Centralite AZELA ZIGBEE HA User manual

AZELA ZIGBEE HA Lamp Module
4256050-ZHA,ZHAC
Rated: 120 VAC, 60Hz
Rated 300W Incandescent @ 120V AC
Warnings and Cautions:
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any of these instructions, consult a qualified electrician.
Unplug unit when servicing connected lamps.
Save this instruction sheet. It contains important technical data along with testing
and troubleshooting information which will be useful after installation is complete.
INTRODUCTION
The CentraLite Azela ZIGBEE HA Lamp Module uses the
Zigbee Home Automation(HA) communication protocol to
link with other Zigbee HA devices. Each Lamp Module
acts as a router for messages sent through the Zigbee
network.
FEATURES
Status LED
Load control from button on Lamp Module
Ease of installation
Compatible with other Zigbee HA certified level
controllers
ZHAC devices sense and report realtime load
current consumption
INSTALLATION
STEP 1
Attach the plug from the lamp to be con-
trolled into the receptacle of the Lamp
Module.
STEP 2
Attach Lamp Module to wall receptacle.
Verify that the receptacle is powered. If
the receptacle is powered by a wall
switch, the wall switch must be kept ON
at all times for the module to operate
properly.
STEP 3
To join the ZIGBEE HA Lamp Module to
a certified HA controller be sure that the
HA controller is open for joining. If the
Lamp Module has not been joined to a
network then press and hold the Lamp
Module button. The Lamp Module will
then attempt to join an open HA network.
Upon a successful joining of the Lamp
Module to a Zigbee HA network the
status LED will blink 2 times. When the
Lamp Module powers up after being
joined to a Zigbee HA network, it will
blink 2 times.
4256050-ZHA,ZHAC
STEP 3 cont’d
If the Lamp Module will not join a Zigbee
HA network then:
Make sure the Lamp Module is
powered up
Ensure the Lamp Module is within
RF range of a routing device
Make sure the target Zigbee net-
work is open for joining
STEP 4
Once the Lamp Module is joined to the
Zigbee HA network, use the certified HA
controller to configure the Lamp Module.
STEP 5
If it becomes necessary to remove the
Lamp Module from a Zigbee HA network
then you must factory default the Lamp
Module. To factory default the Lamp
Module:
Remove the Lamp Module from the wall
receptacle
Press and hold the Lamp Module button
Reinstall the Lamp Module into the wall
receptacle while holding the button
After 2 seconds the status LED will turn
ON
Once the LED is ON let go of the button
The Lamp Module will now be reset to
factory defaults and ready to join to a
Zigbee HA network.
www.centralite.com

LIMITED 3 YEAR WARRANTY AND EXCLUSIONS
CentraLite warrants to the original consumer purchaser and not for
the benefit of anyone else that this product at the time of its sale
by CentraLite is free of defects in materials and workmanship under
normal and proper use for three years from the purchase date.
CentraLite’s only obligation is to correct such defects by repair or
replacement, at its option, if within such three year period the
product is returned prepaid, with proof of purchase date, and a
description of the problem to CentraLite. This warranty
excludes and there is disclaimed liability for labor for removal of
this product or reinstallation. This warranty is void if this product
is installed improperly or in an improper environment,
overloaded, misused, opened, abused, or altered in any manner,
or is not used under normal operating conditions or not in
accordance with any labels or instructions. There are no other
or implied warranties of any kind, including merchantability and
fitness for a particular purpose, but if any implied warranty is
required by the applicable jurisdiction, the duration of any such
implied warranty, including merchantability and fitness for a
particular purpose, is limited to three years. CentraLite is not liable
for incidental, indirect, special, or consequential damages,
including without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform this
warranty obligation. The remedies provided herein are the
exclusive remedies under this warranty, whether based on
contract, tort or otherwise.
For Warranty service call CentraLite Systems customer support at
1-877-466-5483.
Limited Warranty
AZELA ZIGBEE HA Lamp Module
4256050-ZHA,ZHAC
Rated: 120 VAC, 60Hz
Rated 300W Incandescent @ 120V AC
4256050-ZHA,ZHAC
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may
cause harmful inerference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsi-
ble for compliance could void the user's authority to operate the equip-
ment.
FCC ID: T3L-JS004
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numériqué de la classe B est conformé à la norme NMB-003
du Canada.
Troubleshooting
If the Lamp Module is not working properly, pro-
ceed with the following steps:
Make sure the device is being supplied with
a 120V, 60 Hz AC source.
Check the load that is being controlled. Is
the lamp fixture turned on?
Make sure the controlled load does not
exceed 300 Watts.
If the load works locally with the Lamp Mod-
ule button but does not respond to network
commands, then repeat installation steps
starting with STEP 1.
WARNING!
If a direct short is created on the output, the Lamp Module
will be damaged and will no longer function.
ATTENTION!
Si un court-circuit direct est créé sur la sortie, le module
appareil sera endommagé et ne fonctionnera plus.
WARNING!
If a load greater than 300 Watts is attached to the output,
the Lamp Module will be damaged and will no longer
function.
ATTENTION!
Si une charge supérieure à 15 ampères est fixé à la sor-
tie, le module appareil sera endommagé et ne fonction-
nera plus.
CAUTION! RISK OF ELECTRIC SHOCK—Disconnect
power to the receptacle before installing or remov-
ing the unit. When removing receptacle cover
screw, cover may fall across plug pins or receptacle
may become displaced. Use only with duplex re-
ceptacle having center screw. Secure unit in place
by receptacle cover screw. Dry Location use only.
ATTENTION! RISQUE DE CHOC ÉLECTRIQUE-
Débrancher la prise avant d'installer ou de retirer
l'unité. Lorsque le réceptacle de retirer le couvercle
à vis, couvercle risque de tomber entre les broches
fiche ou la prise peut se déplacer. Utiliser unique-
ment avec prise double ayant vis du centre. Fixer
l'appareil en place par la vis couvercle de la prise.
Lieu sec seulement.
Popular Control Unit manuals by other brands

Bray
Bray TRI LOK Series Installation, operation and maintenance manual

Lenze
Lenze E94AZHY0025 Mounting instructions

elobau
elobau 471 M41 H31 Translation of the original operating instructions

Keysight Technologies
Keysight Technologies N3301A Programming guide

Quectel
Quectel UC15 Hardware design

Spirax Sarco
Spirax Sarco DCV8 Installation and maintenance instructions