1
TABLE OF CONTENTS
PREFACE.....................................................................................................2
GENERAL INFORMATION.......................................................................2
SAFETY INSTRUCTION ...........................................................................2
ENVIROMENTAL.......................................................................................3
CLEANING..................................................................................................3
MAINTENANCE.........................................................................................3
WEIGHING OPERATION ..........................................................................3
WARRANTY-LIABILITY...........................................................................4
DISPOSING OF THE SCALE.....................................................................4
SPECIFICATIONS.......................................................................................5
KEY FUNCTIONS.......................................................................................6
FEATURE DESCRIPTION..........................................................................7
INSTRUCTION FOR REPLACING BATTERY ........................................8
ERROR MESSAGE...................................................................................10

2
PREFACE
Thank you for choosing CHARDER MEDICAL product. All features of this
product were designed to state of the art and are optimized for simple and
straightforward use. If you have any queries or experience any problems
not addressed in the operating instructions, please contact your
CHARDER MEDICAL service partner, or visit us on the Internet at
www.chardermedical.com
GENERAL INFORMATION
We strongly recommend you use the scales on flat and hard surface. Any
soft surface, like carpet will cause inaccuracy.
SAFETY INSTRUCTION
Before putting the device into use, please read with care the
information given in the Operating Instructions. They contain important
instructions for installation, proper use and maintenance of the device.
The manufacturer shall not be liable for damages arising out of failure to
heed the following instructions:
When using electrical components under increased safety requirements,
always comply with the appropriate regulations.
Improper installation will render the warranty null and void.
Ensure the voltage marked on the power supply unit matches your mains
power supply.
This device is designed for use indoors.
Observe the permissible ambient temperatures for use
The device meets the requirements for electromagnetic compatibility. Do
not exceed the maximum values specified in the applicable standards.
If you have any problem, contact your local CHARDER MEDICAL service
partner.

3
ENVIROMENTAL
All batteries contain toxic compounds; disposal of batteries should be
delegated to a competent organisation, complying with the deposit of
Poisonous Waste Regulation 1972.
Please do not incinerate batteries.
The optimum operating temperature for the scale is 5℃to +35℃; although
it will operate at higher and lower temperatures the scales battery life will be
adversely effected.
CLEANING
We would recommend using alcohol based wipes or similar when cleaning
the scales.
Please do not use large amounts of water when cleaning the scales as this
will cause damage to the scales electronics, you should also refrain from
using corrosive liquids or high pressure washers.
Always disconnect the scales from the mains power supply before cleaning.
MAINTENANCE
The scale does not require any routine maintenance. However, we
recommend checking the scale’s accuracy at regular intervals. The
regularity of these checks is dependent on the level of use and the state of
the scale. If any inaccuracies occur, please contact your local dealer or
CHARDER MEDICAL service partner.
WEIGHING OPERATION
Before reading detailed instructions on how to use all the weighing
functions that are built into your scale, please read the following important
guidelines:
Always be sure that the display shows `Zero` before use, if it does not then
please press the ZERO key.

4
The Professional Medical scale is designed to detect when a stable weight
is achieved, the indicator will `bleep` twice to indicate a stable weight value,
your reading should be taken at this point.
WARRANTY-LIABILITY
If a fault or defect is present on receipt of the unit which is within CHARDER
MEDICAL’s scope of responsibility, CHARDER shall have the right to either
repair the fault or supply a replacement unit. Replaced parts shall be the
property of CHARDER. Should the fault repairs or replacement delivery not
be successful, the statutory provisions shall be valid. The period of warranty
shall be two years, beginning on the date of purchase. Please retain your
receipt as proof of purchase. Should your scale require servicing, please
contact your dealer or CHARDER MEDICAL Customer Service.
No responsibility shall be accepted for damage caused through any of the
following reasons: Unsuitable or improper storage or use, incorrect
installation or commissioning by the owner or third parties, natural wear,
changes or modifications, incorrect or negligent handling , overuse,
chemical, electrochemical or electrical interference or humidity, unless this
is attributable to negligence on the part of CHARDER MEDICAL.
If operating, climatic or any other influences lead to a major change in
conditions or material quality, the treaty for perfect unit functioning shall be
rendered null and void. If CHARDER provides and individual warranty, this
means that the unit supplied will be free of faults for the length of the
warranty period.
DISPOSING OF THE SCALE
This product is not to be treated as regular household waste, but should be
handed in to an electrical/electronic equipment recycling centre.
You can obtain further details from your local council, your municipal waste
disposal company or the firm which you purchased the product.

5
SPECIFICATIONS
Model# MS 2410
Capacity 20 kg x 10 g, 44 lb x 0.02 lb, 704 oz x 0.5 oz
Accuracy ±20g , ±0.04lb , ±1.0oz
Weight units kg, lb, oz, lb:oz
LCD Display Easy to read 1.0” LCD display with 4 1/2
digits
Dimension Platform surface:
20 x 14 x 2 in. (500 x 350 x 50 mm)
Key Function ON/ZERO/OFF, kg / lb, MEMORY
Power Supply 9V battery / 9V~12V adaptor
Operation
Temperature 5℃/ 35℃

6
KEY FUNCTIONS
Key Functions
ON/ZERO/OFF
Power on and power off.
Press to ZERO the weight of subject.
Press 3 seconds to power off.
Press to TARE the weight when the weight is at 2% of full capacity.
kg/lb
Press this key to switch unit between kg, lb, oz, and lb: oz.
MEMORY
Press to recall and release the weighing value.
If the weight is less than 1kg, press this key to recall the stored value
of weight. If the weight is greater than 1kg, press this key to store the
weight value.
ON
MEMORY
kg/lb
ZERO
OFF

7
FEATURE DESCRIPTION
MEMORY
When power on, the Memory feature will auto switch on and the arrow
besides HOLD at left bottom of LCD will flicker.
When the loaded weight is above 1kg and stable, the arrow stops flickering.
To disable the Memory function, please press ON/ZERO/OFF key again.
TARE
TARE only works when load is over 400g. When weight of subject is over
400g, press ON/ZERO/OFF key to tare the weight. When the arrow of hold
flickered, the TARE feature is working now. Put your target on the scale
and weigh.

8
REMOVING BATTERY COVER
STEP
2
.
STEP 1.
LOCAT
ING
BATTERY COVER
AT BOTTOM OF SCALE
INSTRUCTION FOR REPLACING BATTERY

9
INSTALLING 9V BATTERY
INSTALLING BATTERY COVER
STEP 4.
STEP 3.

10
LOW BATTERY
OVER ZERO
UNDER ZERO
If zero count is below the setting range, the
display will show “Errl” message. The
scale will turn off in 30 seconds if the status
continues.
OVERLOAD
If the total load exceeds the maximum
capacity of the scale, the display will show
“Err” message. The weight must be
removed immediately from the surface.
If zero count is higher than the setting
range, the display will show “Err” message.
The scale will turn off in 30 seconds if the
status continues.
If battery is discharged, the display will
show LOW. The operator should replace
the battery.
ERROR MESSAGE

11
Manufactured by:
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist.,,
Taichung City 412 ,Taiwan (R.O.C.)
IN-1062 [8048F] 04/2016