COMPX eLock NARC iD User manual

NARC iD
Central Storage Unit (CSU)
Thank you for purchasing CompX NARC iD CSU with
built-in CompX eLock. The information contained in
these instructions is intended to serve as a guide to
allow NARC iD CSU to be quickly and easily put into
service. CompX eLock can be configured to work in
conjunction with existing 802.11b/g/n networks. For
complete set up instructions for networked and stand-
alone eLocks, please see the “Help” section in CompX’s
LockView v5iDPro software.
Central Storage Unit dimensions with CompX eLock installed
Central Storage Unit dimensions with CompX eLock — components
1
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
RFID antenna
(inside)
Control
electronics
Integrated
motorized
latch
Power supply
connector
Three shelves
with foam
capsule holders
Door position
switches

NARC iD Central Storage Unit — continued
NARC iD Central Storage Unit (CSU) — Instructions
2
What’s in the box?
w1 - NARC iD CSU box
w3 – shelves and foam capsule holders
w6 – #10 x ¾ Phillips pan head sheet metal screws to hang
NARC box
w1 - warranty card
w1 - serial code sticker set
w1 - in-box instructions
w1 - power supply and power supply cord
What’s needed?
wDrill
w9/64” drill bit (pilot hole for mounting screws)
w#3 Phillips bit or driver
wTape measure
Care and Cleaning
To clean the surface of the eLock, apply non-acid based
cleaner to a clean cotton cloth; do not spray cleaner directly
on the eLock.
Wipe down keypad and housing taking care around the USB
connector and edges of keypad. Wipe excess cleaner off of
all surfaces.
Installation
NARC iD CSU can be installed using the 6 predrilled key
holes and supplied #10 x ¾ Phillips pan head screws. Be
sure to mount the box in a location that provides enough
clearance for the doors to open.
The NARC iD CSU system comes with a power supply
connector intended to be connected to the 120VAC / 12VDC
power supply (provided). Insert the male end into the female
jack on the side of the NARC iD CSU box.
The power supply cord needs to be connected to the power
supply and to 120VAC.
The NARC CSU iD system comes pre-programmed with one
PIN user 12345. If access to the box is required during
installation, use the mechanical key or type 1-2-3-4-5-
ENTER to access the box.
CSU mounting
hole locations

NARC iD Central Storage Unit — continued
3
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
1. Dot matrix LCD
2. Network button (blue LED)
3. “UP” button
4. “NEXT/SELECT” button
5. “BACK/CANCEL” button
6. “MENU” button
7. “DOWN” button
8. + Button
9. - Button
10. Low battery indicator
(yellow LED)
11. Alpha-numeric keypad
12. HID Prox or HID iCLASS
reader location
(if equipped)
13. “ENTER” button
14. “CLEAR” button
1
2
3
4
5
6
78 9 10
11
14
13
12
NARC iD controller button layout
NARC Box
with NARC iD
installed Drug
Tote
Capsule Controlled
substance

NARC iD Central Storage Unit — continued
NARC iD Central Storage Unit (CSU) — Instructions
4
Unit Features:
wProvided with 802.11 b/g/n configuration that uses
the existing infrastructure for actual 2-way read/write
communication
wEach NARC iD CSU system can hold up to 3,000 Users
wOptional card reader to read existing HID Prox or HID iCLASS
credentials that can be programmed to operate each NARC
iD CSU system
wRemote Notification System with programmable escalating
alerts via SMTP email; SMS text, voice and fax (Networked
eLock & LockView Software required)
wSpring bolt latching mechanism provides automatic relocking
wDoor position switches
wMembrane keypad with stainless steel domes provides
durable performance and easy cleaning
Setting up the eLock
Getting Started Out of the Box
For Networked (802.11 b, g or N) 300 Series eLocks,
please follow the CompX eLock Database & Network
Configuration & Install Manual and the CompX LockView
Software Instruction Manual before proceeding.
The eLock is shipped in FACTORY mode.
Methods to begin building
a database of eLocks in
CompX’s LockView Software
For Networked (802.11 b, g or N) eLocks, please follow the
CompX eLock Database & Network Configuration & Install
Manual and the CompX LockView Software Instruction
Manual before proceeding.
LockView Mode Instructions
(For complete details on how to build a database of users
and eLocks, see the CompX LockView Software Instruction
Manual and CompX eLock Manual Programming Guide)
To enable the NARC iD CSU system SETUP mode you will
need the setup code for the box. Included with each NARC iD
CSU system is a Setup code that is on a set of green 2”x1”
labels. The Setup Code is the set of numbers immediately to
the right of “Setup Cd” on the green label set.
Press and hold CLEAR. The NARC iD CSU LCD will display
“Setup code needed to enter setup mode” At this screen,
type the Setup Code and press ENTER. CompX LockView
Software v5 must be installed and the eLock must be in
SETUP mode before continuing.

NARC iD Central Storage Unit — continued
5
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
There are two methods that can be used to add eLocks to
the LockView software:
Automatic Method
1. With the eLock in SETUP mode, connect the eLock via the
USB cable to the computer on which LockView is installed.
2. Login to LockView.
3. After 30 seconds, the below will appear.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.
4. Click Yes.
5. The below will appear.
Type in the name of the lock.
**Once a Lock Name has been chosen in LockView, it can
not be changed. Please be sure the name that is chosen is
the one that will be used in the future.
6. Click Save when done.
7. Go to Lock Editor tab in Lock/User Editor.
8. Left click to highlight the name of the lock and then click Edit
Lock.
9. Verify and/or adjust all other lock parameters. (See LockView
Instruction Manual for complete details.)
10. Click OK when done.
Manual Method
1. Login to LockView.
2. Go to Lock/User Editor; Lock Editor tab and click Add Lock.
3. Enter the required information: Lock Name; Lock Serial
Number and Setup Code (supplied on green sticker set as
Setup Cd).
**Once the Lock Name has been chosen in LockView, it can
not be changed. Please be sure the name that is chosen is
the one that will be used in the future.
4. Verify and/or adjust all other lock parameters and click OK.
(See LockView Instruction Manual for complete details on
these options)
5. Connect the eLock via the USB cable to the computer on
which LockView is installed.
6. After 30 seconds, the lock will be updated in LockView. Click
Refresh to prompt the update.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.
Please use the LockView v5 software to create a database
of valid users and add them to the lock. This needs to be
completed before operating the lock. See LockView v5
Instruction manual for details regarding adding users to
NARC iD CSU.
Operating the eLock
Follow the instructions below to operate the eLock.
PIN CREDENTIAL
1. Enter a valid PIN (between 4 - 14 digits) and
2. Press “ENTER.”
CARD CREDENTIAL
If the eLock is equipped with a card reader
(HID Prox or HID iCLASS)
1. Present a valid card within range of the HID reader
DUAL CREDENTIAL
If the User requires a dual credential
1. Enter a valid PIN and press “ENTER” (for keypad credentials)
or present a valid card (for HID Prox or HID iCLASS).
2. Enter the second credential (4-14 digit PIN) and press
“ENTER.”
NOTE: THE SECOND CREDENTIAL MUST ALWAYS BE
A 4 - 14 DIGIT PIN
STOP

NARC iD Central Storage Unit (CSU) — Instructions
6
NARC iD Central Storage Unit Interaction Guide
Lock Menu
To enter the Lock Menu press the MENU button on the
keypad.
You will be prompted to enter a valid credential: PIN, HID
prox or HID iCLASS card. After a valid credential is entered,
the following menu choices will appear.
The available menu choices are:
Date/Time Format
Brightness
Contrast
Beep Volume
RFID Test
WiFi Test
Use the UP and DOWN buttons to scroll through the menu
choices and hit NEXT/SELECT to activate one.
Date/Time Format
Choose the hour format (AM/PM or 24 hour) by using the UP
and DOWN keys to highlight the words to the immediate right
of HOURS. Use the +and –buttons to change the selection.
Choose the date format by using the UP and DOWN buttons
to highlight the words to the immediate right of DATE. Use the
+and –buttons to change the selection.
The available choices are:
MM/DD/YY (10/23/2019)
YYYY-MM-DD (2019-10-23)
DD-MMM-YY (23-OCT-19)
DD-MM-YY (23-10-19)
MMM D ‘YY (OCT 23’19)

7
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
NARC iD Central Storage Unit Interaction Guide — continued
Brightness
Use the +, -buttons to choose the brightness of the LCD
display. Alternately, choose 1-9 directly to choose the
brightness level. Press NEXT when done.
Contrast
Use the +, -buttons to choose the contrast of the LCD display.
Alternately, choose 1-9 directly to choose the contrast level.
Press NEXT when done.
Beep Volume
Use the +, -buttons to choose the Beep Volume. Alternately,
choose 1-9 directly to choose the Beep Volume. Press NEXT
when done.
RFID Test
This screen will turn on the RFID antennas and show real
time RFID tag reading from both antennas in the NARC iD
CSU box. Hit BACK/CANCEL to exit.

NARC iD Central Storage Unit (CSU) — Instructions
8
NARC iD Central Storage Unit Interaction Guide — continued
WiFi Test
NOTE: WiFi module in the NARC iD CSU system must be
configured and programmed before the test. See LockView
Database & Network Configurations & Installation Manual
for details.
This screen will turn on the WiFi system and connect to
the network. MAC address, IP address, Mask, and Gateway
address will be shown along with signal strength. Press
CLEAR to exit.

9
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
NARC iD Central Storage Unit Capsule Assembly Instructions
capsule
cap with
RFID tag
Put the controlled
substance into
the capsule,
verifying that the
narcotic is the
same as what is
listed on the RFID
tag, then put the
cap on the
capsule.
Line up the slots
in the cap and
capsule (to make
an alignment
tunnel), then
insert the wire
from the RFID tag.
Insert the locking
tab (arrow side
DOWN) on the
end of the wire
from the RFID tag
wire into the RFID
tag. Orientation
is CRITICAL. The
arrow on the latch
must be on the
bottom.
locking tab
arrow must be
on the bottom
to properly
engage
See color chart on page
15 for color / narcotic
matching.
1
2
4
Run the wire all
the way through
to the opposite
side of the cap.
3
controlled
substance

NARC iD Central Storage Unit (CSU) — Instructions
10
NARC iD CSU Capsule Assembly Instructions — continued
Place tote into
NARC iD box.
To ensure the locking
tab is fully inserted,
you must hear and
feel a click.
5
Close lid. Each tote
can carry a total
of 15 controlled
substances.
7
8
6
Place
capsules in
tote or CSU
cabinet.

11
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
NARC iD Central Storage Unit Operation
Normal Operation
The NARC iD CSU system automatically reads RFID tags
which are installed onto capsules containing controlled
substances that will be tracked with this system. Please see
the Capsule Assembly section page 9 for details on capsule
assembly. When the NARC iD CSU system is empty and no
tags are missing the LCD screen will show SAFE IS EMPTY.
Type a valid PIN code or present a valid card to the credential
reader to access the NARC iD CSU. (See CompX LockView
software instruction manual for information regarding adding
valid users.) Open the door and insert a tote containing RFID
enabled capsules with tags. When the door is closed, the
NARC iD CSU system will turn on and scan the box for tags.
The LCD screen will say SCANNING DRUGS PLEASE WAIT. It
will also show how many tags have been identified /
confirmed.
After the NARC iD CSU system has completed the scan, the
LCD will show how many tags are in the safe.
Access the NARC iD CSU system with a valid credential and
remove the tote (along with ALL tags). Close the door. The
NARC iD CSU system will scan the contents of the CSU and
the LCD will say SAFE EMPTY XX TAGS MISSING. (If all of the
tags were not removed, you will be immediately asked about
the reason the tag is missing, see below).

NARC iD Central Storage Unit (CSU) — Instructions
12
NARC iD Central Storage Unit Operation — continued
Remove some of the controlled substances from the totes
(in the illustration below, two tags are being removed).
Access the NARC iD CSU system with a valid credential and
return the tote to the CSU. The NARC iD CSU system will scan
the contents and report how many tags are missing. The LCD
will say ATTENTION XX narc tags are missing.
Press ENTER to continue. You will be asked about each
missing tag. If multiple tags are missing, you will see which
tag is being asked about along with the total inquiry. In this
example, the LCD says NARC TAG 1/2 fentaNYL 5-244 is
missing.
Press ENTER to continue to begin telling the NARC iD
CSU system the whereabouts of the missing controlled
substances. Depending how the system has been configured
in LockView there will be many choices available. These
include INCIDENT or CONSUMED, EXPIRED, LOST, BROKEN,
SKIP or TRANSFER. Press the UP, DOWN buttons or enter the
number corresponding to the whereabouts directly.
If a controlled substance is being transferred out of the CSU
to another NARC iD box, please choose TRANSFER.
In this example, INCIDENT was chosen.
If INCIDENT was chosen, you must enter a corresponding
INCIDENT number and press ENTER.
After the information regarding the whereabouts of the first
missing tag has been asked, the whereabouts of each
missing tag will be asked in the identical manner sequentially.

13
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
If the location of a specific missing tag is unknown or you
desire to enter the information later, you can choose SKIP. If
this is chosen, the NARC iD CSU system will continue to ask
about this missing tag after each scan.
After the whereabouts of each missing tag have been entered
the LCD will show the current contents of the box. If SKIP was
chosen for any tags, the LCD will show how many tags are
still unaccounted for.
In the previous examples, the user removed the entire
contents of the NARC iD CSU in the first step by removing the
tote, which contained all controlled substances. The NARC
iD CSU system assumed that the tote would be returning in
the near future with some controlled substances consumed
and some controlled substances still intact. In this case, the
whereabouts of the missing narcotics are not inquired with
the user until the tote is returned.
If, however, fewer than all tags are removed from the CSU, the
NARC iD CSU system assumes that this missing tag will be
consumed and immediately inquires with the user the
whereabouts of the missing tag(s). In the below illustration,
only one tag was removed from the NARC iD CSU system
which contained many tags.
If the INCIDENT system is not turned on, the NARC iD CSU
LCD will replace INCIDENT with CONSUMED and the user
will not be asked for an incident number.
NARC iD Central Storage Unit Operation — continued
If a controlled substance is being transferred out of the CSU
to another NARC iD box, please choose TRANSFER.
In this example, INCIDENT was chosen.
If INCIDENT was chosen, you must enter a corresponding
INCIDENT number and press ENTER.
After the information regarding the whereabouts of the first
missing tag has been asked, the whereabouts of each
missing tag will be asked in the identical manner sequentially.

NARC iD Central Storage Unit (CSU) — Instructions
14
NARC iD Central Storage Unit Operation — continued
KEY OVERRIDE
If the mechanical key is used to access the NARC iD CSU
system, the LCD will immediately show KEY OVERRIDE. If any
controlled substances are missing after the key override, the
NARC iD CSU system will continue to query the user about
missing tags until the inventory is reconciled.
MALFUNCTIONING TAGS
If a tag/capsule/cap has not been properly assembled,
the screen will say MALFUNCTIONING TAG – REMOVE AND
REPLACE.
When this happens, remove the controlled substances that
are noted on the screen. Review NARC-iD Capsule Assembly
Instructions (page 9). Verify that the locking tab is fully
inserted as noted in step 5. After this has been verified, try
using the capsule again. If the tag continues to malfunction,
try a new cap/tag.

15
NARC ID CENTRAL STORAGE UNIT (CSU) — Instructions
Caps (sold in boxes of 50; includes tags):
RF-CAP-FENTA (blue for fentaNYL)
RF-CAP-MIDAZ (orange for Midazolam)
RF-CAP-MORPH (purple for Morphine)
RF-CAP-HYDRO (green for HYDROmorphone)
RF-CAP-KETAM (yellow for Ketamine)
RF-CAP-MEPER (tan for Meperidine)
RF-CAP-DIAZE (gray for diazePAM)
RF-CAP-LORAZ (pink for LORazepam)
RF-CAP-GENER (white for Generic)
Capsules (sold in packs of 25):
RF-CPS-SHORT (short)
RF-CPS-MEDIUM (medium)
RF-CPS-LONG (long)
RF-CPS-OBLONG (oblong)
Tags:
RF-TAG-FENTA (blue for fentaNYL)
RF-TAG-MIDAZ (orange for Midazolam)
RF-TAG-MORPH (purple for Morphine)
RF-TAG-HYDRO (green for HYDROmorphone)
RF-TAG-KETAM (yellow for Ketamine)
RF-TAG-MEPER (tan for Meperidine)
RF-TAG-DIAZE (gray for diazePAM)
RF-TAG-LORAZ (pink for LORazepam)
RF-TAG-GENER (white for Generic)
Totes (sold individually with no caps or capsules):
RF-TOTE-SMALL (small)
RF-TOTE-LARGE (large)
NARC iD Central Storage Unit Accessories
NARC iD Colors for tags and caps by medicine
Pantone 311C
fentaNYL
Pantone 4525C
Meperidine
Pantone 158C
Midazolam
Pantone 2593C
Morphine
Pantone 361C
HYDROmorphone
Pantone Yellow C
Ketamine
white
Generic
Pantone 423C
diazePAM LORazepam
Pantone 203C
Note: product images are not to scale.

16
LockView®
LOCKVIEW-5iD-PRO
Includes:
one network license
and one client license
LOCKVIEW-5iD
Includes one client license
HID®Prox User,
Supervisor Cards
EL-2004-PC (no logo)
EL-ICLASS-C
(HID iCLASS user,
supervisor card)
HID®Fobs
EL-PR-FOB
EL-IC-FOB
HID®Prox Tags
EL-2004-PT
EL-ICLASS-T
(HID iCLASS tag)
120V Power Supply
(120V three-prong plug
to 12V brick 2.5MM DC)
300-AC12V
NARC iD Central Storage Unit Accessories — continued
HID is a trademark
of HID Corporation.
LockView 5iD Pro is easy to use, with many
programmable options, and allows access
to any eLock from any computer on the network.
SOFTWARE
LockView®software*features:
wTracks narcotic consumed and ties it
to the personnel accessing the NARC Box
wAutomatically enrolls and translates
the narcotic name into the software
wManual inputs:
mDrug manufacturer
mLot number
mExpiration date
mDate added
mDate consumed
Minimum System Requirements
Windows Vista, 7, 8, 8.1, 10, Server 2008/2012 and R2 versions.
4GB RAM - Processor 2.0 GHz or higher. (8GB recommended)
4GB Hard drive space. SQL Server Standard, Enterprise, or SQL
Express 2008/2012/2014 and R2 versions. If installing LockView
on the Microsoft SQL Server please follow Microsoft SQL’s
minimum requirements. ODBC connection required to Server.
Local Administrator Rights are required to install and register the
software. .Net 4.0 Client Framework.
* LockView software sold separately
Part #: 334346-0000-00
Copyright 2020 © CompX Security Products / 847.752.2500 / compx.com / 715 Center St., Grayslake, IL 60030
Any companies and/or products referred to herein are marks or registered trademarks of their respective companies, owners and/or mark holders.
Table of contents
Popular Storage manuals by other brands

Dahua
Dahua ESS2016X user manual

Fujitsu
Fujitsu M2488 user guide

Konica Minolta
Konica Minolta bizhub 361 Function guide

Compaq
Compaq StorageWorks 3000 - RAID Array release note

ADIC
ADIC FastStor FastStor Mass Storage Device Installation and operating guide

Western Digital
Western Digital WD Extreme Quick install guide

Seagate
Seagate ST31000525SV - 1.0TB 7200RPM Sata... Product overview

Lenovo
Lenovo EMC2 px4-400r quick start guide

Konig & Meyer
Konig & Meyer 11936 quick start guide

Verbatim
Verbatim InSight 320GB user guide

SANHO
SANHO HyperDrive SPACE instructions

Harmonic
Harmonic Spectrum MediaCenter Series Component replacement guide