Catcast HP8516T User manual

HP8516T 8 CH Mux DVB-T Modulator
User’s Manual
Web-NMS Version: 1.10
Software: 4.11
Hardware:1.00
Catcast Technology Co., Ltd. (Chengdu)

DIRECTORY
Chapter 1 Product Outline..........................................................................................1
1.1 Outline...................................................................................................................................1
1.2 Features.................................................................................................................................1
1.3 Principle Chart......................................................................................................................2
1.4 Technical Specifications.......................................................................................................2
1.5 Appearance and description..................................................................................................3
Chapter 2 Installation Guide...................................................................................... 5
2.1 Acquisition Check.................................................................................................................5
2.2 Installation Preparation.........................................................................................................5
2.3 Wire’s Connection................................................................................................................7
2.4 Signal Cable Connection...................................................................................................... 7
Chapter 3 Web-based NMS Management.................................................................9
4.1 login...................................................................................................................................... 9
4.2 Operation...............................................................................................................................9
Chapter 4 Troubleshooting.......................................................................................18
Chapter 5 Packing List..............................................................................................19

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
1
Chapter 1 Product Outline
1.1 Outline
HP8516T is a high performance and cost-effective DVB-T modulator designed by
Catcast. It has 16 DVB-S/S2 FTA tuner input, 8 groups multiplexing and 8 groups
modulating, and supports maximum 512 IP input through GE1 and GE2 port and 8 IP
(MPTS) output through GE1 port and 8 non-adjacent carriers (50MHz~960MHz) output
through the RF output interface. To meet customers’ various requirements, this device is
also equipped with 2 ASI input ports.
HP8516T is also characterized with high integrated level, high performance and low
cost. It supports dual power supply (optional). This is very adaptable to newly
generation broadcasting system.
1.2 Features
16 DVB-S/S2 FTA Tuner + 2 ASI input+512 IP (GE1 and GE2) input over
UDP and RTP protocol
8*DVB-T RF output
Excellent RF output performance index, MER≥40db
Support 8 groups multiplexing + 8 groups DVB-T modulating
Support accurate PCR adjusting
Support PSI/SI editing and inserting
Support Web management, Updates via web
Redundancy Power Supply (optional)

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
2
1.3 Principle Chart
1.4 Technical Specifications
Input
16 DVB-S/S2 FTA Tuner
512 IP (GE1 and GE2)input over UDP and RTP protocol
2 ASI input, BNC interface
Tuner
Section
DVB-S
Input Frequency 950-2150MHz
Symbol rate 2-45Msps
Signal Strength -65~-25dBm
FEC Demodulation 1/2, 2/3, 3/4, 5/6, 7/8
QPSK
DVB-S2
Input Frequency 950-2150MHz
Symbol rate QPSK 1~45Mbauds
8PSK 2~30Mbauds
Code rate 1/2, 3/5, 2/3, 3/4, 4/5, 5/6,
8/9, 9/10
Demodulation Mode QPSK, 8PSK
Multiplexing
Maximum PID
Remapping 128per input channel
Function PID remapping (automatically or manually)
Accurate PCR adjusting
Generate PSI/SI table automatically
Modulation
Standard: EN300 744
FFT: 2K 8K
Bandwidth: 6M, 7M, 8M
Constellation: QPSK, 16QAM, 64QAM

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
3
Guard interval: 1/4, 1/8, 1/16, 1/32
FEC: 1/2, 2/3, 3/4, 5/6, 7/8
Stream
output
8 IP(MPTS) output over UDP /RTP, 100M/1000M self-adaption
8 DVB-T RF output
Remote
management Web NMS(10M/100M)
Language English and Chinese
Software Upgrading Web
General
Dimension
(W*D*H) 482mm×300mm×44.5mm
Weight 3.7kg
Temperature 0~45℃(Operation) ; -20~80℃(Storage)
Power AC 100V±1050/60Hz;
AC 220V±10%, 50/60HZ
Consumption 25W
1.5 Appearance and description
Front Panel Illustration:
1 Power indicator
2Reset: Reset webmaster IP address, recover it to default IP
address
3 USB port for upgrade
4 NMS port: Network management interface
5 Data port(GE1&GE2): IP out port
6 ASI input port
7 RF output port

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
4
Rear Panel Illustration
1 16 channels RF IN Interface
2 Integrated power switch and socket
3 Grounding Wire

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
5
Chapter 2 Installation Guide
2.1 Acquisition Check
When user opens the package of the device, it is necessary to check items according to
packing list. Normally it should include the following items:
HP8516T 8 CH Mux DVB-T Modulator 1pcs
User’s Manual 1pcs
RF/Loopout Cables 7pcs
Power Cord 1pcs
2.2 Installation Preparation
When users install device, please follow the below steps. The details of installation will
be described at the rest part of this chapter. Users can also refer rear panel chart during
the installation.
The main content of this chapter including:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing modulator
Connecting signal cables
Connecting communication port (if it is necessary)
2.2.1 Device's Installation Flow Chart Illustrated as following:
2.2.2 Environment Requirement

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
6
Item Requirement
Machine Hall Space
When user installs machine frame array in one machine
hall, the distance between 2 rows of machine frames
should be 1.2~1.5m and the distance against wall should
be no less than 0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
1X107~1X1010Ω,Grounding current limiting resistance:
1M (Floor bearing should be greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ),0~45℃(short time),
installing air-conditioning is recommended
Relative Humidity 20%~80% sustainable 10%~90% short time
Pressure 86~105KPa
Door & Window Installing rubber strip for sealing door-gaps and dual
level glasses for window
Wall It can be covered with wallpaper, or brightness less paint.
Fire Protection Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and
lighting power are independent to each other. Device
power requires AC power 100-240V 50-60Hz. Please
carefully check before running.
2.2.3 Grounding Requirement
All function modules’ good grounding is the basis of reliability and stability of
devices. Also, they are the most important guarantee of lightning arresting and
interference rejection. Therefore, the system must follow this rule.
Coaxial cables outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high
frequency impedance, and the grounding wire must be as thick and short as
possible.
Users should make sure the 2 ends of grounding wire well electric conducted and

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
7
be antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be
no less than 25mm2.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The
grounding wire should be as short as possible and avoid circling. The area of the
conduction between grounding wire and grounding strip should be no less than 25mm2.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the
power switch, fuse, power supply socket is just beside ,whose order goes like this,
power switch is on the left ,power supply socket is on the right and the fuse is just
between them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC
power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent
way, say, share the same ground with other devices. When the device adopts united
way, the grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to
HP8516T 8 CH Mux DVB-T Modulator, user
should set the power switch to “OFF”.
2.4 Signal Cable Connection
The signal connections include the connection of input signal cable and the connection

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
8
of output signal cable. The details are as follows:
HP8516T 8 CH Mux DVB-T Modulator Cable Illustration:
NMS Cable illustration (CAT5):
RF Input/Loop Cable Illustration:

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
9
Chapter 3 Web-based NMS Management
Users can only control and set the configuration with the web Brower in the PC.
4.1 login
The default IP address of this device is 192.168.0.136. (We can modify the IP through
the front panel.)
Connect the PC (Personal Computer) and the device with net cable, and use ping
command to confirm they are on the same network segment.
I.G. the PC IP address is 192.168.99.252, we then change the device IP to
192.168.99.xxx (xxx can be 1 to 254 except 252 to avoid IP conflict).
Use web browser to connect the device with PC by inputting the Encoder &
Modulator’s IP address in the browser’s address bar and press Enter.
It will display the Login interface as Figure-1. Input the Username and Password (Both
are defaulted as “admin”.) and then click “LOGIN” to start the device setting.
Figure-1
4.2 Operation
Summary:
When we confirm the login, it displays the WELCOME interface as Figure-2 where
users can have an overview of the device’s system information and working status.

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
10
Figure-2
Parameters →
→→
→Tuner 1-16
HP8516T support 16 DVB-S/S2 Tuner input. From the menu on left side of the
webpage, clicking “Tuner1-16”, it displays the information of each encoding channel
as Figure-3.
Figure-3
Parameters →
→→
→TS Config:
From the menu on left side of the webpage, clicking “TS Config”, it displays the
interface where users can configure the TS output parameters.
TS Config→
→→
→Output TS:
From the menu on top side of the webpage, clicking “Output TS X”, it displays the
System language setting
User can click any item here to enter
the corresponding interface to check
information or set the parameters.
System
information

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
11
interface where users can check output TS of each channel. (Figure-4)
Figure-4
TS Config→
→→
→Stream select:
From the menu on up side of the webpage, clicking “Stream select”, it displays the
interface where users can select program(s) to multiplex out and modify program info.
(Figure-5)
Figure-5
Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions
are as below:
: To check input IP lock or not, green means current IP locked
: To check current TS overflow or not, red color means current TS
Input Area Output Area
Operation Area

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
12
overflow, need reduce program
: To filter/not filter the source CA information
: To enable/disable the PID remapping
To refresh the input program information
To refresh the output program information
Select one input program first and click this button to transfer the selected
program to the right box to output.
Similarly, user can cancel the multiplexed programs from the right box.
To select all the input programs
To select all the output programs
To parse programs time limitation of parsing input programs
Program Modification:
The multiplexed program information can be modified by clicking the program in the
‘output’ area. For example, when clicking , it triggers a dialog box
(Figure 6) where users can input new information.
Figure-6
TS Config→
→→
→General:
From the TS Config menu on up side of the webpage, clicking “General”, it displays
the interface where users can set output mode, enable PSI/SI table out, NIT
insert/VCT insert, PCR correction. (Figure-7)

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
13
Figure-7
TS Config→
→→
→PID Bypass:
From the TS Config menu on up side of the webpage, clicking “PID Bypass”, it
displays the interface as Figure-8 where user can add PIDs to be passed, click the “+”
symbol, input current IP channel number, then input current IP source Pid and output
Pid which is customer needed , then click “set”
Figure-8
Parameters →
→→
→Modulator:
From the menu on left side of the webpage, clicking “Modulator”, it will display the
Modulator Configuration screen as Figure-9. Here user can set modulation parameters.

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
14
Figure-9
Parameters →
→→
→IP Stream:
HP8516T supports TS to output in IP (8*MPTS) format through the DATA port.
Click ‘IP Stream’, it will display the interface where to set IP out parameters
(Figure-10).
Figure-10
System →
→→
→Network:
Click ‘Network’, it will display the interface as Figure-11 where to set network
parameters.
Click here to
Config IP output
Quickly Config
Channel Config

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
15
Figure-11
System →
→→
→password
From the menu on left side of the webpage, clicking “Password”, it will display the
screen as Figure-12 where to set the login account and password for the web NMS.
Figure-12
System →
→→
→Configuration:
From the menu on left side of the webpage, clicking “Configuration”, it will display
the screen as Figure-13 where to save/ restore/factory setting/ backup/ load your
configurations.

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
16
Figure-13
System →
→→
→Firmware:
From the menu on left side of the webpage, clicking “Firmware”, it will display the
screen as Figure-14 where to update firmware for the modulator.
Figure-14
System→
→→
→Log:
From the menu on left side of the webpage, clicking “Log”, it will display the log
interface as Figure-15 where to check or export the Kernel/System log.

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
17
Figure-15

HP8516T 8 CH Mux DVB-T Modulator User’s Manual
18
Chapter 4 Troubleshooting
Catcast’s ISO9001 quality assurance system has been approved by CQC organization. For guarantee
the products’ quality, reliability and stability. All Catcast products have been passed the testing and
inspection before ship out factory. The testing and inspection scheme already covers all the Optical,
Electronic and Mechanical criteria which have been published by Catcast. To prevent potential
hazard, please strictly follow the operation conditions.
Prevention Measure
Installing the device at the place in which environment temperature between 0 to 45 °C
Making sure good ventilation for the heat-sink on the rear panel and other heat-sink bores if
necessary
Checking the input AC voltage within the power supply working range and the connection is
correct before switching on device
Checking the RF output level varies within tolerant range if it is necessary
Checking all signal cables have been properly connected
Frequently switching on/off device is prohibited; the interval between every switching on/off
must greater than 10 seconds.
Conditions need to unplug power cord
Power cord or socket damaged.
Any liquid flowed into device.
Any stuff causes circuit short
Device in damp environment
Device was suffered from physical damage
Longtime idle.
After switching on and restoring to factory setting, device still cannot work properly.
Maintenance needed
Table of contents