manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Care Call
  6. •
  7. Security Sensor
  8. •
  9. Care Call CCM3A-2216-EU-PIR User manual

Care Call CCM3A-2216-EU-PIR User manual

Quick start guide CCM3A-2216-EU-PIR
Care Call passive infra red (PIR) movement monitor
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UKCLOFIELD LTD. UK
TEL 01246 260045
Care
Call
MOVE KEY DOWN
TO SWITCH ON
Movement Activation
Use the following guide to set up your monitor to illuminate zone one on your Pager or SignWave when triggered.
For advanced settings please refer to instructions overleaf.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10= PIR Delay 10 Mins
9& 10 = PIR Delay 15 mins
11= Zone 6
12= Zone 5
13= Zone 4
14= Zone 3
15= Zone 2
16= Zone 1
MOVE KEY DOWN
TO SWITCH ON
2. The test button will flash amber /
green on start up, then flash
amber for up to 30 seconds whilst
the movement sensor stabilises.
This is normal.
Sound Activation
It is possible to enable sound monitoring as well as movement detection. Audio trigger delays can be used to reduce false
alarms from transient noise (door slams etc).
Move Key 16 to the right. Connect the power
supply (PS3A-2207-UK) into the unit, looping
the cable around the strain relief. Plug the
power supply into a mains socket.
If mains failure monitoring is required connect
a 9V Alkaline PP3 to the battery clip.
1.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UKCLOFIELD LTD. UK
TEL 01246 260045
Alkaline
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Move keys 5 & 7
to the right.
1.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UKCLOFIELD LTD. UK
TEL 01246 260045
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Configuration switches
Audio spindle
Test button
PP3 battery clip
Power Supply socket
Passive
infra red
movement
sensor
Turn the spindle on the side of the
monitor half a turn clockwise until the
slot is horizontal.
A good way to test the unit is to
whistle about 2 metres away from it.
More sensitive Less sensitive
2. The test button will light amber
when a sound is detected and
change to green once it has
been accepted.
Switches 7 & 8 alter the
delay period.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
short medium long
3.
Any questions? Call us on 01246 450789
40 - 70cm
3.Position the unit & adjust the sensor
to cover the area you wish to
monitor. Ensure the unit is at least
40cm from the floor & fix to the wall
with the screws and wall plugs
provided. Use the keyhole slots in
the back of the unit to secure.
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 Mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
38mm
TOP
Drill Template
WARNING! Your device and its accessories are not toys. They may contain small parts. Keep them out of the reach of small children.
Advanced Settings CCM3A-2216-EU-PIR
Care Call passive infra red (PIR) movement monitor
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
Care
Call
MOVE KEY DOWN
TO S
W
ITCH ON
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
Move Key 9 across to
the right to enable the
movement delay.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2 = System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Movement return delays
It is possible to add a movement trigger delay to enable a period of time to pass from the sensor
detecting movement to the monitor sending a signal. This can be useful to allow a user get a drink
or visit the bathroom without triggering the system.
A count down timer will start. If the
person returns within the time period the
monitor will disarm and reset.
Now, instead of triggering instantly the
monitor will display it has detected
movement by flashing the test
button orange.
VI
IX III
5 MINUTES
Key 9
=
5 minutes
Keys 9 & 10
=
15 Minutes
Key 10
=
10 minutes
If the monitor doesn't detect
movement in the allotted time it
will send a signal to the
Pager or SignWave.
The timer is configurable as shown.
1. 2. 3.
Any questions? Call us on 01246 450789
Zones seven to twelve are displayed
using a numbered key together with the
battery key (+6).
To enable this feature move key 6 and
one of the zone keys to the right.
Zone 7 is therefore shown as zone one
+ the battery key.
Zone 8 is shown as zone 2 + the battery
key and so on.
9
10
11
12
13
14
15
16
4
9
10
11
12
13
14
15
16
5
9
10
11
12
13
14
15
16
6
9
10
11
12
13
14
15
16
3
9
10
11
12
13
14
15
16
21
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
1
The monitor can be coded to light any one of twelve zones on the Pager or SignWave.
The diagram below shows the relevant key settings for zones one to six.
Zone Setting
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 = Zone 7
Changing the system channel code
NOTE: In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other Care Call systems using up to a maximum of 16 channels.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
23456 7 8
9 10 11 12 13 14 15 16
1
Advanced Settings CCM3A-2216-EU-PIR
Care Call passive infra red (PIR) movement monitor
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
Care
Call
MOVE KEY DOWN
TO S
W
ITCH ON
Transmit the unit
by either:
1. Triggering the PIR
2.Triggering the
sound detection
3. Pressing the
test button
The test button will
briefly light green and a
signal will be sent to the
Pager or SignWave.
Disarm the Carer Alerts
It is now possible to disarm the PIR sensor and audio monitoring feature when not required.
1.
Any questions? Call us on 01246 450789
3. WARNING
Whilst the test button is lit solid orange the monitor will NOT alert the Carer to an event.
It is important to remember to rearm the monitor when required.
2.
Within 10 seconds after the
unit has transmitted press
and hold the test button
until it lights solid orange.
This shows the unit is now
disabled. It will no longer
respond to any movement
or sound until it
is rearmed.
Disarm the sensors
Rearm the sensors
1. Press and hold the test button.
It will light green briefly and the PIR
will reset.
2. The test button will flash
amber for up to 30 seconds
whilst the movement sensor
stabilises. This is normal.
3.
When the key light goes out
the monitor is armed and
ready to go.

Popular Security Sensor manuals by other brands

Eelectron PD00E11KNX user manual

Eelectron

Eelectron PD00E11KNX user manual

careium Ellis quick start guide

careium

careium Ellis quick start guide

Alula RE610P manual

Alula

Alula RE610P manual

Honeywell Notifier FSP-951AUS Installation and maintenance instructions

Honeywell

Honeywell Notifier FSP-951AUS Installation and maintenance instructions

Leviton decora OSSMT-M3 installation instructions

Leviton

Leviton decora OSSMT-M3 installation instructions

Migma MigmaIntersection installation guide

Migma

Migma MigmaIntersection installation guide

BEMKO SES07WH user manual

BEMKO

BEMKO SES07WH user manual

Baolong TMSS6D4 Operation manual

Baolong

Baolong TMSS6D4 Operation manual

Zublin SG360P Dimm operating instructions

Zublin

Zublin SG360P Dimm operating instructions

Siemens FDOOTC441 installation instructions

Siemens

Siemens FDOOTC441 installation instructions

REXROTH DBA Series manual

REXROTH

REXROTH DBA Series manual

AJAX FireProtect 2 Jeweller manual

AJAX

AJAX FireProtect 2 Jeweller manual

Crestron CNXRMIRD Operation guide

Crestron

Crestron CNXRMIRD Operation guide

Crow SH-PIR-8F user manual

Crow

Crow SH-PIR-8F user manual

Tynetec ZXT413 manual

Tynetec

Tynetec ZXT413 manual

GORBEL Tether Track TTM-FSC Installation, operation & maintenance manual

GORBEL

GORBEL Tether Track TTM-FSC Installation, operation & maintenance manual

Alltech ELSD 2000 manual

Alltech

Alltech ELSD 2000 manual

SENTRONIC AM103 user guide

SENTRONIC

SENTRONIC AM103 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.