manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Capella
  6. •
  7. Ventilation Hood
  8. •
  9. Capella Storce 60 User manual

Capella Storce 60 User manual

This manual suits for next models

1

Other Capella Ventilation Hood manuals

Capella capella User manual

Capella

Capella capella User manual

Capella CIELO User manual

Capella

Capella CIELO User manual

Popular Ventilation Hood manuals by other brands

Gorenje S3 IHGC963S4X manual

Gorenje

Gorenje S3 IHGC963S4X manual

KOBE ISX2136SQB-1 Installation instructions and operation manual

KOBE

KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products ADVANTAGE-100H Information & operating instructions

U.S. Products

U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg DUDL 4 LX Technical Passport

Kuppersberg

Kuppersberg DUDL 4 LX Technical Passport

Framtid HW280 manual

Framtid

Framtid HW280 manual

Thermador HGEW 36 FS installation manual

Thermador

Thermador HGEW 36 FS installation manual

Electrolux LFT769X user manual

Electrolux

Electrolux LFT769X user manual

AEG X69453MVO UK user manual

AEG

AEG X69453MVO UK user manual

Broan B5836SS manual

Broan

Broan B5836SS manual

Heinner HDCH-6060RGBK quick start guide

Heinner

Heinner HDCH-6060RGBK quick start guide

Baumatic AS35SS instruction manual

Baumatic

Baumatic AS35SS instruction manual

Franke FTF 604 XS V2 Instructions for use and installation

Franke

Franke FTF 604 XS V2 Instructions for use and installation

Best UCB3I30SBW installation instructions

Best

Best UCB3I30SBW installation instructions

Gram EFU 503-90 X instruction manual

Gram

Gram EFU 503-90 X instruction manual

CIARRA CBCS6803 Installation and user manual

CIARRA

CIARRA CBCS6803 Installation and user manual

sauter SHG501 Instructions for installation and use

sauter

sauter SHG501 Instructions for installation and use

Franke 392-17 User instructions

Franke

Franke 392-17 User instructions

FALMEC Polar Black 35 Instruction booklet

FALMEC

FALMEC Polar Black 35 Instruction booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

STRAIGHT LINE CHIMNEY
USER’S GUIDE
LIFETIMELIFETIMELIFETIME
WARRANTYWARRANTYWARRANTY
with
The warranty doesn't include the regular servicing of the product.
Parts covered under warranty are motor, switch and controls only. Models using Touch Controls or
Electronic Controls the warranty will be restricted to one year only.
Glass or Glass products are not covered under warranty.
The company will not accept any liability for any loss or damages of whatsoever nature on account of
fire, storm, theft, malicious damage, pressure cooker bursting or any other unforeseen acts or incidents.
Any damage done by rats or rodents etc. will not be covered by the warranty.
Glen Appliances Pvt. Ltd. accepts no liability for any consequential loss and / or damages caused to the
user or any third party due to any failure / malfunction of the product. The company's liability is limited
to the repair or replacement of the defective part.
In case of installation beyond the municipal limits of the areas of operation of authorised service centres,
or in areas where there are no service centres, the expenses incurred in transporting the parts / machine
including loading / unloading will be borne by the user and paid in advance.
The warranty will be valid only at the original place of purchase and in case of transfer the Chimney
should have been un-installed and then re-installed only by the authorized technician. No claims would
be entertained in cases of ownership changes.
The decision of Glen Appliances Pvt. Ltd. in respect of all claims in this regard would be final and
binding. All disputes subject to Faridabad jurisdiction.
Glen Appliances Pvt. Ltd. guarantees to get the product or any part thereof repaired free of charge for a
period of one year from the date of purchase, should any defect develop due to faulty or defective
workmanship or material. However, the glass, plastic breakable parts, lamps, push buttons, filter locks, and
items subject to normal wear and tear due to operation are not covered under guarantee.
Terms to Guarantee
* The Bill/Cash Memo should be presented.
* No repair work should be carried out by any unauthorised person.
* Product should be used as per the directions given in the user’s guide.
* Any defects caused by improper or reckless use are not covered under guarantee.
* The Serial No. Has not been tampered with.
* No modification/alteration of any nature is made in the Product.
The company accepts no responsibility for any consequential losses arising out of misuse or negligence on
the part of the user.
GUARANTEE
PACKING LIST
MAIN UNIT, SPIGOT, PLASTIC WALL PLUGS, SCREWS, USER’S GUIDE
PRODUCT
SERIAL NO : MODEL:
BILL NO. & DATE :
NAME OF OWNER :
ADDRESS :
DEALER'S STAMP & SIGNATURE
Glen Appliances Pvt. Ltd.
I-34, D.L.F. Industrial Area, Phase I, Faridabad,
Haryana - 121 003
Helpline: 0129-2254191
Email : [email protected] www.capellaindia.com
Marketed by :
The specifications of this Chimney will be based on the model selected by you identified with various features
as given in the below mentioned table:
Based on the features as mentioned in the model you have selected the specifications will be different. Please
note as improvements are a continuous process specifications are subject to change.
TECHNICAL SPECIFICATIONS
3
3Slider/Push Button
BF
BF
60
Storce 60
Duce 60
700 145 x 2
145 x 2
40 x 2
40 x 2
FRP
FRP
Speeds Control Filter Size
(cms)
Models Airflow
(m³/hr)
Motor
Power (w) Light Housing
700
Slider/Push Button
60
LIFETIME WARRANTY (On select models only)
To avail the lifetime warranty you need to register online within 90 days of your purchase.
To register online you need to do the following:
Log on to glen website www.capellaindia.com
Click on lifetime warranty, it will open a window there you need to feed the Lifetime Warranty unique ID,
model number and serial number of the chimney hood.
For LTW unique ID and serial number you need to open the chimney hood. You will find two labels one for
LTW unique ID and other for serial number. (Never ever remove the labels otherwise the warranty becomes void).
If all your information is correct and matches with our record another window will open wherein you will
need to fill the personal details like name & address etc.
Once you complete the information and press submit a confirmation number will be given for future
reference. Also one confirmation mail with all the details will be sent to your email id. You are requested to
take a printout of the same and keep it safe. In case of any repair in future you will need to show this mail to
the service engineer to avail the lifetime warranty.
Note : The offer lapses if not registered with in 90 days of date of purchase.
The chimney should be used as per the directions given in the user's guide. Defects caused by improper
or reckless use are not covered.
Any damages due to the use of abrasive chemicals, or usage in extremely adverse atmosphere, i.e.
abnormally corrosive / alkaline / acidic is not covered under warranty.
The warranty will not cover Chimneys used for commercial purposes.
The chimney should have been serviced and cleaned at regular intervals at-least once in two months by
a Glen Authorised Service Centre failure to comply with this will render this warranty void. The cost of
any such service will be borne by the customer.
No installation / modification / alteration / service of any nature is made in the chimney by unauthorised
persons. The Installation Charges are to be borne by the customer.
Only the parts covered under LTW will be replaced free. The labour charges for the replacement of under
warranty parts will be borne by the customer. The visit charges (within municipal area only) of Rs. 250/-
(subject to change from time to time) will be charged extra.
This chimney has been designed to last a long time and depending on the up-keep & maintenance by the
customer the Chimney may last a long time but for the purpose of Life Time Warranty the Life of the
Chimney will be taken as 7 years from the date of Purchase of the Chimney.
The warranty is not valid for any damages arising due to erratic power supply.
The warranty is not valid in case chimney is used on Inverter or Generator.
The Life Time Warranty is offered on the following conditions:
Switch on the chimney 5 minutes before you start cooking. Before
using the chimney please ensure that all plastic films on the filter and
stainless steel body are removed.
The push button/slider control have three speed settings. Kindly
choose the speed as per your requirement.
Two lamps are provided in the chimney to enable proper lighting up of the cooking area. The light works
independently of whether the fan is switched on or off, as it is provided with separate on/off switch.
Light
INSTALLATION
The chimney must be mounted over the center of the cooking area. The minimum
distance between the cooktop and the bottom of the chimney must be 750 mm.
If there is no outer waste-pipe for the exhaust, an air outlet with a diameter of
130 mm must be made through the wall. The exhaust pipe from the top of the
chimney, should be connected to the exhaust.
Fastening the chimney to the wall
Mark the position of the holes on the wall. Before drilling make sure that no
wiring and tube will be damaged. Drill two fastening holes, drive in the wall
plugs and screw in the screw until their heads are about 6 mm from wall.
Place the chimney to the wall in order to check that it seats properly. Then mark the position of the two
holes. Take it off from the wall now, drill the holes and fit the plugs.
Place the hood once again to the wall, and introduce the screws from the inside of the appliance.
The product can be used in re-circulation or the exhaust mode. It is however
recommended that wherever possible it should be used in exhaust mode for
best results.
Your chimney is provided with option of ducting from back or top depending on
the site. Before installation in case of air exhaust from back remove the cover
from back and fix it to top air outlet. now take the spigot and fit in the back air
outlet.
750 mm
750 mm
MAINTENANCE
When performing maintenance operations, disconnect the plug from the
socket.
The efficiency of the chimney depends on the condition of the filters.
The filters should be washed as often as possible but at least once in10 to 15
days in normal operating conditions.
The baffle & aluminium filters can be removed easily by unlocking.
Dip the filter for 10-15 minutes into a boiling hot soap solution and then wash in
running water. Dry and reinstall the filter.
The chimney surface should be cleaned with a damp cloth. No abrasive chemicals should be used.
Frequent cleaning of filter is very important to avoid danger of fire.
DO’S & DON'T’S
No flame based cooking should be done below the chimney.
While frying do not leave the cooking oil unattended as it may flare up and cause fire.
Clean all the oily residues on surface frequently to avoid fire.
The minimum distance between the cooktop and the bottom of the chimney must be 750 mm.
Make sure that the supply voltage ratings correspond with the specifications provided in the User’s
Guide.
Before using the chimney for the first time please ensure that all plastic films on baffle filter and stainless
body are removed.
Wash the filters as often as possible at least once in 10-15 days in normal operating conditions.
When performing maintenance operations, disconnect the plug from the socket.
No repair work should be carried out by any unauthorised person.
Chimney should be used as per the directions given in the User’s Guide.
Do not allow children to operate the chimney.
In case the chimney is installed in the under construction Kitchens, it is advisable to install the
Chimney, test it and then again remove the same and pack in the box. As if the Chimney is left
unattended the paints, chemicals, dust & moisture etc if not cleaned timely may result in rust formation
which will not be covered in the warranty.
Exhaust mode
Re-circulation mode (Available in select model)
This mode is used when no exhaust duct to the outdoors is available. The air is purified by an active carbon
filter and recycled into the room.
The carbon filter is an optional attachment and must be procured in this case.
Remove the metal filters. Insert the carbon filters and rotate it to lock at the side of the hood. For effective
functioning the carbon filters need to be replaced after 3-4 months.
Electric connection
Make sure that the supply voltage rating correspond with the specifications provided In the User’s Guide.
The chimney must be connected by the spigot (supplied as part of the hood) to a duct to vent all the
exhausted air outside the kitchen. Over horizontal areas, if any, the duct must be slanted about 10%
downwards.
The maximum recommended length of ducting is 10 feet with a maximum of two bends. The suction power
of the chimney considerably decreases in case the length of the duct and number of bends increases
further.
USAGE