercooler.
Wee ly,chec theintercoolertobesure
allfittingsaresecureandtight.Blowall
dirt,dustandotheraccumulationsfrom
theintercoolerfins.
COMPONEN S
Turnoffallpoweranduselightair
pressuretoblowdustandforeign
materialfromcylinderhead,motor,fan
blades,airlines,intercoolerandtan 
onamonthlybasis.
BEL S
 Lockoutandtag
 thepowerthen
releaseallpressurefromthetankto
preventunexpectedmovementofthe
unit.
Chec belttensionevery3months.
Adjustbelttensiontoallow3/8to1/2
inchdeflectionwithnormalthumb
pressure.Also,alignbeltsusinga
straightedgeagainstthefaceofthe
flywheelandtouchingtherimonboth
sidesoftheface.Thebeltsshouldbe
paralleltothisstraightedge(see
Figure9).DimensionAshouldbethe
sameasBandCtoensureproper
alignmentofthebelts.
Slotsinthebed-plateallowforsliding
themotorbac andforthtoadjustbelt
tension.
S ORAGE
Ifcompressoristobestoredforashort
periodoftime,ma esurethatitis
storedinanormalpositionandina
coolprotectedarea.
� B
C
AirCompressor
Motor
Flywheel
StraightEdge
Setscrew
Motor
Drive
Pulley
Figure9- opView
roubleshootingChart
Symptom PossibleCause(s) CorrectiveAction
Motorhumsand
runsslowlyornot
atall
1.Lowvoltageornovoltage 1.Chec withvoltmeter,chec overloadrelayinmagneticstarterorreset
switchonmotor.Ifoverloadorresetswitchtripsrepeatedly,findand
correctthecause.Seenextitem
2.Shortedoropenmotorwinding 2.Replacemotor
3.Malfunctioningchec valveor
unloadervalve
3.Replacechec valveorunloadervalve
4.Malfunctioningpressureswitch-
contactswillnotclose
4.Repairorreplacepressureswitch
Resetmechanism
cutsoutrepeatedly
orfusesblow
repeatedly
1.Pressureswitchsettoohigh 1.Adjustorreplace
2.Malfunctioningchec valve 2.Cleanorreplacefaultyvalve
3.Incorrectfusesizeormagnetic
starterheaters
3.Besurethatfusesandheatersareratedproperly
4.Malfunctioningmotor 4.Replacemotor
5.LooseWiring 5.Chec allelectricalconnections
MAIN ENANCESCHEDULE
Operation Daily Weekly Monthly 3Months
Chec SafetyValve �
DrainTan (SeeFigure6) �
Chec OilLevel �
CleanorChangeAirFilter �
Chec Intercooler(two-stage
compressorsonly) �
CleanUnitComponents �
Chec BeltTightness �
ChangeOil(SeeFigure5) �
ChangeOilFilter(Pressure
lubricatedpumpsonly) �
All manuals and user guides at all-guides.com
Excessivenoisein
operation
1.Loosepulley,flywheel,belt,belt
guard,etc
1.Tighten
2.Lac ofoilincran case 2.Chec fordamagetobearings,replenishoil
3.Compressorfloormountingloose 3.Shimtolevelandtightenorplaceonislolatorpads
4.Malfunctioningchec valve 4.Replacechec valve
5.Unitnotonvibrationpads 5.Installvibrationpadsundercompressorfeet
Mil yoilinoil
reservoir
Watercondensingincran casedue
tohighhumidity
Pipeairinta etolesshumidairsource.Runpump
continuouslyforonehour
Excessiveoil
consumptionoroil
inairlines
1.Besurethereisaproblem 1.Diagnoseoilcontaminationproblemsbytestingthedischargeairor
measuringoilconsumptionfromthecran case
2.Restrictedairinta e 2.Cleanorreplaceairfilter
3.Wrongoilviscosity 3.Drainoil.Refillwithoilofproperviscosity
4.Wornpistonrings 4.Replacerings
5.Oillea s 5.Tightenbolts,replacegas etsoro-rings
6.Scoredcylinder 6.Replacecylinder
Waterindischarge
air
1.Excessivewaterintan 1.Draintan
2.Hot,humidweather 2.Purchasedryer
Airblowingoutof
inlet
1.Bro enfirststageinletvalve(two-
stageunit)
1.Replacevalveassembly
2.Bro eninletvalve(singlestage
unit)
2.Replacevalveassembly
Insufficientpressure 1.Airdemandtoohigh 1.Limitairusage
2.Lea sorrestrictionsinhosesor
piping
2.Chec forlea sorrestrictioninhoseorpiping
3.Slippingbelts 3.Tightenbelts
Tan doesnothold
pressurewhen
compressorisoff
andshutoffvalveis
closed
1.Wornchec valve 1.Replacechec valve
 Donotdisassemblecheckvalvewithair
 intank
2.Chec allconnectionsandfittings
fortightness
2.Tighten
3.Chec tan forcrac sorpinholes 3.Replacetan .Neverrepairadamagedtan
Excessivebeltwear.
(Lightdustfrom
startisnormal.
Wornbeltsseparate
atlayers)
1.Pulleyoutofalignment 1.Realignmotorpulley
2.Beltstootightortooloose 2.Adjusttension
Tan pressurebuilds
slowly
1.Dirtyairfilter 1.Cleanorreplacefilterelement
2.Blowncylinderheadgas et 2.Installnewgas et
3.Worn/bro eninta e/discharge
valves
3.Installnewvalveplateassembly
4.Airlea s 4.Tightenjoints
Tan pressure
buildsupquic lyon
compressor
Excessivewaterintan Draintan ,chec speed.SeePerformancetable
ASMEsafetyvalve
popsopenwhile
compressoris
running
1.Wrongpressureswitchsetting 1.Adjusttolowerpressure(175psimaximumfortwo-stageunitor
135psiforsinglestageunit)(SeeOperation)
2.MalfunctioningASMEsafetyvalve 2.ReplaceASMEsafetyvalve
3.Pressureswitchcontactswelded 3.Replacepressureswitch
Pressureswitch
continuouslyblows
airouttheunloader
valve
Malfunctioningchec valve Replacethechec valveiftheunloadervalvebleedsoffconstantly
Pressureswitch
unloadervalvedoes
notreleaseairwhen
theunitshutsoff
Malfunctioningunloadervalveon
pressureswitch
Replacethepressureswitchiftheunitdoesnothissforashortperiod
oftimewhentheunitshutsoff
Interstagesafety
valvepopsoffwhile
theunitisrunning
1.Headgas etorthegas etinthe
valveplateassemblyblown
1.Replacevalveplateandgas ets
2.Valvenotseatingproperly 2.Replacevalveplateandgas ets
3.Malfunctioningsafetyvalve 3.Replacesafetyvalve
Interstagesafety
valvepopsoffafter
theunitshutsoff
Malfunctioningtan chec valve Replacethechec valve
OperatingInstructions
8
roubleshootingChart(Continued)
Symptom PossibleCause(s) CorrectiveAction
All manuals and user guides at all-guides.com
F2101, F2111, Q3010, Q3011, X2101, X2118
9
ServiceRecord
Date MaintenancePerformed ReplacementComponentsRequired
All manuals and user guides at all-guides.com
LimitedWarranty
1. DURATION:Fromthedateofpurchasebytheoriginalpurchaserasfollows:OneYearasindicatedonproductspecification
label.
2. WHOGIVESTHISWARRANTY(WARRANTOR):CampbellHausfeld/ScottFetzerCompany,100ProductionDrive,
Harrison,Ohio,45030,Telephone:(800)543-6400
3. WHORECEIVESTHISWARRANTY(PURCHASER):Theoriginalpurchaser(otherthanforpurposesofresale)oftheCampbell
Hausfeldcompressor.
4. WHATPRODUCTSARECOVEREDBYTHISWARRANTY:ThisCampbellHausfeldaircompressor.
5. WHATISCOVEREDUNDERTHISWARRANTY:PartsandLabortoremedysubstantialdefectsduetomaterialand
wor manshipduringthefirstyearofownershipwiththeexceptionsnotedbelow.Partsonlytoremedysubstantialdefects
duetomaterialandwor manshipduringremainingtermofcoveragewithexceptionsnotedbelow.
6. WHATISNOTCOVEREDUNDERTHISWARRANTY:
A.Impliedwarranties,includingthoseofmerchantabilityandFITNESSFORAPARTICULARPURPOSEARELIMITEDFROM
THEDATEOFORIGINALPURCHASEASSTATEDINTHEDURATION.Ifthecompressorisusedforcommercial,industrial
orrentalpurposes,thewarrantywillapplyforninety(90)daysfromthedateofpurchase.Two-stagecompressorsare
notlimitedtoaninety(90)daywarrantywhenusedincommercialorindustrialapplications.SomeStatesdonotallow
limitationsonhowlonganimpliedwarrantylasts,sotheabovelimitationsmaynotapplytoyou
B. ANYINCIDENTAL,INDIRECT,ORCONSEQUENTIALLOSS,DAMAGE,OREXPENSETHATMAYRESULTFROMANYDEFECT,
FAILURE,ORMALFUNCTIONOFTHECAMPBELLHAUSFELDPRODUCT.SomeStatesdonotallowtheexclusionor
limitationsofincidentalorconsequentialdamages,sotheabovelimitationorexclusionmaynotapplytoyou.
C. Anyfailurethatresultsfromanaccident,purchaser’sabuse,neglectorfailuretooperateproductsinaccordancewith
instructionsprovidedintheowner’smanual(s)suppliedwithcompressor.
D.Pre-deliveryservice,e.g.assembly,oilorlubricants,andadjustment.
E. Itemsorservicethatisnormallyrequiredtomaintaintheproduct,e.g.lubricants,filtersandgas ets,etc.
F. Gasolineenginesandcomponentsareexpresslyexcludedfromcoverageunderthislimitedwarranty.ThePurchaser
mustcomplywiththewarrantygivenbytheenginemanufacturerwhichissuppliedwiththeproduct
G.Additionalitemsnotcoveredunderthiswarranty:
1.ExcludeditemspertainingtoAllCompressors
 a.Anycomponentdamagedinshipmentoranyfailurecausedbyinstallingoroperatingunitunderconditionsnot
 inaccordancewithinstallationandoperationguidelinesordamagedbycontactwithtoolsorsurroundings.
 b.Pumporvalvefailurecausedbyrain,excessivehumidity,corrosiveenvironmentsorothercontaminants.
 c.Cosmeticdefectsthatdonotinterferewithcompressorfunctionality.
 d.Thefollowingcomponentsareconsiderednormalwearitemsandarenotcoveredafterthefirstyearof
 ownership.Electricmotor,chec valve,pressureswitch,regulator,pressuregauges,hose,tubing,pipe,fittings
 andcouplers,screws,nuts,hardwareitems,belts,pulleys,flywheel,airfilterandhousing,gas ets,seals,oillea s,
 airlea s,oilconsumptionorusage,pistonrings.
 e.Damageduetoincorrectvoltageorimproperwiring.
 f. Otheritemsnotlistedbutconsideredgeneralwearparts.
 g.Pressureswitches,airgovernors,load/unloaddevices,throttlecontroldevicesandsafetyvalvesmodifiedfrom
 factorysettings.
 h.Damagefrominadequatefiltermaintenance.
2.ExcludeditemsspecifictoLubricatedCompressors:
 a.Pumpwearorvalvedamagecausedbyusingoilnotspecified.
 b.Pumpwearordamagecausedbyanyoilcontamination.
 c.Pumpwearordamagecausedbyfailuretofollowproperoilmaintenanceguidelines,operationbelowproperoil
 leveloroperationwithoutoil.
H.Labor,servicecall,ortransportationchargesafterthefirstyearofownershipofstationarycompressors.Stationary
compressorsaredefinedasnotincludingahandleorwheels.
7. RESPONSIBILITIESOFWARRANTORUNDERTHISWARRANTY:Repairorreplace,atWarrantor’soption,compressoror
componentwhichisdefective,hasmalfunctionedand/orfailedtoconformwithinthedurationofthespecificwarranty
period.
8. RESPONSIBILITIESOFPURCHASERUNDERTHISWARRANTY:
A.Providedatedproofofpurchaseandmaintenancerecords.
B. CallCampbellHausfeld(800-543-6400)toobtainyourwarrantyserviceoptions.Freightcostsmustbebornebythe
purchaser.
C. Usereasonablecareintheoperationandmaintenanceoftheproductsasdescribedintheowner’smanual(s).
D.Repairsrequiringovertime,wee endrates,oranythingbeyondthestandardmanufacturerwarrantyrepairlabor
reimbursementrate.
E. Timerequiredforanysecuritychec s,safetytraining,orsimilarforservicepersonneltogainaccesstofacility.
F. Locationofunitmusthaveadequateclearanceforservicepersonneltoperformrepairsandeasilyaccessible.
9. WHENWARRANTORWILLPERFORMREPAIRORREPLACEMENTUNDERTHISWARRANTY:Repairorreplacementwillbe
scheduledandservicedaccordingtothenormalwor flowattheservicinglocation,anddependingontheavailabilityof
replacementparts.
ThisLimitedWarrantyappliesintheU.S.,CanadaandMexicoonlyandgivesyouspecificlegalrights.Youmayalsohave
otherrightswhichvaryfromStatetoStateorcountrytocountry.
OperatingInstructions
10
All manuals and user guides at all-guides.com

This manual suits for next models

5

Other Campbell Hausfeld Air Compressor manuals

Campbell Hausfeld CE3000 User manual

Campbell Hausfeld

Campbell Hausfeld CE3000 User manual

Campbell Hausfeld TF2101 User manual

Campbell Hausfeld

Campbell Hausfeld TF2101 User manual

Campbell Hausfeld WL6000 series User manual

Campbell Hausfeld

Campbell Hausfeld WL6000 series User manual

Campbell Hausfeld Portable Air Compressor User manual

Campbell Hausfeld

Campbell Hausfeld Portable Air Compressor User manual

Campbell Hausfeld FP2004 User manual

Campbell Hausfeld

Campbell Hausfeld FP2004 User manual

Campbell Hausfeld DC040500 Service manual

Campbell Hausfeld

Campbell Hausfeld DC040500 Service manual

Campbell Hausfeld Oilless Compressors FP209002L Service manual

Campbell Hausfeld

Campbell Hausfeld Oilless Compressors FP209002L Service manual

Campbell Hausfeld DC1300 Service manual

Campbell Hausfeld

Campbell Hausfeld DC1300 Service manual

Campbell Hausfeld HU3501 User manual

Campbell Hausfeld

Campbell Hausfeld HU3501 User manual

Campbell Hausfeld HL540210 Use and care manual

Campbell Hausfeld

Campbell Hausfeld HL540210 Use and care manual

Campbell Hausfeld HL300000 Application guide

Campbell Hausfeld

Campbell Hausfeld HL300000 Application guide

Campbell Hausfeld HS581600AJ Application guide

Campbell Hausfeld

Campbell Hausfeld HS581600AJ Application guide

Campbell Hausfeld DC200100 Service manual

Campbell Hausfeld

Campbell Hausfeld DC200100 Service manual

Campbell Hausfeld Extreme Contractor Series User manual

Campbell Hausfeld

Campbell Hausfeld Extreme Contractor Series User manual

Campbell Hausfeld RP3300 Quick start guide

Campbell Hausfeld

Campbell Hausfeld RP3300 Quick start guide

Campbell Hausfeld HG3000 Series Manual

Campbell Hausfeld

Campbell Hausfeld HG3000 Series Manual

Campbell Hausfeld WL6700 Series Quick start guide

Campbell Hausfeld

Campbell Hausfeld WL6700 Series Quick start guide

Campbell Hausfeld FP204100 Service manual

Campbell Hausfeld

Campbell Hausfeld FP204100 Service manual

Campbell Hausfeld EX8000Series User manual

Campbell Hausfeld

Campbell Hausfeld EX8000Series User manual

Campbell Hausfeld FP204020 Service manual

Campbell Hausfeld

Campbell Hausfeld FP204020 Service manual

Campbell Hausfeld DC03009 Service manual

Campbell Hausfeld

Campbell Hausfeld DC03009 Service manual

Campbell Hausfeld HL551600 Manual

Campbell Hausfeld

Campbell Hausfeld HL551600 Manual

Campbell Hausfeld Oilless Compressors FP209002 Manual

Campbell Hausfeld

Campbell Hausfeld Oilless Compressors FP209002 Manual

Campbell Hausfeld FP209699 Service manual

Campbell Hausfeld

Campbell Hausfeld FP209699 Service manual

Popular Air Compressor manuals by other brands

AMiO ST-07 user manual

AMiO

AMiO ST-07 user manual

Draper DA200 instructions

Draper

Draper DA200 instructions

KICK ASS KAJSCOMP user manual

KICK ASS

KICK ASS KAJSCOMP user manual

Central Pneumatic 95630 Set up and operating instructions

Central Pneumatic

Central Pneumatic 95630 Set up and operating instructions

Emax HULK POWER HP15P004SS operating instructions

Emax

Emax HULK POWER HP15P004SS operating instructions

pilotair Hobby Series user guide

pilotair

pilotair Hobby Series user guide

Airmax ProAir 4 installation instructions

Airmax

Airmax ProAir 4 installation instructions

CO/Tech ZB-0.07/8-XA4832-uk Original instructions

CO/Tech

CO/Tech ZB-0.07/8-XA4832-uk Original instructions

Central Pneumatic 67696 Set up and operating instructions

Central Pneumatic

Central Pneumatic 67696 Set up and operating instructions

Delta (66-501-1) instruction manual

Delta

Delta (66-501-1) instruction manual

Power Fist 8132938 owner's manual

Power Fist

Power Fist 8132938 owner's manual

pilotair K17T Instructions and parts list

pilotair

pilotair K17T Instructions and parts list

BOSSCO RCL-10 owner's manual

BOSSCO

BOSSCO RCL-10 owner's manual

Green Power GPAC2506H owner's manual

Green Power

Green Power GPAC2506H owner's manual

Craftsman 919.167242 owner's manual

Craftsman

Craftsman 919.167242 owner's manual

Trudell Medical International OMBRA Instructions for use

Trudell Medical International

Trudell Medical International OMBRA Instructions for use

Roll Music Systems RMS755 SUPER STEREO user manual

Roll Music Systems

Roll Music Systems RMS755 SUPER STEREO user manual

Beko BEKOMAT 20 Instructions for installation and operation

Beko

Beko BEKOMAT 20 Instructions for installation and operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.