13-11-614 Page 18
adequate size, provided with a relief valve of proper setting, a pressure gauge and a means of draining
condensate. A system with adequate volume would produce consecutive compressor unload cycles of
no less than 30 seconds.
MOISTURE SEPARATOR/ORIFICE- Since the unit is equipped with a built-in aftercooler, an integral
moisture separator and drain trap is furnished with the unit. The moisture from the trap is piped to the
compressor inlet flange.
INLET LINE - Where an inlet line is used between the air filter and the compressor, it must be
thoroughly cleaned on the inside to prevent dirt or scale from entering the compressor. If welded
construction is used, the line must be shot blasted and cleaned to remove welding scale. In either
case, the inlet line must be coated internally by galvanizing or painting with a moisture and oil-proof
sealing lacquer. Up to ten (10) feet in length, the inlet line should be the full size of the inlet opening on
the compressor. If an extra-long line is necessary, the pipe size should be increased according to “Inlet
Line” chart, Figure 2-4, page 18.
Accessibility for inlet air filter servicing must be considered when relocating the filters from the unit to a
remote location.
Length of Inlet Line Diameter of Pipe Size
0 to 10 Feet (0 to 3 Meters).............................. Same as Compressor Inlet Opening
10 to 17 Feet (3 to 5 Meters).............................. One size Larger Than Inlet Opening
17 to 38 Feet (5 to 11.5 Meters)......................... Two Sizes Larger Than Inlet Opening
Figure 2-4– INLET LINE LENGTHS
DISCHARGE SERVICE LINE - The discharge service line connection on the unit is at base level. See
“Package Illustrations, Figure 1-2and Figure 1-3, pages 7& 8. When manifolding two or more rotary
screw units on the same line, each unit is isolated by the check valve in the unit discharge line. If a rotary
screw unit is manifolded to another compressor, be sure the other compressor has a check valve in the
line between the machine and the manifold. If a rotary screw and reciprocating compressor are
manifolded together, an air receiver must be located between the two units.
DANGER
Discharge air used for breathing will cause severe injury or death. Consult
filtration specialists for additional filtration and treatment equipment to meet
health and safety standards.
The oil-free air discharging from the EWF package is saturated with water vapor at discharge
temperature. An air dryer may be required if the air is used in a moisture sensitive process. In addition,
the compressed air may be mixed with atmospheric contaminants entering the intake of the compressor.
UNIT WATER DRAIN - The unit drain ports should be connected to a floor drain(s). Drain line(s) must
slope downward, away from the unit, to allow effluent to flow by gravity, and must be vented to the
atmosphere to avoid the accidental back flow of said effluent into the package. As necessary, the
automatic water management system will open the drain solenoid valve to drain excess water. Since the
drain solenoid valve may open at any point during compressor operation, high temperature water under
pressure may be discharge from the unit. During operation, a small, steady stream of wash water is
normally discharged by the water treatment filter via the drain port.