Features
Installation
Power On Procedure
Front Panel LED Indications
Sound Indications
Display explanations
Always ARMED Sensors
Arm
ARM Bypass
ARM / DISARM Confirmation Sounds control
Auto Arm / Disarm Time + Holidays
Battery Mode - Power Switch Off in
CMS (Central Monitoring Station)
Date / Time Setting
Disarm
Delay to ARM
Panic Key
Panic Key –Silent
Passwords
Password Operation On / Off
Record of History
Remote monitoring through Telephone line
Remote monitoring during intrusion
Resetting to Factory Settings
Resetting SIM
SIM Alarm Enable/ Disable
SIM Balance Checking
Siren Hooting time
Siren ON or OFF
Siren Wireless or Flashing Siren-Wireless (FSW) Registering
Siren Wireless Flashing Siren-Wireless with Tamper Protection (FSW-T) Registering
Signal Repeater –Wireless
Signal Strength Test of GSM
Make sure you get a
printed Index made
from the installer &
paste the same behind
Keyboard panel.

SMS Text & Android Application for various programming
Telephone Numbers Entry & SMS Controls
Telephone Number Redial Times
Telephone Number Display - ON / OFF
Voice Message Recording for playing on Telephone calls during Intrusion - Optional
Wireless Sensors, Remotes & Panic Keys Registering/Deletion
Wireless Sensor –Operating Mode
Wired Zones –Operating Mode
Wired Zones Programmable Delay
Wired Zones Sensing Delay
Precautions
Trouble Shooting
Technical Specifications
Terms of Warranty
Index of - Wireless Sensor Numbers & their corresponding Names
Note:
-Copper Connections Pvt. Ltd reserves the right to alter equipment specifications and descriptions contained herein
and make no commitment to update or keep current the information herein.
All information herein is subject to change at any time without notice. No part of this publication shall be deemed to
be part of any contract or commitment whatsoever.
-Product specifications and features are subject to changes without prior notice due to our constant endeavor to
improve the product.
.Features .
Auto Detect Open Door
When the system is being ARMED, if any door having Magnetic Switch (Wired or Wireless) is open, the system will
alert the user with a intermittent Siren Sound. The same is true for all wired sensors.
During this time, if the Opened Sensor or the opened Wired Zone is closed, the system will get ARMED and the
intermittent Siren sound will stop.
The main Panel display in this case is explained under the heading “Display explanations” – sub heading “while
Arming the system”.
Always Armed Zones
Some sensors can be configured to work 24 Hours. Whether the system is ARMED or not, these sensors would
initiate Siren hooting and Telephone dialing.
For example, a heat detector can be placed near Generator so that whenever generator heats due to a fault, the
siren would alert the user & also inform on his Cell number.
For further details refer the heading “Wireless Sensor – Operating Mode” and “Wired Sensor – Operating Mode”
Auto ARM / DISARM - Day Wise
System can be programmed to ARM / DISARM at 3 different sets of timings for each day of the week. User can also
enter up to 10 Holidays in the system. On those days the system continues in the previous day’s status
Example: If the user has off days on Saturday and Sunday then the system can be programmed to remain ARMED
on these 2 days. And for rest of the week the system will ARM & DISARM at the set time. For further
details refer the heading “Auto Arm / Disarm Time”
ARM Bypass
User has option to ARM all the Zones or selected Zones. This helps in ARMING the system while servants are
present in some part of the building. For further details refer the heading “ARM Bypass”
Auto Dialer (Dialing through GSM SIM during intrusion)
The system dials up to 6 Telephone numbers and plays siren sound (pre-recorded message-Optional), during
intrusion. After 10 secs of Siren Sound, it plays the message “Batt low, Wired Zone Open, Wireless Sensor
Number, etc”
Each Telephone number can be programmed to dial from 1 to 15 times.
For further details refer the headings ”Telephone Numbers Entry” + “Telephone Number Redial Times” +
“Telephone Number Display - ON / OFF”
Battery (Rechargeable) In-built Li rechargeable batteries for backup lasting up to 15 hours. Can be extended by
connecting optional BAS-PS (Power Supply with 12V 7AH Maintenance Free Battery).
Battery Low warning –of Main Unit
When the in-built Batteries of the Main Unit goes low & the SYSTEM is in ARMED condition, it will dial the pre-fed
Telephone number to inform the user with a Voice Message “Battery is Low”. It is possible to Listen-in and Disarm
the system through Telephone.
In case the system is DISARMED then display will show “Main Batt is low” & it will give a beep every 15 secs. In
this condition, the display back light keeps getting ON for 10 secs and then OFF for 10 secs.
Note: When Battery goes low and the system is ARMED, intrusion will not work.
Battery Low warning –of Wireless Magnetic / Vibration Sensors (MSW, VSW, VSW-T, PIRW, PIRW-T)
When the cell of any of the wireless Magnetic / Vibration Sensors goes low & the system is in ARMED condition,
it will dial the pre-fed Telephone number to inform the user with a Voice Message “Battery is Low + ID Number”.
The user can Disarm the system & can also Listen-in.
When a new Cell is restored in the Sensor, the system registers that the sensor is now operative.

When the cell of any of the wireless Magnetic / Vibration Sensors goes low & the system is in DISARMED
condition, the display gives a message and the display back light keeps getting ON for 10 secs and then OFF for
10 secs. During this condition, the system also gives a mild beep every 15 secs.
Note: However, SMS message is not to be relied upon and low battery LED indication on the sensor should be
checked periodically.
Capacity: Can connect to 75 Wireless Sensors
: Has 8 Wired zones & each Zone can connect to unlimited Wired Sensors
The system can work with up to 75 Wireless Sensors (including Wireless Remotes & Signal Repeaters) and any
number of Wired Sensors as long as the total resistance of the Sensors and the wires is less than 200 Ohms.
CMS (Central Monitoring Station) Services
With this feature, all or selected events are logged with a Central Monitoring Station maintained by the Copper
Connections Pvt Ltd. In the event of any intrusion, the attendant at CMS will take necessary action (as desired by
the user). Also in the event of battery of the Main Unit or compatible wireless sensors going low, the CMS get
notified and reminds the user. The CMS can also keep the record of events related to ARMING and DISARMING
of the system. This facility can be availed from Copper Connections Pvt Ltd on annual charges basis.
Display of the Zone / Sensor during intrusion in order to identify the area of intrusion.
The system displays the Wired Zone Number / Wireless Sensor number that is open.
For further details, refer the heading “Display explanations” – sub heading “During Intrusion”
Note: The system also informs the user through Telephone line, the Wireless Sensor number that has activated.
Refer “Voice Messages” heading given below.
Electrical Lights ON during Intrusion (Optional)
Selected Light load (not exceeding 200Watts) can be connected to it which gets ON whenever there is an
intrusion.
Listen-In / Talk-In
User can make a Telephone call from anywhere and listen to the noise near the System or can even talk through
the main unit. The same is true in case of intrusion as well.
Multilevel Passwords
The system has 1 Master & 5 User Passwords
Master Password can do all operations and programming as well. User level Passwords can only ARM or
DISARM the system. The History records would show which Password had ARMED / DISARMED the system.
Remote Monitoring –Whenever user wants or during Intrusion.
User can make a Telephone call from anywhere and perform the following:
Listen to the voices near the equipment or talk through it.
ARM or DISARM the system.
Set Siren ON / OFF
Listen to the Wired Zone / Wireless Sensors that are open
The same can be done during Intrusion.
For further details, refer the heading “Remote monitoring through Telephone line” & “Remote monitoring during
Intrusion”
Record of History of last 100 events with date & time stamping, to check the history of various operations.
For further details, refer the heading “Record of History”
Siren - Built in
One Siren comes built into the system with option to connect an external Siren.
More than one External Sirens can be provided by using “BAS-PS” power supply.
Refer the main heading = Installation & sub heading = Connector “Siren” for External Siren
To disable the Siren sound during Intrusion, refer the heading “Siren ON or OFF “
Signal Strength Display of GSM
User can check the strength of GSM signals received at the location where the system is installed. This helps in
locating suitable place of installation. Moreover the system cannot be ARMED when the signal strength is below
level 15.
Signal Repeaters (Optional)
They are used for increasing the operating distance of Wireless Sensors from the Main Unit. It doesn’t increase
the range of Wireless Flashing Siren. For further details, refer the heading “Signal Repeater – Wireless”
Silent Panic
User has the option to press “Panic” or “Silent Panic” keys from Remote / Main Unit. In case of “Panic”, the
system activates the Siren as well as dial out on Tel Line. In case of Silent PANIC, the system only dials out on
Tel Line.
Silent ARM
When the System is ARMED from the main unit, there is no Key Tone / Voice command. This helps the user to
ARM the system without drawing unwanted attention.
SIM Absent Alarm
When the system is switched ON it checks for the presence of SIM card. If SIM card is not present, the system
will give appropriate message for the same and beeps will long intervals. In this condition the user cannot ARM
the system.
SIM Balance Checking & various Programming through SMS
From Main Panel
Press 0 # - Enter the Balance Enquiry Codes of Service Provider (*123# in case of Airtel) –Press #.
Balance amount will be displayed.

Press “Quick Exit” to exit.
Through SMS
Through registered Mobile Numbers, user can send SMS to the SIM installed in BAS and get Reply with
balance. Similarly various Programming can be done through SMS with Password. Refer heading “SMS Text
for various programming”
Tamper Alert Main Unit
The main unit has in built tamper switch.
Whether the system is ARMED or DISARMED, if the main unit is removed from its bracket, the system will
consider it to be an intrusion. It will sound the siren & dial out the telephone numbers.
Whenever the system is hanged on the wall bracket, it is registered. Thereafter, when the system is removed
from the bracket it senses it as intrusion. In case, it is not hanged on the bracket then it does not consider it.
Tamper Alert in case of Vibration Sensors (VSW-T) / PIR Sensors (PIRW-T)
If VSW-T / PIRW-T are installed with the system, it will alert the user in case of Tampering of these sensors,
as explained below.
Whenever VSW-T or PIRW-T are Tampered, the system will dial out and give intrusion message with ID of the
Sensor. If the system was DISARMED at the time of Tamper, it will give mild beeps from the main unit. In case
system was ARMED at the time of Tamper, it will sound siren as in case of Intrusion.
Traitor Alert
One or all Wired Zone or Wireless Sensors can be configured for “Traitor Alert” feature. Whenever any of these
Sensors is open in DISARM mode, the system will give mild beeps thereby alerting to the user about the doors
(used by servants, Maids etc) being open. The mild beep doesn’t disturb the user yet keeps him/her alert. The
Sensor numbers that are open, are displayed on the main unit.
For programming this feature, refer “Wired Zones –Operating Mode” + “Wireless Sensor – Operating Mode”.
Voice messages in various operations. The system gives voice message prompts:
-When system is ARMED, DISARMED, during various programming modes, etc.
-When Battery goes low of the main unit in ARMED mode, the system dials Telephone Number and gives
voice message = Zone 99 Battery Low
-When Battery goes low of any of the wireless Magnetic / Vibration Sensor in ARMED mode, the system dials
Telephone Number and gives voice message = Wireless Sensor + <ID no> + Battery Low
-When system is ARMED and intrusion takes place, the systems dials out and plays the Siren sound
(message recorded by the user-Optional) + the Wireless Sensor Number or the Wired Zone Number.
Refer “Voice Message Recording for playing on Telephone calls during Intrusion”
The message played would be:
Siren Sound / User Recorded message + Wired Zone / Wireless Sensor + Zone/ID Number
Wireless Keyboard (Optional)
One or more Wireless Keyboards can be attached to this unit. Each Key Board can do limited Programming
of the system. They can also ARM / DISARM the system. They also work as Wireless Siren. Each Keyboard has
its own Password.
Wireless Remotes
One Remote is included with the system but more of them can be used.
It has functions of Panic Alarm, Remote ARM/DISARM, Remote BYPASS ARM.
For further details, refer the heading “Wireless Sensors, Remotes & Panic Keys Registering/Deletion / Deletion”
Wireless Siren (Optional)
Wireless Sirens can be connected at locations where wiring is a problem.
For further details, refer the heading “Wireless Siren Registering”
Wireless Magnetic Sensor Battery Save Feature
Wireless Magnetic Sensors with Battery save switch can be optionally installed on doors that are frequently
opened / closed during the DISARM status. This extends the cell life of the sensor. During DISARM status, the
sensor switch should be kept in OFF position and before ARMING the system, it should be shifted to ON
position.
Operation:- When the system is DISARMED and the switch of the Sensor is not switched to OFF position, the
system will give short beep at long intervals and its display will show “Please Switch OFF WL:ID
Type: MS+SW”.
- If system is being ARMED while the sensor switch is in OFF position, the display will show “Please
switch ON WL:ID Type: MS+SW” and Siren will sound at long intervals.
- If Sensor switch is shifted to OFF position when the system is in ARMED condition, intrusion will
take place.
Programming: Refer heading “Wireless Sensors, Remotes & Panic Keys Registering/Deletion”
Wrong Password Entry Alarm
While DISARMING the system, if anyone enters wrong Password 3 times consecutively, the system will sound
siren and dial out as is the case in Intrusion.
In this case the user will get message on his Telephone call as “Intrusion from 99”. 99 is the ID of Main Unit.
.Installation .
This Burglar Alarm System is supplied with following items:
1. Main Unit with built-in Siren & Rechargeable Batteries - 1 No
2. Wireless Remote - 1 No
3. Power Supply Adapter (12V 500mA DC) - 1 No

A GSM SIM card is to be provided by the user.
Notes on Installation
-Wireless Sensors can be placed within 300 ft distance from the Main Unit if there is no obstruction in between. They
have to be registered in the Main Unit as explained under the heading “Wireless Sensors, Remotes & Panic Keys
Registering/Deletion ”.
The distance between the Main Unit and Wireless sensors would be maximum when there is minimum interference
of concrete walls, electric appliances etc.
-Install the Main Unit in an open & ventilated area so that the signals from different Wireless Sensors are received
properly by the Main Unit. It should be installed at least 0.5 meters from ground. It should be ensured that no liquid
spills over it.
-Do not install the Main Unit near high frequency electric appliance in order to avoid interference of electromagnetic
waves.
Wireless Sensor’s range checking method
Put a wireless Sensor in Traitor mode.
Take the Sensor to maximum distance from BAS and trigger the sensor.
If mild beeps with sensor ID number is shown on BAS display that means the sensor can be installed up to that
distance.
Connections
- There are 2 Connectors provided at the back side of the main unit. One connector is of 10 pins and the other of 20
pins. Their corresponding female connectors with wires are also provided with the system.
- The wires from the female connectors are to be connected as per the tables given below:
20 Pin Connector
Wire Color
To be connected to
Red
Adapter 12V DC +Ve Output.
Violet
External Siren +Ve Wire.
Connect a 9 - 12V DC Type Siren (Max Wattage
300mA). If more than one external Siren is to be
used than install BAS-PS and do the connections as
per the BAS-PS Manual.
Red with Black Sleeving
Auxillary +Ve 8.5 V DC Supply for Sensors.
Sensors that operate 8.5V DC can be connected to
this connector & GND provided the total current
drawn is less than 250mA.
Orange with Black
Sleeving
External PB (Peizo Buzzer) +Ve wire.
Brown
NC Type Wired Zone no 1 wire.
Pink
NC Type Wired Zone no 2 wire.
Orange
NC Type Wired Zone no 3 wire.
Yellow
NC Type Wired Zone no 4 wire.
Green
NC Type Wired Zone no 5 wire.
Blue
NC Type Wired Zone no 6 wire.
White
NC Type Wired Zone no 7 wire.
Grey
NC Type Wired Zone no 8 wire.
Black –3 Wires
GND –Ve of 12V DC Adapter &
- Ve of Auxillary Output &
- Ve of External Peizo Buzzer &
- Ve of External Siren &
One end of all the Wired Zones wires
10 Pin Connector for “NO Type” Sensors
Wire Color
To be connected to
Brown
NO Type Wired Zone no 1 wire
Red
NO Type Wired Zone no 2 wire
Orange
NO Type Wired Zone no 3 wire
Yellow
NO Type Wired Zone no 4 wire
Green
NO Type Wired Zone no 5 wire
Blue
NO Type Wired Zone no 6 wire
White
NO Type Wired Zone no 7 wire
Grey
NO Type Wired Zone no 8 wire
Black
The other end of all the NO Type Wired Zones Wires

There are 2 type of Wired Sensors –Normally Closed Type and Normally Open Type.
They are respectively explained below:
Normally Closed Type
If more than one is to be connected in one Zone then they are connected in Series. Their contact points remain
Closed in ARMED condition. The contact gets Open when the sensor senses intrusion.
Connect all the “Normally Closed Type Wired Sensors” in series and terminate on any of the “NC Type” Zone
wires of the Main Unit.
Any number of Wired Sensors can be connected as long as the total resistance of the Sensors and the wires is
less than 200 Ohms.
Normally Open Type
If more than one is to be connected in one Zone then they are connected in parallel. Their contact points remain
Open in ARMED condition. The contact gets closed when the sensor senses intrusion. Connect all the “Normally
Open Type Wired Sensors” in parallel and terminate on any of the “NO Type” Zone wires of the Main Unit.
Note: Each Zone can be connected to one or more Sensors provided they are same type i.e., They should
either be Normally Closed Type or Normally Open Type. However, different Zones can be used for different type
of Sensors.
Wireless Remote & Wireless Sensors should be registered in the Main Unit as described under the heading
“Wireless Sensors, Remotes & Panic Keys Registering/Deletion”.
.Power On Procedure .
After doing all the connections, remove the Main Unit from its wall bracket.
Switch ON the 220V AC supply to the adapter.
Now hang the main unit back on its wall bracket.
The display show:
“Initialising GSM …..” - In case of any error the display will show “Initialisation Error”
“Initialising BOARD ….”
.Front Panel LED Indications .
There are 2 LEDs on the front panel marked as ARMED and READY.
ARMED LED glows in red color and READY in blue color.
Following table illustrates the various conditions:
LED
Status
Message
ARMED
OFF
System is DISARMED
ON
System is ARMED
Blinking
System is in Intrusion mode & Tel Number (if
entered) is being dialed by the system.
Ready
ON
System is running on AC mains
Blinking
System is running on battery
Low Battery indication
When the in-built Batteries of the Main Unit get low, “Low Battery” appears in the display of the Main Unit.
Sensor1
Sensor 2
Sensor 3
Sensor 1 Sensor 2 Sensor 3
Connected to
the “NC”
Type Zone
Wires &
Black wire of
20 Pin
Connector
Connected to
the “NO”
Type Zone
Wires &
Black Wire of
10 Pin
Connector

.Sound Indications .
-During Intrusion the Siren sounds to its maximum power
-Whenever the system fails to get ARMED for any reason, the Siren sounds for a very short time with a long
gap in between. This continues until DISARMED.
-Whenever a Sensor registered in TRAITOR mode is open, the speaker of the system would emit a low beep
-In case of Main System battery low, the speaker of the system would emit a low beep. This would also
happen if battery of any of the compatible Sensor gets low.
.Display explanations .
Normal Standby mode
Display =
Where, HH:MM:SS = Current time in 24 hrs format (HH= Hours, MM= Minutes, SS= Seconds)
DAY = Today’s day i.e., Mon, Tues, Wed, etc
Srn = It shows that the system is programmed to sound the Siren in case of Intrusion.
If this “Srn” symbol doesn’t appear then it means the system is not programmed to sound the
siren.
DD/MM/YY = Current day (DD= Date, MM= Month, YY= Year)
DDDDDD = Armed –means system is Armed
= Disarm –means system is Disarmed
= ByPass –means system is Armed in By Pass Mode
While Arming the system
Display =
Where, W:X = Wired Zone numbers 1 to 8 in which Sensor is open.
WL:AA,BB,CC,DD = Wireless Sensor numbers from 01 to 75 that are Open.
During Intrusion
Display =
ZZZZ = WL:01 to WL:98 in case of intrusion from wireless sensor
W1 to W8 in case of intrusion from wired sensor
TYPE = PAN, PIR, MS, VBR, Gas, SMK or Misc in case of intrusion from wired sensor
= “Remote” in case Panic key is pressed from the Wireless Remote
= “Keypad” in case Panic key is pressed from the main unit.
Intrus = It means Intrusion
TTTTTTTTTT = The Telephone number being dialed by the system
When battery goes low of any of the wireless Magnetic / Vibration sensor
Where, X= 1-9 (Total number of Sensors that are having low battery)
YYY= Type of Wireless Sensor (PAN, PIR, MS, VBR, Gas,
SMK or Misc)
CC= 01 to 75 Wireless Magnetic / Vibration Sensor number
When a Sensor is Open in DISARMED mode
Display =
Where, W:X = Wired Zone numbers 1 to 8 in which Sensor is open.
WL:AA,BB,CC,DD = Wireless Sensor numbers from 01 to 75 that are Open.
Note: During this display the back light is kept off (in order to save battery, in case AC mains is not available).
To view the display with back light, press # key.
.Always ARMED Sensors .
Any Sensor whether Wireless or Wired can be made to function 24 hours i.e., it would trigger intrusion in ARMED
mode as well as DISARMED mode.
Programming:
:In case of Wireless Sensor, make its MODE = Always ARMED as explained under the heading “Wireless
Sensor –Operating Mode”.
:In case of wired sensor, its Zone is to be programmed as MODE = Always ARMED as explained under the
HH:MM:SS DAY Srn
DD/MM/YY DDDDDD
SNSR OPEN W:X,Y,
WL:AA,BB,CC,DD,
ZZZZ TYPE Intrus
TTTTTTTTTT
X Sensr Batt low
Type: YYYY WL:CC
SNSR OPEN W:X,Y,
WL:AA,BB,CC,DD,

heading “Wired Sensor – Operating Mode”
Operation:Whenever, the Sensor is triggered irrespective of the system being in ARMED or DISARMED condition, the
Siren will starts hooting and the system will dial out the Telephone numbers
.Arm .
You can ARM the system and leave the Remote inside the premises, if required. In this case close all the sensors,
ARM the system. Now leave the premises within 10 secs and close the door. This 10 secs can be decreased or
increased up to 60 secs. Refer heading “Delay to ARM” for changing this time.
While moving out of the premises, ARM the system by any of the following method:
Press “QUICK EXIT” & Key together on the Main Unit + Enter Master Password 234) + #
or
Press the “ARM” on the Wireless Remote.
Caution: While Arming the system from Remote, the system gives 2 Loud Confirmation tones. If 2 tones are
not heard, arm it again. Keep pressing the ARM key until you are sure of the 2 tones.
In ARM state, the indicator on the main unit would glow RED.
Now, whenever any sensor is triggered, the system will dial the preset telephone number and activate the siren after 10
secs.
Note:In case of PANIC button being pressed, there is no delay.
.ARM Bypass .
In this mode, one or more Zones can be programmed to remain Disarmed while rest of the Zones get ARMED. This
feature is useful where some part of the building occupied by servants may be left Disarmed while keeping the rest of
the building Armed.
Procedure to activate the system in Bypass mode is explained below.
If system is Armed normally through, then even the Bypass zones get Armed.
To program a Zone as a Bypass Zone refer “Wireless Sensor –Operating Mode” & “Wired Zones – Operating Mode”.
To ARM the system in Bypass mode:
Press “Back Space” and “7” together on the Main Unit.
Enter Master Password ”1234” + #
or
Press the “ARM Bypass” Key on the Wireless Remote.
Caution: While Bypass Arming the system, the system gives 2 Loud Confirmation tones. If 2 tones are not heard, arm
it again. Keep pressing the Bypass ARM key until you are sure of the 2 tones.
.ARM / DISARM Confirmation Sounds control .
Whenever the system is ARMED / DISARMED there are 2 Sound indications:
Siren Sound Confirmation
Voice Command Confirmation
Both these can be switched ON/OFF as explained below.
Siren Sound Confirmation
When the system is ARMED or DISARMED from Wireless Remote or the Main Unit, there is a confirmation sound from
the Siren. This Sound can be set as ON or OFF.
Press SET
Enter Master Password (1234) + #
Keep Pressing 2 to select “Conf Tone”
Press #
Press key “UP”or “DOWN”to select “OFF or ON for this feature
Press # + Quick Exit
Voice Command Confirmation
When the system is ARMED or DISARMED from Wireless Remote, there is a confirmation Voice Command which can
be set as ON or OFF.
Programming:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Rmt Voice Cnf”
Press #
Press key “UP”or “DOWN”to select ON or OFF
Press # + Quick Exit
If it is set at OFF, the Voice Command will not appear while Arming / Disarming from the wireless Remote.
Note: This cannot be switched OFF while Arming / Disarming from the Main Unit.
.Auto Arm / Disarm Time + Holidays .
The system can be programmed to ARM and DISARM automatically up to 3 times a day.
There are 3 groups of time and each group has a time of ARM and DISARM.
Programming:
Press “SET”

Enter Master Password (1234) + #
Keep Pressing 2 to select “Auto ARM/DISARM”
Press #
Press 0 for Sunday
1 for Monday
2 for Tuesday
3 for Wednesday
4 for Thursday
5 for Friday
6 for Saturday
7 for All Days
Press “UP” or DOWN” to select Grp 1, Grp 2 or Grp 3.
Press 4 to make Grp = ON / OFF
BACK SPACE + HH + MM + # + hh + mm + # + Quick Exit
Where, HH = ARM Time: Hours in 24 hrs mode & MM = Minutes
hh = DISARM Time: Hours in 24 hrs mode & mm = Minutes
Default: In default the system is not in Auto Arm / Disarm mode.
Note: To operate the system with separate Day wise timings, keep all the 3 Groups of “All Days” = OFF.
:User can use all the 3 time groups by entering the same DISARM time but keeping the ARM time different or
Vice Versa. Example:If system is to be operated with following changing time for all days:
First ARM Time = 11 PM
DISARM Time = 9 AM
Second ARM Time = 1PM
DISARM Time = 2PM
Then programming would be:
“SET”
Master Password (1234) + #
Keep Pressing 2 to select “Auto ARM/DISARM”
Press #
Press 7
Press “UP” or DOWN” & select Grp 1 + 4
Back Space
2300 + #
0900 + #
Press “UP” Key (Grp 2 will appear) + 4
Back Space
1300 + #
1400 + #
Quick Exit
:To ARM the system for the whole day, enter ARM Time = 0000 and DISARM time = 2359
:If all the 3 Time Groups of a day are = OFF then the previous day’s last status (Armed / Disarmed) shall continue.
: Example of Day wise operation
If system is to be operated with following time:
From Monday to Saturday
ARM Time = 10 PM
DISARM Time = 9 AM
On Sunday
All day ARM
i.e., ARM Time = 0000 Hours
DISARM Time = 2359 Hours
The programming would be:
“SET” +Master Password (1234) + #
Keep Pressing 2 to select “Auto ARM/DISARM”
Press #
Select the Day 1 (for Monday)
Press “UP” or DOWN” & select Grp 1 + 4 + Back Space
2200 + #
0900 + #
Quick Exit
Repeat the above for Tuesday + Wednesday + Thursday + Friday + Saturday
Now for Sunday all the 3 Time Groups should be = OFF
:If the system is working in Auto ARM / DISARM mode & the Battery of the main unit goes low then the system will
not ARM. At the time of ARMING it will dial out & give message =Zone 99 Battery Low. It will not sound the siren
in this case. The same would happen if any of the Sensor is Open at the time of Auto ARMING.
The message given would be = Wired / Wireless Sensor + Zone / ID number.
Holidays entry
Up to 10 holidays can be entered in the system. On those days the system will continue in the previous day’s status.
Entry of day:
Press “SET”

Enter Master Password (1234) + #
Keep Pressing 2 to select “Holidays”
Press #
Press “Up Arrow” key to select day 1, 2, 3, ……
Press “#”
Enter the date + Month + Year (All in 2 digits format)
Here, “Back Space” key can be used to edit the entered digits.
Press “#” to confirm
Press “Quick Exit” to exit
Deletion of day:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Holidays”
Press #
Press “Up Arrow” key to select day 1, 2, 3, ……
Press “Back Space”
Press “#” to confirm deletion
Press “Quick Exit” to exit
Default:No holidays.
Note:If wrong date is entered, system will display “Invalid Date”.
: Today’s date or previous date is considered wrong by the system
.Battery Mode - Power Switch Off .
When AC mains is not present, the system shifts to the battery mode and keeps the system running.
If it is required to switch OFF the system when running in Battery mode, do the following programming.
Procedure: Press BACK SPACE
Enter Master Password (1234) + # + 2 + #
System will switch OFF.
Note: The system gets ON automatically when the mains AC is restored.
:The system cannot be switched OFF if mains AC is connected to it.
:The system has built-in rechargeable Li batteries. If longer back up is required then additional rechargeable 12V
7AH battery can be connected with an Optional Adapter having charger.
.CMS (Central Monitoring Station) .
With this feature, all or selected events are logged with a Central Monitoring Station maintained by Copper
Connections Pvt Ltd. In the event of any intrusion, the attendant at CMS will take necessary action (as desired by
the user). This facility can be availed from Copper Connections Pvt Ltd on annual charges
basis.
Programming for activation of the feature:
The system is to be given the CMS telephone number through programming.
To Enable the CMS feature:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “CMS Settings”
Press #
Press 2
Press 6 and select CMS = Enable or Disable. Press 6 again to alter Enable / Disable.
Press #
Press “Quick Exit”
To Enter Telephone Number of the CMS
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “CMS Settings”
Press #
Press 1
Press “Back Space”
Enter the Telephone Number
Press #
Press “Quick Exit”
.Date / Time Setting .
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Set Date”
Press #
Press YY + # + MM + # + DD + # + HH + # + MT + # + d + # + Quick Exit
Where, YY= Year
MM= Month
DD= Date

HH= Hours in 24 Hours mode.
MT= Minutes
d= Week Day from 0 to 6 (0= Sunday & 6= Saturday)
.Disarm .
While entering the premises, DISARM the system with any of the following methods within 10 secs of entering the
premises:
Press “SET” and 1 together on the Main Unit + Enter Master Password (1234) + #
Note:If the Display shows WAIT then wait till that disappears & then Press SET+1.
or
Press the “DISARM” Key on the Wireless Remote.
While Disarming the system, it gives one single loud tone.
.Delay to ARM .
This is the time delay after system takes action on getting intrusion from any Sensor. This delay also helps in Arming
the system while leaving the premises. The user can ARM the system while being inside the premises and then leave
within this time:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Arm Delay”
Press #
Back Space
Enter Time delay in seconds in 2 digits (00 - 60 Sec.)
Press # + Quick Exit
Default:10 secs.
.Panic Key .
The Wireless Remote supplied with the system has a Key marked as “PANIC”.
After 3 secs of pressing this key, the Siren will start hooting and the system will start dialing the Telephone Numbers.
This would happen whether the System is in ARMED mode or DISARMED mode.
If desired, more Panic Switches can be registered in the system. Following are the type of Switches that can be added:
Wireless Remotes (one is supplied with the system and more can be registered)
Wired Panic Switches
Programming:
:In case of Wireless Remote, add Wireless Remote as explained under the Heading “Wireless Sensors, Remotes
& Panic Keys Registering/Deletion ”
:In case of Wired Panic Switches, its Zone is to be programmed as MODE = Always ARMED as explained under
the heading “Wired Sensor – Operating Mode”
Operation:Panic activation from the Remote.
Press “PANIC” Key.
Siren starts hooting and the system dials out on the Telephone line.
:Panic activation from the Main Unit
Press “SENSOR” Key & “4” Key together.
Note:In case of PANIC code entry from the main unit, there is no KEY PAD sound.
.Panic Key –Silent .
User has the option to press “Panic” or “Silent Panic” keys from Remote / Main Unit.
In case of “Panic”, the system activates the Siren as well as dial out on Tel Line.
In case of Silent PANIC, the system only dials out on Tel Line.
To activate “Silent Panic” from Main, press Key 5 + 6 together.
To activate “Silent Panic” from Remote, press Panic Key & then press “ARM BY PASS” key within 3 secs. If “ARM
BYPASS” key is not pressed within 3 secs then the system will activate as Normal PANIC.
Note:Silent Panic is available from Main Unit & Remote Units but not in Wired / Wireless Panic Switches
:In case of SILENT PANIC code entry from the main unit, there is no KEY PAD sound.
.Passwords .
The system has 7 Passwords.
1 Password is a “Master Password” which can do all the programing & all the operations.
5 Passwords are “User Passwords”. They can only ARM, DISARM or BYPASS ARM the system.
1 Password is an “Emergency Password” which starts dialing to stored telephone numbers without siren sound.
All Passwords except Emergency Password can be changed by their respective Passwords. One User Password
cannot change other’s Password.
But Master Password can change User’s Passwords as well as his own.
The default Master Password = 1234
Emergency Password = 0000
In default there is no User Password. Master Password has to enter the User Passwords.
System doesn’t accept 0000 as User or Master Password.
All programming requires Master password.

All programming are to be done in DISARM mode of the system.
After entering the Master Password for the first time, the system remains in Programming mode for 60 secs.
So, in case more than one programming is to be done, the system will not ask for Password again within 60 seconds of
the first programming.
Hence in such cases, the steps of “Enter Password + #” would get void in all the programming steps.
The Master Passwords can be changed as described below:
Press “SET”
Enter Old Password + #
Keep Pressing 2 to select “Password Chng”
Press #
Enter New 4 digit Password + # + Quick Exit
Alternately, Master Password can change User Passwords also as explained below:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Password Chng”
Press #
Press to select the desired User Password to be changed
Enter New 4 digit User Password + # + Quick Exit
Note: The Master Password can change User’s Password but cannot view their Passwords.
: After entering any Password if another Password is to be used before elapse of 60 seconds, press
“Quick Exit” twice.
:While changing Password, if the Password being entered is used by someone, it will display “Invalid Password”.
Same is true in case Password being entered is “0000”.
.Password Operation On / Off .
.
This feature allows ARMING of the system with or without Master Password.
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Password Optn”
Press #
Press key “UP”or “DOWN”to select OFF or ON for this feature
Press # + Quick Exit
.Record of History .
The system keeps a record of last 100 events of ARM, DISARM and Intrusions with date and time of events.
To View the records:
Press (History).
Enter Master Password (1234) + #
Press “UP” or DOWN” to select a particular record.
To Clear the records:
Press (History).
Enter Master Password (1234) + # + Back Space + Master Password (1234) + #
Note: After 100 records, the very first record gets deleted to record the 101st event.
Explanation of the Display on the main unit:
Display Meaning
SN = 00 to 99 denoting Serial Number of the History
ZZ = Wired Zone Number / Wireless Sensor number
01 to 75 in case of Wireless Sensor
98 in case of Operations through Telephone Line
99 in case of “Main Unit”
W1 to W8 in case of Wired Zones
DDDDDD= It either of the following action:
= Armed - means the system was armed at that time.
If, ZZ=99 then the system was Armed from
the main unit.
= Disarm - means the system was disarmed at that time
= Intrus –means intrusion from the displayed wired Zone or
wireless Sensor
= Panic –means Panic key was pressed
= Batlow –means battery is low of the displayed wireless
Sensor or the main unit in case of ZZ=99
= Bypass –means the system was Armed in Bypass mode
= PwWrng –Wrong Password entered 3 times consecutively.
SN ZZ DDDDDD TTT
Date Time

= Sl Pan –Silent Panic
= A.Fail (It means Auto ARM failed due to ZZ Sensor being Open. If ZZ= 00 that would
mean that Auto ARM failed because of some condition like No Telephone Number
stored, SIM Not connected, etc)
= Faulty (HHW is not working)
TTT = Tel –means Telephone numbers were dialed by the system
= Blank means no telephone number was dialed by the system
= P:X Where X = 1, 2, 3, 4, 5, M
P:1 = Operated by User Number 1
P:2 = Operated by User Number 2
P:3 = Operated by User Number 3
P:4 = Operated by User Number 4
P:5 = Operated by User Number 5
P:M = Operated by Master User
P: = Operated from Main Unit without Password
(This will happen the System is programmed with
Password Option = OFF)
T:.= Operated through Telephone Line
Date = Date of the activity
Time = Time of the activity
.Remote monitoring through Telephone line .
The system can be monitored through Telephone line from anywhere in the world. One has to dial the Tel number that
is connected to the System. The system picks up the call after a set number of rings.
Voice message “Enter password” will be heard.
After the message is over, dial Master Password (1234) #
If password entered is wrong, a message “Wrong Password” will be heard.
If wrong Password is entered 3 times then intrusion will be caused by the system after 5 minutes.
If correct password is entered, a voice message “Welcome” will be heard.
Press “1” to Listen / talk through the Main Unit.
Now the system will remain in Listen In / Talk mode for 4 minutes.
To extend the time, dial 1. Another 4 minutes will be extended from the time of dialing 1.
Press “2” to activate the siren
Press “3” to de-active the siren
Press “4”to ARM the system
Press “5”to DISARM
Press “7”to Force Arm the system, which allows arming of the system even if a sensor is left open.
Press “#” to end call
Number of rings after which the system picks up the call for remote monitoring
Programming:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “No. of Rings”
Press #
Press 0 to 9 + #
Where, 0 to 9 = 1 to 9 is the Number of Rings (0 is equal to 1).
Note:Default value = 4
.Remote monitoring during intrusion .
On receiving the call, the receiver will hear siren sound (10 seconds recorded message- optional).
Press
Press ”1” to Listen / talk through the Main Unit.
If a code is not dialed within 20 seconds, the call will disconnect and the system will then resume dialing.
Press 2 to activate Siren
Press 3 to deactivate Siren
Press 4 to ARM the system
Press 5 to DISARM
Press 6 to Listen to the Zone Number / Sensor Number from where intrusion has taken place.
Press # to End Call
Note: The Telephone numbers are dialed by the system as per the sequence number in which they are entered.
:The system keeps dialing Telephone numbers unless any of the called party DISARMS by dialing 5.
.Resetting to Factory Settings .
Some of the programming of the system (listed below) can be reset to the default values:
Operation through Master Password = ON / OFF (Default = ON)
Time delay to activate Siren after intrusion (Default = 10)
Confirmation Sound ON/OFF, while activating from Wireless Remote (Default = ON)
Siren Hooting Time (Default = 1 minute)

Ringing time of an incoming call, after which the system picks up the call for remote Monitoring (Default = 6 Rings)
Telephone Numbers = Clean.
Time delay to ARM (Default = 00)
Auto ARM/ DISARM (Default = Manual) OFF
Procedure: Press BACK SPACE + Enter Master Password (1234) + # 11 # #
(2 Beeps will indicate that the system has been reset)
.Resetting SIM .
In case System doesn’t get ARMED and shows “No Network” then reset the SIM using the following procedure.
Procedure: Press BACK SPACE + Enter Master Password (1234) + # + 1 + 2
(2 Beeps will indicate that the SIM has been reset)
SIM Alarm Enable / Disable .
The system has a feature to display ‘SIM Absent’ when no SIM card is inserted.
This feature can be Enabled or Disable from the Keypad.
Programming:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “SIM Alarm”
Press ‘Mode’ key to select ‘Enable/ Disable’
Press # + Quick Exit
.SIM Balance Checking .
From Main Panel
To know the balance amount in a prepaid SIM card installed in the BAS, following is the procedure:
Press 0 # - Enter the Balance Enquiry Codes of Service Provider (*123# in case of Airtel) –Press #.
Balance amount will be displayed.
Press “Quick Exit” to exit.
Through SMS
Registered Mobile Numbers can send following SMS to the SIM installed in the BAS and get reply of the SIM balance:
SIMBAL CCCCC . . .
Where, CCCCC . . . . . = The Code to check SIM balance (given by the service provider)
Example: In case of AIRTEL, SIMBAL 123#
.Siren Hooting time .
This is the time for which the Siren will keep hooting during intrusion.
If the time is kept = 00 then Siren will not sound at all and the system will silently dial out on telephone line.
Programming:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Siren Time”
Press #
Press 00 to 99 + # + Quick Exit
Where, 00 to 99 = Hooting Time in Minutes of the Siren
Note:When the Siren Hooting Time= 00, the “Srn” display on the right hand side corner of the Main Unit LCD Display
will not be there.
:The default value is 30 Minutes.
.Siren ON or OFF .
The Siren of the system can be disabled. Then the siren will not sound in case of intrusion however Telephone dialing
shall be done by the system, if enabled and telephone numbers are entered.
Siren cannot be disabled for the following conditions:
When any of the Wired Zone or wireless Sensor is open & system is being Armed.
Programming:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Siren ON/OFF”
Press #
Press Key “UP” or DOWN” to select ON / OFF
Press # + Quick Exit
Note:In default it is = ON
.Siren Wireless or Flashing Siren-Wireless (FSW) Registering .
Press “SENSOR” key
Enter Master Password (1234) + #
Press 1
Keep Pressing 8 to select “Flashing Sirn”
Press #

Back Space + ABCDEFGH + # + Quick Exit
Each alphabet of ABCDEFGH = 0 or 1 depending on the shorting of the Pads below the IC U2 on the PCB of
Wireless Siren PCB. On the PCB these pads are marked as 12345678.
Each Pad can either be shorted or left open.
Open pads represent “1” and shorted pads represent “0”.
Note: At least one of the pad should be shorted.
Default value = 10111111 i.e., pad number 2 is shorted and all others are open.
So, the programming in default case would be:
Press “SENSOR” key
Enter Master Password (1234) + # + 1
Keep Pressing 2 to select “Flashing Sirn”
Press #
Back Space + 10111111 + # + Quick Exit
Note: Wireless Flashing Sirens work with 12V DC and not 9V.
: In one system, any number of Wireless Siren can be installed provided all of them are set in same PAD Shorting
and the main unit is programmed for that Shorting.
.Siren Wireless or Flashing Siren-Wireless with Tamper Protection (FSW-T) Registering .
There are following 3 parts of FSW that need to be registered with the Burglar Alarm System Main Unit:
Registering of Flashing Siren
Press “SENSOR” key
Enter Master Password (1234) + #
Press 1
Keep Pressing 2 to select “Flashing Sirn”
Press #
Back Space + ABCDEFGH + # + Quick Exit
Each alphabet of ABCDEFGH = 0 or 1 depending on the shorting of the Pads below the IC U2 on the PCB of
Wireless Siren PCB.
The 8 shorting pads represent ABCDEFGH starting from the Pad where Arrow is made.
Each Pad can either be shorted or left open.
Open pads represent “1” and shorted pads represent “0”.
Note: At least one of the pad should be shorted.
Default value = 10111111 i.e., pad number 2 is shorted and all others are open.
So, the programming in default case would be:
Enter Master Password (1234) + # + + 03 + # + Back Space + 10111111 + # + Quick Exit
Note: Wireless Flashing Sirens work with 12V DC and not 9V.
: In one system, any number of Wireless Siren can be installed provided all of them are set in same PAD Shorting
and the main unit is programmed for that Shorting.
Registering of Tamper Protection
Press “SENSOR” key
Enter Master Password (1234) + #
Press 1
Keep Pressing 2 to select “Tamper”
Press #
Dial 01 to 75 (ID number to be given to the Flashing Siren) + #
Now trigger the Wireless Circuit of the FSW (By taking away of the Magnet or by bring it close to the Wireless
Circuit)
Press #
Press “Quick Exit”
Note: Whenever FSW is Tampered with or any of its wire is cut, the Main Unit display will show its ID number and
Zone Name as “Tamper.”
:During the programming, the system auto cancels the operation if it doesn’t receive the input from Wireless
Sensor within 20 seconds.
Deletion of registration
To delete a FSW registration from the Main Unit:
Press “SENSOR” Key.
Enter Master Password + # + 2 + 2
Press “UP” or DOWN” to choose the ID you want to delete.
Press BACK SPACE + # + Quick Exit
Setting of Mode of Operation of FSW
Press “SENSOR” Key
Enter Master Password (1234) + # + 2 + 2
Press “UP” or DOWN” key to select the desired Wireless Sensor
Press MODE to choose any of the following modes of Tamper:
Mode
Functioning of the Siren
Disable
Do Not Select this Mode
Always ARMED
If this mode is selected then in case of
Tampering of Siren or wire cutting or removing

of Adapter/BS-PS, the system will dial out and
sound the internal siren of the unit & external
Sirens if connected, in ARMED as well as
DISARMED condition.
Press # + Quick Exit
Note: When the cell of FSW goes low & the system is in ARMED condition, it will dial the pre-fed Telephone number to
inform the user with a Voice Message “Battery is Low + ID Number”. The user can Disarm the system. When a
new Cell is restored in the Sensor, the system registers that the sensor is now operative.
In case system is in DISARMED condition, the display would give a message and the display back light keeps
getting ON for 10 secs and then OFF for 10 secs. During this condition, the system would also give a mild beep
every 15 secs.
.Signal Repeater –Wireless .
Put the Signal Repeater ON by sliding the Slide Switch on the TOP of the Signal Repeater. The Green LED marked as
“Power” will turn ON.
The Switch has 3 positions: Right position is for OFF. The middle & Left position are for ON and are same.
The Display will show digits 0 to 9 one by one and then the Display will turn OFF.
Now register the Signal Repeater in the Main Unit as described below:
Press “SENSOR”
Enter Master Password (1234) + #
Press 1
Keep Pressing 2 to select “Tamper”
Press #
Enter 2 Digit ID number (from 01 to 75)
Press #
Remove Magnet Unit of the Signal Repeater (In order to send Tamper signal)
(The Main Unit will give a double Beep indicating that the registration is complete. 5 short beams would
mean that the registration is not successful)
Press Quick Exit
Note: Number of Signal Repeaters can be registered and used for extending the range from one Signal Repeater to
another.
:Every Signal Repeater consumes one of the 75 Wireless Sensors capacity of the system.
:SW and FSW do not work through Signal Repeaters.
Deletion
This process deletes all the Signal Repeaters & Wireless Remotes connected to the system. If only one is to be
deleted then delete all the Remotes/Signal Repeaters and register the required ones again.
Press “SENSOR”
Enter Master Password (1234) + #
Press 2 + 2
Press Up or DOWN Key to select the Sensor ID that is to be deleted.
Press Back Space
Press # + Quick Exit
.Signal Strength test of GSM .
User can check the strength of GSM signals received at the location where the system is installed. This helps in
locating suitable place of installation.
The system cannot be ARMED when the signal strength is less than level 15. In that case the display will show “No
Network” or “Network Error”.
If Signal strength is between Level 15 and 18, system will dial out & also send SMS in case of intrusion but may accept
all DTMF digits dialed by the user. Above level 18, the system would work perfect for all features.
Procedure:
Press “5” Key
Enter Master Password (1234) + #
The display will show the following:
+CSQ: X,0
Where X= Signal Strength 0 to 31.
Press “Quick Exit” to Exit.
.SMS Text & Android Application for Various Programming .
Programming by SMS:
Following are the SMS Text message that need to be sent to the SIM installed in the system for various actions:
Action
Command
Description
1
Arm system
XXXX+ARM
The system will be ARMED
2
Disarm system
XXXX+DISARM
The system will be DISARMED
3
Bypass Arm system
XXXX+BYPASS
The system will be ARMED in BYPASS mode
4
System details - Short
XXXX+SYSTEM
System will send SMS giving following details:
System Status:ARMED or DISARMED
Power:On Mains / On Battery

Date:DD/MM/YY
Time:HH:MM in 24 Hours format
Tel:X (X= no of Tel Numbers stored)
Wired Zones Active:X (No of Wired Zones
that are Enabled out of 8 Wired Zones)
Wireless Sensor:X (No of Wireless Sensors
Registered, except Remotes)
Remote:X (No of Remotes registered)
5
System details –Detailed
XXXX+SYS DETAIL
System will send SMS giving following details:
System Status:ARMED or DISARMED
Power:On Mains / On Battery
W STAT:This shows the Modes in which 8
Wired Zones are Enabled. DS
means Disabled. NA= Normal ARM,
AA= Always ARM, TR= Traitor, BA=
By Pass,
WL Stat:This shows the ID, Type and Mode
of the registered wireless sensors.
MS= Magnetic Switch, VIBR=
Vibration Sensor, RMT= Remote,
PIR= Motion Sensor, TAMP=
Tamper Sensor, PAN= Panic,
HEAT= Heat Detector, SMK=
Smoke Detector, GAS = GAS
Detector, HHW= Heat and Humidity
Detector, BEAM= Beam Sensor,
WKBD= Wireless Key Board, M+S=
Magnetic Sensor with Switch
DS means Registered but Disabled.
NA= Normal ARM, AA= Always
ARM, TR= Traitor, BA=By Pass.
6
Registered telephone
number list
XXXX+TEL
All the registered Telephone numbers will be
listed.
7
Change Master Password
CHANGE PW XXXX YYYY
XXXX = old Master Password , YYYY = New Master
Password
8
SIM balance check
SIMBAL ccccc
ccccc = Service provider’s SIM balance code. E.g. for
Airtel , it is *123#. You will get a SMS stating the
balance in SIM of BAS.
9
Add telephone number
XXXX+ATELjk ttttttttt
j = Tel location from 1-6 , k = E for SMS commands
enable/ D for SMS commands disable , tttttttt =
telephone number (max 11 digits)
10
Delete telephone number
XXXX+DTELj
j = tel location from 1 –6
11
Set auto Arm/Disarm
XXXX+AUTOj aaaa dddd
j = group number (1 -3) , aaaa = arm time in 24hr
format , dddd= disarm time in 24hr format. This
setting will be applied for all the 7 days of the week.
12
Disable auto Arm/Disarm
XXXX+OFFAUTO
Auto ARM/DISARM will be disabled.
13
Delete all wireless sensors
XXXX+WLALLDEL
All Wireless Sensors will be deleted.
14
Delete specific wireless
sensor
XXXX+WLDEL nn
nn= wireless ID to delete.
15
Add wireless sensor
XXXX+WLADD nn y
nn=wireless ID, y = type of sensor. Refer table below
for values.
16
Change mode of specific
wireless sensor
XXXX+WLMOD nn y
nn = wireless ID , y = mode of sensor( 0=Normal Arm
, 1 = Disable, 2= arm bypass , 3 = always armed)
17
Disable all wired zones
XXXX+WRALLDIS
All Wired Zones will be disabled.
18
Set mode of specific wired
zone
XXXX+WRMOD n y
n = wired zone (1 to 8), y = mode of zone ( 0=Normal
Arm , 1 = Disable, 2= arm bypass , 3 = traitor mode, 4
= always armed)
19
Set name of wired zone
XXXX+WNAMEn pppp
n = wired zone (1 to 8), p= name of wired zone (up to
15 characters). This name will be used in SMS sent to
users & CMS.
20
Set name of first eight
wireless sensor
XXXX+WLNAMEn pppp
n = wireless sensor (1 to 8), p= name of wireless
sensor (up to 15 characters). This name will be used
in SMS sent to users & CMS.

21
Set system name
XXXX+SYSNAME qqqq
q= name of system (up to 15 characters). This name
will be used in SMS sent to users & CMS.
22
To Force Arm System
XXXX+FOARM
Arms the system even if a sensor is left open.
23
Date & Time setting
XXXX+DATE ddmmyy j hhmm
dd = date, mm=month , yy=year , j = day
(Mon=1…Sun=7), hh=hours, mm = minutes
24
No. of rings to pick up
incoming call
XXXX+RINGS n
n= number of rings to be assigned (1 to 8)
25
Sensors Open
XXXX+OPEN SENS
Displays all the sensors which are open
26
System reset
XXXX+RESETSYS
All data will be erased except the Telephone
Numbers and their SMS configuration.
Note: Messages are case sensitive. Enter in Capital letters only.
:XXXX in the above table refers to 4 digit Password
Programming by Android Application:
The free android application named ‘BAS-G’ is available on Google Play Store.
Steps to add your BAS-G panel in the application are as follows:
Press ‘LOGIN’ displayed on home screen of app
Press ‘ADD’
Enter System Name- a suitable name for the BAS-G System
Enter System Number- the number of SIM Card installed in BAS-G
Press ‘DONE’
The system name will now be displayed on the app.
Similarly, multiple systems can be added by pressing the ‘ADD’ option on top right corner
On pressing the name, you are shown options to Arm, Disarm, By Pass Arm, etc.
Press the desired option, and enter your password for the BAS-G panel.
For all other programming, press ‘Settings’, choose the desired programming, and enter your password to
Confirm
A confirmation SMS for the same will be received from the panel.
Wireless Sensor Type Table
Type
Code
Type
Code
MS
0
SMOKE
7
VSW
1
GAS
8
RMT
2
HHW
9
PIR
3
BEAM
A
TAMP
4
KBD
B
PANIC
5
MS+SW
C
HEAT
6
.Telephone Numbers Entry & SMS Controls .
User can enter up to 6 telephone numbers that can be dialed by the system. Each Telephone number can be
individually configured for:
Sensing & receiving SMS in selected events only.
You can set a Telephone number for SMS in all events (i.e., ARM, DISARM, PANIC, Batt. Low, Tamper, Intrusion, etc
+ user can send SMS from that Telephone number to ARM, DISARM, Change Pass Word, etc). After setting the
Telephone number for all events, you can disable selected events. Similarly you can Disable all events and enable
selected events.
To enter Telephone numbers that are to be dialed during intrusion:
Press Key “3”
Enter Master Password (1234) + #
Press “UP” or DOWN” to select the telephone number.
Press # + Back Space
Enter the Telephone number (Whenever Country code is used, make sure to add + before the country
code. “+” can be added through “” Key).
Each Telephone number can be of maximum 16 digits.
Press #
Quick Exit
Press “UP” or DOWN” to set the next /previous Telephone number in location 1 to 6.
Repeat the above steps for all the Telephone numbers
To configure Telephone numbers for SMS to be sent / received in all events or in NO event:
Press Key “3”
Enter Master Password (1234) + #
Press “UP” or DOWN” to select the telephone number.

Press #
Press # again
Press UP / DOWN Key to select the “All Cases”
Press 6 to Enable / Disable (If enabled, SMS will be sent/received in all events. If Disabled then in no
case SMS will be sent/received on that Telephone number)
Press #
Quick Exit
Press “UP” or DOWN” to set the next /previous Telephone number
Repeat the above steps for all the Telephone numbers
To configure Telephone numbers for SMS in selected events:
Press Key “3”
Enter Master Password (1234) + #
Press “UP” or DOWN” to select the telephone number.
Press #
Press # again
Press UP / DOWN Key to select the event
Press 6 to Enable / Disable
Press #
Press UP / DOWN Key to select another event
Press 6 to Enable / Disable
Press #
……………………… continue for various events
Quick Exit
Press “UP” or DOWN” to set the next /previous Telephone number in location 1 to 6.
Repeat the above steps for all the Telephone numbers
Note:The Telephone numbers are dialed by the system as per the sequence number 1 to 6.
:The display sows 2 Alphabets (AB) at the end of each Telephone number entered.
A = Y means “SMS feature” is available on that Telephone number.
= N means “SMS feature” is not available on that Telephone number.
B = Y means “Command feature” is available on that Telephone number.
= N means “Command feature” is not available on that Telephone number.
:If no Telephone number is entered, the system cannot be ARMED.
Deleting a Telephone number
Press Key “3”
Enter Master Password (1234) + #
Press “UP” or DOWN” to select the telephone number to be deleted.
Press # + Back Space
Press #
.Telephone Number Redial Times .
To set the number of times the system should dial each of the 6 Telephone numbers, following is the programming:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Redials”
Press # + Back Space
Press 01 to 15 + # + Quick Exit
Where, 01 to 15= No of Times to Redial
Note:If 3 is entered then System will dial each Telephone Number 3 times unless any of the called party dials # or
DISARMS by dialing 5.
:In default the number of Redial Times = 02
:If value entered is greater than 15 then system will accept the same but store it as 15.
.Telephone Number Display - ON / OFF .
Telephone Numbers being dialed by the system during intrusion are displayed on the Main Unit. This display can be
cancelled with the following programming.
Programming:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Tel Display”
Press #
Press key “UP” or “DOWN” to select ON / OFF
Press # + Quick Exit
Note:It is OFF in default.
.Voice Message Recording for playing on Telephone calls during Intrusion - Optional .
Voice message which the system plays after dialing Telephone number, during intrusion.
Programming for recording of message:
Press “SET”

Enter Master Password (1234) + #
Keep Pressing 2 to select “V Recrdng”
Press #
Press 1
Now start speaking near the Mic of the Main Unit. The recording starts when the display shows 10 and
ends at 1 i.e., total 10 secs of recording.
Press # + Quick Exit
Programming for Playback of recorded message:
Press “SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “V Recrdng”
Press #
Press 2
Listen to the recorded message. The play back starts when the display shows 10 and ends at 1.
Press # + Quick Exit
Note: When this option is not taken, the system plays a Siren Sound in its place.
.Wireless Sensors, Remotes & Panic Keys Registering/Deletion .
Maximum 75 Wireless Sensors (including Wireless Remotes & Signal repeaters) and unlimited Wireless Sirens can be
used in a system.
Every Wireless Sensor / Remote / Panic has a unique security code & has to be registered in the Main Unit in order to
make it functional.
Process: Press “SENSOR” key
Enter Master Password (1234) + #
Press 1
Keep Pressing 2 to select Type of Sensor to be registered. See the List below.
Wireless Sensor Type Display in case of Intrusion
Magnetic Snsr MS (In case of MS without Switch)
MS+SW (In case of MS with Switch)
Vibratn Snsr VIBRN
Remote RMT
PIR PIR
Tamper TAMP
Panic Remote PAN
Heat Detector HEAT
Smoke Detectr SMOKE
Gas Detector GAS
Heat/Humidity HHW (In default Temperature = 50 Deg Cent &
Humidity = 97%. To change these values
refer the HHW Manual.)
Beam Sensor BEAM
Wireless Kbrd “Not Applicable” (It is shown as KBD in History)
Flashing Sirn“Not Applicable”
Press # (In case of Magnetic Sensor, there will be another option to select “MS Widout Swch” or “MS with
Switch”. Press 1 for “Widout Swch” and 2 for “MS with Switch”. Magnetic Sensor with switch is
designed for applications where the door is opened / closed frequently during the day thereby
consuming too much of the battery of the sensor.)
Dial 01 to 75 (ID number to be given to the sensor. An ID number cannot be entered twice in a system.)
Press #
Now trigger the Wireless sensor (either Open the Sensor or Close the sensor) + # Quick Exit
In case of “Wireless Keyboard”:
Press 2 + Pass Word of the “Wireless Key Board” + #
Note: Whenever the intrusion take place, the Main Unit display will show the ID number of the Sensor and its Name.
For example: If a Magnetic Wireless Sensor is installed on the Main Door and is registered with N= 3 + ID
number = 11, then the display will show WL11: MS. Here, WL stands for Wireless & MS for
Magnetic Sensor.
:During triggering of the Wireless sensor (either Open the Sensor or Close the sensor), two short beeps in the
Main Unit confirms a successful setting & display shows “Successfully Sensed”.
Five short beeps means a wrong setting & display shows “This Zone ID is already allocated”.
:During the programming, the system auto cancels the operation if it doesn’t receive the input from Wireless
Sensor within 20 seconds.
:Smoke, Heat, Heat/Humidity, Signal Repeater, GAS & Tamper Type automatically gets registered in “Always
ARMED” mode and cannot be hanged to any other mode except to DISABLE mode.
Deletion of Single Wireless Sensor registration
To delete a Wireless Sensor registration from the Main Unit:
Press “SENSOR”
Enter Master Password (1234) + #
Press 2 + 2
Press UP or DOWN key to select the Sensor ID that is to be deleted.
Table of contents