The flue system must be constructed from the appliance upwards, with all joints being
fully locked and sealed using the Chesneys specified parts.
Do not install the appliance in a bathroom or a room that contains a bath or shower.
It is advised that provisions be made for the removal of the appliance without the
need to dismantle the flue system.
Before the appliance is installed, the flue / chimney must be inspected to ensure that it
is structurally sound and free from obstructions.
Ensure the builders opening and supports are made of non combustible and heat
resistant material.
Do not cover the appliance and or do not wrap it in an insulation blanket or any other
material.
Do not make any changes to the appliance.
The gas connection must be in accordance with local and national regulations.
The use of a gas detection device is preferred method when investigating all
connections to the rear of the gas control valve. Please note the use of leak detector
fluid around the gas control valve is NOT recommended due to moisture being able to
enter and damage the valve.
Ventilation
GB current British Standard BS5440 appliances classified under 7kW (net) do not
require permanent ventilation.
NOTE - Ventilation requirements in other countries may vary please consult with
national regulations in your country.
WARNING - SPILLAGE MONITORING SYSTEM
The pilot light and flame sensing device fitted to this appliance is also an atmospheric
sensing device, this is not adjustable and must not be put out of action. If the pilot
light is damaged or faulty it should only be replaced with an original genuine unit
supplied by Chesneys.
When using stone like materials and or plaster finishing, the chimney breast should
dry for at least 6 weeks to prevent cracks.
The appliance is not fitted with an integral guard. It is recommended that a guard be
used for the protection of young children, the elderly or infirm and also for normal use
conforming to BS8423:2002, such that access to the hot appliance is minimised.
Do not place combustible materials directly in front of the appliance.
In case of a damaged or broken glass, do not use the appliance and isolate the gas to
the appliance.