Communication Devices DC Series User manual

Copyright © Communication Devices Inc ii
Warranties, Disclaimers and Restriction
A.1 Copyright
Notice
This equipment, all software, firmware and the
entire contents of this manual are the copyright
property of Communication Devices Inc.,
Boonton, NJ 07005 USA with all rights
reserved.
The information contained in this manual is
considered proprietary to Communication
Devices Inc. And is intended for the exclusive of
the original purchaser of the equipment.
A.2 Warranty
Communication Devices Inc. Warranties to the
original purchaser that these devices are free
from defects in material or faulty workmanship,
in normal use for a period of one (1) year from
the date of purchase.
This warranty is limited to repair or replacement
at the option of Communication Devices Inc., of
any defective part or component which within
one (1) year of the original purchase is
determined by Communication Devices Inc. To
be defective. All warranty repairs will be made at
Communication Devices Inc. Main factory in
Boonton, NJ 07005.
A.3 Disclaimer
While extreme care has been taken in the
preparation of the design, software, firmware,
hardware and documentation, Communication
Devices Inc accepts no liability. For loss of
profits or any other incidental, special or
consequential damage suffered by the purchaser,
even if Communication Devices Inc. has been
advised of the possibility of such damages, nor
for the claim against the purchaser by any other
party.

Copyright © Communication Devices Inc III
Table of Contents
1. SERIAL POWER CONTROL MODULE......................................................................................1-1
1.1 PCM621 –4TERMINAL BLOCKS 10 AMP EACH...........................................................................1-1
1.2 POWER CONNECTIONS.................................................................................................................. 1-1
1.3 SERIAL CONNECTIONS..................................................................................................................1-2
1.4 SERIAL PINOUTS......................................................................................................................1-2
1.5 GETTING STARTED .......................................................................................................................1-3
1.5.1 Connecting Power to Device...............................................................................................1-3
1.5.2 Power on.............................................................................................................................. 1-3
1.5.3 Serial Power Control Port................................................................................................... 1-3
1.5.4 RJ45 Pinout.........................................................................................................................1-4
1.5.5 Cable connection for Power Modules .................................................................................1-4
1.5.6 Service .................................................................................................................................1-4
3. MENU’S.............................................................................................................................................3-5
3.1 INITIAL MENU...............................................................................................................................3-5
3.2 POWER CONTROL 1 ......................................................................................................................3-6
4. LINKING PCM621’S........................................................................................................................4-7
5. PROGRAMMING.............................................................................................................................5-8
5.1 PROGRAMMING MENUS................................................................................................................5-8
5.2 SCRIPT FILE ..................................................................................................................................5-9
5.3 LOADING THE SCRIPT FILE ....................................................................................................... 5-10
6. ENVIRONMENTAL.......................................................................................................................6-11
FIGURE 1PCM621 REAR VIEW..................................................................................................................... 1-1
FIGURE 2PCM621 FRONT VIEW.................................................................................................................. 1-2
FIGURE 3CDI RJ45 SERIAL PINOUT....................................................................................................... 1-2
FIGURE 4CDI RJ45 SERIAL PINOUT....................................................................................................... 1-4
FIGURE 5PCM621 MENU............................................................................................................................ 3-5
FIGURE 6PCM621 POWER CONTROL MENU ............................................................................................... 3-6
FIGURE 7PCM621 POWER CONTROL STATUS ............................................................................................. 3-6
FIGURE 8PCM620 LINK 2......................................................................................................................... 4-7
FIGURE 9PCM621 LINK 1.......................................................................................................................... 4-7
FIGURE 10 PCM621 PRIMARY..................................................................................................................... 4-7
FIGURE 11 PROGRAMMING MENU................................................................................................................ 5-8
FIGURE 12 SCRIPT LOAD ............................................................................................................................ 5-10

Copyright © Communication Devices Inc 1-1
1. Serial Power Control Module
1.1 PCM621 – 4 Terminal Blocks 10 Amp Each
The Power Control Module “PCM621” amp is a quad DC power relay designed to work in conjunction
with any Serial interface, However the device has additional features when used with a CDI Secure Out of
Band Management device. The purpose of the device is to remotely power reset DC devices that are in a
“locked up” condition.
The PCM621 will interrupt the power to a connected device when it is commanded to “switch off” the
power relay to that particular output connector. The PCM621 can “reboot” the connected device by
interrupting the power for a few seconds, or it can turn off the device off for longer periods of time.
Features of the PCM621:
1. Four Separate DV terminal blocks 10AMPs each.
2. Voltage – 3VDCVDC to 100VDC
3. Current – 10AMP
4. Device DOS NOT supply DC current it only passes it through.
1.2 Power Connections
Wire Gauge can be from 12 to 24AWG, Solid Preferred.
The PCM621 requires an external 12VDC power supply, provided with each PCM621.
The PCM621 has 4 DC terminal blocks:
1. The Blocks are “screwless”, and work on pressure to hold the wires in the blocks.
2. Solid wire will work best with the blocks as insertion force is required to depress the metal spring
in the circular hole in the block to allow the wire to be grabbed and held in the block
3. There is a square cutout above each circular hole where a paper clip or very small screwdriver can
be inserted to release the captive wire.
4. If stranded wire is used, a paper clip can be used in the square cutout to open the spring to allow
the stranded wired to enter the block. When the paper clip is removed the spring will release and
clamp down on the stranded wire to hold it in the block.
Figure
1 PCM621 rear view
WIRE
PAPER
CLIP

Copyright © Communication Devices Inc 1-2
1.3 Serial Connections
The PCM621 has Two Serial connections
1. Serial Input – this is connected the device that is controlling the PCM
a. This is a 9600 BAUD interface
b. It is pinned out to connect directly with a straight RJ45-RJ45 cable to the SERIAL HOST
PORT of ANY CDI OOB device.
2. Serial Output – This can connect to the Serial Input of an additional CDI PCM621 device to
realize more power control interfaces off of one serial interface.
a. The MASTER PCM621 device will DETECT any co0nnect CDIPCM devices and
present a SINGLE MENU to the OOB device.
b. It is pinned out to connect directly with a straight RJ45-RJ45 cable to the input of a
connected CDI SERIAL PCM device.
c. You can LINK multiple PCM621 devices together.
3. The connection to All of the interfaces is a STRIAGHT RJ45 to RJ45 cable.
1.4 SERIAL PINOUTS
Figure
2 PCM621 Front View
CONNECT TO SERIAL PORT OF OOB DEVICE
Figure
3CDI RJ45 SERIAL PINOUT

Copyright © Communication Devices Inc 1-3
1.5 Getting Started
1.5.1 Connecting Power to Device.
The device will connect to a standard alternating current (AC) wall outlet (100VAC ~ 240VAC,
50/60Hz). The socket outlet should be installed near the equipment and should be easily accessible. Make
sure the power cord supplied is of the correct type for the country being installed.
The user is to disconnect all telecommunication network connectors before disconnecting the power
supply cord. In addition the equipment should be installed by a qualified service person and connected to a
socket-outlet with a protective earthing contact.
In English: equipment must be connected to an earthed mains socket-outlet.
In Finland: Laite on liitettava suojakosketinpistorasiaan
In Norway: Apparatet ma tilkoples jordet stikkontakt
In Sweden: Apparaten skall anslutas till jordat uttag
The power parameters are:
Voltage
Frequency
Current
110VAC
60Hz
10amp
240VAC
50Hz
6amp
1.5.2 Power on
When the device is properly powered, the status LED on the front panel will illuminate. This is an
indication that the device is powered and the relayed is closed (“on”). When the relay is opened (“switched
off”) the LED will extinguish.
1.5.3 Serial Power Control Port
Each PCM has two RJ45 interfaces. The INPUT interface is used to connect to an OOB device through a
straight RJ45-RJ45 cable, and accepts serial commands to control the device. The Power Modules are used
to power cycle the remote devices that may have become inoperative. This will reset the device and usually
restore operation.
Power Ports can also be used to shut down (turn off the power to) a device that should not be operating.
The power can also be restored to a Power Module that has been turned off.
The SERIAL OUTPUT interface is used to LINK PCM’s together using straight RJ45-RJ45 cables. The
OUTPUT of the first PCM is connected to the INPUT of the next PCM. Multiple PCM’s can be linked to
realize larger power control configurations from a single serial interface.
CAUTION!
THIS DEVICE SHOULD BE INSTALLED BY A
QUALIFIED SERVICE PERSON AND
MUST BE CONNECTED TO AN
EARTHED MAINS SOCKET-OUTLET

Copyright © Communication Devices Inc 2-4
The MASTER PCM will detect all devices connected through the OUTPUT interface and present a single
menu to the OOB device connected to the SERIAL INPUT interface.
1.5.4 RJ45 Pinout
The RJ45 connection uses serial 9600 BAUD 8 Data bits, no Parity.
1.5.5 Cable connection for Power Modules
All RJ45-RJ45 cables are straight.
1.5.6 Service
There are no user serviceable parts inside the PCM. Do not open or
attempt to repair this device. Return it to the factory if it is suspect of
operating improperly.
Figure
4CDI RJ45 SERIAL PINOUT

Copyright © Communication Devices Inc 3-5
3. Menu’s
3.1 Initial menu
P1 – Power Port 1
P2 – Power Port 2
P3 – Power Port 3
P4 – Power Port 4
MP Control Multiple Power Ports
Figu
re 5 PCM621 Menu

Copyright © Communication Devices Inc 3-6
3.2Power Control 1
Enter P1 to control POWER OUTPUT 1
You will be prompted for:
1 Timed reset : This will turn the power off for 5 seconds and turn it back on automatically
2 Turn Off : This will turn the power off to the output forever until you turn it back on
3 Turn On : This will turn the power back on to the power output
An Escape will ALWAYS return you to the previous menu
Figure
6 PCM621 Power Control Menu
Figure
7 PCM621 Power Control Status

Copyright © Communication Devices Inc 4-7
4. Linking PCM621’s
You can link several PCM621’s and PCM620’s together using serial RJ45 cables to achieve more power
control outputs off of a single Serial connection to an OOB device.
When you link devices together, they “learn” about each other so that the “First” PCM621 will display a
menu including all the connected devices. So you may see 8 Power powers instead of two.
The Linked devices will assume higher numbers in the menu so that the primary device may show
P1 – Power Port 1
P2 – Power Port 2
P3 – Power Port 3
P4 – Power Port 4
P5 – Power Port 5
P6 – Power port 6
P7 – power Port 7
P8 – Power Port 8
OOB DEVICE SERIAL PORT
Figure
10 PCM621 Primary
Figure
9 PCM621 LINK 1
Figure
8 PCM620 LINK 2
STRAIGHT RJ45 cables
PCM621
PCM621
PCM620

Copyright © Communication Devices Inc 5-8
5. Programming
5.1 Programming Menus
To access the programming menu’s enter “$$CDI$” followed by the ENTER KEY in the main menu.
You will receive
1 – Load Configuration
2 – Retrieve Configuration
3 – Set to Default
Figure
11 Programming Menu

Copyright © Communication Devices Inc 5-9
5.2 Script file
Enter “2”
You will receive the SCRIPT FILE that will load these parameters
The Script file can be saved and edited then sent to the device to program the port names.
The script file uses:
a Hash “#” to denote anything after as a COMMENT
a Semi Colon “;” to denote the end of a field or section
LABELS to denote what is being configured.
For PCM620 the only files are:
DEVICENAME:
POWER PORT NAMES:
END:
#SCRIPT FILE START
#Smart PCM Configuration
DEVICENAME:
# Device name can be 25 characters followed by a semicolon
CDI POWER CONTROL 620;
# ;
;
#POWER PORT NAMES
# You can customize the power port names as well as the number of seconds for power recycle - default=5
# Power port names can be 50 characters in length
POWER:
P1=CISCO SWITCH2-POWER1,5;
P2=NAME-POWER23456789,10;
;
END:
;
Save the SCRIPT FILE IN TEXT FORMAT NOT WORD OR ANYTHING WITH FORMATTING –
USE NOTEPAD - and change the DEVICE NAME or PORTS NAMES
Then go into the PROGRAMMING MENU by entering $$CDI$ followed by the ENTER KEY

Copyright © Communication Devices Inc 5-10
5.3Loading the SCRIPT file
Enter the PROGRAMMING MODE via $$$CDI$ followed by the ENTER KEY
Get your new script and highlight all the text.
Copy it to the clipboard.
Enter 1 – to Load the script
Then PASTE the script into the device.
You will see “READING DATA” several times form the device and then it will display the new load
Figure 12 Script Load

Copyright © Communication Devices Inc 6-11
Here is the script file that was used to load the above
#SCRIPT FILE START
#Smart PCM Configuration
DEVICENAME:
CDI POWER CONTROL 620;
# Device name can be 25 characters followed by a semicolon
# ;
;
#POWER PORT NAMES
# You can customize the power port names as well as the number of seconds for power recycle - default=5
# Power port names can be 50 characters in length
POWER:
P1=DSL ROUTER 1,5;
P2=CABLE ROUTER 2,10;
;
END:
;
6. Environmental
•Operating temperature: 0º Celsius to 45º Celsius (32º Fahrenheit to 113º Fahrenheit)
•Storage temperature: -20º Celsius to 70º Celsius (-4º Fahrenheit to 158º Fahrenheit)
•Operating humidity: 10% to 85%, non-condensing
•Storage humidity: 5% to 90%, non-condensing
•Operating altitude: up to 10,000 ft (3049 m)
•Storage altitude: up to 15,000 ft (4573 m)
•Voltage Parameters 100~240VAC 20~ 10Amp 50/60Hz
Don’t forget this Semi colon to end
This manual suits for next models
1
Table of contents
Other Communication Devices Control Unit manuals
Popular Control Unit manuals by other brands

Baumuller
Baumuller b maXX BM4-O-CAN-03 Instruction handbook

HP
HP HPE FM 2072 installation guide

TriangleTube
TriangleTube Prestige Trimax 175 installation instructions

Siemens
Siemens Flowrite 599 Series Technical instructions

LOVATO ELECTRIC
LOVATO ELECTRIC EXP10 00 quick start guide

Rabbit
Rabbit RCM3720 Getting started

SIMCom Wireless Solutions
SIMCom Wireless Solutions SIM7600A-H user manual

Infineon
Infineon Easy 1B Assembly instructions

Carel
Carel Ultracap instructions

Ricoh
Ricoh 411402 - EFI Fiery EB-105EX Controller printing guide

Ross
Ross openGear FSR-6201 user manual

ASAHI
ASAHI 55 Installation, operation and maintenance manual