COLUMBIA SPECIFICATIONS
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com email: info@columbiasinks.com
©2019 Columbia Products
HANDS-FREE FLOOR MOUNTED WASH STATIONS
Parts List
(1) Floor mount wash station
(1) Leg assembly set
(4) Washers and nuts for connection sink to leg assembly set
(2) Double foot pedal valve (bottom mount) with 2 nuts
(2) Swivel gooseneck spout with aerator
(2) Connecting tube for valve to spout connection
(4) Fittings, brass, 0.375” male compression and 0.375” male NPT
(1) Strainer assembly with basket
Installation Instructions
Step 1
1. 2 and 3-Person models require leg assembly.
2. Place wash station sink on leg assembly and secure with hardware (provided).
3. Establish sink location.
4. Mark the floor where the four holes are at the base as shown in illustration A.
5. Drill holes as required for mounting hardware. (Hardware not included).
Step 2
1. Install spout assembly to the sink.
2. Install elbow fitting (provided) to the spout assembly.
3. Connect one side of the supply line (provided) to the spout assembly.
4. Install strainer assembly.
Step 3
1. Install elbow fitting to valve.
2. Install foot pedal valves under the leg assembly cross bar if not mounted already.
3. Attach connecting tube from the spout to the foot pedal valve.
Step 4
1. Secure wash station to the floor.
2. Connect waste line to strainer assembly.
3. Connect water supplies (hot and cold) to valves.
Step 5
1. Remove aerator from the spout assembly and flush water line by pressing pedal for
30 seconds.
2. Check connections for leaks. Replace aerator onto the spout assembly.
3. Seal gap between bowl and leg assembly as shown in illustration B.
4. When mounting against wall, we recommend sealing top of backsplash to wall as shown in
illustration C.
Tools Required
Tape Measure
Adjustable Wrench
Drill Motor and Drill Bits
Pipe Wrench
Level
Safety Glasses
Screw Drivers: 1 Phillips & 1 Standard
Pencil
Socket Wrench
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certied under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Illustration A
Illustration B
Illustration C

3
COLUMBIA SPECIFICATIONS
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com email: info@columbiasinks.com
©2019 Columbia Products
HANDS-FREE FLOOR MOUNTED WASH STATIONS
Valve Repair Instructions
Note: Valves are designed to be repaired without having to be disconnected from mount or plumbing.
1. Turn off water source. Do not remove valve from sink.
2. Remove pedal assembly using a 15/16” open end wrench or socket wrench. As shown in
illustration A.
3. Using a 1” deep socket wrench remove insert assembly parts as show in illustration B.
4. Replace with new repair kit as shown on illustration C.
5. Reinstall pedal assembly and turn water source on.
Trouble Shooting Guide
Problem Possible Cause To Diagnose Remedy
Water drips from spout
or valve stem assembly.
Flat washer on the
stem/plunger is worn.
To determine if the leak source is from the hot or cold side shut
cold water source off. See if water still leaks from the spout. If
leak continues then repair hot side if not repair cold side.
We recommend installing valve repair
kit.
Water leaks from the
front of the valve.
O-Rings on the
plunger are worn out.
Visually determine whether the cold or hot side is leaking. We recommend replacing threaded
insert, plunger assembly & spring.
See illustrations below.
Illustration A
Illustration B
Illustration C

1/2" NPT Inlet
A
C
B
E
D
J
H
P
K
M
I
Q
L
O
1/2" NPT Inlets
A
C
B
E
F
G
H
P
K
M
I
Q
L
N
Part No. Decription Application
A
1041 Operated, Long Foot 103/104/105/106 (S) (L)
B
1042 Operated, Short Foot 101/102 (S) (L)
C
1043 Operated, Knee 109/110/111/112 (S) (L)
D
1049 Bolt & Nut Set (Stainless) All Single Valves
E
1050 Jam Nut (Stainless) All Valves
F
1051 Bolt & Nut Set (Stainless) All Double Valves
G
1052 Bracket All Double Valves
H
1053 Threaded Insert (Low Lead) All Valves
I
1053S Threaded Insert (Stainless) All Valves
J
1054 Bracket All Single Valves
K
1055 Plunger Assembly (Low Lead) All Valves
L
1055S Plunger Assembly (Stainless) All Valves
M
1056 Spring (Stainless) All Valves
N
1057 Body only, Double Valve (Low Lead) All Double Valves
O
1058 Body only, Single Valve All Single Valves
P
1061L Replacement Kit (Low Lead) All Valves
Q
1061S Replacement Kit (Stainless) All Valves
Replacement Parts
P 1061L Replacement Kit includes
one each: 1053L, 1055L, 1056L
Q1061S Replacement Kit includes
one each: 1053S, 1055S, 1056S
Double Knee or Foot Pedal
4
COLUMBIA SPECIFICATIONS
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com email: info@columbiasinks.com
©2019 Columbia Products
HANDS-FREE FLOOR MOUNTED WASH STATIONS
Single Knee or Foot Pedal

5
COLUMBIA SPECIFICATIONS
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com email: info@columbiasinks.com
©2019 Columbia Products
HANDS-FREE FLOOR MOUNTED WASH STATIONS
1.5” (38mm)
20” (508mm)
2” (51mm)
54 Floor
10.25”
(267 mm)
40” (1017mm)
20” (508mm)
37” (940mm)
20” (508mm)
11”
(305mm)
18”
(610mm)
11”
(305mm)
20”
(508mm)
2” drain hole
16.5”
(407mm)
10”
(254mm)
8” (203mm)
1.5” (38mm)
2” (51mm)
1.5” (38mm)
6.75” (171mm)
10” (254mm)
.875” (22mm)
dia. holes (2)
27” (686mm)
45º
2.875” (73.02mm)
.75” (20mm)
7.5” (191mm)
.5” R
(12.7mm)
.5” R (12.7mm)
33.8125” (858.8mm)
Side
Top
Floor Mounting Detail
.5” dia.
Floor
Mounting
Holes
10.5” on
Center
1.5” Leg
Thickness
.75” From
Edge of Leg
to First Hole
Hole Configurations
Front
Supply Line Detail
Back Splash
To Spout
.5” MNPT
Inlet Cold
.5” MNPT
Inlet Hot
Double
Knee or
Foot Pedal
Valve
3/8” Male
Compression
Supply Line
from Valve
to Spout
.5 NPT Supply Line
to Spout

6
COLUMBIA SPECIFICATIONS
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com email: info@columbiasinks.com
©2019 Columbia Products
HANDS-FREE FLOOR MOUNTED WASH STATIONS
Leg Assembly
x 6
This manual suits for next models
1
Table of contents
Popular Commercial Food Equipment manuals by other brands

Diamond
Diamond AL1TB/H2-R2 Installation, Operating and Maintenance Instruction

Salva
Salva IVERPAN FC-18 User instructions

Allure
Allure Melanger JR6t Operator's manual

saro
saro FKT 935 operating instructions

Hussmann
Hussmann Rear Roll-in Dairy Installation & operation manual

Cornelius
Cornelius IDC PRO 255 Service manual

Moduline
Moduline HSH E Series Service manual

MINERVA OMEGA
MINERVA OMEGA DERBY 270 operating instructions

Diamond
Diamond OPTIMA 700 Installation, use and maintenance instructions

Diamond
Diamond G9/PLCA4 operating instructions

Cuppone
Cuppone BERNINI BRN 280 Installation

Arneg
Arneg Atlanta Direction for Installation and Use