Cistermiser Vecta+ VST User manual

Vecta+ Sensor Taps
Installation Guide
VST VSMT VSS
2 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
Optional extras (Suitable for Cistermiser’s Vecta+ Sensor Tap range)
Copper inlet tube
Multi product power supply unit (PSUC)
*Low flow rate options include one flow regulator.
1
5
3
2
4
10
11
6
8
7
9
14
12
15 13
16
17
15
16
1.
Introduction
Cistermiser’s Vecta+ infrared tap range offers internal valve configurations with the Vecta+ Sensor Mixer
Tap, and external valve configurations with the Vecta+ Sensor Spout and Vecta+ Sensor Tap. The full
range uses infrared technology which ensures maximum hygiene and water efficiency.
The Vecta+ Sensor Tap and Vecta+ Sensor Mixer Tap are supplied configured with the 3.5 litres per
minute laminar nozzle installed but also include a 5 litres per minute aerator.
The Vecta+ Sensor Spout is supplied configured with the 3.5 litres per minute laminar nozzle installed
but also
includes a 5 litres per minute aerator.
Supplied parts
Vecta+ Sensor Tap
1
Tap Body
2
*3.5 lpm Nozzle - Blue (pre-fitted)
3
Aerator Housing
4
*5 lpm Nozzle - Orange
5
Aerator Gasket
6
Fixing Rod
7
Fixing Plate
8
White Fixing Gasket
9
Fixing Rod Nut
10
Tap Body O-ring
11
Inlet Hose
12
Control Box
13
Control Box mounting bracket
14
Power Transformer
15
Mounting Screw x 4
16
Wall fixing x 4
17
Sticky Pad (Power Transformer)
Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 3
1
5
3
2
4
6
8
7
9
10
11
14
12
15
13
16
17
18
19
21
20
1
3
2
4
5
6
7
8
9
10
11
12
13
14
18
19
12
13
13
Vecta+ Sensor Mixer Tap
1
Mixer Tap Body
2
*3.5 lpm Nozzle - Blue (pre-fitted)
3
Aerator Housing
4
*5 lpm Nozzle - Orange
5
Aerator Gasket
6
Fixing Rod
7
Fixing Plate
8
White Fixing Gasket
9
Fixing Rod Nut
10
Tap Body O-ring
11
Inlet Hose x 2
12
Inlet filter x 2
13
Check Valve & fitting x2
14
Power
Junction Cable
15
Battery box
16
Battery box bracket
17
Power Transformer
18
Mounting Screw x 4
19
Wall
fixing x 4
20
Sticky Pad (Power Transformer)
21
Sticky Pad (Battery box)
Vecta+ Sensor Spout
1
Spout Body
2
3.5 lpm Nozzle - Blue (pre-fitted)
3
Aerator Key
4
5 lpm Nozzle - Orange
5
Fixing Flange
6
Fixing Cover
7
Spout Fixing Screw x 3
8
Inlet Hose
9
Control Box
10
Control Box mounting bracket
11
Power Transformer
12
Mounting Screw x 4
13
Wall
fixing x 7
14
Sticky Pad (Power Transformer)
4 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
2. Installation
Single Vecta+ Sensor Tap Single Vecta+ Sensor Spout
How to change the nozzle
Use the nozzle tool (Vecta+ Sensor Spout)
or a 22mm spanner (Vecta+ Sensor Tap) to
unscrew the 3.5 litre (blue) nozzle. Insert the 5
litre (orange) nozzle and tighten until flush with
tap body; no part should be protruding from
the end of the tap. Ensure the nozzle is not
over-tightened as this may pinch the “O” ring
and cause the tap to leak.
NOTES:
• Flush pipework prior to installation
• Ensure filter in Control Box is clean
• Do not install opposite a mirror
• Minimum 0.5 Bar dynamic pressure
• Install an accessible isolating valve and TMV
upstream of the tap
• IMPORTANT. Prior to marking and drilling fixing
holes for the Vecta+ Sensor Spout, installers must
Assemble ‘Fixing Flange’ (5) and ‘Fixing Cover’ (6)
to the spout to ensure the Spout is aligned when
secured to a wall.
The tap can be mounted on any horizontal surface
10-40mm thick. It requires a hole of 28-32mm
diameter.
A spout can be mounted on a secure vertical
surface. It requires a hole of 26-32mm diameter.
Isolation ValveIsolation Valve
Inlet
Filter
Connect to
Tap/Spout
Connect to
Power Transformer (when used)
White Fixing
Gasket
Fixing Plate
Ensure brass flange is
fitted to body and spout
aligned before fitting
Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 5
Single Vecta+ Sensor MixerTap
The tap can be mounted on any horizontal surface
10-40mm thick. It requires a hole of 28-32mm
diameter.
How to change the nozzle
Use a 22mm spanner to unscrew the 3.5 litre
(blue) nozzle. Insert the 5 litre (orange) nozzle and
tighten until flush with tap body; no part should
be protruding from the end of the tap. Ensure the
nozzle is not over-tightened as this may pinch the
“O” ring and cause the tap to leak.
NOTES:
• Flush pipework prior to installation
• Ensure filters in hoses are fitted and clean
• Do not install opposite a mirror
• Minimum 0.5 Bar dynamic pressure
• Install an accessible isolating valve and TMV
upstream of the tap
• Ensure electrical connections correlate to
their matching colours. i.e. black to black or red
to red
• Ensure pre-fitted filter is retained within
flexible hose - the tap’s perfromance will be
reduced without the filter
Kinks Twists
Battery
Pack
Power
Transformer
Isolation
Valve
Check Valve
Inlet Filter
Isolation
Valve
Check Valve
Inlet Filter
Power
Junction
Cable
Battery Powered Mains Powered
White Fixing
Gasket
Fixing Plate
6 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
3. Power connections
Vecta+ Sensor Tap and
Vecta+ Sensor Spout
If using the battery case, remove battery lid and
battery compartment from the control box. Fit 4
Alkaline AA (LR-6) batteries as indicated. Replace
the battery compartment in the control box and
replace the lid.
If using the mains power, connect the power
transformer to the control box. Secure the power
transformer in a dry location using screws or sticky
pad provided and connect the un-terminated mains
cable to a 230V AC supply via a fused spur.
Both batteries and mains power can be connected
at the same time to provide battery backup in the
event of loss of power.
Vecta+ Sensor Mixer Tap
If using the battery case, remove battery
compartment lid and fit 4 Alkaline AA (LR-6)
batteries as indicated and replace the lid. Mount
the battery case in the bracket and secure with the
screws or sticky pad provided.
If using the mains power, secure the power
transformer in a dry location using screws or sticky
pad provided and connect the un-terminated mains
cable to a 230V supply via a fused spur.
Use the Power Junction Cable to connect the
power source to the tap. Ensure the colours match
red to red and black to black. Both batteries and
mains power can be connected at the same time to
provide battery backup in the event of loss of power.
CAUTION:
Risk of electric shock. Isolate supply before
working on wiring.
Connect to
Tap/Spout
Connect to
Power Transformer
Power
Transformer
Black to
Black
Power Junction
Cable
Connect to
Mixer Tap
Battery Box
Battery Box and
Power Transformer
can be connected at
the same time
Red to
Red
Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 7
Multiple power connections for Vecta+ Sensor Taps & Spouts
If installing multiple Cistermiser products the PSUC Multi Product Power Supply Unit is available as
an accessory. Contact Cistermiser for more details.
Supply up to 10
Vecta+ outlets
230V Supply
Isolation
Valve
Isolation Valve Isolation Valve
8 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
Minimum operating pressure: 0.5 bar (dynamic)
Maximum operating pressure: 6 bar (dynamic or static – whichever is highest)
Factory settings
Range: ~18cm
Run-on time: 2 sec
Battery life: 2 years in normal conditions with recommended batteries.
A single red flashing of the LED indicates that the batteries
are low and need to be replaced.
Cleaning: Clean with non-abrasive cleaner and water only.
Lens care: Infrared lens can be polished with a soft cloth.
Electronic specification
Power transformer: 100-250V AC 50/60Hz 0.2A MAX
Control Box / Mixer Tap: Supply: 6VDC 1A MAX (batteries or power transformer)
Ambient temperature range: Operating: 0 to 40°C
Storage: -25 to 40°C
Features
Non touch: The water is activated when hands are presented in front of the
infrared sensor.
Safety shutoff: After 60 seconds of continuous water activation via sensor
detection, the tap will automatically stop to reduce the risk of
flooding.
Smart shutoff: During a power cut, the device will automatically switch off the
water flow to reduce the risk of a flooding event.
4. Usage advice & specification
Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 9
NOTE:
• Valve may fail to operate at under 0.5 bar
dynamic pressure.
Flow Rate (litre/min)
8
7
432
6
5
4
3
2
5
1
0
1
Flow rate chart
0
Vecta+ Sensor Tap & Vecta+ Sensor Spout
110mm
83mm
G1/2
G1/2
207mm
ø38mm
111mm
49mm
10~40mm
600mm
83mm
50mm
108mm
243mm
5. Component dimensions
Supply pressure (bar)
5 litres per minute aerated (orange)
3.5 litres
per minute non-aerated (blue)
10 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
Vecta+ Sensor Mixer Tap
111mm
49mm
10~40mm
600mm
NOTE:
• Valve may fail to operate at under 0.5 bar
dynamic pressure.
Flow Rate (litre/min)
Supply pressure (bar)
8
7
432
6
5
4
3
2
5
1
0
1
Flow rate chart
0
69mm
64mm
83mm
50mm
108mm
5 litres per minute aerated (orange)
3.5 litres
per minute non-aerated (blue)
Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 11
6. Frequently asked questions
Normal operation
During normal operation, when the user brings their hand within 18cm of the sensor it will flash red once
and water will flow from the nozzle. When the user removes their hand from the sensing distance, the
water flow will stop.
Fault Observation Action
No water
from tap
The sensor is flashing red
continuously after hand is
placed in sensing range
Low battery. Change batteries.
The sensor is not flashing
at all when hands are in
sensing range
Battery power: Low battery. Change batteries.
Mains power: Poor DC contact. Check power
transformer connection.
The sensor flashes red
once when hands are in
sensing range
Water supply. Ensure water supply has been
turned on and there is good working pressure.
Minimum dynamic pressure 0.5 bar.
Filter blockage
Vecta+ Sensor Tap or Vecta+ Sensor Spout:
Check filter in flexible hose.
Vecta+ Sensor Mixer Tap: Check filter in inlet to
solenoid valve.
The sensor is covered
Anti-vandal mode has been triggered. The
object/debris needs to be removed and the tap
will resume normal functionality.
Continuous
flow of
water or
dripping
from the tap
Water is flowing when
no user is present
Water supply. Ensure water pressure is between
0.5 bar and 6 bar.
Filters: Ensure filters are clear, clean if required.
Vecta+ Sensor Tap and Spout filter is in inlet to
control box. Vectra+ Mixer Tap filter is in flexi-
hose fitting.
Debris in solenoid valve: Contact Cistermiser.
12 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
Cistermiser product warranty and extended warranty
Cistermiser products are guaranteed for
12 months from the date of manufacture.
The guarantee is for faulty products and parts
only: there is no labour warranty. If you believe
your product is faulty, please either contact
Cistermiser directly on 0118 969 1611 or at
[email protected], with a
photograph and the serial number, to help
diagnose the cause of the problem.
The warranty on Cistermiser products
can be extended within one year of date of
manufacture, at no cost, to three years from
the date of installation. Please make a note
of the serial number and take a photograph
of the installation before you leave site.
Fault Observation Action
Water flow
diminishes
The sensor flashes red
once when hands are in
sensing range
Filter is blocked with scale or debris.
Vecta+ Sensor Tap or Vecta+ Sensor Spout:
Check filter in the inlet to the solenoid.
Vecta+ Sensor Mixer Tap: Check filter within
the flexible connector.
Aerator is blocked with scale or debris.
Vecta+ Sensor Spout: Remove aerator from the
tap using the key supplied, clean and reinstall.
Vecta+ Sensor Tap or Vecta+ Sensor Mixer
Tap: Remove aerator with appropriate tools,
clean and reinstall.
Inconsistent
flow rate
The sensor flashes red
once when hands are in
sensing range
TMV / water pressure issue: Ensure water supply
to TMV is balanced and pressure is suitable for
TMV specification.
Water is
always cold
The sensor flashes red
once when hands are in
sensing range
TMV / water pressure issue: Ensure water supply
to TMV is balanced and pressure is suitable for
TMV specification.
Ensure hot water pipes are insulated to minimise
cold dead legs.
Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 13
No. Activity Checked Date
1. Flush pipework prior to installation.
2.
Ensure filters are fitted to the supplied pipe work.
3. Ensure water supply working/dynamic pressure is between
0.5 – 6 bar.
4. Check product flow-rate suitability to application.
5. Check all connections for leaks; ensure isolation valve is installed.
6. Check flexible hose is not kinked/twisted.
7. Vecta+ Sensor Mixer Tap and Vecta+ Sensor Spout:
check flow direction of solenoid valve.
8. Check electrical connections. Ensure either mains or battery power
or multi product power supply unit is connected.
Product serial number
Installation address
Installer’s name
Telephone number
Email address
Commissioning check-list
The warranty on Cistermiser products can be extended within one year of
date of manufacture, at no cost, to three years from the date of installation.
Once the valve has been installed, complete the product commissioning
checklist below to demonstrate compliance with the installation instructions.
Email a photograph of this completed form to warranty@cistermiser.co.uk
or post to Cistermiser, Unit 1, Woodley Park Estate, 59-69 Reading
Road, Woodley, Berks, RG5 3AN.
3YEAR
warranty
extended
14 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
Urinal flushing
Hydraulic Control Valve
An automatic urinal flush
control valve which reduces
water consumption. The valve
uses a simple patented
mechanism which prevents
water waste by ensuring that
the auto-flush cistern is only
filled, and can only flush, when
the washroom is used.
Infrared Control
(IRC™) Valve
This valve automatically
manages the water supply to
the urinal cistern and reduces
water consumption by up to
80%. The PIR sensor detects
movement and activates the
solenoid valve, allowing water
into a urinal cistern.
Direct Flush Valve
An infrared sensor controlled
urinal valve. It automatically
flushes individual urinals after
use, ensuring the highest level
of hygiene from the minimum
volume of water.
WC flushing
Easyflush Wave
An infrared, hands-free and water-conserving
WC cistern flush valve suitable for concealed or
exposed cisterns. Easy to install in retrofits or
new installations, its no-touch dual flush WC
cistern valve promotes water economy and
hygiene in domestic and commercial
washrooms.
Easyflush Direct
An infrared electronic flushing system that
removes the need for a WC cistern by taking its
water feed straight from the mains supply. Ideal
for high traffic areas as the system allows for a
second flush without a delay.
Cistermiser range
Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 15
Washroom control systems
Sensazone
An innovative system to conserve water
and energy. Occupancy is monitored by
sensors; when someone enters the washroom
all services controlled by Sensazone are
activated – the hot and cold water, lighting
and extractor fans.
LinkThru
LinkThru TMU delivers remote real-time
monitoring of water temperatures on a 24/7
basis. LinkThru TMU harnesses the power of
the Internet of Things to monitor water
temperatures and helps to ensure Building
Owner compliance with HSG274, reducing the
risk of Legionella.
Infrared Taps
Novatap
A contemporary deck-mounted chrome tap.
The infrared control reduces water and energy
usage and eliminates the risk that the tap may
be left running.
Vectatap
An elegantly designed infrared tap with
the benefit of hygienic hands-free operation.
Vectatap improves water and energy efficiency
and includes auto-shut off and hygiene flush
features.
Salamander is one of the UK’s leading
manufacturers of pumps for boosting
water pressure for showers, bathrooms
and whole house supply in domestic and
small commercial tank-fed systems.
salamanderpumps.co.uk
Keraflo manufacture delayed action float
valves, which provide an accurate and
effective method of controlling the level
of stored cold water in tanks both with
and without raised float valve chambers.
The range is used in domestic, commercial
and industrial applications worldwide.
keraflo.co.uk
Combimate is a domestic limescale
prevention device that prevents limescale
build-up and soft water corrosion in
combination boilers and other domestic
hot water appliances.
combimate.co.uk
Talon is the UK market leader in the
manufacture and supply of plastic pipe
clips, pipe collars and fixing plugs, plus
a range of cover profiles for concealing
pipework.
talon.co.uk
Cistermiser Limited
Unit 1, Woodley Park Estate, 59-69 Reading Road,
Woodley, Reading, Berkshire RG5 3AN
t: +44 (0) 118 969 1611
e: sales@cistermiser.co.uk
cistermiser.co.uk
A Davidson Holdings company
Davidson Holdings’ brands
IRT/145 Rev3

This manual suits for next models

2

Other Cistermiser Plumbing Product manuals

Cistermiser Easyflush EVO 1.5 User manual

Cistermiser

Cistermiser Easyflush EVO 1.5 User manual

Cistermiser Easyflush Direct User manual

Cistermiser

Cistermiser Easyflush Direct User manual

Cistermiser Novatap User manual

Cistermiser

Cistermiser Novatap User manual

Popular Plumbing Product manuals by other brands

Polaris AutoClear PAGTF45 user manual

Polaris

Polaris AutoClear PAGTF45 user manual

Wellis Aurum ACS0317 instruction manual

Wellis

Wellis Aurum ACS0317 instruction manual

Spectrum Brands Pfister Venturi 8P8WS-VNS Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Venturi 8P8WS-VNS Quick installation guide

Kohler K-1167 installation guide

Kohler

Kohler K-1167 installation guide

Hans Grohe AXOR MyEdition 230 47020 1 Series Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe AXOR MyEdition 230 47020 1 Series Installation/User Instructions/Warranty

Kohler K-15175 installation guide

Kohler

Kohler K-15175 installation guide

Kohler K-24804-4N-CP installation guide

Kohler

Kohler K-24804-4N-CP installation guide

Ponsi Rubinetterie Toscane Minimini Series Instructions for installation

Ponsi Rubinetterie Toscane

Ponsi Rubinetterie Toscane Minimini Series Instructions for installation

Grohe Tectron 37 324 installation instructions

Grohe

Grohe Tectron 37 324 installation instructions

Marco MIX 1000879FB instruction manual

Marco

Marco MIX 1000879FB instruction manual

Hansgrohe Axor Starck Series Instructions for use/assembly instructions

Hansgrohe Axor

Hansgrohe Axor Starck Series Instructions for use/assembly instructions

baliv WT-5620 manual

baliv

baliv WT-5620 manual

Olympia P-230XT Installation

Olympia

Olympia P-230XT Installation

Tylo Space Vision 250 Assembly instructions

Tylo

Tylo Space Vision 250 Assembly instructions

Kohler K-7127 installation guide

Kohler

Kohler K-7127 installation guide

Franke F5EM1005 2030031350 Installation and operating instructions

Franke

Franke F5EM1005 2030031350 Installation and operating instructions

Moen Waterhill S411BN Illustrated parts list

Moen

Moen Waterhill S411BN Illustrated parts list

newform LINFA 67082C Instructions and guarantee

newform

newform LINFA 67082C Instructions and guarantee

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.