CKD SHD3025 User manual

SM−13024−A
INSTRUCTION MANUAL
SUPERHEATLESSAIRDRYER
SHD3025
SHD3045
SHD3075
SHD3100
SHD3125
SHD3150
SHD3200
SHD3240
●
Please read this instruction manual
carefully before using this product,
particularly the section describing safety
.
●
Retain this instruction manual with the
product for further consultation whenever
necessary
.
DEC-2112thedition
CKDCorporation

<SM-13024-A>
TableofContents
1. INTRODUCTION
1
2.
SAFETYINSTRUCTION
2
3. CAUTIONS
3-1
Formalities when installed Super Heatless Dryer
3
3-2
Cautions at operation
3
4. INSTALLATION
4-1
Check items before installation
4
4-2
Transportation
4
4-3
Installation place
5
4-4
Air piping
5,6
4-5
Drain piping
6
4-6
Electric wiring
6
5. OPERATION
5-1
Operation
7
5-2
Operation stop
8
5-3
Energy saving unit
8,9
5-4Noloadoperation 9
5-5Alarmoutlet 9,10
5-6Remoteoperation 10
5-7Operationoutput 11
5-8Parametersettingcharge11,12
6. MAINTENANCEANDINSPECTION13
6-1
Replacement of desiccant vessel
14
6-2
Replacement of silencer
14
6-3
Replacement of dew point sensor
15
7. TROUBLESHOOTING
16,17
8. ATTACHEDREFERENCES
8-1
Specifications
18
8-2
Outside drawing
19
8-3
Internal structure drawing
20
8-4
System diagram
21
8-5
Electric circuit diagram
22,23
8-6
List of spare parts
24,25

<SM-13024-A>
1
Thankyouverymuchforpurchasingourheatlessairdryer,SHDseries.
Thismanualexplainsbasicpointsofinstallation,operation,etc.tohaveour
dryersperformattheirbest. Besuretoreadthismanualbeforeusingyourdryer.
Keepthisbooklethandyforquickreference.
Please be advised in advance that there may be some discrepancies between
products and contents of this book due to improvement of specification after
printing.
1.INTRODUCTION

<SM-13024-A>
2
Safetyinstructions
Thismanualisintendedforpersonnelwhoarefamiliarwithbasicknowledgeaboutelectricity,compressedair,fluid,
piping,andrefrigerant.CKDshallnotbeheldresponsiblefortroublesoraccidentsthatresultfrominstallation,
operationorrepairsmadebypersonnelwhoarenotqualifiedortrainedfortheabovesubjects.
Improperhandlingmaycausethemachinenottobeoperatedatitsmaximumperformancelevelorleadtoaccidents
orpersonalinjury.
AlwaysconfirmthemachinespecificationandoperatethemachineinthecorrectmannerdesignatedbyCKD.
Thismachineisequippedwithvarioussafetyandotherprotectivedevices.
However,improperhandlingofthemachinemaycausepersonalinjuryand/ordamagetothemachine.Readthis
operationmanualcarefullyandfullycomprehenditscontentsbeforeoperation.
Readthecontentsofthefollowingwarninglabels,aswellascautionsstatedintheoperationmanual,andfollowthe
instructionscontentedtherein.
Keepthisoperationmanualnearthemachinewhereallconcernedpersonnelhaveeasyaccesstoit.
Safetyprecautions
Safetyprecautionsareclassifiedintothefollowinggroups,
WARNINGandCAUTION.
WARNING CAUTION
ThisdenoteshazardswhichCOULDresultinseverepersonalinjuryordeath,if
notavoided.
WARNING
ThisdenoteshazardswhichCOULDresultinminorpersonalinjuryand/orproduct
orpropertydamage,ifnotavoided.
CAUTION
Thismachineisdesignedforindustrialuse.Alwayscarefullyhandlethemachineinthecorrect
manner.
WARNING:
ELECTRICAL SHOCK
★
Power supply terminal box, switches, etc. may cause you electrical
shock.
●
Be sure to turn off the power before inspection. Do not operate the
dryer with your wet hands.
★
Be sure to connect earth to prevent electrical shock.
CAUTION
:GROUND CONNECTION
★
You could fall if you climb on the panel.
●
Do not climb on the panel.
CAUTION:
FOOT HOLD

<SM-13024-A>
3
3-1.Formalities when installed Super Heatless Dryer
Super Heatless Dryer is classified
Pressure vessel
subject to
Safety Regulation of Pressure
Vessel
.
Safety Regulation of Pressure Vessel
As models SHD3075- SHD3240 are applied as
Second Class Pressure Vessel
according to
Boiler and Pressure Vessel Safety Regulation
by legislation of Ministry of labor, they are
accompanied by a certificate for withstanding pressure of the Second Class Pressure Vessel.
During use of this machine, keep this certificate in your possession.
3-2.Cautions at operation
1) Do not use the dryer to remove humidity of except compressed air.
*Breakdown, explosion, or fire may result.
2) Install an earth leakage breaker on the power supply.
*Electric shock may result.
3) Need to earth wiring.
*Causes of an electric shock or a fire.
4) Operate the dryer within specification ranges.
*Operation may stop abnormally, or the product’s service life may be shortened.
*When the working pressure range is low, it is not likely to be able to start.
5) Do not turn on the power switch without enclosures.
*Electric shock or heat injury may result.
6) Do not remodel this dryer.
*Break-down or shorter life time of the product may result. If you did, the warranty is
expired.
7) Remote start terminal (11-13 or 12-13) is alternate non-voltage input.
8) Do not operate local-remote switch during operation.
*It becomes the cause of stop.
9) Do not touch any parts, wires, terminals or piping in side of the dryer.
*Causes of an electric shock or a fire.
10) If emergency stop occurs during operation, remove the cause of abnormal conditions referring to
the trouble shooting.
*If the emergency stop occurs repeatedly, this may cause the dryer to malfunction.
11) Do not use the dryer for pneumatic caisson shield or respiratory medical equipment.
*It could cause an accident includes injury.
12) Do not use the dryer for transportation devices such as automobile, ship etc.
*Vibration could be a cause of break down of the internal components.
3.
CAUTIONS

<SM-13024-A>
4
4-1Checkitemsbeforeinstallation
Checkthecontentsstatedonthenameplate,such
asmodelNo.andspecifications.
Attacheddocuments
Instructionmanual(thisdocument)・・・1copy
Pressure-proofcertificate
(ExceptforSHD3025/3045)・・・・1copy
AirFilter ・・・・・・・・・・・・・・・・・・・・・・・2pieces
Tool(See6-1) ・・・・・・・・・・・・・・・・・・1piece
4-2Transportation
1)
Never lay down this product or apply any vibration or
impact to the product during transportation. Failure to
dosomaycausedamagetointernalcomponents.
2)
Do not step on this product or place any object on it.
Doingsomaycausepersonalinjury.
3)
Donotliftupthisproductusingthehandleonthetopof
thedesiccantvessel. Doingsomaycausedamagetothe
mainbody.Transportthisproductproperlyusingthefork
holesinthebase.
4.
INSTALLATION

<SM-13024-A>
5
Filter Valve
Totheend
Fromthecompressor
4-3Installationplace
1)
Installthisproductinaplacewheretheambient
temperatureis0to40 C.
2) Installthisproductonaleveledfloorwhereany
vibrationdoesnotexist.
Whenafloorisnotlevel,distortionmayarisefor
aproductandfaultmayoccur.
3)
Ifthefoundationoftheinstallationplaceisweak,
carryoutthefoundationconstructionwork.
4)
Keep the following space for the maintenance
andinspectionwork.(600mmormore).
5)
Securethisproductfirmlyusinganchor boltssothattheproductisnotlaiddown ifan
earthquakeorasuddenimpactoccurs.
6)
Do not install this product in an outdoor place. This product does not have any
water-proofstructure.Ifrainwaterissplashedontotheelectricalsystem,earthleakageor
fireaccidentmayoccur.
7)
Donotinstallthisproductinaplacewhereitisnotexposedtothedirectsunlight,particle
dust, or heating element, or any corrosive gas, explosive gas, flammable gas, or
combustiblematerialdoesnotexist.
*Breakdown, explosion, or fire may result.
8)
Compressedairshouldnotflowbackwardsforfilterprotection.
9) Waterdropmaydispersefromtheexhaustsilencerofdryerrarelyundertheinfluenceof
ambienttemperatureetc.Installdrainpanetc.inthatcase.
10) Donotmixwaterdropinairinlet.Performancenotonlygetsworse,butitbecomesthe
causeoffailure.Whenthereisapossibilitythatwaterdropmaymix,installaftercooleror
refrigeratedairdryerintheupstreamofthisequipment.
4-4Airpiping
1)
Alwaysstartthepipingworkaftercheckingtheairinletandoutlet.
2) AttachtheairfilterM-seriessuppliedwiththeproducttotheairinlet. Inaddition,when
thequalityofairflowinginisbad,attachanoptionalfilterbeforetheMseriesconcerned.
3) AttachtheairfilterP-seriessuppliedwiththeproducttotheairoutlet.Inaddition,whena
visitor'squalityofdemandairishigh,attachanoptionalfilterafterthePseriesconcerned.
4) Sincemoisturemaycondensewithinpiping,thedistancebetweenairfilterMseriesand
theentranceofmainpartissetto1morlessasastandard.
5)
MakethedistancebetweentheairfilterM-seriesandtheinletofthemainbodyasshort
aspossiblesincewatercontentsmaybecondensedinsidethepiping.
6)
If the flow inside the piping cannot be shut down
whenstartingthemaintenanceandinspectionwork
ofthemainbody,installabypasscircuithavingthe
stopvalve.
7)
Carefullydesignthepipingroutesothattheweight
ofthepipingisnotappliedtothemainbody.

<SM-13024-A>
6
8)
Alwaysusethepipingwithstandingtheworkingpressureandtemperature. Carryoutthe
pipingworksothatnoairleaksfromtheconnectionpart.
9) For piping materials, use galvanized or stainless pipes. Before connecting the piping,
alwaysperformtheflushingsothatnodustenterstheaircircuit.
4-5Drainpiping
1)
Use a tube with an inside diameter ofφ6 or more for the drain piping of the air filter.
Openthedischargeendtotheatmosphere.
2)
Ifthedrainpipingrisesoristoolong,thebackpressureisapplied,causingthedrainnotto
bedischarged. Alwayscarryoutthedownwardpipingsothatthedrainflowsnaturally.
3)
Thedrainisnormallydischargedbytheairpressure. Alwayssecurethedraindischarge
tubefirmlysothatitdoesnotdeflectwhenthedrainisdischarged.
4)
Ifoilismixedwiththedrain,anappropriatewastewatertreatmentisrequired.Forwaste
watertreatment,consultwithyournearestindustrialwastedisposalcompany.
4-6Electricwiring
1)
Alwaysoperatetheproductataproperpowervoltage.
Operatetheproductatavoltagerangeofratedvoltage ±10%orless.
2)
Mount a circuit breaker for overload protection and earth leakage shut down (rated
current:5A,sensitivitycurrent:30mA)onthemainpowersupply.
3)
Connectionofpowercable
Make ahole in the rubber bushing at the upper portionof the side panel of the main
body,throughwhichtheelectriccablesandwiresarepassed.
Connect the earth leakage circuit breaker to the terminal block L1 and L2 inside the
mainbody.
4)
Connectionofgroundingcable
ConnectthegroundingcabletotheterminalblockPEinsidethemainbody.
Neverconnectthegroundingcabletoanycitywaterpipe,gaspipe,andlightningrod.
5)Insulationresistanceandwithstandvoltagetest
Don't performinsulationresistanceandwithstandvoltagetest.Carrieddewpointmeter
andtemperatureandhumiditysensoraredamaged.
When you carry out unavoidably, carry out after removing dew point meter and
temperatureandhumiditysensor.
Terminalbox

<SM-13024-A>
7
5-1Operation
1)
Make sure again that the air piping, drain piping, and electric
wiringhavebeenconnectedproperly.
2)
Closetheoutletandinletvalves,andthebypassvalve.
3)
TurnONthemainpowersupply. Anumericvalueisshownon
DEWPOINT. Thisvalueshowsthedewpointatthattime.
4)
Slowly open the inlet valve to sufficiently pressurize the main
body. Twopressuregaugesshowthesamepressurelevel.
5) Since inlet valve may have closed when pressure is not improved,
even if it introduces air, even when it is troublesome, open manual
valve in front panel. If it works normally, be sure to close manual
valve.(Domeasuressameastheaboveintherebeingthethingthat
the inlet valve of both vessels closes it at the time of
re-pressurization when you skipped pressure in the dryer without
stopping it by STOP button or when you did START in less than
0.4MPa.)
6)
Aftercheckingthatthepressurelevelis0.4MPaormore,press
theSTARTbutton.
7)
Check that the left and right desiccant vessels are switched
alternatelyatintervalsof2min.
8)
Iftheproducthasnotbeenusedforanextendedperiodoftime,
the desiccant may get damp
.
Close the outlet valve and carry
out the regenerationpurge forseveralhours while referring to
DEWPOINT.
9)
Whenthedewpointbecomesclosetotherequiredlevel,slowly
opentheoutletvalvetoflowthecompressedair.
10)Duringoperation,when thepowersupplyreturniscarriedout
aftertheformerpowersupplywasshutoffbypowerfailureetc.,
operation is resumed. But the phenomenon that informed 5)
clausesmayoccurwhenpressureinthedryerislessthaninlet
pressurerange.
11)Ifyouuseitunderbytheselectedpressure,sinceyoumaybe
unable to demonstrate aperformance, please use it abovethe
surelyselectedpressure.
12)Becarefulthatthedewpointwillnotbestabilizedifusingflow
rateischangedsharply.
13) At thetimeoftestrunstartingafterthismachineinstallation, pass
about10-20%offlowrate,andoperatethefollowingtime.
5
.
OPERATION
Manual
valve
(2portvalve)

<SM-13024-A>
8
Pressuredewpoint(℃)
(NOTE)
-20 -30 -40 -60
(reference)
Atmosphericdewpoint
(℃) -40 -48 -57 -74
Time(h) 6 12 24 72
NOTE:Pressuredewpointis0.7MPa.
14) Sinceithassetupbeforehand,donottouchtheneedlevalve(referto6-3clause)attachedtothe
dewpointsensorlowerpart.
5-2Operationstop
1)
Closetheinletandoutletvalves.
2)
PresstheSTOPbutton.DEWPOINTisstilldisplayedevenatthistime.
3)
TurnOFFthemainpowersupply.
4) Sincedryerpassesairalsoduringastop,besuretocloseinletandoutletvalve.
5-3Energysavingunit
Thisproductisequippedwithanenergysavingunitasastandardaccessory. Thefollowing
showstheoutlineoftheenergysavingunit.
1)
TurnONorOFFtheenergysavingunitusingthe ECOMODEbutton. Whentheenergy
savingunitispoweredON,theindicationlampislit.Additionally,thelampislittoshowthe
dewpointvalue,whichissetatthistime.
2)
To change the set dew point, keep the ECO MODE button pressed for 2 sec. with the
energysavingunitturnedOFF([ECO]lampisoff.).Since ECOMODEblinksinthatcase
anditdisplaysthatachangeispossible,pleasebesuretocheckblinking.Whenpressing
theSTOPbuttoninthisstate,thenumericvaluecanbechanged.Whenadesirednumeric
valueisshown,presstheECOMODEbuttontosetthisvalue.(Blinkingchangestolighting.)
3)
ThedewpointsetfortheG-type(standardtype)isdifferentfromthatsetfortheM-type
(high-gradetype).
Pressuredewpoint
-10℃ -20℃ -40℃ -60℃
G-type
○ ○ ○
M
-type
○ ○ ○
4)
Thedewpoint,atwhichtheoperationisactuallychangedtotheenergysavingoperation,is
set at a level slightly lower than the set dew point level. Therefore, the energy saving
operationisnotstartedatthesetdewpoint.
-10℃setting -20℃setting -40℃setting -60℃setting
Dewpointchangedto
energysaving
Lessthan-14℃ Lessthan-24℃ Lessthan-44℃ Lessthan-64℃
Dewpointwhich
energysavinggoesout
Over-12℃ Over-22℃ Over-42℃ Over-62℃
5) If the flow consumption is small,the dewpoint does not become worse with the energy
saving operation started. At this time, the operation is forcibly returned to the normal
operationafter1hourhaselapsed.

<SM-13024-A>
9
6)
ThesensorusedfortheG-typeisdifferentfromthatfortheM-type.
G-type
Temperature and humidity
sensor
Inparticular,theaccuracybecomesverybad
in the low dew point area (standard use).
Troublemayoccurinenergysavingoperation
by the case at the time of -40 ℃
specification.
Approximately+20
Cto
-
45
C
M
-type
Dewpointmeter
Themeasurementcanbeperformedwith
ahighaccuracyintheentirearea(±2 C
atdewpoint>-60 C)
+20℃ to-80℃
7)
Whentheenergysavingoperationisstarted,theECOlampislit,thepurgeisstopped,and
both vessels A and B are pressurized. The desiccant vessels are not switched and the
currentstatusiskept. (Theswitchingtimeisextended.)Whentheoperationisreturnedto
thenormaloperation,theECOlampgoesoffandthepurgeisrestarted.
8) Werecommendyoutomakeittheenergy-savingsettingdewpointinthesamenumerical
valueastherateddewpointselectedinmodel.Becareful,sincethedisposalofreducing
inletflowisneededincasethesettingdewpointischangedmoreintoalowdewpointside.
9) If24hoursafteroperationstartpass,energysavingratecanbedisplayedtodisplaypart
asnumericalvaluebypushingSTARTbuttonduringoperation.Useformanagementevery
day.Inaddition,becareful,sinceitcannotbeusedduringstop.
ENERGYSAVINGRATE=1-(PURGETIMEINENERGYSAVING)/(PURGETIMEINRATING)
5-4Noloadoperation
After purchase, or when there is little air consumption by the side of secondary, and
energy-savingoperationhasnotbeencarriedout,thesurfaceoutsidethedesiccantvessels
may get cold and may dew or freeze. This is a phenomenon which happens at the time of
desiccant reproduction, and is not alarm. If you put in energy-saving equipment, dew
condensationwillstopbeingabletooccureasily.
5-5Alarmoutlet
Thisproductisequippedstandardlywiththealarmsignaloutput.Inaddition,whenthepower
supplyisnoton,itshowsyouasalarm.
1) Alarmsensor
① Disconnectionofasensoretc.showsyouwithanon-voltagecontactoutput(alarmtime)
anddisplayingthedewpointdisplaypartofanoperationpanel as"A01"afterstarting,
However,mainpartdoesnotstop.Itwillbecanceledifitreturnstonormal.Inaddition,
afterpushingSTOPinthestateoftheabnormalitiesinasensor(A01display),evenifit
pushes START, it does not start. It will start, if START is pushed after canceling
abnormalities or making it reset (it is 2-second length aggressiveness about START).
(Sinceresetcannotdoatthetimeofremoteoperation,performreset,oncechangingto
localoperation.)

<SM-13024-A>
10
② Keep in mind that the contact capacity of the relay for an output and the minimum
applicationloadareshowninthe 「8-5electriccircuitdiagram」.
2) Alarmdewpoint
① To the energy-savingsetting dew point, if it becomes +2 degrees C, alarm dew point
showsyou with a non-voltage contact output (alarm time) and blinking the dew point
valueofthedewpointdisplaypartofanoperationpanel.However,amainpartdoesnot
stop. If the dew point returns within normal limits, abnormalities will be canceled
automatically.(See 「5-8Parametersettingchange」 incaseofchangingdewpointalarm
settingvalue.)
Energy-savingsettingdewpoint -10℃ -20℃ -40℃ -60℃
Alarmdewpoint -5℃ -15℃ -35℃ -55℃
Moreover,analarmoutputissentwiththedewpointsettingvalueusuallyturnedonat
thetimeofthelastenergy-savingoperationatthetimeofoperation(whenthedewpoint
settinglampisoff).
② Since,asforimmediatelyafteroperation,thedewpointisbadinmanycases,dewpoint
alarmoutputisnottakenoutforabout12hoursafteroperation.(See 「5-8Parameter
settingchange」 incaseofchangingtimesettingvalue.)
③ Keep in mind that the contact capacity of the relay for an output and the minimum
applicationloadareshowninthe 「8-5electriccircuitdiagram」.
④ Evenifformerpowersupplyison,anddewpointgetsworseatthetimeofdryerstop,
alarmdewpointdonotoutput.
⑤ Alarmdewpointsentduringoperationiscontinuedsendingafterstop.Itisresetatthe
timeofre-operation.
5-6Remoteoperation
1) PleaseswitchtheswitchinacontrollersidetoREMOTE.The
REMOTElampofanoperationpanelsidelightsup.
2) Please wire a proper terminal after checking power supply
voltagebasedon 「8-5electriccircuitdiagram」.
3) Keep in mind that the "start" and "stop" button of an
operationpanelsidedoesnotworkduringremoteoperation.
4) Dryer is stopped after changing to LOCAL. by change switch
duringremoteoperation. Changeswitch
<
Controller side
>

<SM-13024-A>
11
5-7Operationoutput
1) Non-voltagecontactoutputclosedduringoperationisequippedstandardly.Wireproper basedon
「8-5Electriccircuitdiagram」.
2)
Keep in mind that the contact capacity of the relay for an output and the minimum
applicationloadareshowninthe 「8-5electriccircuitdiagram」.
5-8
Parametersettingchange
1) When you change a setup of a control board unavoidably, Change carefully in the
followingprocedures.
① StopthismachinewiththeSTOPbutton.
② PushingtheSTOPbuttonpreviously,pushtheECOMODEbuttonfor5seconds.
③ Adisplaypartissetto and blinks.
④ Themeaningofadisplaynumberisshownbelow.
NO
Display
number
Contents
1
Thedewpointexcludeden
ergysavingatthetimeof
10℃ setup
Over-12℃
2
Thedewpointincludedinenergysavingatthetime
of 10℃ setup
Lessthan
-14℃
3
Thedewpointexcludedenergysavingatthetimeof
20℃ setup
Over-22℃
4
Thedewpointincludedinenergysavingatthetime
of 20℃ setup
Lessthan
-24℃
5
Thedewpointexcluded
energysavingatthetimeof
40℃ setup
Over-42℃
6
Thedewpointincludedinenergysavingatthetime
of 40℃ setup
Lessthan
-44℃
7
Thedewpointexcludedenergysavingatthetimeof
60℃ setup
Over-62℃
8
Thedewpointincludedinenergysavingatthetime
of 60℃ setup
Lessthan
-64℃
9
Factoryset
(Donttouch)
10 .
11 .
12 .
13 .
Display part

<SM-13024-A>
12
14 .
Dew point alarm value
(
A difference with the dew point
to which energy saving goes out is shown.
)
7℃
difference
15 .
Factoryset
(Donttouch)
16 .
17 .
18 .
19 .
Timenottotakeoutadewpointalarmoutput
12hours
⑤ SinceadisplaychangesfromNo1toNo19wheneveritpushestheECOMODEbuttonevery1
time,changetotheitemwhichmakesasettingchange.
⑥ Sincethenumberofblinkincreasesonebyone,thenextof"9"issetto"0"anditcomesto
increaseagainbypushingtheSTARTbuttononce,changetothenumberofhope.
⑦ PushtheSTOPbutton,whenyouchangethebeamofblinknumber.Wheneveritpushes,central
numberandrightnumberblinkbyturns.Thenumberwhichblinkedcanbechangedlike ⑤.
⑧ Ifitissetasthenumericalvalueofhope,ECOMODEbuttonisrepeatedandpushedagain,and
returntoadewpointdisplay.Asetupisanendabove.
⑨ PushandreboottheSTARTbutton.
2) Setupofadewpointalarmvalue setsupdifferencewiththedewpointtowhichenergysaving
goesout.(ThedewpointsetupinNo.1,3,5and7)
(Example: 「42-7=35」-35℃ becomesasettingvalueatthetimeof40℃ setup.Ifdewpointalarm
valuesetupischanged,setupofalleachenergysavingdewpointwillchangesimultaneously.
3) Dont change the parameter of factory set by any means. Once intercepting a power supply
completelyatthetimesatthetimeofchangingaccidentallyetc.Supplypowersupply,pushingthe
STOPbuttonandtheSTARTbuttonsimultaneously.Anallclearanceiscarriedoutanditreturns
tothesamestateasthetimeofpurchase.

<SM-13024-A>
13
Periodicinspection
Carry out the following inspections to operate this product at its optimal operating level,
preventatroublebeforehand,andoperatetheproductcorrectlyforanextendedperiodoftime.
If any inspection item is satisfied, take appropriate actions while referring to section 5.
Troubleshooting.
Inspectionlocation Inspectionitem
Inspectionfrequency
Every
day
Every
week
Every
month
Halfa
year
[RUN]lamp [RUN]lampislit
○
Dewpointdisplay Dew point is
displayed.
○
Indicator for differential
pressure between pre-
andafter-filter.
Do not enter the
redzone.
○
Note:Atthetimeofmaintenance,stopdryer,andcheckthatthereis
no pressure with a pressure gauge, and also extract residual
pressureinfilterfromfilterlowerpartoftherightfigure.
6
.
M
AINTENANCEANDINSPECTIO
N
Extractresidualpressure.

<SM-13024-A>
14
Silencer
Silencer
media
6-1Replacementofdesiccantvessel
Aspring,desiccant,porousplate,filter,etc.areassembledintothedesiccantvessel,andthis
desiccantvesselismountedonthemainbody.Thedesiccantvesselneedstobereplacedat
reference intervals of 2 years. since it has shown the of desiccant
exchange method to 「8-6 list of spare parts」, it is chosen of a
visitor.
1)
Stoptheoperationwhilereferringtosection5-2,Operation
stop.
2)
Loosen the lock set screw at the lower portion of the
desiccantvesselandslideitdownward.
3)
Turnthedesiccantvessel45 andpullitoutupward.
Note)Ifthevesseldoesnotmovesteadilyandthecylinder
cannotrotate,pushthetoolattachedtotheproductintothe
gapasshownontheright.Whenthepressureremains,the
pressure is released and the cylinder moves steadily,
allowingittorotate.
(Relievethepressureremainingintheshadedarea)
4) Please exchange by the selected drier
exchangemethod.
5)
CheckthattheO-ringismountedonanew
desiccant vessel and that the grease is
appliedtotheO-ring. Mountanewvessel
inthereverseorderofdisassembly.
6)
After the new vessel has been mounted
completely, slide the lock upward and
securethelockusingthesetscrew.( Pleasetightenat2.5Nm)
6-2Replacementofsilencer
Changeoneyearforanaim.
1)
Removethefrontpanelandsidepanel.
2)
Removethesilencerusinganappropriatetool,suchaspipewrench.
3)
DisassemblethesilencerasshownintheFig.andreplacethesilencermediapartwitha
newone.
4)
Reassemblethesilencerinthereverseorderofdisassembly,andthenmountthepanels.
Lock

<SM-13024-A>
15
6-3Replacementofdewpointsensor
1)
G-type(standardtype)
This product uses a temperature and humidity
sensor. It is recommended to replace this dew
pointsensoratreferenceintervalsof1year.
If the sensor is used continuously for 1 yearor longer, the accuracy
becomesworsegradually.
①
Stoptheoperationwhilereferringto
「
5-2Operationstop
」
.
②
Opentheoperationpanelandfrontpanel.
③
Disconnect the connector located at the intermediate position
between the board and sensor. Turn the sensor assembly to
removeitfromthehousing.
④
Check that the grease is applied to the O-ring of a new sensor
assemblyandreassemblethenewsensorassemblyinreverseorder
ofdisassembly.
⑤
Since the former power supply is returned when making it start
wherethesensorisremoved,pleasepushSTART.Operationpanel
display part displays "A01" with the alarm sensor simultaneously
with starting. Refer to page 9 "alarm sensor".In addition, please
removethetube(rightfigure)whichispipedfromthismachineto
the dew point sensor in that case, and attach 6mmblank plug. If
theplugisnotattached,airwillbreatheout.
2)
M-type(high-gradetype)
This product uses a highly precise dew point meter. It is
recommendedtocalibratethisdewpointmeteratreferenceintervals
of1year. Ifthedewpointmeterisusedcontinuouslyfor1yearor
longer,theaccuracybecomesworsegradually.
①
Stoptheoperationwhilereferringto
「
5-2Operationstop
」
.
②
Opentheoperationpanelandfrontpanel.
③
RemovetheDINterminalbox,whichisattachedtothedewpoint
meter.Turnthedewpointmetertoremoveitfromthehousing.
④
Please remove the tube (right figure) piped from this machine to
thedewpointmeter,andattach6mmblankpluginstead.Ifitdoes
notattach,airwillbreatheout.
⑤
Since the former power supply is returned when making it start where the sensor is
removed,pleasepush START.An operationpaneldisplaypartdisplays "A01"with the
alarmsensorsimultaneouslywithstarting.Refertopage9"alarmsensor".
⑥
Iftheproofreaddewpointmeterarrives,pleaseattachwithareversepowersupply.
Tube

<SM-13024-A>
16
Condition
Display
Causes Measures
Regeneration purge
cannotbeperformed.
Powerisnotsupplied. Turn ON the power (DEW POINT
isdisplayed).
Voltageisdifferent. Usethecorrectvoltage.
Faultywiringexists. Repair the defective part after
checking.
Fuseisblownout. Replacethefuseafterchecking.
Energy saving operation is
started.(ECOlampislit.)
Thisiscorrectoperation.
Toreturntothenormaloperation,
turnOFFtheECObutton.
Regeneration purge
occurstoofrequently.
Solenoidvalveisfaulty. Replacethesolenoidvalve.
Cylinderisfaulty. Replacethecylinder.
Foreignmatteriscaughtinthe
mainvalve.
Disassemblethevalvetocleanit.
Gasketoftheexhaustvalveis
faulty.
Replacethegasket.
Foreignmatteriscaughtinthe
checkvalve.
Disassemblethevalvetocleanit.
[RUN] lamp does not
lightup.
Lampbulbisburntup. Replacethecontroller.
[START]switchisfaulty. Replacethecontroller.
[DEW POINT] is not
displayed.
Lampbulbisburntup. Replacethecontroller.
Controllerisfaulty. Replacethecontroller.
A01
Position of the DIP-switch on
the rear of the controller is
incorrect.
Change the DIP-switch to its
properposition, and then all clear
iscarriedout.
「G-type」 「M-type」
Dewpointsensorisfaulty. Replacethedewpointsensor.
Note)Allclear:Powersupplyissuppliedpushing[STOP]buttonand[START]buttonsimultaneously.
7
.
TROUBLESHOOTING
Alloff
Display part

<SM-13024-A>
17
Condition
Display
Causes
Measures
[ALARM]lampislit.
A01
Wiringofthedewpointsensorisnot
connected.
Connectthewiringofthe dew point
sensor.
(A01putsoutthelight.)
A01
Dewpointsensorisfaulty. Replacethedewpointsensor.
(A01putsoutthelight.)
Blink Dewpointishigh. Lower the inlet air temperature and
inletairflow.
A01
Position of the DIP switch on the
rearofthecontrollerisincorrect.
ChangetheDIPswitchtoitsproper
position,andthenallcleariscarried
out.
「G-type」 「M-type」
A01
Connectorofboard(XP03,XP04)
has
notfittedin.
Itisfittedin.
(A01putsoutthelight.)
White powder particles
come out from the
silencer.
Powder particles sticking to the
desiccant, which is not in use, may
scatter.
It is correct. Powder particles are
produced when this product is
operated for the first time. This
symptom may disappear after the
product has been operated for a
while.
Watercomesoutfromthe
silencer.
Inletairtemperatureistoohigh. Lowertheinletair
temperature.
Autodrainofthefilterisbrokenand
waterdropsmayenterthedryer.
Repairtheautodrain.
Airflowistoohigh. Lower the air flow rate to its rated
level.
The dew point does not
fall.
Timeisrequiredinordertoreachthe
lowdewpoint.
The standard of time is indicated in
"5-1operation."
Dew is attached to a
desiccantvessel.
At the time of desorption, it is
because it gets cold and is not
unusual. There are especially few
amounts of secondary side
consumption, and it is the
phenomenon which is easy to set
while not putting in energy saving
equipment.
It will become difficult to set if
energysavingequipmentisputin.
Even if it puts in
energy-saving equipment,
itwillfallfromthesetting
dewpoint.
Since the desiccant is new
immediately after installation, the
dewpointwillfall.
Itisnotunusual.Ifyoucanusefora
while, it will become close to the
settingdewpoint.
Donotstart Both inlet valve shut when
pressuring it afterwards because it
haddoneSTRATwhenpressurewas
low.
Amanualvalveisopened.
Referto5-1-5)totheclause.
STRATbuttonisnotpushed. It is started pushing the STRAT
button.
All
off

<SM-13024-A>
18
8-1Specifications
Item SHD3025 SHD3045 SHD3075 SHD3100 SHD3125 SHD3150 SHD3200 SHD3240
Media Compressedair
Inletairpressurerange MPa 0.4〜1.0
Inletairtemperaturerange ℃ 5〜50
Ambienttemperature ℃ 0〜40
Ratedconditions
Inletairtemperature ℃ 35 (Nowaterdropsallowed.)
Ambienttemperature ℃ 25
Inletairpressure MPa 0.7
Inletairflow m
3
/min(ANR) 2.5 4.5 7.5 10 12.5 15 20 24
Outletpressuredewpoint ℃ −20,−40,−60
Averagepurgeratio % −20℃:14 / −40℃:16.5 / −60℃:23
Numberofdesiccantvesselmodules 1 2 3 4 5 6 8 10
Regenerationmethod Self-regenerationheatlessmethod
Desiccant Activatedalumina,syntheticzeolite
Dewpointsensor Gtype:Capacitancetypetemperatureandhumiditysensor/Mtype:Dewpointmeter
(Capacitancetypeceramicssensor)
Powersupply Single-phaseAC100/200V,50/60Hz
Powerconsumption 15W
Connectingportdiameter Rc 1 1 1
1
/
2
1
1
/
2
2 2 2
1
/
2
2
1
/
2
Mass kg 120 180 240 300 370 430 550 670
Accessoryfilter(Forinletside)STD. AF2-05M25A AF2-08M32A AF2-11M40A AF2-13M50A AF2-13M50A AF2-20M50A AF2-24M65A
Accessoryfilter(Foroutletside)STD. AF2-05P25A AF2-08P32A AF2-11P40A AF2-13M50A AF2-13P50A AF2-20P50A AF2-24P65A
Accessoryfilter(Forinletside)
Option:E2 AF4004M-25 AF4007M-40 AF4010M-40 AF4010M-40 AF4013M-50 AF4020M-50 AF5032M-80
Accessoryfilter(Foroutletside)
Option:E2 AF4004P-25 AF4007P-40 AF4010P-40 AF4010P-40 AF4013P-50 AF4020S-50 AF5032P-80
Note1: Thestandardpaintcolorisqualitycoolwhite(MunsellNo.5GY7.5/0.5).
Note2: Mountthefilterssuppliedwiththeproductontheinletandoutletsides.
Note3: ANRshowsthestatusatanatmospherictemperatureof20 andatarelativehumidity
of65%.
8
.
ATTACHEDREFERENCES
This manual suits for next models
7