PRODUCT DESCRIPTION: Electric power control
SCOPE OF APPLICATION: Thermal control process
DESCRIZIONE DEL PRODOTTO: Unità di controllo potenza elettrica
UTILIZZO: Controllo processi termici
FULFILS THE REQUIREMENTS OF THE STANDARD:
Electrical safety Standard EN60947-1: 2007 + A1 2011, A2 2014
EN60947-4-3: 2014
Generic Emission standard EN60947-4-3: 2014 Group 1 Class A emissions
Generic Immunity standard EN60947-4-3: 2014 Industrial Immunity
SODDISFA I REQUISITI DELLA NORMA:
Specica di sicurezza EN60947-1: 2007 + A1 2011, A2 2014
EN60947-4-3: 2014
Specica sulle emissioni EN60947-4-3: 2014 gruppo 1 emissioni classe A
Specica sulle Immunità EN60947-4-3: 2014 Immunità industriale
CDAutomation declares that the products above mentioned are conforming to the directive
CDAutomation dichiara che i prodotti sopra menzionati sono conformi alla direttiva
Alla direttiva Bassa Tensione (low Voltage) EMC directive updated 2014/30/EU,
Low Voltage Directive updated 2014/35/EU
Issued on: 20/03/2017
Data di emissione: 20/03/2017
Amministratore Unico e
Legale Rappresentante
Simone Brizzi

Declaration of conformity
Declaration of conformity-Dichiarazione di Conformità
PRODUCT MANUFACTURER / PRODUTTORE:
CD Automation S.R.L.
Controllers, Drives & Automation
Via Picasso, 34/36 - 20025 Legnano (MI)- Italy
P.I. 08925720156 -Tel. +39 0331 577479 - Fax +39 0331 579479
E-mail: info@cdautomation.com - Web: www.cdautomation.com
Declare that the product / Dichiara che il prodotto:
Revo C 2Ph 60-210A
PRODUCT DESCRIPTION: Electric power control
SCOPE OF APPLICATION: Thermal control process
DESCRIZIONE DEL PRODOTTO: Unità di controllo potenza elettrica
UTILIZZO: Controllo processi termici
FULFILS THE REQUIREMENTS OF THE STANDARD:
Electrical safety Standard EN60947-1: 2007 + A1 2011, A2 2014
EN60947-4-3: 2014
Generic Emission standard EN60947-4-3: 2014 Group 1 Class A emissions
Generic Immunity standard EN60947-4-3: 2014 Industrial Immunity
SODDISFA I REQUISITI DELLA NORMA:
Specica di sicurezza EN60947-1: 2007 + A1 2011, A2 2014
EN60947-4-3: 2014
Specica sulle emissioni EN60947-4-3: 2014 gruppo 1 emissioni classe A
Specica sulle Immunità EN60947-4-3: 2014 Immunità industriale
CDAutomation declares that the products above mentioned are conforming to the directive
CDAutomation dichiara che i prodotti sopra menzionati sono conformi alla direttiva
Alla direttiva Bassa Tensione (low Voltage) EMC directive updated 2014/30/EU,
Low Voltage Directive updated 2014/35/EU
Issued on: 07/03/2022
Data di emissione: 07/03/2022
Amministratore Unico e
Legale Rappresentante
Simone Brizzi

4
REVO C 2PH from 60A to 210A User’s manual
Important warnings for safety
This chapter contains important information for the safety. The not observance of these instructions may result
in serious personal injury or death and can cause serious damages to the Thyristor unit and to the components
system included.
The installation should be performed by qualied persons.
In the manual are used symbols to give more evidence at the notes of safety and operativity for the attention
for the user:
This icon is present in all the operational procedures where the Improper
operation may result in serious personal injury or death by Electrical Shock
Hazard Symbol (a lightning bolt in a triangle) precedes an electric shock hazard
CAUTION or WARNING safety statement.
Warning or Hazard that needs further explanation than the label on unit can
provide. Consult User’s Guide for further information.
Unit is compliant with European Union directives.
See Declaration of Conformity for further details on Directives and Standards
used for Compliance.
If available, unit is a Listed device per Underwriters Laboratories. It has been
investigated to ANSI/UL® 508 standards for Industrial Control Switches and
equivalent to CSA C22.2 #14.
For more detail search for File E231578 on www.ul.com
ESD Sensitive product, use proper grounding and handling techniques when
installing or servicing product.
Do not throw in trash, use proper recycling techniques or consult manufacturer
for proper disposal.
A “NOTE” marks a short message to alert you to an important detail.
A “CAUTION” safety alert appears with information that is important for protecting your equipment and
performance. Be especially careful to read and follow all cautions that apply to your application.
A “WARNING” safety alert appears with information that is important for protecting you, others and equipment
from damage. Pay very close attention to all warnings that apply to your application.
Safety notes
WARNING! To avoid damage to property and equipment, injury and loss of life, adhere to applicable
electrical codes and standard wiring practices when installing and operating this product. Failure to do
so could result in damage, injury and death.
AVERTISSEMENT! Pour éviter d’endommager la propriété et l’équipement, les blessures et la perte
de vie, respecter les codes électriques en vigueur et les pratiques de câblage standard au moment
de l’installation et de l’utilisation de ce produit. Dans le cas contraire, cela peut entraîner la mort, des
blessures graves ou des dommages.
IND. CONT. EQ.
E231578 2RD5

REVO C 2PH from 60A to 210A User’s manual
5
WARNING! All service including inspection, installation, wiring, maintenance, troubleshooting, fuse
or other user serviceable component replacement must be performed only by properly qualied
personnel. Service personnel must read this manual before proceeding with work. While service is
being performed unqualied personnel should not work on the unit or be allowed in the immediate
vicinity.
AVERTISSEMENT! Tous les services, y compris l’inspection, l’installation, le câblage, l’entretien, le
dépannage, le remplacement de fusibles ou d’autres composants pouvant être réparés par l’utilisateur,
doivent être eectués uniquement par un personnel diment qualié. Le personnel de service doit lire ce
manuel avant d’eectuer tout travail. Pendant que l’entretien est exécuté, tout personnel non qualié ne
doit eectuer de travail sur l’appareil ni se trouver a proximité.
WARNING! When in use the power controller is connected to dangerous voltages. Do not remove the
protective covers without rst disconnecting and preventing power from being restored while servicing
the unit.
AVERTISSEMENT! Au moment de l’utilisation, le régulateur de puissance est connecté a des tensions
dangereuses. Ne retirer aucun couvercle de protection sans d’abord débrancher l’appareil et ainsi
empêcher l’alimentation d’être rétablie pendant l’entretien.
WARNING! Do not use in aerospace or nuclear applications.
AVERTISSEMENT! Ne pas utiliser pour les applications aérospatiales ou nucléaires.
WARNING! The units are not developed to manage capacitive loads.
AVERTISSEMENT! Les unités ne sont pas développées pour la conduite de charges capacitives.
WARNING! The power controller’s protection rating is IP20 with all covers installed and closed. It must
be installed in an enclosure that provides all the necessary additional protections appropriate for the
environment and application.
AVERTISSEMENT! L’indice de protection du régulateur de puissance est de IP20 lorsque les couvercles
sont installés et fermés. L’appareil doit être installé dans une enceinte qui assure toute la protection
supplémentaire nécessaire pour l’environnement et l’application.
WARNING! Ground the power controller via the provided protective earth grounding terminal. Verify
ground is within impedance specications. This should be veried periodically.
AVERTISSEMENT! Mise a la terre du régulateur de puissance par le biais de la borne de prise de terre
de protection fournie. Vérier que la prise de terre est conforme aux spécications de l’impédance. Cela
doit être vérié périodiquement.
WARNING! Electric Shock Hazard: when the power controller has been energized, after shutting o the
power, wait at least one minute for internal capacitors to discharge before commencing work that brings
you in to contact with power connections or internal components.
AVERTISSEMENT! Risque de décharges électriques: lorsque le régulateur de puissance est mis sous
tension, après avoir été éteint, attendre au moins une minute pour que les condensateurs internes se
déchargent avant de commencer tout travail incluant le contact avec les connexions électriques ou les
composants internes.
WARNING! The installation must be protected by electromagnetic circuit breakers or by fuses. The
semiconductor fuses located inside the power controller are classied for UL as supplementary
protection for semiconductor devices. They are not approved for branch circuit protection.
AVERTISSEMENT! L’installation doit être protégée par des disjoncteurs électromagnétiques ou des
fusibles. Les fusibles pour semi-conducteurs situés a l’intérieur du régulateur de puissance sont classés
UL comme protection supplémentaire pour les dispositifs pour semi-conducteurs. Ils ne sont pas
approuvés pour la protection des circuits de dérivation.
WARNING! When making live voltage or current measurements, use proper personal protective
equipment for the voltages and arc-ash potentials involved.
Table of contents
Other CD Automation Industrial Equipment manuals