CLINTON INDUSTRIES 80100 User manual

USER MANUAL
OPEN BASE POWER TABLES
SHROUDED POWER TABLES
OPEN BASE IMAGING TABLES
CLI-MA-004 REV C
Limited Warranty
ON FRAME &
ELECTRICAL
COMPONENTS
Limited
Warranty

Thank you, for selecting and purchasing Clinton equipment. We are proud to serve your
medical equipment needs with products that deliver value and offer superior performance. Please
read these instructions carefully to insure your Clinton products are used and operated according
to specifications and that they are maintained to Clinton’s recommendations.
This manual provides the description of the functions of Clinton Open Base Power Tables,
Shrouded Power Tables and Open Base Imaging Tables.
LEGAL NOTICES
All the features, functionality, and other product specifications are subject to change without prior
notice or obligation. Information contained herein is subject to change without notice.
Clinton logo is a trademarks of Clinton Industries, Inc. All other brands and product names
referred to are trademarks of their respective holders. The ® or ™ symbols are not used in the text.
DISCLAIMER
Information in this document is provided in connection with Clinton products. No license, express
or implied to any intellectual property rights is granted by this document. Clinton assumes no
liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of
Clinton products including liability or warranties relating to fitness for a particular purpose other
than its intended use, or infringement of any patent, copyright or other intellectual property right.
In no event shall Clinton Industries’ liability exceed the price paid for the product from direct,
indirect, special, incidental, or consequential damages resulting from the use of the product, or
its documentation or errors in its documentation. Clinton Industries, Inc. makes no warranty or
representation, expressed, implied, or statutory, with respect to the use of this documentation.
Clinton Industries, Inc. reserves the right to revise or update its products, or documentation with-
out obligation to notify any individual or entity
1
LEGAL

2
CONTENTS
Intended use............................................................................................................................................... 3
Symbols, Classification, Rating & Mode of Operation ................................................................................. 4
Important Safety Guidelines........................................................................................................................ 5
Product Description ............................................................................................................................6—18
Unpacking & Setup .................................................................................................................................. 19
Cleaning................................................................................................................................................... 20
Installation................................................................................................................................................ 21
Operation.......................................................................................................................................... 22—25
Periodic Visual Inspections ........................................................................................................................ 26
Warranty................................................................................................................................................... 27
Model & Serial Number............................................................................................................................ 28
Specifications/Products......................................................................................................................29—33
EMC Compliance & Manufacturer’s Declarations ............................................................................... 34—37
Notes ....................................................................................................................................................... 38
Contact Information .................................................................................................................... Back Cover

INTENDED USE
All models of Clinton Power Treatment Tables are only intended for operation by health care
professionals in a medical environment for general physical examinations. No special training
is required; however, the health care professional should read and understand this entire User’s
Manual.
Review of the Safety Instructions and cautionary statements is imperative to the safety of both
the patient and operator. Operators may be either sitting or standing, but must always be within
close proximity to the patient and have a full view of both the table and the patient. The patient
should never be left unattended on the table. The Power Treatment Tables should always be
placed on a dry, level surface to insure safe operation and positioned so that the power cord
connection to the wall outlet is easily accessible and never blocked in any manner.
The Power Treatment Tables have two basic functions, raising and lowering of patients. They
operate within a height range of 18 to 34 inches off the floor, allowing ease of patient access and
examination. Clinton Power Treatment Tables are intended to be sat or laid upon during
examinations of less than 30 minutes within the medical facility and may be used as frequently as
necessary to accommodate the facility’s patient schedule.
The Power Treatment Tables are NOT intended for patient transportation. Some tables are
equipped with locking castors to allow for positioning the table within the facility and for ease of
cleaning the examination room or area.
The intended population is for any demographic patient that is alert and able to support
themselves with the exception of infants and individuals with a weight that exceeds 500 lbs.
(227 kg), or 600 lbs. (272 kg) for bariatric models.
SERVICE
If your Clinton Power Tables should fail operating for any reason, please call Clinton Industries for
assistance in diagnosing the problem and having your equipment serviced, if necessary.
Clinton Power Treatment Tables have no field serviceable parts. If failure occurs, unplug the table
from the wall outlet and contact Clinton Industries, or your local Clinton distribution office.
Please provide the following information before calling Clinton regarding an in or out of warranty
problem.
3
INTENDED USE
Date of Purchase:
Serial Number:
Model Number:
Dealer/Distributor:
Dealer/Distributor Phone:
Dealer/Distributor Address:
Model Number and
Serial Number are
located on the leg
at the foot end of
the table.
(See page 28)

4
SYMBOLS, CLASSIFICATION, RATING & MODE OF OPERATION
Pay particular attention to Cautions and Warnings throughout this manual.
Potentially hazardous and harmful situations to users, patients and property can
occur if these cautions and warnings are ignored.
Operating Instructions
Alternating and Direct Current
Dangerous Voltage
Sitting Prohibited
Pinch Point: Can cause serious injury. Keep hands and fingers clear.
Refer to Manual/Booklet
Earth (Ground)
For safety purposes, please familiarize yourself with the following symbols and their meanings which appear
through this manual.
APPLIED PARTS Classification: Type B
• Never use these tables in an oxygen rich
environment. Failure to do so could result in a
flash fire or explosion which could result in
serious injury or death.
• Mode of Operation: Non-continuous
(2 min. on/18 min. off)
CLASSIFICATION, RATING & MODE OF OPERATION
SYMBOLS
• Class II ME Equipment
• APPLIED PARTS Classification: Type B
Applied Parts: (Upholstered Top, Stirrups,
Foot Pedal, Foot Rest)
• “IP” rating: IPX4

WEIGHT LIMIT
Clinton Power Tables are specifically designed to be used by medical and physical therapy
professionals for patient treatment and examinations where the load capacity or combined load and
force does not exceed 500 pounds (227 kg) on all standard models and 600 pounds (272 kg) on
bariatric models.
WARNING
To reduce the risk of injury due to electrical shock, burns or fire follow the following procedures:
• Unplug the table before cleaning
• Unplug the table before adding accessories or removing and replacing parts
• Do not use the table if it has been damaged in any way, especially the electrical connection
• Unplug the table and do not use if the table has been in or damaged by water or excessive moisture
• Keep cord away from heat or surfaces that may become hot
• Do not modify this equipment without authorization from Clinton Industries
• Mains plug is used as primary means of disconnect. Do not position the equipment such that it is
difficult to operate the disconnection device.
• Not intended for outdoor use
• Never operated where aerosol sprays, oxygen or other potentially flammable products are being used
Power Treatment Tables are designed to comply with IEC 60601-1-2. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with instructions,
may cause harmful interference to other devices in the vicinity. However, there is no guarantee that
interference will not occur in a particular installation. Harmful interference to other devices can be de-
termined by turning this equipment on and off. Try to correct the interference using one or more of the
following:
• Reorient or relocate the receiving device
• Increase the separation between the equipment
• Connect the equipment to an outlet on a different circuit from that to which the other device(s) are
connected and consult the factory field service technician for help
• Consult Clinton Industries for help
• Care must be taken when operating this equipment around other equipment to avoid reciprocal
interference. Potential electromagnetic or other interference could occur to this or to the other
equipment. Try to minimize this interference by not using other equipment in conjunction with this
device.
DANGER
Risk of Electrical Shock.
Always connect these tables to a properly grounded 120V outlet.
The power supply and controller contains no serviceable parts. If failure occurs, unplug the table from
the wall outlet and contact Clinton Industries, or your local Clinton distribution office.
5
IMPORTANT SAFETY GUIDELINES

SPECIFICATIONS
Length 72"
Width 27"
Height Range 18" – 35"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 72"
Width 27"
Height Range 18" – 35"
Backrest 38" x 27"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
A
A
B
C
E
D
F
6
PRODUCT DESCRIPTION: Open Base Power Tables
A
A
B
C
D
E
F
For electrical specifications refer to the specifications section of this manual
80200
80100
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

SPECIFICATIONS
Length 76"
Width 27"
Height Range 18" – 35"
Drop Section 13" x 27"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 76"
Width 27"
Height Range 18" – 35"
Backrest 38" x 27"
Drop Section 13" x 27"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. Upholstered Drop Section
A
A
B
CG
D
E
F
A
A
B
C
G
D
E
F
80330
80220
For electrical specifications refer to the specifications section of this manual
PRODUCT DESCRIPTION: Open Base Power Tables
7
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. Upholstered Drop Section
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

SPECIFICATIONS
Length 76"
Width 27"
Height Range 18" – 35"
Leg Rest 13" x 26"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 76"
Width 27"
Height Range 18" – 35"
Backrest 38" x 27"
Leg Rest 13" x 19"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. Upholstered Leg Rest
H. Stirrups
A
A
BC
G
D
E
F
A
A
B
C
GD
E
F
80360
80350
8
PRODUCT DESCRIPTION: Open Base Power Tables
For electrical specifications refer to the specifications section of this manual
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. ClintonClean Leg Rest
H
H
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

SPECIFICATIONS
Length 72"
Width 34"
Height Range 18" – 35"
Drop Section 13" x 27"
Load/Force Capacity 600 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 72"
Width 34"
Height Range 18" – 35"
Backrest 38" x 34"
Drop Section 13" x 27"
Load/Force Capacity 600 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
A
A
B
CG
D
E
F
A
A
B
C
G
D
E
F
84200-34
84100-34
84100-40
84200-40
For electrical specifications refer to the specifications section of this manual
PRODUCT DESCRIPTION: Open Base Power Tables
9
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
SAME AS 84430-34 WITH A 40" OVERALL WIDTH
SAME AS 84430-34 WITH A 40" OVERALL WIDTH & 40" BACKREST WIDTH
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

SPECIFICATIONS
Length 76"
Width 34"
Height Range 18" – 35"
Backrest 38" x 34"
Drop Section 13" x 34"
Load/Force Capacity 600 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
A
A
B
C
G
D
E
F
84430-34
84430-40
10
PRODUCT DESCRIPTION: Open Base Power Tables
For electrical specifications refer to the specifications section of this manual
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. Upholstered Drop Section
SAME AS 84430-34 WITH A 40" OVERALL WIDTH & 40" BACKREST WIDTH
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

SPECIFICATIONS
Length 72"
Width 27"
Height Range 21" – 34"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 72"
Width 27"
Height Range 21" – 34"
Backrest 38" x 27"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
A
A
B
C
D
A
A
B
C
D
For electrical specifications refer to the specifications section of this manual
81200
81100
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
11
PRODUCT DESCRIPTION: Shrouded Power Tables
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

12
SPECIFICATIONS
Length 76"
Width 27"
Height Range 21" – 34"
Drop Section 13" x 27"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 76"
Width 27"
Height Range 21" – 34"
Backrest 38" x 27"
Drop Section 13" x 27"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
E. Upholstered Drop Section
A
A
B
C
E
D
A
A
BE
C
D
81330
81220
For electrical specifications refer to the specifications section of this manual
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
E. Upholstered Drop Section
PRODUCT DESCRIPTION: Shrouded Power Tables
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

13
SPECIFICATIONS
Length 76"
Width 27"
Height Range 21" – 34"
Leg Rest 13" x 26"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 76"
Width 27"
Height Range 21" – 34"
Backrest 38" x 27"
Leg Rest 13" x 19"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
G. Upholstered Leg Rest
H. Stirrups
A
A
B
C
E
D
A
A
B
E
C
D
81360
81350
For electrical specifications refer to the specifications section of this manual
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
E. ClintonClean Leg Rest
PRODUCT DESCRIPTION: Shrouded Power Tables
HH
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

14
SPECIFICATIONS
Length 72"
Width 34"
Height Range 21" – 34"
Drop Section 13" x 27"
Load/Force Capacity 600 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 72"
Width 34"
Height Range 21" – 34"
Backrest 38" x 34"
Drop Section 13" x 27"
Load/Force Capacity 600 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
A
A
B
G
C
D
A
A
B
C
D
84208-34
84108-34
84108-40
84208-40
For electrical specifications refer to the specifications section of this manual
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
SAME AS 84430-34 WITH A 40" OVERALL WIDTH
SAME AS 84430-34 WITH A 40" OVERALL WIDTH & 40" BACKREST WIDTH
PRODUCT DESCRIPTION: Shrouded Power Tables
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

SPECIFICATIONS
Length 76"
Width 34"
Height Range 21" – 34"
Backrest 38" x 34"
Drop Section 13" x 34"
Load/Force Capacity 600 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
A
A
B
C
E
D
84438-34
84438-40
15
For electrical specifications refer to the specifications section of this manual
PARTS
A. Frame
B. ABS Shroud
C. Upholstered Top
D. Foot Controller
E. Upholstered Drop Section
SAME AS 84430-34 WITH A 40" OVERALL WIDTH & 40" BACKREST WIDTH
PRODUCT DESCRIPTION: Shrouded Power Tables
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

SPECIFICATIONS
Length 72"
Width 27"
Height Range 18" – 35"
Drop Window 10" x 10"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
SPECIFICATIONS
Length 72"
Width 27"
Height Range 18" – 35"
Backrest 38" x 27"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
A
AB
C
D
E
F
16
PRODUCT DESCRIPTION: Open Base Power Imaging Tables
A
AB
C
G
E
F
For electrical specifications refer to the specifications section of this manual
85200
85100
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. Drop Window
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. Drop Window
D
G
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

17
SPECIFICATIONS
Length 76"
Width 27"
Height Range 18" – 35"
Backrest 38" x 27"
Drop Section 13" x 27"
Drop Window 10" x 10"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings
A
A
F
B
C
EG
HD
F
85300
For electrical specifications refer to the specifications section of this manual
PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. Drop Window
H. Drop Section
PRODUCT DESCRIPTION: Open Base Power Imaging Tables
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

SPECIFICATIONS
Length 76"
Width 27"
Height Range 21" – 34"
Backrest 38" x 27"
Drop Section 13" x 19"
Drop Window 10" x 10"
Load/Force Capacity 500 lbs.
Upholstery knit-backed vinyl
Warranty 5-year limited
Voltage 120V
Safety Listings PARTS
A. Frame
B. Control Box
C. Actuator
D. Scissors Lift
E. Upholstered Top
F. Foot Controller
G. Drop Window
H. Drop Section
I. Stirrups
A
A
B
E
H
I
I
G
C
D
85309
For electrical specifications refer to the specifications section of this manual
PRODUCT DESCRIPTION: Open Base Power Imaging Table
18
OPTIONS
030 Paper Dispenser
040 Paper Cutter
034 Paper Dispenser/Cutter Combo
080 Safety Straps
083 Safety Rails
084 Hand Held Controller

6. Leveling
For optimum performance an patient safety, all Clinton Power Treatment Tables should be on a clean,
level non-slip surface.
Once the table is in the desired location, level the table by adjusting the four leveling feet on the
table. Turn the feet counter clockwise to decrease the height and clockwise to increase the height of
the leg.
Make certain that the table is level in all directions and that it does not wobble or rock.
46
UNPACKING THE POWER TABLE
1. Remove any strapping and cardboard lid
2. Remove wooden post supports from each
corner.
3. With help, lift main cardboard surround
off the table.
4. Pull corners of cardboard tray apart so
tray is flat.
5. With the assistance of one or more persons,
lift power table off skid and into position.
3
2
1
All Clinton Power Treatment Tables ship fully assembled. However, care should be taken when
unpacking the table so as not to damage the equipment.
BEFORE STARTING TO UNPACK THE EQUIPMENT inspect the boxes for damage that may have
occurred during the shipping process. Clinton uses every packaging option available to insure that
equipment arrives at its destination in factory condition, however, Clinton Industries has no control
over third party handling once it leaves our facilities. Report any visible damage to Clinton and the
shipping carrier immediately.
After the package is inspected for visible damage, follow the unpacking steps below.
CAUTION: Do not use a knife or other sharp object that may puncture or damage the
upholstery during the unpacking process.
CAUTION: Clinton Power Treatment Tables are heavy. Clinton Industries recommends
four reasonably strong individuals using proper lifting techniques be used to lift or move
the table. Not using the recommended number of movers may result in injury to the
persons attempting to lift or move the equipment.
CAUTION: Always lift the table by the metal frame. If table is equipped with stirrups,
never used the extended stirrups for lifting the table. This could result in damage to the
stirrups or table, and may result in injury to the individuals attempting to move or lift the table.
UNPACKING & SETUP
19
This manual suits for next models
27
Table of contents
Other CLINTON INDUSTRIES Medical Equipment manuals