Written by: R Patel Checked by: …AJC… Approved by: …JBJ……
Document No.: CBAPP Rev.: 7 Page 1 of 11 Date: 06/06/2003
CB200 Conventional Control Panel
Application Guide
Contents
1. Cabinet Specifications.............................................................................................2
2. Panel Hardware Specifications................................................................................3
3. Panel Configuration.................................................................................................4
4. Technical Specifications..........................................................................................6
5. CB200 Panel Enhancements...................................................................................8
6. CB200 Panel Compatible Zone Devices .................................................................9
7. Additional Available Documentation......................................................................10
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 2 of 11 Date: 06/06/2003
1. Cabinet Specifications
All cabinets are manufactured from polycarbonate with a satin textured finish. Eleven top
entry grommets are provided on a removable gland plate.
Cabinet colour: RAL7035 Textured (light grey)
12
FAULT
FIRE
ZONELOCATION
345678
1 2 3 4 5
cb200
e
d
c
a
b
ff
gg
Description Size
a Back box height 235mm
b Back box width 287mm
c Back box depth 66mm
d Front cover height 245mm
e Front cover width 313mm
f Bezel overhang - top/bottom 5mm
g Bezel overhang - left/right 13mm
Protection plugs = 11
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 3 of 11 Date: 06/06/2003
1.1.1 Order Codes & Descriptions
Part No Description
2500/383 CB200 1 zone conventional control panel
2500/384 CB200 2 zone conventional control panel
2500/385 CB200 4 zone conventional control panel
2500/386 CB200 8 zone conventional control panel
2500/967 CB200 8 zone repeater with power supply
2500/968 CB200 8 zone repeater powered from panel
2. Panel Hardware Specifications
2.1 User Controls and Indications (8 zone illustrated)
12
FAULT
FIRE
ZONELOCATION
345678
1 2 3 4 5
Slide in card to
add text zone
identification.
Zone fire LEDs
illuminate flashing
when a zone has been
triggered into fire.
Illuminates steady after
silence alarms has
been pressed.
Zone fault LEDs
illuminate flashing with
any zone fault or
device removed.
Illuminates steady
when zone is isolated.
Silence alarms/buzzer
control. Press to silence
alarm circuits or fault
buzzer.
Panel system control to
reset system after
silence alarms has
been pressed.
Functions as test LEDs
at any other time.
Evacuate
control operates
alarms circuits
(but not aux fire
output). Press
to operate,
press again to
stop.
Zone
isolate
control.
Access control. Press
5 to access user
control facility then
press 14, controls are
then enabled. Repeat
above to disable
controls.
Flashes when an alarm
circuit is in fault.
Illuminates when controls are active.
Supply healthy LED illuminates when both
mains and battery supplies are healthy.
Flashes when a battery supply fault occurs.
Flashes when engineer's
one man test is active.
(4-8 zone only).
Flashes when a processor
fault occurs.
Flashes when an
earth fault occurs
(4-8 zone only).
Flashes when a
repeater fault occurs
(4-8 zone only).
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 4 of 11 Date: 06/06/2003
2.2 Engineer Facilities
2.2.1 Mechanical Assembly Illustration
-
+
Battery leads
Red/Black
Battery link (Blue)
Fixing screws
Display cover
PCB terminals LED indications
User controls
Terminal cover
Company logo
Transformer
Mains terminals
2 x 12v 2.1 Ah batteries
+
Battery space
-
Removable gland
plate with
protection plugs
PCB support
Pre-formed
Semi-flush
bezel top fixing
Key hole
3. Panel Configuration
3.1 Buzzer Enable Link
The “Link for Buzzer Enable” link, located at the top right corner of the Control Board, is a
buzzer disable/enable facility. Its purpose is to disable the buzzer should this be helpful
during commissioning. DO NOT remove this link except in exceptional circumstances.
This link is not monitored by the control board and no faults or indications of any kind will
be generated if the link is removed.
3.2 Engineer’s Control:- 1-2 Zone Panels
This facility is located on the top right hand corner of the PCB. Its functions are described
below:
3.2.1 Processor Reset
Press to reset if the “Processor Fault” LED illuminates
3.2.2 One-man Test
If pressed for more than 5 seconds the panel will go into One-man Test mode.
3.2.3 Zone 1 Non-latch
Setting the zone 1 non-latch DIL switch to the ON position causes zone 1 to operate
in a non-latching fire indication mode. In this mode, if a fire condition occurs on zone
1 the panel will indicate the fire condition and operate the alarms. The auxiliary fire
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 5 of 11 Date: 06/06/2003
relay contacts will not be operated. If the fire condition is cleared from zone 1 then the
zone 1 fire indication is cleared and, as long as no other zones are in fire, the alarms
are also cleared. If any other zone is in a fire condition the panel will remain in the fire
condition until manually reset.
3.2.4 Class Change Input
This input is not fault monitored and is normally open. When a short circuit is placed
across input terminals the panel operates the alarm circuits and internal buzzer. The
input is non-latching.
3.3 Engineer’s Controls:- 4-8 Zone Panels
The following functions are available through the Engineer’s Access Code:
i) One-man Test
ii) Earth Fault enable/disable
iii) Clear Processor Fault indication – if the processor stops, the “Proc. Fault”
LED will illuminate. The processor will start automatically unless there is a
hardware fault.
3.4 CB200 Repeater Panel
A repeater panel is available for the CB200 4 and 8 zone panels. This is connected using
RS485 serial communications over a screened twisted pair cable. Up to 3 repeaters can
be connected to the control panel and provide the following features at a remote location:
•Indication of zonal fire, zonal fault and zonal isolate conditions
•Operation of Buzzer Silence, Manual Evacuate, Alarms Silence and System
Reset functions
•Indication of control panel status
•Indication of communication fault with control panel
•Indication of local power supply fault (if fitted)
•Indication of power supply fault on another repeater (steady Batt. Fault LED)
•Indication of a communication fault on another repeater. (Steady Comms.
Fault LED)
•NOTE: Only one repeater can be powered from the 24VDC supply output on
the control panel.
3.5 Repeater Configuration
The following configuration is associated with the repeater:
•Number of repeaters connected to panel (on panel)
•Repeater address (on each repeater)
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 6 of 11 Date: 06/06/2003
4. Technical Specifications
CB200 1-2 zone control panel
Maximum field equipment load: 800mA
Auxiliary 24VDC output 250mA
Mains failed current consumption: 35mA
Integral charger output: 500mA
Common fire output:
Common fault output: Volt- free contacts - 1A, 30V DC max.
Volt- free contacts - 1A, 30V DC max.
Alarm circuit output: 2 at 250mA each
Battery size: 2 x 12V 2.1AH sealed lead acid
Weight (excluding batteries): 2.3kg
CB200 4 zone control panel
Maximum field equipment load: 800mA
Auxiliary 24VDC output 250mA
Mains failed current consumption: 40mA
Integral charger output: 500mA
Common fire relay:
Common fault output: Volt- free contacts - 1A, 30V DC max.
Volt- free contacts - 1A, 30V DC max.
Alarm circuit output: 4 at 500mA each
Battery size: 2 x 12V 2.1AH sealed lead acid
Weight (excluding batteries): 2.3kg
CB200 8 zone control panel
Maximum field equipment load: 800mA
Auxiliary 24VDC output 250mA
Mains failed current consumption: 40mA
Integral charger output: 500mA
Common fire relay:
Common fault output: Volt- free contacts - 1A, 30V DC max.
Volt- free contacts - 1A, 30V DC max.
Alarm circuit output: 4 at 500mA each
Battery size: 2 x 12V 2.1AH sealed lead acid
Weight (excluding batteries): 2.4kg
CB200 8 zone repeater panel with power supply
Mains failed current consumption: 40mA @24VDC
Integral battery charger output: 500mA @27.5VDC
Auxiliary 24VDC output 250mA
Battery size: 2 x 12V 2.1AH sealed lead acid
Weight (excluding batteries): 2.4kg
CB200 8 zone control panel powered from panel
Current consumption: 40mA @24VDC
Weight: 1.4kg
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 7 of 11 Date: 06/06/2003
RS485 Cable Specification
Generic Type: RS422/RS485 data cable.
Conductors: Single pair plus screen.
Alpha cable: 3492C, 6222C, 6412 or equivalent
Belden cable: 8102, 8132, 9841 or equivalent
NOTE:On 4 and 8 zone panels the total available current for field devices is 800mA
at 28VDC. This current must be shared between the auxiliary 24VDC supply
and the four alarm circuits such that the total current drain across the five
circuits does not exceed 800mA.
4.1 Typical Terminal Wiring Schematic (8 zone illustrated)
Note: This is a schematic representation only and not a PCB layout drawing.
CLASS
CHANGE AUX FAULT
N/O P N/C AUX FIRE
N/O P N/C ALARM CIRCUITS
AL4- AL4+ AL3- AL3+ AL2- AL2+ AL1- AL1+ ZONE 8
Z8- Z8+ ZONE 1
Z1- Z1+ REPEATER
B A SCN AUX
24V 0V 24V
BAT- BAT+
SECONDARY EARTH
AC IN .
~~.
LINK FOR
BUZZER
ENABLE
L E N
230V AC 50Hz
5A MAINS
SUPPLY
3K9 RESISTOR
End-Of-Line
Device
NORMALLY
OPEN
SWITCH ALARMS 1, 2 & 3 SAME
AS ALARM 4
+
+
-
-
+
+
-
-
ZONES 2-8
SAME AS
ZONE 1 +
-
+
+
-
+
-
22uF CAPACITOR
End-Of-Line
Device +
-
+
-
12V
BATTERY
12V
BATTERY
MANUAL CALL
POINT WITH
680R
RESISTOR
DETECTOR
BASE WITH
SCHOTTKY
DIODE
1 2
1A 2A
230V AC
TRANSFORMER
1234
ON
RA0
RA1
Z1NL
NU
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 8 of 11 Date: 06/06/2003
4.2 Typical Repeater Wiring Schematic
5. CB200 Panel Enhancements
The CB200 panel may be enhanced to provide additional facilities. The following table
lists compatible panel enhancement products. Other relevant documentation is available
providing more details.
5.1 Panel Enhancement Order Codes & Descriptions
Part No Descript
ion
2500/032 C1437 4 way alarm extender board - separate PSU required
2500/034 A1466 1 x double pole relay board (1A contacts)
2500/233 Heavy duty relay boxed (suppressed) – additional power supply required
(2500/197 or 2500/198 as appropriate)
2
500/220 Enclosure c/w 1A PSU & space for 4 x C1437 and 2 x A1466 & 6.2AH
battery set Cabinet size - 380h x 600w x 210d
2
500/221 Enclosure c/w 3A PSU & space for 2 x C1324 or 4 x C1437 boards
Cabinet size - 380h x 600w x 210d
2
500/222 Enclosure c/w 5A PSU & space for 2 x C1324 or 4 x C1437 boards
Cabinet size - 380h x 600w x 210d
5.2 Battery Sizes (YUASA)
The CB200 panel has been designed to house the 2.1AH battery set. The following
batteries are suitable for any relevant expansion items, along with auxiliary power
supplies, and should be selected accordingly.
Battery Rating Battery Size
3.2AH battery 12V 134 length x 67 wide x 64 high
6.2AH battery 12V 151 length x 65 wide x 97.5 high
12AH battery 12V 151 length x 98 wide x 97.5 high
15AH battery 12V 181 length x 98 wide x 167 high
CIRCUITS
AL2- AL2+ AL1- AL1+
1234
ON
RA0
RA1
Z1NL
NU
ZONE 8
Z8- Z8+ ZONE 1
Z1- Z1+ REPEATER
B A SCN AUX
24V 0V
REPEATER
CONFIGURATION
DIL SWITCHES
ZONE 1 NON-LATCH
MODE ENABLE
CB200 4/8 ZONE PANEL
MOTHERBOARD
SPARE SWITCH
NOT USED
CIRCUITS
AL2- AL2+ AL1- AL1+
1234
ON
RA0
RA1
Z1NL
NU
ZONE 8
Z8- Z8+ ZONE 1
Z1- Z1+ REPEATER
B A SCN AUX
24V 0V
REPEATER
ADDRESS
DIL SWITCHES
CB200 4/8 ZONE REPEATER
MOTHERBOARD
SPARE
SWITCHES
NOT USED
TO NEXT
REPEATER
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 9 of 11 Date: 06/06/2003
6. CB200 Panel Compatible Zone Devices
The CB200 panel is designed to operate with the following devices. Detectors marked
* have been tested for compatibility. The remainder have electrical characteristics that
are similar enough to the tested units to be listed as compatible.
Manufacturer Part no. Description Maximum
Quantity
Per Zone
Apollo 53541-151 Series 30 ionisation detector 32 *
Apollo 53551-201 Series 20 optical detector 32 *
Apollo 53531-221 Series 30 Grade 1 heat detector 32
Apollo 45681-007 Series 20/30 mounting base 32 *
Apollo 55000-200 Series 60 ionisation detector 32 *
Apollo 55000-210 Series 60 integrating ion detector 32
Apollo 55000-100 Series 60 Grade 1 heat detector 32
Apollo 55000-101 Series 60 Grade 2 heat detector 32
Apollo 55000-102 Series 60 Grade 3 heat detector 32
Apollo 55000-103 Series 60 Range 1 heat detector 32
Apollo 55000-104 Series 60 Range 2 heat detector 32
Apollo 55000-300 Series 60 optical detector 32 *
Apollo 55000-380 Series 60 optical/heat detector 32
Apollo 45681-200 Series 60 mounting base 32 *
Hochiki SLK-E CD Range optical detector 32 *
Hochiki SIH-E CD Range ionisation detector 32 *
Hochiki DFE-60E CD Range 60 heat detector 32
Hochiki DFE-90E CD Range 90 heat detector 32
Hochiki DCC-1EL CD Range Grade 1 heat detector 32
Hochiki DCC-2EL CD Range Grade 2 heat detector 32
Hochiki DCC-1REL CD Range R1 heat detector 32
Hochiki YBK-RL/4H1 CD Range mounting base 32 *
Hochiki SLR-AS CDX Range optical detector 32 *
Hochiki SIJ-E CDX Range ionisation detector 32
Hochiki DFJ-60E CDX Range 60 heat detector 32
Hochiki DFJ-90E CDX Range 90 heat detector 32
Hochiki DCD-R1E CDX Range Grade 1 heat detector 32
Hochiki DCD-1E CDX Range Grade 2 heat detector 32
Hochiki DCD-2E CDX Range R1 heat detector 32
Hochiki YBN-R/4SK CDX Range mounting base 32 *
Honeywell TC804E-1022 Optical detector 32 *
Honeywell TC805E-1005 Ionisation detector 32 *
Honeywell TC830-1004 Heat detector 32
Honeywell 14506587-005 Mounting base (Diode version) 32 *
Nittan 80000 Sensortec ST-I ionisation detector 32
Nittan 80100 Sensortec ST-P optical detector 32
Nittan 82012 Sensortec STB-4SDR base 32
System Sensor 1151E Ionisation detector 32 *
System Sensor 2151E Optical detector 32 *
System Sensor 5451E Grade 1 heat detector 32
System Sensor 4451E Range 1 heat detector 32
System Sensor 1451E Ionisation detector 32 *
System Sensor 2451E Optical detector 32 *
System Sensor B401RSD Mounting base 32 *
www.acornfiresecurity.com

Written by: R Patel Checked by: AJC
Document No.: CBAPP Rev.: 7 Page 10 of 11 Date: 06/06/2003
Manufacturer Part no. Description Maximum
Quantity
Per Zone
Ziton Z630-1 Optical detector 32 *
Ziton Z610-1 Ionisation detector 32 *
Ziton Z6BS2A Mounting base 32 *
KAC KR9-680 Manual call point Unlimited
6.1 Notes
1. When using Hochiki smoke detectors (types SIHE and SLKE) fit a 3K9 0.25 watt resistor
across terminals L1 and S4.
2. When using Nittan detectors with RB3R bases fit a 220 ohm resistor across L and S1.
3. All call points must have a resistor in the range 470 Ohm to 680 Ohm fitted to them.
6.2 Other Compatible Zone Devices Order Codes & Descriptions
Part No Description
2501/012 Break glass unit without back box c/w 680 ohm resistor
2501/013 Break glass unit with back box c/w 680 ohm resistor
2500/226 Remote square indicator
2500/227 Remote round indicator
2501/014 Spare glasses for break glass units (pack of 5)
6.3 General Accessories Order Codes & Descriptions
Part No Description
2501/032 2.1AH S.L.A. battery set (2 x 12V)
2501/040 150mm bell (24 volts DC)
2501/044 Roshni Electronic Sounder (24 volts DC)
2501/043 Xenon flashing beacon (24 volts DC - 2 watts)
2501/033 Door retainer (24 volts DC) - auxiliary power supply required
2501/034 Door retainer (230 volts AC)
2501/035 Door retainer floor bracket
2500/198 1A 24V DC door retainer power supply unit in enclosure (no battery back-up)
Size - 300h x 350w x 75d
2500/197 MPC1 1A power supply unit in enclosure with space for 3.2AH battery set
Size 300h x 350w x 75d
2500/199 MPC3 3A PSU in enclosure with space for 12AH battery set
Size 355h x 370w x 90d
2500/200 MPC5 5A PSU in enclosure with space for 24AH battery set
Size 300h x 360w x 190d
2500/201 MPC10 10A PSU in enclosure with space for 24AH battery set
Size 500h x 500w x 210d