Campomatic AC12MS User manual

CS525-U
202000192060
20100716
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
SPLIT TYPE
ROOM AIR CONDITIONER
-
Read This Manual
Inside you will find many helpful hints on how
to use and maintain your air conditioner properly.
Just a little preventative care on your part can
save you a great deal of time and money over
the life of your air conditioner. You'll find many
answers to common problems in the chart of
troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need
to call for service.
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.

1 2
CONTENTS
Contact an authorised service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit.
The air conditioner is not intended for use by young children or invalids
without supervision.
Young children should be supervised to ensure that they do not play with the
air conditioner.
If the power cord is to be replaced, replacement work shall be performed by
authorised personnel only.
Installation work must be performed in accordance with the national wiring
standards by authorised personnel only.
!CAUTION
SOCIABLE REMARK
Sociable remark......................................................................................................................2
SAFETY PRECAUTIONS
Warning .................................................................................................................................3
Caution ..................................................................................................................................4
OPERATING INSTRUCTIONS
Parts names ........... .............................................................................................................5
Operating temperature...........................................................................................................6
Manual operation ..................................................................................................................6
Airflow direction control .........................................................................................................7
How the air conditioner works ...............................................................................................8
CARE AND MAINTENANCE
Care and maintenance ...........................................................................................................9
TROUBLESHOOTING TIPS
Troubleshooting tips .............................................................................................................13
OPERATION TIPS
Operation tips ............ ..........................................................................................................11
SOCIABLE REMARK
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:
A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least
free of charge.
C) The manufacture will take back the old appliance for disposal at least free of
charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal
dealers.
Wild disposal of waste in forests and landscapes endangers your health when
hazardous substances leak into the ground-water and find their way into the food
chain.
When using this air conditioner in the European countries, the follow
informations must be followed:

3 4
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The
seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
WARNING
Always do this.
Never do this.
CAUTION
This symbol indicates the possibility of injury or damage to property.
Connect with the power
properly.
Do not modify power cord
length or share the outlet
with other appliances
Always ensure effective
earthing.
Disconnect the power if
strange sounds, smell, or
smoke comes from it.
Ventilate room before operating air
conditioner if there is a gas leakage from
another appliance.
Otherwise, it may cause electric
shock or fire due to heat
generation.
excess
It may cause electric shock or
fire due to heat generation.
No earthing may cause electric
shock.
It may cause fire and electric
shock.
It may cause explosion, fire and, burns.
It may cause electric shock or fire
due to heat generation.
It may cause electric shock.
It may cause failure of machine
or electric shock.
It contains contaminants and
could make you sick.
It may cause fire and electric
shock.
It may cause electric shock or fire.
This could damage your health.
No installation may cause fire
and electric shock.
It may cause electric shock.
It may cause an explosion or fire.
It may cause failure and electric shock.
Do not operate or stop the
unit by switching on or off
the power.
Do not operate with wet
hands or in damp
environment.
Do not allow water to run
into electric parts.
Do not drink water drained
from air conditioner.
Do not use the power cord
close to heating appliances.
Do not damage or use an
unspecified power cord.
Do not direct airflow at
room occupants only.
Always install circuit
breaker and a dedicated
power circuit.
Do not open the unit
during operation.
Do not use the power cord near
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
Do not disassemble or modify unit.
!
!
!
!
!
WARNING
Use the correctly rated
breaker or fuse.
There is risk of fire or electric
shock.
!
SAFETY PRECAUTIONS
CAUTION
When the air filter is to be
removed, do not touch the
metal parts of the unit.
It may cause an injury.
Do not clean unit when
power is on as it may cause
fire and electric shock, it may
cause an injury.
Operation with windows
opened may cause wetting
of indoor and soaking of
household furniture.
When the unit is to be
cleaned, switch off, and turn
off the circuit breaker.
Stop operation and close
the window in storm or
hurricane.
Use caution when unpacking
and installing. Sharp edges
could cause injury.
Do not clean the air
conditioner with water.
Water may enter the unit and
degrade the insulation. It may
cause an electric shock.
This could injure the pet or
plant.
Do not put a pet or house
plant where it will be
exposed to direct air flow.
Ventilate the room well
when used together
with a stove, etc.
An oxygen shortage
may occur.
Do not use this air cond-
itioner to preserve preci-
sion devices, food, pets,
plants, and art objects.
It may cause deterioration
of quality, etc.
It may cause failure of
product or fire.
Do not use for
special purposes.
Turn off the main power
switch when not sing
the unit for a long time.
u
If water enters the
unit, turn the unit off
and disconnect the
power , contact a
qualified service
technician.
!
!
!
!
!
!
!
It may cause failure of
appliance or accident.
Appearance may be
deteriorated due to change
of product color or
scratching of its surface.
Do not place obstacles
around air-inlets or inside
of air-outlet.
Do not use strong detergent
such as wax or thinner. Use
a soft cloth for cleaning.
If bracket is damaged, there
is concern of damage due to
falling of unit.
There is danger of fire or
electric shock.
Ensure that the installation bracket of
the outdoor appliance is not damaged
due to prolonged exposure.
Do not place heavy object on the
power cord and take care so that
the cord is not compressed.
Operation without filters
may cause failure.
Always insert the filters
securely. Clean filter
once every two weeks.
!
!
!

5 6
Parts names
Outdoor unit
OPERATING INSTRUCTIONS
Indoor unit
NOTE:
All the pictures in this manual are for
explanation purpose only. Your air
conditioner may be slightly different.
The actual shape shall prevail.
4
3
5
2
6
1
8
10
11
9
7
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5.
6.
7. Display panel
8. Remote controller
Horizontal air flow grille
Vertical air flow louver
9. Connecting pipe, drain hose
10. Air inlet (side and rear)
11. Air outlet
Indoor unit
Outdoor unit
Indicator Lights on Display panel
The display panel on the indoor unit
would look like one of the following:
AUTO indicator:
DEFROST Indicator
DIGITAL DISPLAY:
indicator:
TIMER indicator:
This indicator illuminates when the air
conditioner is in AUTO operation.
This indicator illuminates when the air
conditioner starts defrosting automatically
or when the warm air control feature is
activated in heating operation.
Displays the current setting temperature
when the air conditioner is in operation.
The indicator flashes once every second
after power is on and illuminates when the
air conditioner is in operation.
The indicator illuminates when TIMER is
set ON/OFF.
(For cooling& heating model only):
OPERATION
1
2
3
4
5
11
Signal
receptor
(C
)
。
TEMP
AUTO
COOL
DRY
HEAT
FAN
HIGH
MED
LOW
MODE FANSPEED
TIMERON
SLEEP
ON/OFF
TIMEROFF
AIR
DIRECTION
RESETLOCK
SETTEMPERATURE
SWING
LED
DISPLAYTURBO
auto
2 3 45
Manul operation can be used temporarily in case the remote controller is disable or
maintenance necessary.
OPERATING INSTRUCTIONS
Manual operation
Manual control
button
Panel
AUTO/COOL
NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.
Operating temperature
Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
Push the button until the AUTO indicator
is lit, the unit will work in forced AUTO
mode (the default setting temperature
is 24 ).
Close the panel firmly to its original
position.
℃
Once you push the manual button, the
operation mode is shifted in an order as:
AUTO, COOL, OFF.
This is used for testing purposes only.
To restore the remote controller operation,
use the remote controller directly.
CAUTION:
1
3
2
●
●
●
Mode
Cooling operation
Heating operation
Drying operation
Temperature
1. If air conditioner is used outside of the above conditions, certain safety protection features may
come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the
surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
Room temperature
Outdoor temperature
17 C 32 C
。。
18 C 43 C
。。
0C 30C
-7 C 24 C
。。
。。
11 C~43 C
OO
(<21000Btu/h models)
10 C~32 C
OO
(<21000Btu/h models)
17 C~32 C
OO
(>21000Btu/h models)
18 C~43 C
OO
(>21000Btu/h models)
~~
~
( -5 C 43 C:For the models with
low temperature cooling system)
。。
~
~
(21 C 52 C:For special tropical
models
。。
~
21 C 52 C
(For special tropical models)
。。
~
NOTE:

7 8
OPERATING INSTRUCTIONS
Airflow direction control
Range
Range
To achieve optimal performance, please note the following:
Adjust the air flow direction correctly so that it is not directed
on people.
Adjust the temperature to achieve the highest comfort level.
Do not adjust the unit to excessive temperature levels.
Close doors and windows on COOL or HEAT modes, or
performance may be reduced.
Use TIMER ON button on the remote controller to select a
time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the
efficiency of the air conditioner may be reduced and the air
conditioner may stop running.
Clean the air filter periodically, otherwise cooling or heating
performance may be reduced.
Do not operate unit with horizontal louvre in closed position.
OPERATING INSTRUCTIONS
How the air conditioner works
Optimal operation
1 hour
1 hour
Set
Temperature
Cooling
1℃
1℃
Heating
SLEEP operation
1℃
1℃
1 hour 1 hour
Set
Temperature
SLEEP operation
7 hours timer off
7 hours timer off
AUTO operation
SLEEP operation
DRYING operation
When you set the air conditioner in AUTO mode, it will
automatically select cooling, heating(cooling/heating
models only), or fan only operation depending on what
temperature you have selected and the room temperature.
The air conditioner will control room temperature
automatically round the temperature point set by you.
If the AUTO mode is uncomfortable, you can select
desired conditions manually.
When you push SLEEP button on remote controller during
cooling, heating(cooling only type without), or AUTO
operation , the air conditioner will automatically increase
(cooling) or decrease (heating) 1 per hour for the first 2
hours, then hold steady for the next 5 hours, after that it
will switch off. This characteristic maintains both enery
saving and comfort in night operation.
The temperature is regulated while dehumidifying by
repeating turning on and off of the cooling operation or
fan only. The fan speed is LOW.
℃
Vertical
louver
(three places)
Adjust the air flow direction properly otherwise, it
might cause discomfort or cause uneven room
temperatures.
Adjust the horizontal louver using the remote
controller.
Adjust the vertical louver manually.
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow
direction. The horizontal louver can be moved at
a range of 6 for each press, or swing up and down
automatically. Please refer to the REMOTE
CONTROLLER OPERATION MANUAL for details.
To set the vertical air flow(Up--Down) direction
O
Move the vertical louver manually to adjust the air flow
in the direction you prefer.
: Before adjusting the vertical louvers, the
supply power must be disconnected.
For some models, the vertical louver can be adjusted
by using the remote controller. Please refer to the
REMOTE CONTROLLER OPERATION MANUAL
for details.
To set the horizontal air flow direction (left - right)
IMPORTANT
Do not operate the air conditioner for long periods the
air flow direction set downward in cooling or dehumidifying
mode.
Otherwise, may occur on the surface of the
horizontal louver causing moisture to drop on to the floor or
on furnishings.
Do not move the horizontal louver manually unless it is
necessary. Always use the remote controller.
When the air conditioner is started immediately after it was
stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set too
small, as COOLING or HEATING performance may be
impaired due to too restricted air flow area.
Do not operate unit with horizontal louver in closed position.
When the air conditioner is connected to power (initial
power), the horizontal louver may generate a sound for 10
seconds, this is a normal operation.
with
condensation
CAUTION
!
,,
,,
,,
,,
Table of contents
Other Campomatic Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual