© 12FEB20 Clare Controls, LLC. 1 / 6 DOC ID –1898 • Rev 02
ClareOne PIR Motion Sensor Installation Sheet
Part number: CLR-C1-PIR
Description
The ClareOne PIR Motion Sensor is designed to fit seamlessly
in the corner of the room or alongside a wall/door. When the
PIR senses motion it transmits an alarm notification to the
ClareOne panel.
Important safety instructions
Before you install this sensor, be sure to:
•Read, keep, and follow all instructions.
•Do not install near any heat sources such as
radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
•When there is a low battery, replace with a compatible
lithium ion battery.
Installation
Note: We recommend adding the motion sensor to the
ClareOne panel before installation. For adding a sensor, see
ClareOne User Guide (DOC ID 1871).
The motion sensor can be installed using the provided
adhesive or screws.
Note: We recommend using the provided screws for
installation. This method is more secure than using adhesive
alone.
To install the motion sensor:
1. Select the desired position for the sensor.
Note: The sensor only detects motion within 3.28 ft. (1 m)
below it and installed at 6.88 ft. (2.1 m) having a range of
32.80 ft. (10 m).
2. Remove the sensor’s battery pull tab.
3. Add the sensor to the panel. See “Sensor Management,”
ClareOne User Guide (DOC ID 1871).
Note: You must press the button on the side of the sensor
to pair the sensor to the panel.
4. Adhere the sensor to the wall using the provided screws or
adhesive.
Note: We recommend using the provided screws for
installation. This method is more secure than using
adhesive alone.
Screws
4.1.a Locate the bottom of the sensor (the slotted
flat end), and then use a screwdriver to remove
the casing’s screw.

© 12FEB20 Clare Controls, LLC. 2 / 6 DOC ID –1898 • Rev 02
4.1.b Gently slide a fingernail/fingertip into the slot
and push the top casing of the sensor upward.
4.1.c (Optional) Mark the screw hole locations,
then using a power drill, drill holes and install the
2 provided wall anchors.
4.1.d Remove the adhesive film cover, and then
place the back plate against the wall, making
sure that the orientation is correct for the desired
position.
Note: Once placed the sensor cannot be moved
without damaging the adhesive.
4.1.e Insert the included mounting screw into the
screw breakaway screw hole, using a screwdriver
to fully secure the backplate to the wall.
4.1.fBefore finishing installation, set the PINs and
jumpers to the desired position. See, Pin function
on page 4.
4.1.g Once the sensor is configured as desired,
press the sensor cover against the base, until
there is an audible snap.
4.1.h Use the sensor’s casing screw to secure the
cover.
Adhesive
4.2.a Locate the bottom of the sensor (the slotted
flat end), and then use a screwdriver to remove
the casing’s screw.
4.2.b Gently slide a fingernail/fingertip into the slot
and push the top casing of the sensor upward.
4.2.c Set the PINs and jumpers to the desired
position. See, Pin function on page 4.
4.2.d Once the sensor is configured as desired,
press the sensor cover against the base, until
there is an audible snap.
4.2.e Use the sensor’s casing screw to secure the
cover.

© 12FEB20 Clare Controls, LLC. 3 / 6 DOC ID –1898 • Rev 02
4.2.fPeel the film cover off of the adhesive, and then
firmly press the sensor back plate against the
wall.
Note: Once placed, the sensor cannot be moved
without damaging the adhesive.
5. Once added, test the sensor.
Look at the ClareOne panel, and then open the
door/window.
Notice that the added sensor displays faulted.
Note: Testing all sensors with the alarm monitoring
station is strongly advised.
Figure 1: Sensor range and detection
Battery replacement
The CLR-C1-PIR requires a CR123A battery. Once the battery
is low, the panel displays a low battery icon next to the sensor
in the devices list. The battery must be replaced within 7 days
of the first low battery notification. If the battery is not replaced
within 7 days, the sensor may not function properly.
WARNING: If an incompatible replacement battery is used, or
the battery is installed incorrectly explosion or damages may
occur.
AVERTISSEMENT: Si une batterie de remplacement
incompatible est utilisée ou si la batterie est installée de
manière incorrecte, une explosion ou des dommages peuvent
survenir.
To replace the battery:
Note: Verify that the panel is not armed before changing the
battery.
1. Locate the bottom of the sensor (the slotted flat end), and
then use a screwdriver to remove the casing’s screw.
2. Gently slide a fingernail/fingertip into the slot and push the
top casing of the sensor outward, away from the wall.
3. Use a fingernail/fingertip to push the battery out of the
casing, noting the polarity of the battery.

© 12FEB20 Clare Controls, LLC. 4 / 6 DOC ID –1898 • Rev 02
4. Insert a new CR123A battery into the battery casing,
making sure that the polarity is correct.
5. Press the sensor cover back onto its back plate. There will
be an audible snap.
6. Use the sensor’s casing screw to secure the cover
7. Test the sensor.
Pin function
The PIR Motion Sensor has 2 sets of adjustable pins. The pins
adjust the Pet Immunity setting and the Sensitivity level. Each
set of pins has 2 settings that can be selected.
Figure 2: Sensor pins and tamper switch
(1) Pet immunity pins
(2) Tamper switch
(3) Sensitivity pins
(4) Battery
Table 1: Pin configuration
Configuration
Pet Immunity
Sensitivity
Top and middle pin
Up to 33lb dog
Low –max of
19 ft. (6 m)
distance range
Middle and bottom pin
Up to 55lb dog
High –max of
32 ft. (10 m)
distance range
Pet Immunity
The pet immunity pins allow the user to select the desired
immunity level. Place the selector over the desired pin
configuration.
To change the pet immunity level:
1. Remove the back plate from the motion sensor.
2. Turn the sensor over so the battery faces up.
3. Locate the pet immunity pins on the left side.
4. Gently pinch the jumper and pull upward and away from
the sensor.
All 3 pins are visible.

© 12FEB20 Clare Controls, LLC. 5 / 6 DOC ID –1898 • Rev 02
5. Gently press the jumper on the desired pin set.
See Table 1: Pin configuration, on page 4.
6. Replace the sensor plate, and then continue to installation.
–or –
Adjust the sensitivity level, and then continue to
installation.
Sensitivity
The sensitivity pins allow the user to select the desired
sensitivity level. Place the selector over the desired pin
configuration.
To change the sensitivity level:
1. Remove the back plate from the motion sensor.
2. Turn the sensor over so the battery faces up.
3. Locate the sensitivity pins on the right side.
4. Gently pinch the jumper and pull upward and away from
the sensor.
All 3 pins are visible.
5. Gently press the jumper on the desired pin set.
6. Replace the sensor plate, and then continue to installation.
–or –
Adjust the pet immunity level, and then continue to
installation.
Specifications
Compatible panel
ClareOne
Transmitter frequency
433MHZ TX
Encrypted
Yes
Pet immunity
33 to 55lb dog
Detection length
Default: 32.80 ft. (10 m)
Optional: 19.68 ft. (6 m)
Detection angle
90 degrees
Mounting height
7.5 to 9.5 ft. (2.28 to 2.89 m)
Transmitted indications
Tamper
Low battery
Screw size
M3 × 16 mm
Adhesive
3M 4930
Pin function
Sensitivity (6 m to 10 m)
Pet immunity (33 to 55lb dog)
Button
Pairing
Battery type
CR123A (1300mAh)
Battery life
5 years
Sensor dimensions
(W × H × D)
2.16 × 2.99 × 1.65 in.
(55 × 76 × 42 mm)
Operating environment
Temperature
Relative humidity
32 to 122°F (00 to 50°C)
85% max
Water resistance
None

© 12FEB20 Clare Controls, LLC. 6 / 6 DOC ID –1898 • Rev 02
Regulatory information
Manufacturer
Clare Controls, Llc.
7519 Pennsylvania Ave, Suite 104
Sarasota, FL 34243
North American
standards
ETL listed to: UL 639, ULC S306
FCC compliance
FCC ID: 2AVDC-XPM-201
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found
to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation. This equipment generates,
uses and can radiate radio frequency energy and,
if not installed and used in accordance with the
instructions, may cause harmful interference to
radio communications. However, there is no
guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference
to radio or television reception, which can be
determined by turning the equipment off and on,
the user is encouraged to try to correct the
interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the
equipment and receiver.
-- Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV
technician for help.
Warning: changes or modifications not expressly
approved by the party responsible for compliance
could void the user’s authority to operate the
equipment.
This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled
environment. This equipment should be installed
and operated with minimum distance 20 cm
between the radiator and your body.
Environmental
class
UL: Indoor dry
IEC: 3K5
EU compliance
EN 54
EN 54-00:0000
European Union
directives
1999/5/EC (R&TTE directive): Hereby, Clare
Controls declares that this device is in
compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.
2004/108/EC (EMC directive): Hereby, Clare
Controls, Llc. Declares that this device is in
compliance with the essential requirements and
other relevant provisions of Directive
2004/108/EC.
2002/96/EC (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info.
2006/66/EC (battery directive): This product
contains a battery that cannot be disposed of as
unsorted municipal waste in the European Union.
See the product documentation for specific
battery information. The battery is marked with
this symbol, which may include lettering to
indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the battery to
your supplier or to a designated collection point.
For more information see: www.recyclethis.info.
Warranty information
Clare Controls offers a three (3)
year limited warranty on original
Clare Controls components, from
the date of shipment from Clare
Controls. To view complete
limited warranty details, including
limitations and exclusions,
www.clarecontrols.com/warranty.
Scan the
code
to view
product
warranty
details.
Contact information
Clare Controls, LLC.
7519 Pennsylvania Ave, Suite 104
Sarasota, FL 34243
General: 941.328.3991
Fax: 941.870.9646
www.clarecontrols.com
Integrator/Dealer Support: 941.404.1072
Homeowners should contact their installation dealer for
assistance.
Scan the code to
view the full PDF
online.
Table of contents
Other Clare Controls Security Sensor manuals
Popular Security Sensor manuals by other brands

Heath Consultants
Heath Consultants RMLD-CS quick start guide

i4Technology
i4Technology BugHunter Professional BH-03 Expert Operation manual

EMX Industries, Inc.
EMX Industries, Inc. CarSense 303 operating instructions

STEINEL
STEINEL professional HPD2 KNX quick start guide

HOKUYO AUTOMATIC
HOKUYO AUTOMATIC PBS-03JN-V01 instruction manual

Basalte
Basalte AURO KNX Series installation manual