Heavy Duty Hoist
Model: GT
1
00
PN: 751260 12V 751321 12V 751310 12V 751350 12V 931076 12V
751375 24V 751365 24V 931050 24V
Introduction
Feature
Line lifting: 544 kg / 1,200 lb wire rope first layer
Wire rope: 4.8 mm × 18.3 m (3/16" × 60′) galvanized aircraft A7 × 19
Brake: Both Mechanical cone brake and permanent motor dynamic
brakes
Control: Handheld pendant switch powers the hoist
Unpacking
.Hoist assembly…………………………………………………………… 1 pc
.Control box………………………………………................................... 1 pc
.Remote control except for PN:751310………….……………………… 1 pc
.Wire rope with clevis hook except for PN:751260…………….………. 1 pc
Read this manual carefully
You should carefully read and understand this manual before operating it.
Careless hoist operation may result in personal injury hazards or property
damage.
Information requesting or parts ordering
Please specify the following information:
.Hoist PN .Part description
.Serial number .Replacement part number
.Quantity for each part
Installation
Before using the hoist, make sure all electrical components have no corrosion
or damaged; the environment should be clear and dry.
Hoist mounting
Four (4) M10 x 30L 8.8 grade with 44 N-m torque settings (maximum) high
tensile steel bolts must be used in order to sustain the loads imposed on the
winch mounting.
Wire Rope Replacement
.Feed the end of the wire rope into anchor hole in
the drum and make a self-circle on the anchor
pocket. Insert a wedge in the self-circle and tighten
the rope for securing purpose.
.Make sure the first layer of wire rope is tight and
maintain a freeboard at least 1.5 x rope diameter.
.Wire rope shall be wound in an under-wound
orientation only.
.To compensate for uneven spooling and the
decrease in line pull capacity as the drum fills up, use as short a wire rope as
practical.
Wiring Diagram
•Connect positive/negative terminal cables to the winch motor.
•Attach the ground lead firmly to the negative (–) battery terminal and power
lead to the positive (+) battery terminal. The voltage drop for the winch
motor must not exceed 10% of the nominal voltage of 12/24V DC.
Warning
.The operator shall always work in compliance with the operating instructions.
.Overload shall be forbidden and overload protection shall be required.
.Ban on transporting persons and excessive inching shall be avoided.
.Don’t try to move obstructed loads and side-pull of load is not allowed
.The rope winding on the drum shall remain 5 wraps from the drum.