SLFLED10(W)/30(W)/50(W) Instructions Rev02
INSTALLATION INSTRUCTION
MODELS: SLFLED10; SLFLED10W; SLFLED30; SLFLED30W; SLFLED50; SLFLED50W
IMPORTANT NOTE: Installation must be erformed by a skilled/com etent electrician who is familiar with the a ro riate standards and
technical requirements of the a liance and its ro er installation.
Never modify the unit as there are no user serviceable arts inside. Not suitable for use with dimmer switches.
Install in accordance with IEC Wiring Regulations.
●
Read these instructions carefully before attem ting to install fitting. Retain instruction for future reference.
●
Disconnect the mains su ly before installing or servicing.
●
All wiring should be erformed by a qualified electrician. This fixture is for outdoor use and should not be used in
areas with limited ventilation or high ambient tem eratures.
POSITIONING THE UNIT
When selecting the mounting osition, take the following oints into account:
The sensor is designed for o timum erformance when mounted 1.8-2.5 meters above ground level.
Avoid ositioning close to trees or shrubs which may cause false triggering during wet, windy weather.
Avoid ointing at or ositioning close to heat sources such as flues or heat extraction units, which may
cause false triggering.
Avoid ointing at bright lights as unit will not function when you set day/night control level to dark (_ osition)
Avoid mounting close to strong electromagnetic fields, which may cause false triggering.
The sensor is most sensitive to movement across the detection area as o osed to directly towards or away from the unit. Position the sensor so movement is
across the sensor (See Fig 2)
INSTALLATION-Surfac Mounting
1. Do not remove any art of the fixture.
2. Mount the fitting at a height between 1.8m-2.5m meters (see Fig.2).
3. Use ex ansion bolts to secure the fixture on mounting surface
The sensor should be ointing downwards. (See Fig.1)
4. Kee enough slack on the cable from the fittings to allow for the fitting to be adjusted On the bracket angle unhindered.
5. Connect the cable wires into terminal; Blue wire to “Neutral” terminal, Brown wire to “Live” terminal, Yellow / green wire to “Earth” terminal.
6.
Any external connections need to be made in a suitable IP rated enclosure, referably with cable entry at the bottom.
T st:
1. After installation, lease turn anti-clockwise the time adjuster (No:1 see Fig 3) to minimum and turn clockwise the day/night adjuster (No:3 see Fig 3) to day
setting before you switch on the mains su ly.
2. Walk test the sensor, the sensor is more sensitive to movement across the detection area as o osed to directly towards or away from the unit (See Fig 2).
3. Your floodlight is now ready to work. You can now adjust the eriod of time and ambient-light level that light will be o erational.
How to chang into MANUAL CONTRL MODE (Ov rrid Function)
1.When ower on, the PIR detector enters into the “WARM-UP” eriods for about 1 minute, then automatically change into AUTO MODE.
2. During AUTO MODE, the PIR detector will change to 8hours MANUAL MODE from AUTO MODE by an effective override (turn the wall switch off and on twice
in about three seconds). In MANUAL MODE, the Lam s (S) will remain on, not affected by duration time and Lux control level, after 8 hours, the lam will change
into AUTO MODE again.