Chromalox warrants only that the Products and parts manufactured by Chromalox, when shipped, and the work per-
formed by Chromalox when performed, will meet all applicable specification and other specific product and work require-
ments (including those of performance), if any, and will be free from defects in material and workmanship under normal
conditions of use. All claims for defective or nonconforming (both hereinafter called defective) Products, parts or work
underthiswarrantymustbemadeinwritingimmediatelyupondiscovery,andinanyevent,withinone(1)yearfromdeliv-
ery, provided, however all claims for defective Products and parts must be made in writing no later than eighteen (18)
months after shipment by Chromalox. Defective and nonconforming items must be held for Chromalox's inspections and
returned to the original f.o.b. point upon request. THE FOREGOING IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES
WHATSOEVER, EXPRESS, IMPLIED AND STATUTORY, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Notwithstanding the provisions of this WARRANTY AND LIMITATION Clause, it is specifically understood that Products
and parts not manufactured and work not performed by Chromalox are warranted only to the extent and in the manner
that the same are warranted to Chromalox by Chromalox's vendors, and then only to the extent that Chromalox is rea-
sonably able to enforce such warranty, it being understood Chromalox shall have no obligation to initiate litigation unless
Buyer undertakes to pay all cost and expenses therefor, including but not limited to attorney's fees, and indemnifies
Chromalox against any liability to Chromalox's vendors arising out of such litigation.
Upon Buyer's submission of a claim as provided above and its substantiation, Chromalox shall at its option either (i)
repair or replace its Products, parts or work at the original f.o.b. point of delivery or (ii) refund an equitable portion of the
purchase price.
THE FOREGOING IS CHROMALOX'S ONLY OBLIGATION AND BUYER'S EXCLUSIVE REMEDY FOR BREACH OF WAR-
RANTY, AND IS BUYER'S EXCLUSIVE REMEDY AGAINST CHROMALOX FOR ALL CLAIMS ARISING HEREUNDER OR
RELATING HERETO WHETHER SUCH CLAIMS ARE BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLI-
GENCE AND STRICT LIABILITY) OR OTHER THEORIES, BUYER'S FAILURE TO SUBMIT A CLAIM AS PROVIDED ABOVE
SHALL SPECIFICALLY WAIVE ALL CLAIMS FOR DAMAGES OR OTHER RELIEF, INCLUDING BUT NOT LIMITED TO
CLAIMS BASED ON LATENT DEFECTS. IN NO EVENT SHALL BUYER BE ENTITLED TO INCIDENTAL OR CONSEQUEN-
TIAL DAMAGES AND BUYER SHALL HOLD CHROMALOX HARMLESS THEREFROM. ANY ACTION BY BUYER ARISING
HEREUNDER OR RELATING HERETO, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE
AND STRICT LIABILITY) OR OTHER THEORIES, MUST BE COMMENCED WITHIN ONE (1) YEAR AFTER THE DATE OF
SHIPMENT OR IT SHALL BE BARRED. W2008M
WARRANTY AND LIMITATION OF REMEDY AND LIABILITY
99 - 039
TA - S9 - EF
Litho in U.S.A.
MOUNTING
WIRING
OPERATION
RENEWAL PARTS IDENTIFICATION
WARNING: Hazard of Shock. Any installation involving
electric heaters must be effectively grounded in accor-
dance with the National Electrical Code to eliminate
shock hazard.
Note: All wiring should be done in accordance with local codes and the
National Electrical Code by a qualified person as defined in the NEC.
1. Electrical wiring enters heater case through 7/8” opening in end of
heater.
2. Grounding conductor, with green insulation, should be secured to
grounding screw located on case.
WARNING: Hazard of fire or discoloration of temperature
sensitive fabrics. Keep combustible materials and such
fabrics at least 4” away from front of cover or above cover.
DANGER:Hazard of Fire. This heater is not intended for
use in hazardous atmospheres where flammable vapors,
gases, liquids or other combustible atmospheres are pre-
sent as defined in the National Electrical Code. Failure to
comply can result in explosion or fire.
MAINTENANCE
1. WARNING: Hazard of Shock. Disconnect all power
before attempting to service this heater.
2. Following long periods of idleness, heater should be vacuumed
before start-up to remove accumulated combustible particles which
will incinerate causing smoking and consequent wall discoloration.
3. If heater is located in areas of heavy traffic, furnish suitable heater
guard (wall mounted pipe rail in front of case, for example) to pre-
vent damage to heater.
Figure 1 — 240 Volt Heaters Figure 2 — 480 Volt Heaters
1234
Type V Heating Element Heater Insulating Insulating Wire Wiring
(Iron Sheath) Cover Bushing Bushing Sizes Diagram
Model Volts Watts (Prefix 152-) (Prefix 032-) (Prefix 032-) (90˚C Min) Fig No.
V-2020 240 2000 SE-2450 240V 500W (4) 108259-001 010978-001 (8) 010978-002 (8) #16 1
V-2030 240 3000 SE-2475 240V 750W (4) 108259-001 010978-001 (8) 010978-002 (8) #16 1
V-2030 480 3000 SE-2475 240V 750W (4) 108259-001 010978-001 (8) 010978-002 (8) #16 2
V-2040 240 4500 SE-2475 240V 750W (6) 108259-002 010978-001 (12) 010978-002 (12) #14 1
V-2040 480 4500 SE-2475 240V 750W (6) 108259-002 010978-001 (12) 010978-002 (12) #16 2