CARLO GAVAZZI G3800 X015 - CONFIGURATION SOFTWARE User manual

Configuration Software
G3800 X015
User Manual
Preliminary Data
December 2002
Du line
®
Fieldbus Installationbus

2© 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
1. Introduction 4
1.1. Start-up 4
1.1.1. Hardware requirements 4
1.1.2. Installation 4
1.1.3. Start-up of program 4
1.2. Functions in the main window 5
1.2.1. File menu 5
1.2.2. Edit menu 6
1.2.3. Select menu 7
1.2.4. Tools menu 7
1.2.5. Help menu 8
1.2.6. Configuration of channel functions 9
1.3. Basic Setup 10
2. Objects 11
2.1. General 11
2.2. Standard objects 12
2.2.1. Blank channel (no function) 12
2.2.2. The push-button function 13
2.2.3. The toggle switch function 15
2.2.4. Timer/Recycler 17
2.2.5. Real-time clock 20
2.2.6. Master function 22
2.3. Special objects 25
2.3.1. Analog sensors 25
2.3.2. Motion detector 30
2.4. Alarm functions 33
2.4.1. Overview 33
2.4.2. General features 33
2.4.3. ISA Alarm 34
2.4.4. The Smoke Alarm 39
2.4.5. The Intruder Alarm 44
2.4.6. The Water Alarm 50
2.4.7. Common Siren 55
2.5. Roller blind control 56
2.5.1. Decentralized roller blind up-down function 56
2.5.2. Roller blind master 61
2.6. Counter and Multiplexer 64
2.6.1. Multiplexer (transmission of counter values) 64
2.6.2. Multiplexer (transmission of analog values) 66
3. Logic Setup 68
3.1. Introduction 68
3.2. The dialog - logic functions 68
3.2.1. Setup 68
3.3 Application 69
3.3.1. Setups and Functions 69
3.3.2. Inversion and Edge Triggering 70
3.3.3. Using flags 71
3.3.4. Internal processing of the logic setups 71
3.4. Notes and Documentation 71
4. GSM Modem functions (only valid for G38001015) 72
4.1. SMS Setup 72
4.2 Event-based SMS messages 73
4.3. SMS Control commands and Requests for Dupline data 74
5. Radio Modem driver 76
5.1. General 76
5.2 Setup of Radio Modem Central 77
5.3. Setup of Radio Modem Substation 78
Table of Contents

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 3
G 3800 X015 Configuration Software October 2002

4© 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
1. Introduction
The G38xx15 program has been designed for configuration of the G3800X015 master generator. All functions
in the generator are represented by graphic symbols. To each channel function are related parameters and
comments, which can be edited locally in the PC and transferred to the master generator through RS232.
Likewise, data from the master generator can be uploaded and edited.
1.1. Start-up
1.1.1. Hardware requirements
• The program operates under Windows 95/98/2000/xp and NT and requires at least:
• 486 processor with 8 Mbytes Ram or higher
• A free serial port (Com1 or Com2)
• 5 Mbytes hard disk for installation
• Screen resolution of 800 x 600 pixels, 256 colours or higher
• Mouse or other pointing tool desirable, but not necessary
1.1.2. Installation
Insert disk 1 in the A-drive and run the program “Setup.exe”. This will guide you through the installation pro-
cess. After installation, the program can be started by clicking G38xx15.
1.1.3. Start-up of program
When G38xx15 is started, two windows will open:
To the left, the main window showing the 128 channels available in Dupline and the menus. To the right, the
properties window, which for each function shows the parameters related to this particular function.

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 5
G 3800 X015 Configuration Software October 2002
1.2. Functions in the main window
1.2.1. File menu
The file menu contains the usual functions:
Menu Item: Explanation
New: Start from the beginning with default data
Open: Open existing file
Save: Save file
Save As: Save file under new name
Write Generator: Download the present configuration file to the Generator
Read Generator: Read the configuration file from the Generator
Print: The following options are available:
Print-out of:
Address Listing
Master Channels
Real time Channels or
Logic Settings
SMS Setup
Exit: Exit program

6© 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
Menu Item: Explanation:
Basic Setup: Basic setup of the G3800X015 generator
Logic Setup: Configuration of logic functions
Holiday Setup: Setup of holiday period. The holiday setup is active when
the current date falls within any of the set time intervals.
SMS (only valid for G38001015) Basic setup of the SMS messaging functions facilitated by
the built-in GSM modem.
Counter and Mux analog Setup: Basic setup of the multiplex functions required when
Counter Modules and Multiplexed Analog Modules are
used.
Communication Setup: Configuration of the communication functions available for
the two RS 232 ports and the RS485 port of the Generator.
1.2.2. Edit menu

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 7
G 3800 X015 Configuration Software October 2002
Menu Item: Explanation:
Language: Select between 3 languages. By using the “Select new” menu,
other languages can be inserted in the 3-language menu.
Serial port: Selection of Com 1, Com 2, Com 3 or Com 4 port, for connection
of the G3800X015 Generator.
1.2.4. Tools menu
Generator firmware: In this menu it is possible to download a new firmware file to the Generator. New
firmware files are typically made available when new features are added to the Generator. Three steps need to
be carried out:
1. Browse to select the desired firmware file.
2. Activate the Download button
3. Activate the program button
1.2.3. Select menu

8© 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
Menu Item: Explanation:
General information: You can call the Help menu at any time by pressing F1.
About program: Shows the opening screen
1.2.5. Help menu

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 9
G 3800 X015 Configuration Software October 2002
When the basic settings have been made under “Basic Setup”, the functions of the remaining channels to be
used are defined as follows:
Activate one of the channels, then click on the right mouse button for pop-up menu. Click on the desired
channel function with the left mouse button. The channel is thereby assigned a symbol indicating the selected
channel function. Click on the symbol with the left mouse button, and the parameters which can be set for
that particular channel function can be viewed in the properties window.
The arrow keys can also be used to select channel function in the pop-up menu. Furthermore, channel func-
tion can be selected by clicking on different letters. To see how to select functions by clicking on letters,
select the General information menu under Help.
Tool tip
When the cursor is positioned on a channel button, a bar appears indicating channel number, describing
channel type and showing the user-defined channel description.
1.2.6. Configuration of channel functions

10 © 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
1.3. Basic Setup
General description
The text window is for entering general information, eg name of user, date of configuration, reference to docu-
mentation, etc.
No. of channels
For selection of the number of channels desired in the system. The minimum is 8, the maximum is 128 in one
Dupline network.
Auto-start Dupline on short-circuit
In case of a short-circuit on Dupline, the Generator shuts down the Dupline signal. Under default conditions,
power-off followed by power-on needs to be performed to reset the Generator after removal of the short-cir-
cuit. However, if the "Auto-start Dupline on short-circuit" box is checked, then the Generator will automatically
start up the Dupline signal after removal of the short-circuit.
Enable automatic update of realtime status upon Config-download and System power-up
If this box is checked, the Generator will automatically set the correct status for realtime channels according
to the switch-time settings, provided that the actual Day of the week matches the internal Day of the week of
the Generator. Also, the Generator will only scan the switch times (ON or OFF) for that same day.
Enable Automatic Daylight saving. Central European Time standard
If this box is checked, the Generator will automatically change the time settings 2 times per year according to
the European standard for daylight savings.
Enable RTC Powerline Autocalibration
Selecting Auto-calibrate, will enable the internal Realtime clock to adjust its internal calibration against the
Mains-supply frequency. In most countries, the Mains-supply frequency is very accurate, and in that case an
improved accuracy on the Realtime clock can be achieved.
Syncronize Time to PC date and Time
If this button is activated when the Generator is connected to the PC, then the PC date and time will be trans-
ferred to the realtime clock of the Generator.

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 11
G 3800 X015 Configuration Software October 2002
2.1. General
The objects are the specific functions of the G 3800 X015. The functions are assigned to channels, and the
associated parameters determines the operation of the channels.
2. Objects

12 © 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
2.2.1. Blank channel (no function)
Description
The use of blank channels in Dupline is based on the circumstance that in- and output are independent of
each other. Since this object does not fulfill a function between in- and output, an input on the address con-
figured as blank function will be ineffective.
At the same time, it is possible to control the channel - and consequently the functions coded for the
address - either through the master function (see chapter 2.2.6) or as output of logic setups (see chapter 3). In
addition, a blank channel can be used as a monostable flag.
Parameters
None.
• Function: None
• Application: Activation of output channels through master functions or logic setups
• Insert with mouse (“Blank channel”)
2.2. Standard objects

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 13
G 3800 X015 Configuration Software October 2002
2.2.2. The push-button function
Description
The push-button function - the most simple object of the Dupline Master Generator - makes it possible to
connect any type of push button switch and contact to the Dupline bus. With this function, outputs can indi-
rectly be controlled with logic functions.
In this function, the output follows the input signal: the output is activated as long as the input signal is ON
(inverted in Normally Closed function).
Parameters
Configuration window of push-button function:
Time characteristics
t
t
PManTTast_1a
t3
t2
t1
t
t
PManTTast_2a
t3
t2
t1
The output follows the input upon a short delay. In the Normally closed function, the output function is the
opposite of the input function.
Parameter Description
Inverted function When this function is selected, the output signal is inverted. This means that the
output is activated as long as the input has not been set.
• Function: Monostable
• Application: Connection of push-button switches and contacts for load
switching
• Also Normally Closed function
• Select with mouse (“Push button”) or short-cut key “0” (Zero)
Normally Open Normally Closed
IN IN
OUT OUT

14 © 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
Object Function Channel
In-/outputs
Relay output Lamp A1
Switch Light switch A1
Configuration of Master Generator
Push button function Light control A1
Application Example
Task: A lamp is to be switched on and off by means of a switch.
Solution: Use for example the universal input module to provide the input signal and configure one of the
inputs for address A1. Assign the same address to one of the outputs of a relay module. Finally,
configure channel A1 in the Master Generator as push button function.

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 15
G 3800 X015 Configuration Software October 2002
2.2.3. The toggle switch function
Description
The toggle switch function makes it possible to simulate the operation of a toggle switch: Pressing the switch
once activates the output, pressing the switch once more de-activates the output again.
Parameters
Configuration window of the toggle switch function:
Time characteristics
t
t
PMan_TToggle_1a
t3
t2
t1
The first triggering of the input switches the output on, the second triggering switches the output off again.
Parameter Description
Intruder alarm When this function is selected, the input is used in a configured intruder alarm
system. This means that in an armoured alarm system with no time delay set, an
alarm is released when the input is activated.
• Function: Bistable Flip-Flop
• Application: Connection of switches and contacts for load switching
• Can be used in intruder alarm systems
• Select with mouse (“Toggle switch”) or short-cut key “F”
IN
OUT

16 © 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
Object Function Channel
In-/outputs
Relay output Lamp A1
Switch Light switch A1
Configuration of Master Generator
Toggle switch function Light control A1
Application Example
Task: A lamp is to be switched on and off by means of a conventional switch.
Solution: Use for example the universal input module to provide the input signal and configure one of the
inputs for address A1. Assign the same address to one of the outputs of a relay module. Finally,
configure channel A1 in the Master Generator as switching function.

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 17
G 3800 X015 Configuration Software October 2002
2.2.4. Timer/Recycler
Description
This object makes it possible to select between two modes of operation: timer and recycler. In both modes,
an input coded to the channel of the timer starts the functions, but the input can also be activated by a differ-
ent channel or flag.
Timer (with on-delay or off-delay)
The timer allows the setting of an on-delay and/or an off-delay. When an input coded to this channel is acti-
vated, the on-delay starts. After elapse of this delay, the Off time starts. The Off time stops after the set time, if
the input is released before expiry of the set time. If the input is not released, the output remains activated.
Recycler
If the recycler is activated by an input, the recycler continuously generates a square-wave signal. The output
is activated after the set on-delay period and de-activated after the set off-delay period. This process is
repeated, as long as the input or the additional trigger is ON.
Parameters
Depending on the options selected under Timer function, a number of parameters can be selected for Timer
and Recycler:
Timer (with on-delay or off-delay)
Configuration window for timer with on- or off-delay:
Parameter Description
Timer function Select the option On-Off delay, in order to use the Timer function
Activation by pulse Select this option to start the timer by means of a short impulse, eg through a
push button switch
On delay Enter the time (0 s to 99 h, 59 min, 59 s) which must pass before the channel is
activated
Off time Enter the time (0 s to 99 h, 59 min, 59 s) for which the channel should be activat-
ed
• Function: Timer or Recycler
• Application: Switching with on- or off-delay or recycler
• Activation by signal or impulse
• Activation by additional channel or flag
• Select with mouse “Timer” or short-cut key “T”

18 © 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
Time characteristics
Timer with on- or off-delay
t
t
PMan_TTimer_1a
t2
t1t3t4t5t7
t6
The on-delay tEstarts shortly after the input signal at time t1. After elapse of the delay, the On-time tNstarts.
After elapse of the On-time (t3), the output switches off again. To achieve this, the input must be reset before
time t3.
Parameter Description
Enabled by address Entering of an additional channel (A1..P8) or flag (W1..Z8) which will also enable
the timer function. To prevent locking, the channel assigned to the timer itself
must not be used.
If the additional signal is an impulse, select the option Activation by pulse.
Recycler
Configuration window for recycler
Parameter Description
Timer function To select the Recycler function, select “Recycler”
On-time Entering of the time (1 s to 99 h, 59 min, 69 s) for which the output is On during
recycling
Off-time Entering of the time (0 s to 99 h, 59 min, 59 s) for which the output is Off during
recycling
Enabled by address Entering of an additional channel or flag which will also enable the recycler. To pre-
vent locking, the channel assigned to the recycler itself must not be used.
IN
OUT
TETE
TNTN

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 19
G 3800 X015 Configuration Software October 2002
Object Function Channel
In-/outputs
Relay output Bathroom light A1
Switch Light switch A1
Relay output Bathroom fan A2
Configuration of Master Generator
Toggle switch function Light control A1
Timer Fan control A2
Application Example
Task: A fan in a bathroom is to start 5 min after the light has been switched on and run for 10 min.
Solution: The lighting is activated by a push button connected to a sensor module (for example a univer-
sal input module) and configured for address A1 as a toggle switch function. An output of a
relay module is assigned the same address and activates the lighting. A second channel A2 is
configured as Timer and activated by the above-mentioned push button. An additional channel
of the output module is also assigned the address A2 and activates the fan.
Recycler
The impulse is generated shortly after the input has switched on at time t1. A pulse cycle consists of the On-
time tEand the Off-time tA. When the input is switched off, the pulse cycle also ends.
t
t
PMan_TTimer_2a
t2
t1t4
t3
IN
OUT
By use of the additional trigger A1, the timer starts when the light is switched on.
TETA

20 © 2002 Carlo Gavazzi Industri A/S. All rights reserved
G 3800 X015 Configuration Software October 2002
2.2.5. Real-time clock
Description
The real-time clock enables on- and off-switching of loads in relation to the internal time setting of the Master
Generator. It is possible to pre-define up to four switch-on and switch-off times for each clock on freely
selectable weekdays and holidays.
Parameters
Configuration window of real-time clock function:
Time characteristics
t
t
PMan_TReal_1a
t2
t1t4
t3t5
• Function: Real-time clock with week and holiday planner
• Application: Time-controlled switching on and off of loads
• Also applicable as switching function
• Holiday setting can be performed centrally for all clocks
• Select with mouse “Real-time” or short-cut key “R”
IN
OUT
Parameter Description
Switch-on time Time at which the channel is to switch on
Switch-off time Time at which the channel is to switch off
Days of week Day(s) on which the switching time indicated to the left applies
(M: Monday, T: Tuesday, W: Wednesday, T: Thursday, F: Friday, S: Saturday,
S: Sunday)
If “H” is activated, the clock also switches on holidays. In this case, the corre-
sponding days must be entered under <Edit><Holiday setup>.
This manual suits for next models
1
Table of contents
Other CARLO GAVAZZI Software manuals
Popular Software manuals by other brands

Genius
Genius VOIP MOUSE introduction

Novell
Novell BUSINESS CONTINUITY CLUSTERING 1.0 -... manual

Red Hat
Red Hat NETWORK - USER REFERENCE GUIDE 2.0 User reference guide

Brother
Brother 1960C - IntelliFAX Color Inkjet Software user's guide

Red Hat
Red Hat ENTERPRISE LINUX 5 - VIRTUAL SERVER... Configuration guide

mca
mca CERS Port user manual

Lenovo
Lenovo THINKPAD T41 manual

ASROCK
ASROCK A780GMH-128M installation guide

Alcatel
Alcatel OmniTouch ACS 7.1.4 Site preparation guide

Dell
Dell PowerEdge UPS 500T user guide

Blackbe;rry
Blackbe;rry JAVA DEVELOPMENT ENVIRONMENT Getting started guide

Autodesk
Autodesk CAICE VISUAL SURVEY 10 features and benefits