manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CLS
  6. •
  7. Floodlight
  8. •
  9. CLS CAS 6 Luxeon K2-TFFC User manual

CLS CAS 6 Luxeon K2-TFFC User manual

CLS Manuals
CLS Atmosphere LED-panel
CLS Manuals
CLS CAS 6 Luxeon K2-TFFC
www.cls-led.com
Version 2.0 November 2010
www.cls-led.com
- 1 - - 2 -
CLS CAS 6 Luxeon K2-TFFC
INTRODUCTION
Thank you for choosing the CLS CAS 6 inground floodlight. The CLS CAS 6 floodlight is a compact but yet
powerful inground floodlight for numerous applications. The unit can be used for lighting up all sorts of
facades, objects and landscape lighting projects.
Included items
The CLS CAS 6 is shipped in one package containing the following items:
• 1 x CLS CAS 6 inground floodlight
• 1 x CAS 6 Sleeve
• 1 x manual
Optional accessories
• 871992 CLS mold set, straight 8-26mm
• 87215773 CLS CAS 6 Spot Lens plate
• 872157 CLS CAS 9 frosted glass
Note: It is important to read this manual before you install this product.
SAFETY INFORMATION
Warning! This product is for professional use only, not for domestic use.
Read this manual before powering up or installing the CLS CAS 6. Follow the instructions listed
below and observe all warnings in this manual.
Protection from electric shock
• Disconnect the power supply from AC power before installing, dismounting or maintaining the unit.
• Make sure all connectors are connected properly.
• Use only a source of AC power that complies with local building and electrical codes and has both
overload and ground-fault protection.
• Refer all service to a qualified technician.
Available CLS CAS 6 floodlights
• 87215765 CLS CAS6 flood 6xK2-TFFC warm white 3150K 110-277V IP65
• 87215768 CLS CAS6 flood 6xK2-TFFC cold white 6700K 110-277V IP65 (not in stock)
2007 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated
companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other
loss occasioned by the use of, inability to use or reliance on the information contained in this manual. No part
of this manual may be reproduced, in any form or by any means, without permission in writing from CLS-LED
BV. Other legal information can be found in our General conditions to be found on the back of your CLS-LED BV
invoice or on our website www.cls-led.com/conditions.pdf
CLS Manuals
CLS Atmosphere LED-panel
www.cls-led.com
- 3 - - 4 -
CLS CAS 6 Luxeon K2-TFFC
INSTALLATION
This section shows how to install the CLS CAS 6.
ATTENTION!
TO prEvENT dAmAgE TO ThE CLS CAS 6, uSE ThE INCLudEd
CLS CAS 6 SLEEvE. mAkE SurE drAINAgE CONdITIONS ArE
AdEquATE. ThESE prECAuTIONS muST bE fOLLOwEd,
OThErwISE ThE wArrANTy wILL bECOmE INvALId!
WARNING
Drainage
To minimize the risk of flooding or water logging, install the fixture in a location which is above the level of
the surrounding area, and make sure drainage conditions are adequate. CLS recommends to use gravel for
the best drainage conditions. The unit is not designed to withstand high pressure water jets.
Protection from burns and fire
• Do not install the CLS CAS 6 near a heat source.
• Do not install the CLS CAS 6 in a corrosive, flammable or explosive area.
• Do not modify the CLS CAS 6, or install other than genuine parts.
• Do not operate the CLS CAS 6 if the ambient temperature exceeds 40 ºC.
• Do not stare into the LED, this can cause damage to the eyes.
Protection from injury due to falls
• Verify that all covers and mounting hardware are securely fastened.
• Block the access below the work area whenever installing or removing the unit.
CABLE INSTALLATION
Cable slack
Allow at least 300 mm of free cable in the installation, so that the CLS CAS 6 is clear for service without
disconnecting cables.
NOTE!
For protection from potentially lethal electric shock:
• The CLS CAS 6 must be grounded.
• The AC-power supply must be fitted with a fuse or circuit breaker, ground-fault protection, and a means
to isolate the CLS CAS 6 from power during service or when not in use.
• Cables and fixtures must be isolated from power, and steps taken to prevent reconnection, before carrying
out any work on them.
• Do not connect the CLS CAS 6 to an electrical dimmer system: doing so can damage the electronics.
Connecting to AC-power
Connect the power cable only on the right positions! See diagram for the colours of all electric cables:
Wire (EU) Function Marking
Brown Live L
Blue Neutral N
Yellow/green Earth
Obstruction by roots
The further the CLS CAS 6 is located from vegetation such as trees, hedges or bushes, the less chance there
is that the roots will obstruct the CLS CAS 6 or even cause damage to its cables. If the CLS CAS 6 is located
close to vegetation, consult a landscape architect about the solutions for the root obstruction.
CLS Manuals
CLS Atmosphere LED-panel
www.cls-led.com
- 5 - - 6 -
CLS CAS 6 Luxeon K2-TFFC
The CLS CAS 6 with Flood lenses. Disassemble the stainless steel
ring by loosening the 5 screws.
Semi-tighten the screws by order
(crosswise) as shown in picture 6
on the stainless steel ring. To keep
the CAS 6 IP65 (waterproof).
Repeat the previous steps to
tighten the screws and the CLS
CAS 6 is ready to be used with
the spot lenses.
Carefully lift the lens plate out of
the CAS 6 unit.
Now carefully place the Spot Lens
plate in the CAS 6. Make sure the
lenses are placed on the LEDs.
LENS PLATE INSTRUCTION
Install example
Disassemble the stainless steel ring from
the CLS CAS 6 by loosening the 5 screws.
Assemble the stainless steel ring back on
the CAS 6 unit. The CAS 6 is ready to be
installed.
To install the CAS 6 into the sleeve, tread
the wire trough one of the holes on the
side. Slide the CAS 6 unit inside and
secure it in the screw holes.
Install the CAS 6 into the ground. Finish
the surface around the CLS CAS 6 with
gravel. Ensure that the foundation will
withstand pressure on the CLS CAS 6.
CLS Manuals
CLS Atmosphere LED-panel
www.cls-led.com
- 7 - - 8 -
CLS CAS 6 Luxeon K2-TFFC
25 mm
ø 28,5 mm
ø 151mm
164,5 mm
146,5 mm
18 mm
ø 110 mm
ø 210 mm
MEASUREMENTS
CAS 6
CAS 6 sleeve
TECHNICAL SPECIFICATIONS
LED: Luxeon K2-TFFC
Available colours: Cold white 6700K, warm white, 3150K
Lenses: Flood (45°) & spot (15º)
Power supply: 110 ~ 277 VAC
Power consumption: Max. 18 VA
Housing: Aluminum ADC-12 & stainless steel (316)
Weight: 3 kg
IP value: IP65
Cable length: 3 meters
Measurements: ø Top: 202 mm - ø inground: 148 mm
Ambient temperature: -20 ºC till +40 ºC
Max. pressure: 15 kg/cm2
Multiple connection
Possiblities on a fixture
Installation depth
In centimeters
Swivel
Fixture is horizontally rotatable,
indicated in degrees
Swivel
Fixture is vertically rotatable,
indicated in degrees
Mounting hole
In centimeters
Application area
Indoor or outdoor
Application area
Floor, wall or ceiling
Protection class
One, two or three
Cable length
Maximum cable attached
on the fixture in centimeters
Lifespan
Of the light source in hours
Driver
Inclusive or exclusive
Pressure
Maximum pressure on
the fixture per kg/cm2
Weight
In gram/kilogram
Curve
Minimal bending curve
in centimeters
LED pitch
Pitch between the
LEDs in millimeters
Cutting length
Indicated by the
cutting marks
DMX channels
DMX channels on
a product

This manual suits for next models

2

Other CLS Floodlight manuals

CLS Revo Basic User manual

CLS

CLS Revo Basic User manual

CLS Facade 12 RGB User manual

CLS

CLS Facade 12 RGB User manual

CLS REVO XXL DUO DMX Series User manual

CLS

CLS REVO XXL DUO DMX Series User manual

Popular Floodlight manuals by other brands

KODA LM030022 Care & use instructions

KODA

KODA LM030022 Care & use instructions

ACR Electronics RCL-100D Product support manual

ACR Electronics

ACR Electronics RCL-100D Product support manual

HAMPTON BAY HD33680 Use and care guide

HAMPTON BAY

HAMPTON BAY HD33680 Use and care guide

Heath Zenith SECUR360 9309 manual

Heath Zenith

Heath Zenith SECUR360 9309 manual

Show Tec Double3 Derby LED Q6 manual

Show Tec

Show Tec Double3 Derby LED Q6 manual

ICON STAGE user manual

ICON

ICON STAGE user manual

Show Tec Ignitor-6 Section Strobe manual

Show Tec

Show Tec Ignitor-6 Section Strobe manual

Solar Goes Green SGG-FL9W-Extreme user manual

Solar Goes Green

Solar Goes Green SGG-FL9W-Extreme user manual

afx light COMBO-LED 15-1872 instruction manual

afx light

afx light COMBO-LED 15-1872 instruction manual

Timeguard LEDX20PIRBN Installation & operating instructions

Timeguard

Timeguard LEDX20PIRBN Installation & operating instructions

Show Tec Expression 5000 Product guide

Show Tec

Show Tec Expression 5000 Product guide

Show Tec LED Light Bar RGB user guide

Show Tec

Show Tec LED Light Bar RGB user guide

Chauvet Line Dancer CH-300 user guide

Chauvet

Chauvet Line Dancer CH-300 user guide

Show Tec Infinity iS-100 manual

Show Tec

Show Tec Infinity iS-100 manual

Heath Zenith Secure Home 7103 user manual

Heath Zenith

Heath Zenith Secure Home 7103 user manual

Ignition 477575 user manual

Ignition

Ignition 477575 user manual

XanLite PR10WMD manual

XanLite

XanLite PR10WMD manual

Erco Kona Mounting instructions

Erco

Erco Kona Mounting instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.