For Electrical Heat
D-HB
w/70°F/39°C Rise Booster
Minimum Maximum
Supply Ckt. Overcurrent
Elec. Rated Conductor Protective
Specs. Amps Ampacity Device
208/60/3 57 60 60
240/60/3 64 70 70
480/60/3 29 35 35
575/60/3 25 30 30
Utilities
1 Electrical (See Box)
2Hot Water (DHB)
3/4” NPT hot water 140°F/60°C min for
40°F/22°C rise booster. 3/4” NPT hot water
110°F/43°C min for 70°F/39°C rise booster. Flow
pressure 20-22 psi. (138-151kPa)
Hot Water (DH1)
3/4” NPT 180ºF/82ºC hot water connection. Flow
presure 20-22 ps, (138-151 kPA)
3 Drain
2” O.D. connection. Max. flow rate
15 US gpm. (12imp.gpm/54/pm
For Electrical Heat
D-HB
w/40°F/22°C Rise Booster
Minimum Maximum
Supply Ckt. Overcurrent
Elec. Rated Conductor Protective
Specs. Amps Ampacity Device
208/60/1 71 80 80
240/60/1 79 90 90
208/60/3 40 50 50
240/60/3 45 50 50
480/60/3 20 25 25
575/60/3 16 20 20
SPECIFICATIONS
Capacity
Racks per hr. (NSF rated) 55
Wash tank US gal. (imp. gal/liters) 9 (7.5/3.4)
Motor horsepower 1
Water consumption
Gal. per hr. (max. use) US gal. (imp. gal/liters) 49 (41/186)
Gal. per rack (US gal. (imp. gal/liters) .86 (0.74/3.4)
Temperatures °F/°C
Wash 150/66
Rinse 180/82
Heating
Tank heat, electric, (kW) 4.7
Tank heat, steam (lbs.per hr.
required at 15 psi flow pressure) 25
DHB
only
Electric booster (kW required for 40°F/22°C rise) 9
Electric booster (kW required for 70°F/39°C rise) 13
Steam booster (internally mounted)
(lbs. per hr. required for 40°F/22°C rise) 50
Steam booster (internally mounted)
(lbs.per hr. required for 70°F/39°C rise) 65
Time cycle in seconds
Wash 40
Rinse 8
Dwell 12
Total cycle 60
1-1/8" 24-1/4"
7-1/4"
1-1/4" Roll
2-1/8"
20-7/8"
Typical Table Construction
Door-type High Temperature
Dishwashing Machine
DHB/DH1
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
Warning: Plumbing and electrical connection
should be made by qualified personnel who
will observe all the applicable plumbing,
sanitary and safety codes and the National
Electrical Code.
Plumbing Note: Because of the variation
in house-supplied water and steam
pressure, pressure regulating valves (PRV’s)
for incoming water and steam supply are
needed. The PRV’s can be purchased from
Champion or obtained locally.
Note: Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied
(by others) in common water supply line at
service connection.
For Electric Heat
D-H1 Electrical Power Requirements
Minimum Maximum
Supply Ckt. Overcurrent
Elec. Rated Conductor Protective
Specs. Amps Ampacity Device
115/60/1* 48 60 60
208/60/1 35 40 40
240/60/1 37 40 45
208/60/3 20 25 25
240/60/3 21 25 25
480/60/3 9 15 15
575/60/3 7 15 15
*3kW wash tank heat