CMA Dishmachines VINCILAB User manual

!
!
!
VinciLab!is!an!advanced!mobile!graphic!data!acquisition!system,!which!can!be!used!in!a!variety!
of!ways,!standalone!and!with!a!computer!or!tablet,!in!the!classroom!and!in!the!field.!!
!
!! !!!!
!
!!!!!!!!!!! !!!!!!!!!!!!
!
!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !
!
!
!
!
!
!
The! Home! Screen! is! the! starting! point! for! using! VinciLab! and! provides! shortcuts! to!
applications.! Tap!an! application’s! icon!to! launch! the!application.!Tap! !Home!to! display!the!
Home!Screen.!Tap !Back!to!return!to!the!previous!screen.!!
!
!
Coach+!!
Collecting,!graphing!and!processing!data!
!
Web+Browser!!
Accessing!the!Internet!
!
My+Files!!
Managing!user!files!on!VinciLab!
!
Images!!
Browsing!and!displaying!images!
!
Settings!!
Configuring!the!device!to!your!preferences!
!
Media+Player!!
Playing!audio!and!video!files!
!
Connections!!
Configuring!the!wireless!connections!
!
Calculator!!
Performing!simple!mathematical!calculations!
!
!
Internal++
Sound+Sensor+
for!recording!
sound!signals!
!
Home+Screen+
for!controlling!VinciLab!!
and!providing!shortcuts!
to!Applications.+
!
Power+Button+for!turning!VinciLab!On!or!Off!!
and!for!turning!the!screen!on!when!it!is!timeout!!
Analog+(A1,!A2,!A3,!A4)+and+Digital+(D1,!D2)+Inputs+
for!connecting!sensors!
!
Mini+USB+Port+for!charging!and!communication!
USB+Port+for!connecting!any!USB!peripheral+
+
Audio+Out+(left)+for!generating!DC/AC!voltage!signals!
Audio+In!(right)!for!connecting!external!microphone+
!
At!the!backside!of!VinciLab!a!Speaker!and!a!compartment!with!an!internal!rechargeable!Battery!are!located.!
!
TO!TURN!VINCILAB!OFF:!
!
•
Tap! !or!press!shortly!the!hardware!Power!button.!!!
•Tap! !to!shut!down,! !to!reboot,! !to!turn!the!screen!off,!or! !to!cancel.!!
A1!
!
A2!
!
A3!
!
A4!
!
D1!
!
D2!
!
Capacitive+Color++
Touch+Screen!
for!viewing!!
and!controlling!!
!
QUICK!START!GUIDE
+
!
VINCILAB!
!
+

!
Ω!
!
COACH+APPLICATION+
Is!a!powerful!software!installed!on!VinciLab,!which!offers!live!sensor!data!displays,!real-time!
graphing,!tools!for!data!processing!and!possibilities!to!create!new!or!open!ready-to-go!
student!activities!enriched!with!texts,!images!and!web-pages.
!
Open an Activity/Result
Display Tool Menu
Start Measurement
Go to Home Screen
Create New Result
Measurement Settings
Stop Measurement
Exit Coach
+ +Activity+Screen!!
to!display!elements!of!Activity/Result!
!
!
!
+Diagrams+Screen!!
to!display!data!in!diagrams!
!
!
+!
+Texts+Screen!!
to!display!texts!(not!editable!by!students)!
!
!
!
!
+Student+Texts+Screen!!
to!display!Student!Texts!
!
!
!
!
+Sensors+Screen!
to!live!display!the!measured!values!
!
!
!
+ +Tables+Screen,+!
to!display!data!in!tables!
!
!
!
+Images+Screen!!
to!display!images!
!
!
!
+Web-pages+Screen!
to!display!web!pages!
!
!
!

!
!
!
TYPICAL+MEASUREMENT+PROCEDURE+++
!
When! working! with! VinciLab! as! a! standalone! device! VinciLab!is! controlled! by! its! touch!
screen!and!Coach!is!running!on!VinciLab.!!!
!
•
Turn!VinciLab!on!by!pressing!its!power!button.!Wait!until!the!Home!Screen!appears.!!
•Ensure!VinciLab!has!sufficient!battery!power!or!is!connected!to!a!power!supply.!!
•On!the!Home!Screen!tap! !to!open!the!Coach!Application.!
•Connect!sensor(s)!to!the!sensor!input(s)!of!VinciLab.!!!
!
•Create!a!new!Coach!Result:!! ! Or!open!an!existing!Coach!Activity/Result:!!
-
Tap! !or! tap! !and! select! New.! When!
you! want! to! use! only! the! internal! Sound!
sensor!select!New+(Sound+Only).+!!!
-
A!new!Result!opens.!!
-Coach!automatically!detects!and!identifies!
the! connected! sensor(s).! When! a!
connected! sensor! is! identified!then! its!
name! appears! in! the! Activity! Screen! and!
its! live! readings! on! the! Sensors! Screen.!
When!a!sensor!is!not(identified!then!it!has!
to! be! manually! selected! from! the!
CMA!
Sensor!Library.!
To!select!a!sensor!from!the!
Sensor! Library! go! to! Sensors+ Screen,! tap!
!and! select! Sensor+ Settings,! tap! a!
sensor! input! tab! to! which! the! sensor! is!
connected,! tap! Choose!(or! None)+ and!
select!a!sensor!from!the!list.!
-
Tap! !or! tap! !and! select! Open!or+Open+
CMA+Project….!Browse!to!select!the!desired!
Activity/Result.!Confirm!with! .!
-
The!Activity/Result!opens.!!
-Coach! automatically! detects! and! identifies!
the! connected! sensor(s).! If! the! identified!
sensor! is! different!from! the! sensor! defined!
in! the!Activity/Result!then!the!sensor!listed!
on! the! Activity! Screen! is! displayed! in! red.!
The!sensor!digital!display!shows!information!
about! the! sensor! defined! in! the! Activity!
(red)! and! the! sensor! identified! by! VinciLab.!
Connect!the!defined!sensor!or!change!it!into!
the! detected! sensor! by! touching! Exchange.!
This! feature! is! not! available! for! sensors,!
which!cannot!be!identified.!!
•Tap! !to!check!the!live!readings!of!the!sensors.!The!live!data!are!not!stored!in!VinciLab’s!
memory.!
•You! are! ready! to! start! a! measurement.! The! measurement! will! be! executed! according! to!
the!given!measurement!settings.!Tap! !to!check!or!change!these!settings.!!
•Tap! !to!start!collecting!data.!!!
oIn!most!cases,!Coach!directly!starts!the!measurement.!!
oIf!triggering!is!enabled!then!the!measurement!is!started!automatically!when!the!trigger!
conditions!are!met.!
oFor! a!Manual!measurement! tap! !to! collect! a!single!measurement.!When! keyboard!
input!is!requested!then!the!value!of!one!or!more!quantities!has!to!be!typed!in.!
•The!measurement!stops!when!the!specified!measurement!time!(time-based)!or!specified!
number!of!samples!(manual)!has!been!reached.!Tap! !to!interrupt!the!measurement.!!
•To!save!your!Result!go!to! ,!tap! !or!tap! !and!select!Save!or!Save+As….!!
!
Warning:!
When!tapping! !and!starting!a!new!data!collection,!existing!data!is!overwritten!by!!
the!new!data!without!any!warning.!To!avoid!losing!any!data!save!your!Result!first.!
!

!!
!
!
!
!
!
!
!
!
USING+VINCILAB+WITH+COMPUTER+AND+TABLET++
VinciLab! can! be! used! as! a! lab! interface! connected! (via! USB! or! Wi-Fi)! to! computers! (Mac! and!
Windows),!tablets!(iPad,!Android)!and!Chromebooks.!Coach!7!and!Coach!7!Lite!programs!and!
apps!support!such!measurements.!!
!
!
1.+CONNECTING+VINCILAB+FOR+THE+FIRST+TIME++
Before!you!start!to!use!VinciLab!with!the!computer!via!the!USB!cable!we!recommend!to!first!
install!the!latest!version!of!the!Coach!7!or!Coach!7!program!on!your!computer.!In!most!cases!
the!VinciLab!installation!is!automatically!executed!the!first!time!VinciLab!is!connected!to!the!
USB! port! of! the! computer.! After! successful! installation! VinciLab! is! shown!under! Network!
adapters!(Windows)/Ethernet! cards! (MAC).! If! the! driver! is!not! successfully!installed! or! there!
are!problems!with!communication!between!VinciLab!and!computer!consult!the!VinciLab!User’s!
Manual.!!
!
2.+USING+VINCILAB+FOR+DATA+COLLECTION+WITH+A+COMPUTER+AND+A+TABLET+
Coach!7!and!Coach!7!Lite,!as!well!for!desktops!
as! for! tablets,! support! measurements! with!
VinciLab.! During! such! measurement! VinciLab!
stays! connected! to! the! computer/tablet! via! a!
USB! cable! or! communicates! wirelessly! via! Wi-
Fi.! The! collected! data! are! transferred! in! real-
time!to!the!computer/tablet!and!the!course!of!
the! measurement! can! be! followed! directly! on!
the! computer/tablet! screen.! The! VinciLab!
screen!is!inactive!and!displays!the!image!shown!
here.!!
!
!
!
3.+TRANSFERRING+FILES+BETWEEN+VINCILAB+AND+A+COMPUTER+
Files,!can!be!transferred!between!a!computer/tablet!and!the!folder!‘My!files’!on!VinciLab!via:!!
•the!USB! connection.! To! get! access! to! VinciLab! in! Windows! Explorer! or! in! Mac! Finder,!
VinciLab!needs!to!be!first!mounted!as!a!network!location.!!
•a!USB!stick!memory.!Insert!your!USB!stick!into!the!USB!port!of!VinciLab.!!
•an! e-mail,! files! can! be! attached! and! send! from! VinciLab.! For! this! VinciLab! has! to! be!
connected!to!a!network.!!
For!details!see!the!VinciLab!User’s!Guide.!!
!
4.+DISPLAYING+THE+VINCILAB’S+SCREEN+ON+A+COMPUTER+OR+A+MOBILE+DEVICE+
VinciLab!offers!Data!Share!via!Virtual!Network!Computing!(VNC),!which!makes!possible!to!view!
the! VinciLab! screen! on! any! computer! or! a! mobile! device.! The! VNC! protocol! can! run! via! a!
network!connection!but!also!via!a!USB!connection.!To!allow!this!a!VNC!Viewer!program!needs!
to!be!installed!on!the!controlling!device!and!remote!connection!has!to!be!established!between!
the!devices.!Such!VNC!Viewers!are!freely!available!for!all!platforms.!
+
CENTRE+FOR+MICROCOMPUTER+APPLICATIONS+++